Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Lunar In Situ Materials-Based Surface Structure Technology Development Efforts at NASA/MSFC

For long-duration missions on other planetary bodies, the use of in situ materials will become increasingly critical. As man's presence on these bodies expands, so must the structures to accommodate them, including habitats, laboratories, berms, radiation shielding for surface reactors, garages, solar storm shelters, greenhouses, etc. The use of in situ materials will significantly offset required launch upmass and volume issues. Under the auspices of the In Situ Fabrication & Repair (ISFR) Program at NASA/Marshall Space Flight Center (MSFC), the Surface Structures project has been developing materials and construction technologies to support development of these in situ structures. This paper will report on the development of several of these technologies at MSFC's Prototype Development Laboratory (PDL). These technologies include, but are not limited to, development of extruded concrete and inflatable concrete dome technologies based on waterless and water-based concretes, development of regolith-based blocks with potential radiation shielding binders including polyurethane and polyethylene, pressure regulation systems for inflatable structures, production of glass fibers and rebar derived from molten lunar regolith simulant, development of regolithbag structures, and others, including automation design issues. Results to date and lessons learned will be presented, along with recommendations for future activities.

Fiske, M. R.↗

Recent Advances in the Use of TRIPOLI-4 Monte Carlo Code for Radiation Protection and Shielding Calculations - Paper 47

TRIPOLI-4 is a general purpose radiation transport code. It uses the continuous-energy Monte Carlo method to simulate neutron, photon, electron and positron transport in three-dimensional geometries. The main application areas of TRIPOLI-4 code include radiation protection and shielding, fission reactor physics, nuclear criticality safety, fusion reactor design, and nuclear instrumentation. For the radiation protection and shielding calculations with TRIPOLI-4 code, miscellaneous radiation sources options, various variance reduction options, and many useful tally options are available. Perturbation calculations on material densities and nuclide concentrations are routinely used in radiation protection applications. Parallel calculations with TRIPOLI-4 are also easy to perform with a PC under the linux/unix OS. To help the users to get the feedback from their test runs during the input data preparation and adjustment and to analyze the intermediate and final results from their production runs, several user-interface tools have been introduced. By using some application cases in the fields of radiation shielding, radiation dosimetry, and gamma spectrometry, this paper summarizes and demonstrates some essential improvements and possibilities in the use of TRIPOLI-4 code on fixed source calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GCR Environmental Models III: GCR Model Validation and Propagated Uncertainties in Effective Dose

This is the last of three papers focused on quantifying the uncertainty associated with galactic cosmic rays (GCR) models used for space radiation shielding applications. In the first paper, it was found that GCR ions with Z>2 and boundary energy below 500 MeV/nucleon induce less than 5% of the total effective dose behind shielding. This is an important finding since GCR model development and validation have been heavily biased toward Advanced Composition Explorer/Cosmic Ray Isotope Spectrometer measurements below 500 MeV/nucleon. Weights were also developed that quantify the relative contribution of defined GCR energy and charge groups to effective dose behind shielding. In the second paper, it was shown that these weights could be used to efficiently propagate GCR model uncertainties into effective dose behind shielding. In this work, uncertainties are quantified for a few commonly used GCR models. A validation metric is developed that accounts for measurements uncertainty, and the metric is coupled to the fast uncertainty propagation method. For this work, the Badhwar-O'Neill (BON) 2010 and 2011 and the Matthia GCR models are compared to an extensive measurement database. It is shown that BON2011 systematically overestimates heavy ion fluxes in the range 0.5-4 GeV/nucleon. The BON2010 and BON2011 also show moderate and large errors in reproducing past solar activity near the 2000 solar maximum and 2010 solar minimum. It is found that all three models induce relative errors in effective dose in the interval [-20%, 20%] at a 68% confidence level. The BON2010 and Matthia models are found to have similar overall uncertainty estimates and are preferred for space radiation shielding applications.

Slaba, Tony C.↗

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation. We have confirmed that this software accurately calculates air-kerma rates and required barrier thicknesses for diagnostic radiography and fluoroscopic rooms.

07 ISOTOPE AND RADIATION SOURCES↗

Polyolefin-Based Aerogels

An organic polybutadiene (PB) rubberbased aerogel insulation material was developed that will provide superior thermal insulation and inherent radiation protection, exhibiting the flexibility, resiliency, toughness, and durability typical of the parent polymer, yet with the low density and superior insulation properties associated with the aerogels. The rubbery behaviors of the PB rubber-based aerogels are able to overcome the weak and brittle nature of conventional inorganic and organic aerogel insulation materials. Additionally, with higher content of hydrogen in their structure, the PB rubber aerogels will also provide inherently better radiation protection than those of inorganic and carbon aerogels. Since PB rubber aerogels also exhibit good hydrophobicity due to their hydrocarbon molecular structure, they will provide better performance reliability and durability as well as simpler, more economic, and environmentally friendly production over the conventional silica or other inorganic-based aerogels, which require chemical treatment to make them hydrophobic. Inorganic aerogels such as silica aerogels demonstrate many unusual and useful properties. There are several strategies to overcoming the drawbacks associated with the weakness and brittleness of silica aerogels. Development of the flexible fiber-reinforced silica aerogel composite blanket has proven one promising approach, providing a conveniently fielded form factor that is relatively robust toward handling in industrial environments compared to silica aerogel monoliths. However, the flexible silica aerogel composites still have a brittle, dusty character that may be undesirable, or even intolerable, in certain applications. Although the cross-linked organic aerogels such as resorcinol-formaldehyde (RF), polyisocyanurate, and cellulose aerogels show very high impact strength, they are also very brittle with little elongation (i.e., less rubbery). Also, silica and carbon aerogels are less efficient radiation shielding materials due to their lower content of hydrogen element. The present invention relates to maleinized polybutadiene (or polybutadiene adducted with maleic anhydride)- based aerogel monoliths and composites, and the methods for preparation. Hereafter, they are collectively referred to as polybutadiene aerogels. Specifically, the polybutadiene aerogels of the present invention are prepared by mixing a maleinized polybutadiene resin, a hardener containing a maleic anhydride reactive group, and a catalyst in a suitable solvent, and maintaining the mixture in a quiescent state for a sufficient period of time to form a polymeric gel. After aging at elevated temperatures for a period of time to provide uniformly stronger wet gels, the micro porous maleinized polybutadiene- based aerogel is then obtained by removing interstitial solvent by supercritical drying. The mesoporous maleinized polybutadiene-based aerogels contain an open-pore structure, which provides inherently hydrophobic, flexible, nearly unbreakable, less dusty aerogels with excellent thermal and physical properties. The materials can be used as thermal and acoustic insulation, radiation shielding, and vibration-damping materials. The organic PB-based rubber aerogels are very flexible, no-dust, and hydrophobic organics that demonstrated the following ranges of typical properties: densities of 0.08 to 0.255 grams per cubic centimeters, shrinkage factor (raerogel/rtarget) = 1.2 to 2.84, and thermal conductivity values of 20.0 to 35.0 mW/m-K.

Lee, Je Kyun↗

Shielding requirements for manned orbiting space stations

A detailed parametric investigation of radiation shielding requirements was performed for first generation manned orbiting space stations. Two specific space station designs were studied; the results of the shielding analysis are based on the actual geometry of the vehicles, onboard equipment, and supplies. Results are presented for circular orbits ranging from 100 to 600 nautical miles and from 29° to 90° inclination. The effects of the geometry of the space stations, the use of personal shielding, and the use of particular shielding materials are discussed.

MANNED ORBITAL SPACE STATION /MOSS/↗

Natural circulation loop using liquid nitrogen for cryo-detection system

The natural circulation loop is designed for the cryogenic insert in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Sensitivity is the key parameter of a FTICR mass spectrometer and the cryo-cooling of the pre-amplifier can reduce the thermal noise level and thereby improve the signal-to-noise ratio. The pre-amplifier consisted of non-magnetic materials is thermally connected to the cooling loop which is passing through the flange maintaining ultra-high vacuum in the ion cell. The liquid nitrogen passes through inside of the loop to cool the pre-amplifier indirectly. At the end, a cryocooler is located to re-condense nitrogen vapor generated due to the heat from the pre-amplifier. The circulating fluid removes heat from the pre-amplifier and transports it to the cryocooler or heat sink. In this paper the natural circulation loop for cryogenic pre-amplifier is introduced for improving the sensitivity of cryo-detector. In addition, the initial cool-down of the system by a cryocooler is presented and the temperature of the radiation shield is discussed with respect to the thickness of shield and the thermal radiation load.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of minor actinides burner with an accelerator-driven subcritical system.

In the environmental impact study of the Yucca Mountain nuclear waste repository, the limit of spent nuclear fuel (SNF) for disposal is assessed at 70,000 metric tons of heavy metal (MTHM), among which 63,000 MTHM are the projected SNF discharge from U.S. commercial nuclear power plants though 2011. Within the 70,000 MTHM of SNF in storage, approximately 115 tons would be minor actinides (MAs) and 585 tons would be plutonium. This study describes the conceptual design of an accelerator-driven subcritical (ADS) system intended to utilize (burn) the 115 tons of MAs. The ADS system consists of a subcritical fission blanket where the MAs fuel will be burned, a spallation neutron source to drive the fission blanket, and a radiation shield to reduce the radiation dose to an acceptable level. The spallation neutrons are generated from the interaction of a 1 GeV proton beam with a lead-bismuth eutectic (LBE) or liquid lead target. In this concept, the fission blanket consists of a liquid mobile fuel and the fuel carrier can be LBE, liquid lead, or molten salt. The actinide fuel materials are dissolved, mixed, or suspended in the liquid fuel carrier. Therefore, fresh fuel can be fed into the fission blanket to adjust its reactivity and to control system power during operation. Monte Carlo analyses were performed to determine the overall parameters of an ADS system utilizing LBE as an example. Steady-state Monte Carlo simulations were studied for three fission blanket configurations that are similar except that the loaded amount of actinide fuel in the LBE is either 5, 7, or 10% of the total volume of the blanket, respectively. The neutron multiplication factor values of the three configurations are all approximately 0.98 and the MA initial inventories are each approximately 10 tons. Monte Carlo burnup simulations using the MCB5 code were performed to analyze the performance of the three conceptual ADS systems. Preliminary burnup analysis shows that all three conceptual ADS systems consume about 1.2 tons of actinides per year and produce 3 GW thermal power, with a proton beam power of 25 MW. Total MA fuel that would be consumed in the first 10 years of operation is 9.85, 11.80, or 12.68 tons, respectively, for the systems with 5, 7, or 10% actinide fuel particles loaded in the LBE. The corresponding annual MA fuel transmutation rate after reaching equilibrium at 10 years of operation is 0.83, 0.94, or 1.02 tons/year, respectively. Assuming that the ADS systems can be operated for 35 full-power years, the total MAs consumed in the three ADS systems are 30.6, 35.3, and 37.2 tons, respectively. For the three configurations, it is estimated that 3.8, 3.3, or 3.1 ADS system units are required to utilize the entire 115 tons of MA fuel in the SNF inventory, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A simple code for use in shielding and radiation dosage analyses

A simple code for use in analyses of gamma radiation effects in laminated materials is described. Simple and good geometry is assumed so that all multiple collision and scattering events are excluded from consideration. The code is capable of handling laminates up to six layers. However, for laminates of more than six layers, the same code may be used to incorporate two additional layers at a time, making use of punch-tape outputs from previous computation on all preceding layers. Spectrum of attenuated radiation are obtained as both printed output and punch tape output as desired.

Wan, C. C.↗

Vaporization characteristics of carbon heat shields under radiative heating.

Study of the vaporization characteristics of samples of ATJ graphite, a material that has been considered for use on a Jovian probe. These samples were subjected to radiative heating loads of approximately 2 kW/sq cm in argon atmospheres of pressures from 0.00046 to 1 atm. Surface temperatures, mass loss rates, and spatially resolved emission spectral data were recorded. These data are analyzed to determine carbon vapor pressure as a function of temperature and are compared with current models for the vapor pressure of carbon. The effects of finite vaporization (i.e., nonequilibrium) rates are considered and compared with experiment. Estimates of the heat of vaporization from an energy balance are also presented.

Davy, W. C.↗

Thermal fatigue tests of a radiative heat shield panel for a hypersonic transport

A pair of corrugation stiffened, beaded skin Rene 41 heat shield panels were exposed to 20,000 thermal cycles between room temperature and 1450 F to evaluate the thermal fatigue response of Rene 41 metallic heat shields for hypersonic cruise aircraft applications. At the conclusion of the tests, the panels retained substantial structural integrity; however, there were cracks and excessive wear in the vicinity of fastener holes and there was an 80-percent loss in ductility of the skin. Shrinkage of the panel which caused the cracks and wear must be considered in design of panels for Thermal Protection Systems (TPS) applications.

Webb, Granville L.↗

Preliminary Design of a Galactic Cosmic Ray Shielding Materials Testbed for the International Space Station

The preliminary design of a testbed to evaluate the effectiveness of galactic cosmic ray (GCR) shielding materials, the MISSE Radiation Shielding Testbed (MRSMAT) is presented. The intent is to mount the testbed on the Materials International Space Station Experiment-X (MISSE-X) which is to be mounted on the International Space Station (ISS) in 2016. A key feature is the ability to simultaneously test nine samples, including standards, which are 5.25 cm thick. This thickness will enable most samples to have an areal density greater than 5 g/sq cm. It features a novel and compact GCR telescope which will be able to distinguish which cosmic rays have penetrated which shielding material, and will be able to evaluate the dose transmitted through the shield. The testbed could play a pivotal role in the development and qualification of new cosmic ray shielding technologies.

Gaier, James R.↗