Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIAL DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the initiation and evolution of dielectric breakdown in auto-magnetizing liner experiments

Auto-magnetizing (AutoMag) liners are cylindrical tubes composed of discrete metallic helices encapsulated in insulating material; when driven with a ~2 MA, ~100-ns prepulse on the 20 MA, 100-ns rise time Z accelerator, AutoMag targets produced >150 T internal axial magnetic fields. Once the current rise rate of the pulsed power driver reaches sufficient magnitude, the induced electric fields in the liner cause dielectric breakdown of the insulator material and, with sufficient current, the cylindrical target radially implodes. The dielectric breakdown process of the insulating material in AutoMag liners has been studied in experiments on the 500–900 kA, ~100-ns rise time Mykonos accelerator. Multi-frame gated imaging enabled the first time-resolved observations of photoemission from dynamically evolving plasma distributions during the breakdown process in AutoMag targets. Using magnetohydrodynamic simulations, we calculate the induced electric field distribution and provide a detailed comparison to the experimental data. We find that breakdown in AutoMag targets does not primarily depend on the induced electric field in the gaps between conductive helices as previously thought. Finally, to better control the dielectric breakdown time, a 12–32 mJ, 170 ps ultraviolet (λ = 266 nm) laser was implemented to irradiate the outer surface of AutoMag targets to promote breakdown in a controlled manner at a lower internal axial field. Here, the laser had an observable effect on the time of breakdown and subsequent plasma evolution, indicating that pulsed UV lasers can be used to control breakdown timing in AutoMag.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and modeling of type-I and type-II ELMs heat flux to the DIII-D divertor

Type-I and type-II edge-localized-modes (ELMs) heat flux profiles measured at the DIII-D divertor feature a peak in the vicinity of the strike-point and a plateau in the scrape-off-layer (SOL), which extends to the first wall. The plateau is present in attached and detached divertors and it is found to originate with plasma bursts upstream in the SOL. The integrated ELM heat flux is distributed at ~65% in the peak and ~35% in this plateau. The parallel loss model, currently used at ITER to predict power loads to the walls, is benchmarked using these results in the primary and secondary divertors with unprecedented constraints using experimental input data for ELM size, radial velocity, energy, electron temperature and density, heat flux footprints and number of filaments. The model can reproduce the experimental near-SOL peak within ~20%, but cannot match the SOL plateau. Employing a two-component approach for the ELM radial velocity, as guided by intermittent data, the full radial heat flux profile can be well matched. The ELM-averaged radial velocity at the separatrix, which explains profile widening, increases from ~0.2 km s –1 in attached to ~0.8 km s –1 in detached scenarios, as the ELM filaments' path becomes electrically disconnected from the sheath at the target. The results presented here indicate filaments fragmentation as a possible mechanism for ELM transport to the far-SOL and provide evidence on the beneficial role of detachment to mitigate ELM flux in the divertor far-SOL. However, these findings imply that wall regions far from the strike points in future machines should be designed to withstand significant heat flux, even for small-ELM regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Azimuthally averaged wind and thermodynamic structures of tropical cyclones in global climate models and their sensitivity to horizontal resolution

Characteristics of tropical cyclones (TCs) in global climate models (GCMs) are known to be influenced by details of the model configurations, including horizontal resolution and parameterization schemes. Understanding model-to-model differences in TC characteristics is a prerequisite for reducing uncertainty in future TC activity projections by GCMs. This study performs a process-level examination of TC structures in eight GCM simulations that span a range of horizontal resolutions from 1° to 0.25°. A recently developed set of process-oriented diagnostics is used to examine the azimuthally averaged wind and thermodynamic structures of the GCM-simulated TCs. Results indicate that the inner-core wind structures of simulated TCs are more strongly constrained by the horizontal resolutions of the models than are the thermodynamic structures of those TCs. As expected, the structures of TC circulations become more realistic with smaller horizontal grid spacing, such that the radii of maximum wind (RMW) become smaller, and the maximum vertical velocities occur off the center. However, the RMWs are still too large, especially at higher intensities, and there are rising motions occurring at the storm centers, inconsistently with observations. The distributions of precipitation, moisture, radiative and surface turbulent heat fluxes around TCs are diverse, even across models with similar horizontal resolutions. At the same horizontal resolution, models that produce greater rainfall in the inner-core regions tend to simulate stronger TCs. Further, when TCs are weak, the radial gradient of net column radiative flux convergence is comparable to that of surface turbulent heat fluxes, emphasizing the importance of cloud-radiative feedbacks during the early developmental phases of TCs.

54 ENVIRONMENTAL SCIENCES↗

In situ X-ray spatial profiling reveals uneven compression of electrode assemblies and steep lateral gradients in lithium-ion coin cells

Coin cells are used extensively as test devices in battery research for evaluation of new materials and optimization of cycling protocols. Here, in situ X-ray diffraction profilometry is used to characterize spatial distribution of the active materials, lithiation, and phase distribution in electrodes of NCM523/graphite coin cells. The X-ray data indicate uneven areal compression of the electrode assembly in such cells, which we trace to a specific design feature that leads to elastic deformation of a metal spacer. Steep lithiation gradients observed in the electrodes imply radially-dependent resistivity, for which uneven compression of the separator is a likely cause. Electrochemical model calculations suggest that variable porosity of the polymer separator would account for the salient features of spatial profiles observed in these coin cells.

25 ENERGY STORAGE↗

The formation of an radial edge electric field due to finite ion orbit width effects is the possible root cause of the H-mode edge

Abstract Full orbit-following simulations of thermal ions show that finite ion-orbit width effects create charge separation near the last closed flux surface (LCFS) which generates a localized radial electric field. Experimentally, edge electric fields are observed in H-mode plasmas and they are necessary for the edge turbulence suppression via the E × B flow shear mechanism. Confined trapped (and to a lesser extent co-passing) ions near the plasma edge form a positive charge distribution outside the LCFS, while thermal electrons are tied more tightly to field lines owing to their small mass and are poorly confined outside the LCFS, hence charge neutrality is violated outside the LCFS. A large number of reported observations from spherical and conventional tokamaks support the results from the simulations although the simulations were not performed fully self consistently. The results suggest ways to lower the H-mode power threshold and optimize the H-mode plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visual Orbits of Spectroscopic Binaries with the CHARA Array. III. HD 8374 and HD 24546

We present the visual orbits of two long-period spectroscopic binary stars, HD 8374 and HD 24546, using interferometric observations acquired with the CHARA Array and the Palomar Testbed Interferometer. We also obtained new radial velocities from echelle spectra using the APO 3.5 m and Fairborn 2.0 m telescopes. By combining the visual and spectroscopic observations, we solve for the full, three-dimensional orbits and determine the stellar masses and distances to within 3% uncertainty. We then estimate the effective temperature and radius of each component star through Doppler tomography and spectral energy distribution analyses, in order to compare the observed stellar parameters to the predictions of stellar evolution models. For HD 8374, we find masses of M {sub 1} = 1.636 ± 0.050M {sub ⊙} and M {sub 2} = 1.587 ± 0.049M {sub ⊙}, radii of R {sub 1} = 1.84 ± 0.05R {sub ⊙} and R {sub 2} = 1.66 ± 0.12R {sub ⊙}, temperatures of T{sub eff1}=7280±110 K and T{sub eff2}=7280±120 K, and an estimated age of 1.0 Gyr. For HD 24546, we find masses of M {sub 1} = 1.434 ± 0.014M {sub ⊙} and M {sub 2} = 1.409 ± 0.014M {sub ⊙}, radii of R {sub 1} = 1.67 ± 0.06R {sub ⊙} and R {sub 2} = 1.60 ± 0.10R {sub ⊙}, temperatures of T{sub eff1}=6790±120 K and T{sub eff2}=6770±90 K, and an estimated age of 1.4 Gyr. HD 24546 is therefore too old to be a member of the Hyades cluster, despite its physical proximity to the group.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Detection of the Orbital Modulation of Fe Kα Fluorescence Emission in Centaurus X-3 Using the High-resolution Spectrometer Resolve on board XRISM

Abstract The Fe K α fluorescence line emission in X-ray spectra is a powerful diagnostic tool for various astrophysical objects to reveal the distribution of cold matter around photoionizing sources. The advent of the X-ray microcalorimeter on board the XRISM satellite will bring new constraints on the emission line. We present one of the first such results for the high-mass X-ray binary Centaurus X-3, which is composed of an O-type star and a neutron star (NS). We conducted a 155 ks observation covering an entire binary orbit. A weak Fe K α line was detected in all orbital phases at an equivalent width (EW) of 10–20 eV. We found for the first time that its radial velocity (RV) is sinusoidally modulated by the orbital phase. The RV amplitude is 248 ± 13 km s −1 , which is significantly smaller than the value (391 km s −1 ) expected if the emission is from the NS surface, but is consistent if the emission takes place at the O star surface. We discuss several possibilities of the line production site, including the NS surface, O star surface, O star wind, and accretion stream from the O star to the NS. We ran radiative transfer calculation for some of them assuming spherically symmetric density and velocity profiles and an isotropic distribution of X-ray emission from the NS. None of them explains the observed EW and velocity dispersion dependence on the orbital phase, suggesting that more elaborated modeling is needed. In other words, the present observational results have the capability to constrain deviations from these assumptions.

High energy astrophysics↗

Massive red spiral galaxies in SDSS-IV MaNGA survey

ABSTRACT Massive red spiral galaxies (MRSGs) are supposed to be the possible progenitors of lenticular galaxies (S0s). We select a large sample of MRSGs ($M_*\gt 10^{10.5}\rm {\rm M}_{\odot }$) from Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) DR17 using the g − r colour versus stellar mass diagram, along with control samples of blue spirals and S0s. Our main results are as follows: (1) After comparing the Sérsic index, concentration parameter, asymmetry parameter distribution, size–mass relation, and Σ1 (stellar mass surface density within the central 1 kpc)−mass relation, we find MRSGs are similar to S0s and have more compact and symmetric structures than blue spirals. MRSGs also resemble S0s in Dn4000, metallicity, Mgb/$\rm \left\langle Fe \right\rangle$, and V/σ radial profile. (2) By using MaNGA 2D spectra data, we separate the spatial regions into inner (R < 0.8Re) and outer (0.8 < R < 1.5Re) regions, and detect residual star formation in the outer regions of MRSGs. (3) When we select a sub-sample of MRSGs with NUV − r > 5, we find that they are completely star formation quenched in both inner and outer regions. Compared to optically selected MRSGs, NUV − r selected MRSGs appear to be more concentrated and have more massive dark matter haloes. The similarities between S0s and MRSGs suggest the possible evolutionary trend between MRSGs and S0s.

Astronomy & Astrophysics↗

Effects of divertor electrical drifts on particle distribution and detachment near the divertor target plate in DIII-D

Strong impacts of drifts on the divertor plasma in–out asymmetry and detachment are demonstrated in DIII-D with an open divertor configuration. For forward toroidal field, B T , i.e., with the ion B × ∇B drift toward the divertor, the particle flux to the inner divertor, as represented by the Langmuir probe measured ion saturation current (J sat ), exhibits a double peak structure, with electron temperature, lower at the inner target. Reversing the B T direction reverses both the radial and poloidal E × B flows, leading to a broad particle flux profile in the outboard scrape-off layer (SOL) with a similar double-peak structure to that observed at the inner target with forward B T . The correlation of a double peak structure with divertor temperature profiles confirms physical coupling between the drift flow and sheath boundary condition and their strong impact on divertor profiles. In addition, under reversed B T conditions, increasing the density flattens the target temperature profile. However, J sat remains high away from the strike point, rendering it difficult to achieve an “effective” detached plasma, i.e., with effective reduction in both peak heat flux and peak temperature (in the far SOL). In contrast, divertor detachment with a cold and flat temperature profile can be achieved at both target plates with the forward B T .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Challenges and approaches to interpretive modeling of boundary plasma and neutral transport in a closed, pumped divertor

An experimental discharge from the DIII-D tokamak is modeled using the SOLPS-ITER code suite and compared against measurements in the pumped and relatively closed upper divertor. Uncertainties of boundary plasma simulations are identified by attempting to match code inputs to experimental conditions, including iteratively solving transport coefficients to match upstream experimental profiles using varying quantities of core particle flux, different pumping models, and various assumptions of ion thermal transport. Simulated boundary conditions for particle injection at the core interface are shown to be relevant to the plasma solution at the divertor targets, even if upstream transport is modified so that plasma profiles are comparatively similar, although seperatrix density is not held constant. When upstream plasma profiles are matched to experimental measurements by varying diffusive transport coefficients, using either poloidally symmetric or ballooning structure, the model finds a majority of injected energy being transported radially off the computational domain, in conflict with experimental radiated power measurements and heat flux measurements at the divertor target. Imposing a maximum thermal diffusivity or radially shifting the experimental separatrix location of the fitted profiles to increase power conducted to the targets by increasing the upstream electron temperature does not significantly modify this result. Including a thermalizing plenum volume in the simulation domain is shown to maintain the experimental volumetric pumping rate without knowing the neutral energy distribution incident on the pump duct a priori. By modifying transport parameters to match different assumptions for ion temperature, downstream neutral pressure changes by more than a factor of two, suggesting that attention to ion thermal transport may be a critical parameter for simulations to accurately resolve recycling and neutral transport, particularly in a closed divertor geometry. In addition to quantifying various modeling uncertainties, this work motivates both further experimental study and modeling improvements to improve predictive capabilities.

divertor↗

Using strong lensing to detect subhaloes with steep inner density profiles

ABSTRACT The inner region of a subhalo’s density distribution is particularly sensitive to dark matter microphysics, with alternative dark matter models leading to both cored and steeply-rising inner density profiles. This work investigates how the lensing signature and detectability of dark matter subhaloes in mock HST-, Euclid-, and JWST-like strong lensing observations depend on the subhalo’s radial density profile, especially with regards to the inner power-law slope, $\beta$. We demonstrate that the minimum subhalo mass detectable along the Einstein ring of a system is strongly dependent on $\beta$. In particular, we show that subhaloes with $\beta = 2.2$ can be detected down to masses over an order-of-magnitude lower than their Navarro–Frenk–White (NFW) counterparts with $\beta = 1$. Importantly, we find that the detectability of subhaloes with steep inner profiles is minimally affected by increasing the complexity of the main lens galaxy’s mass model. This is a notable characteristic of these subhaloes, as those with NFW or shallower profiles become essentially undetectable when multipole perturbations are added to the lens model. The results of this work highlight how the underlying dark matter physics can significantly impact the expected number of subhalo detections from strong gravitational lensing observations. This is important for testing Cold Dark Matter against alternative models, such as Self-Interacting Dark Matter, that predict a diverse range of subhalo inner density profiles.

dark matter↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Flares, Warps, Truncations, and Satellite: The Ultra-thin Galaxy UGC 11859

The structure of the outskirts of galaxies provides valuable information about their past and evolution. Due to their projected orientation, edge-on isolated galaxies effectively serve as test labs in which to study the three-dimensional structures of galaxies, including warps and flares, and to explore the possible sources of such distortions. We analyzed the structure of the apparently isolated edge-on ultra-thin galaxy UGC 11859 to look for the presence of distortions. The deep optical imaging observations (${\mu }_{\mathrm{lim}}=30.6$ and 30.0 $\mathrm{mag}\ {\mathrm{arcsec}}^{-2}$ in the g- and r-bands, respectively) we acquired with the 10.4 m Gran Telescopio Canarias are used to derive the radial and vertical surface brightness profiles and g - r color radial profile. We find that UGC 11859's disk displays a significant gravitational distortion. A warp is clearly detected on one side of the disk, and the galactic plane on both sides of the center shows increasing scale height with an increasing galactocentric radius, indicating the presence of a flare in the stellar distribution. The surface brightness profile of the disk shows a sharp break at 24 kpc galactocentric radius, and a steep decline to larger radii, an "edge-on truncation," which we associate with the presence of the flare. The present study is the first observational support for a connection between truncations and flares. Just beyond the warped side of the disk, a faint galaxy is observed within a small angular distance, identified as a potential interacting companion. Based on ultradeep g and r photometry we estimate that if the potential companion is at the same distance as UGC 11859, the stellar mass of the satellite galaxy is log 10 (M ⊙ ) = ${6.33}_{-0.02}^{+0.02}$ .

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stellar Radial Velocities in the Old Open Cluster M67 (NGC 2682). II. The Spectroscopic Binary Population

We present and analyze 120 spectroscopic binary and triple cluster members of the old (4 Gyr) open cluster M67 (NGC 2682). As a cornerstone of stellar astrophysics, M67 is a key cluster in the WIYN Open Cluster Study (WOCS); radial-velocity (RV) observations of M67 are ongoing and extend back over 45 yr, incorporating data from seven different telescopes, and allowing us to detect binaries with orbital periods ≲10{sup 4} days. Our sample contains 1296 stars (604 cluster members) with magnitudes of 10 ≤ V ≤ 16.5 (about 1.3–0.7 M {sub ⊙}), from the giants down to ∼4 mag below the main-sequence turnoff, and extends in radius to 30′ (7.4 pc at a distance of 850 pc, or ∼7 core radii). This paper focuses primarily on the main-sequence binaries, but orbital solutions are also presented for red giants, yellow giants, and sub-subgiants. Out to our period detection limit and within our magnitude and spatial domain, we find a global main-sequence incompleteness-corrected binary fraction of 34% ± 3%, which rises to 70% ± 17% in the cluster center. We derive a tidal circularization period of P{sub circ}=11.0{sub −1.0}{sup +1.1} days. We also analyze the incompleteness-corrected distributions of binary orbital elements and masses. The period distribution rises toward longer periods. The eccentricity distribution, beyond P {sub circ}, is consistent with a uniform distribution. The mass-ratio distribution is also consistent with a uniform distribution. Overall, these M67 binaries are closely consistent with similar binaries in the galactic field, as well as with the old (7 Gyr) open cluster NGC 188. WOCS. 83.

47 OTHER INSTRUMENTATION↗