Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Local flow management/profile descent algorithm. Fuel-efficient, time-controlled profiles for the NASA TSRV airplane

The Local Flow Management/Profile Descent (LFM/PD) algorithm designed for the NASA Transport System Research Vehicle program is described. The algorithm provides fuel-efficient altitude and airspeed profiles consistent with ATC restrictions in a time-based metering environment over a fixed ground track. The model design constraints include accommodation of both published profile descent procedures and unpublished profile descents, incorporation of fuel efficiency as a flight profile criterion, operation within the performance capabilities of the Boeing 737-100 airplane with JT8D-7 engines, and conformity to standard air traffic navigation and control procedures. Holding and path stretching capabilities are included for long delay situations.

Groce, J. L.↗

Temperature and velocity profiles in sooting free boundary layer flames

Temperature and velocity profiles are presented for cyclohexane, n-heptane, and iso-octane free, laminar, boundary layer, sooting, diffusion flames. Temperatures are measured with 3 mil Pt/Pt-13 percent Rh thermocouples. Corrected gas temperatures are derived by performing an energy balance of convection to and radiation from the thermocouple bead incorporating the variation of air conductivity and platinum emissivity with temperature. Velocities are measured using laser doppler velocimetry techniques. Profiles are compared with previously reported analytic temperature and velocity fields. Comparison of theoretical and experimental temperature profiles suggests improvement in the analytical treatment is needed, which accounts more accurately for the local soot radiation. The velocity profiles are in good agreement, with the departure of the theory from observation partially due to the small fluctuations inherent in these free flows.

Ang, J. A.↗

Standard profiles of ozone from ground to 60 km obtained by combining satellite and ground based measurements

A study is reported based on four years of SBUV data and five years of published ozonesonde data. The Solar Backscatter Ultraviolet Experiment (SBUV), has been operating continuously since November 1978, providing some 1000 profiles per day. The data are of excellent quality from about 50 km down to the tropopause. By combining the satellite-derived data with ozonesonde data, a data base of standard ozone profiles and variance/covariance matrices has been developed, defining the observed variation of the atmospheric ozone around the mean profiles. Highlights of the data base are presented along with parameters of an analytical fit that describes the essential features of the data set. Although the data base was created specifically for use as a priori profiles for SBUV and Umkehr retrievals, it should be useful in other remote sensing applications and in modeling the UV radiation fields in the stratosphere. Another suggested application is in estimating ozone above the peak altitude of the ozone balloons.

Bhartia, P. K.↗

Comparison of vertical velocities analyzed by a numerical model and measured by a VHF wind profiler

The use of wind profilers for measuring vertical velocities in the troposphere and lower stratosphere is potentially of great interest for verification of forecasts, diagnosis of mesoscale circulations, and studies of wave motions. The studies of profiler vertical velocities to date have shown that the observed patterns of ascent and subsidence are reasonable when compared to the synoptic conditions. However, difficulties arise when a direct verification of the profiler vertical winds is sought. Since no other technique can measure the vertical velocities over the same height range and with the same claimed accuracy as the profilers, direct comparisons are impossible. The only alternative is to compare the measurements to analyzed vertical velocity fields. Here, researchers compare vertical measurements made with the SOUSY VHF radar over a period of 11 days at the beginning of November 1981 to the analyzed vertical velocities produced by the European Center for Medium-range Weather Forecasting (ECMWF) model for grid points near the radar site.

Larsen, M. F.↗

Comparison of reflectivity and wind profiles measured on 46.8 MHz and 430 MHz at the Arecibo Observatory

Comparisons of troposphere and stratosphere radar experiments at ultrahigh frequency (UHF) and very high frequency (VHF) were done at the Arecibo Observatory in April 1980 with the 430 MHz and 46.8 MHz radar. The velocity profiles measured on both frequencies with the Doppler beam swinging mode were compared. In general, the velocity profiles were equivalent. The VHF profile, however, shows more fluctuations with height than the UHF profile, although the latter was recorded with 150 m resolution instead of 300 m resolution on VHF.

Rottger, J.↗

Data communications and monitor for the Penn State University profiler network

The profiler network installed by the Department of Meteorology at Penn State University utilizes a microcomputer for network monitoring and control. The network consists of two VHF and one UHF wind profiling Doppler radars. Additional measurement systems added to the network include temperature and humidity profiling radiometers, sodar for boundary layer wind profiling and selected surface based baseline systems. Remote diagnostic capabilities were also implemented in the Penn State network. It is possible to remotely analyze many specific malfunctions of the transmitter or signal processor.

Peters, R. M.↗

Velocity profiles in laminar diffusion flames

Velocity profiles in vertical laminar diffusion flames were measured by using laser Doppler velocimetry (LDV). Four fuels were used: n-heptane, iso-octane, cyclohexane, and ethyl alcohol. The velocity profiles were similar for all the fuels, although there were some differences in the peak velocities. The data compared favorably with the theoretical velocity predictions. The differences could be attributed to errors in experimental positioning and in the prediction of temperature profiles. Error in the predicted temperature profiles are probably due to the difficulty in predicting the radiative heat losses from the flame.

Lyons, Valerie J.↗

An analysis of the vertical structure equation for arbitrary thermal profiles

The vertical structure equation is a singular Sturm-Liouville problem whose eigenfunctions describe the vertical dependence of the normal modes of the primitive equations linearized about a given thermal profile. The eigenvalues give the equivalent depths of the modes. The spectrum of the vertical structure equation and the appropriateness of various upper boundary conditions, both for arbitrary thermal profiles were studied. The results depend critically upon whether or not the thermal profile is such that the basic state atmosphere is bounded. In the case of a bounded atmosphere it is shown that the spectrum is always totally discrete, regardless of details of the thermal profile. For the barotropic equivalent depth, which corresponds to the lowest eigen value, upper and lower bounds which depend only on the surface temperature and the atmosphere height were obtained. All eigenfunctions are bounded, but always have unbounded first derivatives. It was proved that the commonly invoked upper boundary condition that vertical velocity must vanish as pressure tends to zero, as well as a number of alternative conditions, is well posed. It was concluded that the vertical structure equation always has a totally discrete spectrum under the assumptions implicit in the primitive equations.

Cohn, Stephen E.↗

Median density altitude profiles of the major ions in the central nightside Venus ionosphere

Altitude profiles of median values for total ion density, constituent ion densities, and the molecular ion group of the central nightside Venus ionosphere are presently derived from the Pioneer Venus retarding potential analyzer's measurements during the first five seasonal passages of the spacecraft through the nightside hemisphere. The altitude profiles for total ion density, constituent ions and the molecular ion group are compared with previously predicted profiles derived from numerical models in which the ionization source was O(+) ions transported from the dayside ionosphere and electron impact-produced ionization. The electron impact-produced profiles for O(+) is 2 orders of magnitude smaller than that observed.

Knudsen, William C.↗

Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983

A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

Fishman, Jack↗

A rapid change of the Hercules X-1 pulse profile and high-state duration

Her X-1 has been observed in the 13-180 keV energy range by the HEAO 1 A-4 Low-Energy Detectors during selected phases of the 35 d on-off cycle. During a pointing observation in September 1978, the pulse profile was observed to change continuously from its normal shape to an anomalous double-pulsed form. Moreover, at this time the main-on state, normally of the duration 10 d, was seen to terminate after only 7 d. Since such an anomalous pulse profile has also been reported by Truemper et al. in 1986 during a short-on state, three short-on states in the HEAO 1 data were also investigated. One short-on observation had the sensitivity to detect pulsing, and the observed profile also had an anomalous double-pulsed form. Current models for the 35 d cycle of Her X-1 have been examined, and a model with a neutron star undergoing free precession could not explain the sudden change of pulse profile within 20 hr at the end of a main-on state.

Soong, Yang↗

Dynamic loading of spur gears with linear or parabolic tooth profile modification

A computer simulation was conducted to investigate the effects of both linear and parabolic tooth profile modification on the dynamic response of low-contact-ratio spur gears. The effect of the total amount of modification and the length of the modification zone were studied at various loads and speeds to find the optimal profile modification for minimal dynamic loading. Design charts consisting of normalized maximum dynamic load curves were generated for gear systems operated at various loads and with different tooth profile modification. An optimum profile modification can be determined from these design charts to minimize the dynamic loads of spur gear systems.

Lin, Hsiang Hsi↗

Atmospheric profiling of water vapour with a 20.5-23.5 GHz autocorrelation radiometer

A tropospheric water vapor profiling system is presented. The hardware consists of an upward looking radiometer (CORRAD) deployed at ground level. The CORRAD measures the autocorrelation of the downwelling thermal emission from the atmosphere over a passband of 20.5 to 23.5 GHz out to a maximum time delay of 6.1 ns. This produces 100 MHz resolution imaging of the complete emission spectrum about the 22.235 GHz water vapor resonance line. The 31 equivalent frequency channels produced by Fourier transformation of the data provide additional constraints on the inversion process required to estimate the water vapor profile, as compared to standard 2 to 5 frequency channel profiling systems. The CORRAD hardware is described, and radiometer and radiosonde profiles are compared.

Ruff, C. S.↗

Numerical simulations of the profile properties of undeformed first-year sea ice during the growth season

A model is presented for estimating salinity profiles for the first-year sea ice during the growth season, in which ice growth equations were coupled with salt entrapment and brine drainage relations to obtain the relationship between the initial ice salinity and the ice-growth velocity and seawater salinity, as well as the subsequent drainage of brine from the ice. The results obtained were found to be in reasonable agreement with field observations in that they showed characteristic C-shaped profiles similar to natural profiles. The average ice salinity values were also in reasonable agreement with field data. The predicted ice property profiles give composite plate properties that are significantly different from bulk property estimates that would result by assuming that sea ice could be represented as a homogeneous plate.

Cox, G. F. N.↗

Range profiles and images of a loaded straight wire

The range-profiles and images of a straight wire without and with lumped impedance loading are discussed and demonstrated. The scattering mechanisms of a straight wire are qualitatively analyzed using the method of moments. Plots of range profiles at different aspect angles show that surface traveling waves are important scattering mechanisms of a straight wire. The presence of traveling wave makes ringlike artifacts appear in the reconstructed images. It was found that lumped impedance loading can effectively distort the range profiles and microwave images of a wire scatterer. In addition, randomly varied reactive loading can generate random peaks in the range profiles.

Li, Hsueh-Jyh↗

An analysis of the vertical structure equation for arbitrary thermal profiles

The vertical structure equation is a singular Sturm-Liouville problem whose eigenfunctions describe the vertical dependence of the normal modes of the primitive equations linearized about a given thermal profile. The eigenvalues give the equivalent depths of the modes. The spectrum of the vertical structure equation and the appropriateness of various upper boundary conditions, both for arbitrary thermal profiles were studied. The results depend critically upon whether or not the thermal profile is such that the basic state atmosphere is bounded. In the case of a bounded atmosphere it is shown that the spectrum is always totally discrete, regardless of details of the thermal profile. For the barotropic equivalent depth, which corresponds to the lowest eigen value, upper and lower bounds which depend only on the surface temperature and the atmosphere height were obtained. All eigenfunctions are bounded, but always have unbounded first derivatives. It was proved that the commonly invoked upper boundary condition that vertical velocity must vanish as pressure tends to zero, as well as a number of alternative conditions, is well posed. It was concluded that the vertical structure equation always has a totally discrete spectrum under the assumptions implicit in the primitive equations.

Cohn, Stephen E.↗

The mean ozone profile and its temperature sensitivity in the upper stratosphere and lower mesosphere - An analysis of LIMS observations

Multiple simultaneous LIMS (Limb Infrared Monitor of the Stratosphere) observations of both O3 and temperature T in the upper stratosphere and lower mesosphere are analyzed to derive O3-T correlations for comparisons with model calculations. The zonally averaged O3 profile is compared with results from a simplified photochemical model that assumes O3 to be in a photochemical steady state. The model profile is systematically lower than the observed profile. Key parameters are identified in which changes can systematically increase the O3 profile in both the stratosphere and the mesosphere. The LIMS-derived values for the sensitivity of O3 to changes in T are compared with equilibrium model calculations which include the T-driven opacity feedback effect on photodissociation rate constants. The theoretical O3 response to temperature perturbations is investigated. It is shown how the O3-T sensitivity coefficient is affected by zonal and vertical advection terms as well as by the photochemical coupling between O3 and T.

Froidevaux, Lucien↗

Measurement of stratospheric HOCl - Concentration profiles, including diurnal variation

Determinations have been made of concentration profiles of HOCl in the earth's stratosphere, including the diurnal variation. Measurements of the rotational Q2 branch at 99.5/cm and of five RR(J3) transitions between 143 and 159/cm were made using far-infrared thermal emission spectroscopy. The spectra were obtained during a balloon flight of the FIRS 2 far-infrared Fourier-transform spectrometer and telescope from Palestine, Texas on May 12-13, 1988. From these measurements, altitude profiles of HOCl from 23 to 42 km are obtained. Daytime and nighttime average profiles of HOCl, as well as measurements on a 30-min time scale through the sunset transition at a single (35 km) altitude are presented. The measured profiles are lower than the current predictions from several modeling groups by a factor of approximately 0.6.

Chance, K. V.↗