Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proportional counters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Imaging X-ray spectrophotometric observation of SN 1006

An imaging gas scintillation proportional counter (IGSPC) at the focal plane of a grazing incidence telescope was carried aloft by a sounding rocket and used to observe soft X-ray emission from the supernova remnant SN 1006. The instrument obtained the first unambiguous detection of strong (8 + or 0.0-2 photons/sq cm s) oxygen He-alpha and Ly-alpha emission at 0.59 + or - 0.02 keV from SN 1006. This line emission is consistent with emission from a 1.8 x 10 to the 6th K plasma, although hard X-ray emission from an additional power law or a higher temperature component was also observed. The X-ray emission may be interpreted as due to either (1) a combination of blast-wave and reverse shock assuming equilibrium ionization in the plasma or (2) blast-wave emission alone with a significant degree of ionization disequilibrium.

Vartanian, M. H.↗

The X-ray corona of Procyon

X-ray emission from the nearby system Procyon A/B (F5 IV + DF) was detected, using the IPC (Imaging Proportional Counter) on board the Einstein Observatory. Analysis of the X-ray pulse height spectrum suggests that the observed X-ray emission originates in Procyon A rather than in the white dwarf companion Procyon B, since the derived X-ray temperature, log T = 6.2, agrees well with temperatures found for quiescent solar X-ray emission. Modeling Procyon's corona with loops characterized by some apex temperature Tmax and emission length scale L, it is found that Tmax is well constrained, but L, and consequently the filling factor of the X-ray emitting gas, are essentially unconstrained even when EUV emission from the transition region is included in the analysis.

Schmitt, J. H. M. M.↗

The Einstein soft X-ray survey of the Pleiades

The results of a 0.1-4.5-keV X-ray survey of a 2 x 2-deg area centered on the Pleiades open cluster, performed using the imaging proportional counter and high-resolution imager of the Einstein Observatory on four days in 1980-1981, are presented in extensive tables, graphs, maps, histograms, and finding charts and characterized. A total of 61 sources are detected, and 44 of these are identified with cluster members of spectral types B-M. Findings discussed include Lx/Lbol of 10 the -7th for early-type stars; F-star mean Lx like that of F stars in the Hyades and in the field (denying time evolution of Lx); mean G-star Lx = 3.7 x 10 to the 29th erg/sec; G-star activity decay more gradual than 1/sq rt t, with sharp fall for t greater than 1 Gyr; and no evidence for X-ray-emissivity/rotational-velocity correlation in a homogeneous sample of K dwarfs or a sample of K and M stars with established V sin i data.

Caillault, J.-P.↗

On fast X-ray rotators with long-term periodicities

The support of previous SAS 3 spacecraft observations by new data gathered by the Monitor Proportional Counter aboard the HEAO 2 spacecraft indicates that the pulse period history of the 13.5 sec-pulsing X-ray source LMC X-4 is consistent with standard accretion and torque models only if LMC X-4 is a fast rotator for which the accretion torques nearly cancel. This result leads to a neutron star magnetic field strength estimate of about 1.2 x 10 to the 13th G. Strong evidence is noted for Her X-1's status as a fast rotator, while SMC X-1 is probably an intermediate-to-fast rotator. In the context of slaved disk models for these objects, it is noted that the precession periods expected for the companion stars are significantly longer than the observed 1-2 month time scales; slaved disk models are thereby undermined.

Naranan, S.↗

An X-ray study of the Centaurus Cluster of galaxies using Einstein

Einstein Imaging Proportional Counter observations of the core of the Centaurus Cluster of galaxies have been analyzed to map the 0.5-3.5 keV surface brightness and temperature of the intracluster gas. The emission is centered on NGC 4696, the elliptical galaxy believed to be at or near the dynamical center of the cluster. Because the X-ray-emitting gas responds to the gravitational potential of the cluster, the observations may be used to measure the total mass distribution around the central region. It is shown that the gas is very likely in hydrostatic equilibrium. It is found that surrounding NGC 4696, like M87 at the center of the Virgo Cluster, is a dark, massive halo, with a gravitating mass of about 2 x 10 to the 13th M out to a radius of about 20 arcmin (or 200 kpc for H(o) = 50 km/s Mpc). The elliptical galaxy NGC 4709, at the core of a more distant cluster, is also detected with a luminosity of 2 x 10 to the 40th ergs per sec.

Matilsky, T.↗

X-ray emission from E and S0 galaxies with compact nuclear radio sources

The imaging proportional counter on the Einstein Observatory has been used to search for X-ray emission from 13 nearby E and S0 galaxies with compact nuclear radio sources. Five galaxies with X-ray luminosity of about 10 to the 41st ergs/s were detected, and one of them was resolved. These galaxies and a few similar ones observed by others are compared to a sample of radio-quiet E and S0 galaxies. The radio-emitting galaxies have consistently greater X-ray luminosities per unit of optical luminosity than most radio-quiet galaxies. Possible emission mechanisms and models for the resolved source, for the most powerful source, and for the class of E/S0 galaxies with active nuclei are discussed.

Dressel, L. L.↗

Variation of the pulse profile of Hercules X-1

The X-ray pulsar Her X-1 was observed in an on-state during its 35th cycle of activity in May, 1983 using the gas scintillation proportional counter (GSPC) array of the Tenma X-ray astronomy satellite. The outstanding features observed during the declining phase of the on-state included: a sharp decrease in the main X-ray pulse amplitude; and a steady increase in the column density of cool matter. On the basis of the spectral shape of the pulses, it is suggested that the main phase was attenuated due to electron scattering of the X-ray beam in a highly ionized medium located 3 x 10 to the 8th cm from the neutron star. Near the end of the on-state, the main pulse totally disappeared and a plain sinusoidal profile was observed. The observed pulse profiles are reproduced in graphic form.

Ohashi, T.↗

Transient dips of Cygnus X-1 observed from Tenma

The transient intensity dips of the binary system Cyg X-1 have been observed, using the gas scintillation proportional counter (GSPC) array onboard the Tenma X-ray astronomy satellite. The duration of the dips was in the range from several seconds to 10 minutes, with several dips occurring as much as 15 h before the superior conjunction. Within the dips, complex structures were observed with time scales of several seconds, and, in at least one case, shorter than two seconds. For a dip lasting longer than 10 minutes, a high-quality spectrum was obtained which reveals the K-absorption edge of iron at 7.18 + or - 0.18 keV. On the basis of the observed absorption, it is suggested that the dips are caused by absorption due to relatively cool matter (less than about 30,000 k); the low-energy excess observed during the dips is due either to an extended soft X-ray emitting corona or to partial obscuration of the X-ray source by multiple blobs. From the time structure of the dip, a blob size of the order of 10 to the 9th cm is derived.

Kitamoto, S.↗

The diversity of soft X-ray spectra in quasars

Soft X-ray spectra for three quasars obtained with the Einstein Imaging Proportional Counter covering the 0.1-4.0 keV band are reported. Power-law fits to these spectra have best-fit energy indices of 1.2 +0.6 or -0.2, for the quasar NAB 0205 + 024, 0.6 +0.3 or -0.2 for the quasar B2 1028 + 313, and 2.2 + or -0.4 for the quasar PG 1211 + 143. None of the quasars shows any evidence for a column density of cold matter in excess of the galactic values. The derived spectra demonstrate that there is no single universal power law slope for quasar X-ray spectra. The implications of these results for the X-ray background, X-ray continuum emission mechanisms, and the production of the optical/UV emission lines are briefly discussed.

Elvis, M.↗

Sounding rockets shot from the Shuttle

The Space Shuttle-launched sounding rocket Spartan-1 will map the structure of two extended X-ray sources: the hot gas pervading the Perseus cluster of galaxies, and the central core of the Milky Way. Spartan-1 contains two large X-ray proportional counter detectors sensitive to the 1-15 A wavelength range. A new generation of instruments destined for X-ray telescope focal planes will yield high resolution imaging and spectroscopy, over observation times sometimes exceeding one day/source, in the course of a long-term Spartan research program that will encompass planetary, solar, and UV astronomy missions.

Cruddace, R.↗

Complex structure of the supernova remnant HB 3

HB 3 is an old, large (84 pc diameter) supernova remnant associated with the W3 H II region/molecular cloud complex. Observations of the imaging proportional counter (IPC) onboard the Einstein X-ray astronomy satellite have been reprocessed to yield a contour map of X-ray brightness and spectra of various regions of this remnant. The measured IPC flux is 2.4 x 10 to the -11th ergs per sq cm per s, giving a 0.2-4 keV luminosity of 1.6 x 10 to the 35th ergs/s for a column densityof 6 x 10 to the 21st per sq cm. The measured X-ray temperatures reveal a decrease from center to limb of the remnant of 1-0.3 keV. HB 3 is in the late adiabatic blast-wave phase of evolution, 30,000 to 50,000 yr old and with an initial blast energy of 3 x 10 to the 50th ergs. The X-ray map is compared with available radio and optical images. In X-rays, HB 3 has two components - a diffuse emission inside the 84 pc radio remnant and a ring of emission at the center of 30 pc in diameter. The diffuse emission is similar to that from other supernova remnants which are moderately obscured (column density, nH approximately 10 to the 22nd per sq cm). Three possibilities for the origin of the ring are explored: (1) a second supernova remnant, (2) a shocked shell in the interstellar medium surrounding HB 3, and (3) reverse-shock heated ejecta. There is no hot neutron star within the remnant.

Leahy, D. A.↗

Composition of cosmic-ray nuclei from boron to nickel for 1200 to 2400 MeV per nucleon

Balloon-borne measurements of cosmic-ray nuclear abundances for Z = 5-28 and energies 1.2-1.4 GeV/nucleon, obtained using the scintillation/Cerenkov-counter telescope and multiwire proportional counter described by Dwyer et al. (1984) on four flights from Texas and Oklahoma during 1973-1975, are reported. The data are presented in tables and graphs and compared with published observations. Charge separation (sigma = 0.2 units for Fe) and exposure factor (38 sq m sr h) are attained, and the findings are found to be in good agreement with the predictions of a simple leaky-box model of the Galaxy and a pure exponential path-length distribution, although a nested-leaky-box model with some truncation is possible. The delay between e-process nucleosynthesis and cosmic-ray acceleration is estimated on the basis of the Co abundance at greater than 100 d and probably greater than 100,000 yr.

Dwyer, R.↗

Einstein observations of selected regions of the Cygnus Loop

The imaging proportional counter on the Einstein X-ray Observatory is used to obtain high quality soft X-ray maps of two 40 x 40 arcmin regions of the Cygnus Loop. One region covers the western shock front; the other is centered on the southern diffuse extension. After careful correction for background and detector gain variations these two regions were subdivided for X-ray spectral analysis. In both cases the spectra of the brightest X-ray emitting areas are characterized by temperatures of about 2 million K, whereas the spectra of the fainter diffuse regions are indicative of higher temperatures (T greater than about 4 million K) and suggest the presence of a second, hard component. These results, together with the correlation of the X-ray spatial distribution with the optical and radio maps, are discussed in terms of current models of supernova remnant evolution. The evidence suggests that the Cygnus Loop is the result of a Type II supernova of a star of initial mass of less than about 20 solar masses.

Charles, P. A.↗

On the viability of exploiting L-shell fluorescence for X-ray polarimetry

It has been suggested that one may build an X-ray polarimeter by exploiting the polarization dependence of the angular distribution of L-shell fluorescence photons. In this paper the sensitivity of this approach to polarimetry is examined theoretically. The calculations are applied to several detection schemes using imaging proportional counters that would have direct application in X-ray astronomy. It is found, however, that the sensitivity of this method for measuring X-ray polarization is too low to be of use for other than laboratory applications.

Weisskopf, M. C.↗

The X-ray spectra and the rotation-activity connection of RS CVN binaries

Results from a survey of RS CVn binaries which were observed with the Imaging Proportional Counter (IPC) on board the Einstein Observatory are presented. Spectral analyses of the IPC pulse height spectra show that the coronae of RS CVn binaries always contain hot gas with temperatures 10 million K, similar to active late-type main sequence stars, and that at least 2 temperature components are necessary to account for the higher quality IPC spectra (when absorption is unimportant). It is argued that these bimodal temperature distributions indicate true distributions of emission measure vs temperature that are continuous (just as is the case for magnetically-confined coronal plasma loops observed on the Sun). It is shown that none of the derivable X-ray characteristics of RS CVn binaries depend on rotation period, implying that claims of period-activity relationships in RS CVn binaries are unfounded.

Majer, P.↗

The HXII gas system

Two gas proportional counters were designed: one detector was patterned after the HEAO-1 design which possesses a proven low background capability at atmospheric pressure, and the other was a parallel planar geometry detector with an extensive drift region. The actual performance of the detectors was evaluated with emphasis on background rejection efficiency and position resolution.

Source record↗

Radioactivities in returned lunar materials and in meteorites

A preliminary C-14 study on lunar soil was carried out with the University of Toronto Iso Trace accelerator mass spectrometer. This accelerator was recommended for C-14 work by Dr. R. Schneider of A.S. and E., who was the field engineer during the assemblage and start-up operation of the accelerator. After the preliminary study using CO2 from 10084,937 soil, which had previously been counted with low-level mini-proportional counters, it became clear that the Toronto accelerator could carry out C-14/C-13/C-12 ratio measurements on 1 gram meteorite and lunar samples and that the C-14 measurements are done with higher precision and better reliability than elsewhere. A collaborative program with the University of Toronto Iso Trace accelerator group, which is expected to be scientifically fruitful. Arrangements have been made for Dr. R.P. Beukens of the Toronto Accelerator Group to extract the carbon compounds from Antarctic meteorite and lunar samples and to convert the compounds to CO2. During the past two years, a uranium-series dating method was developed for polar ice, which method is being applied to ice from the Allan Hills site, Byrd core, and the Beardsmore glacier.

Fireman, E. L.↗

The Advanced X-ray Astrophysics Facility instrument interface requirements

A variety of instruments will be placed at the focus of the Advanced X-ray Astrophysics Facility (AXAF) telescope, either by moving them into focus through the use of an instrument carousel or by moving the telescope assembly. Focal plane instrument categories under consideration for AXAF encompass high and moderate resolution X-ray cameras, X-ray spectrometers, and polarimeters; some of these instruments may require such consumables as a cryogen, in the case of solid state device cooling, or a gas, as in the case of proportional counters. Attention is presently given to interface requirements impacting on the maintenance that must be conducted over the 15-year service life of AXAF, and, especially, on the 'aspect solution' criteria that must be met to minimize stiffness stability criteria.

Weisskopf, M. C.↗