Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Measurement-informed Dynamic Aggregation of Distribution Systems

This paper proposes a measurement-informed dynamic aggregation methodology in order to create equivalent representations of distribution systems that are compatible with large-scale transmission analysis. By optimizing an equivalent feeder parameters using time-series measurements of active power, reactive power, and voltage at the Point of Interconnection (POI), the approach yields simplified yet dynamically accurate equivalents. Implemented in PSCAD with models of photovoltaic–battery systems, three-phase motors, and static loads, the method employs hybrid differential evolution and bounded least-squares optimization laying the foundation for for real-time state estimation and optimized sensor placement in distribution networks.

Ahmed, Kazi Ishrak [University of Tennessee, Knoxv↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability and Fidelity of Power-Hardware-in-the-Loop Using NREL's CGI

The presentation focuses on dynamic analysis of power hardware-in-the-loop (PHIL) experiments using National Renewable Energy Laboratory Flatirons Campus' grid simulator - 7MVA Controllable Grid Interface (CGI). A control diagram of typical PHIL experiment is described, and transfer functions of critical components are explained. An impedance-based definition of PHIL experiment bandwidth is defined using open loop transfer functions of the system. Further an example resistive divider circuit is introduced that is used to explain implication of PHIL on accuracy of simulation by comparing measured results against ideal expected signals. At the end the real-life PHIL simulation using Maui power system model is described showing various oscillation modes observed and discussing the meaning of these in context of dynamic bandwidth of simulation.

grid simulator↗

Dynamic voltage and frequency scaling based on memory channel slack

A processing system scales power to memory and memory channels based on identifying causes of stalls of threads of a wavefront. If the cause is other than an outstanding memory request, the processing system throttles power to the memory to save power. If the stall is due to memory stalls for a subset of the memory channels servicing memory access requests for threads of a wavefront, the processing system adjusts power of the memory channels servicing memory access request for the wavefront based on the subset. By boosting power to the subset of channels, the processing system enables the wavefront to complete processing more quickly, resulting in increased processing speed. Conversely, by throttling power to the remainder of channels, the processing system saves power without affecting processing speed.

Das, Shomit N.↗

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Techno-Economic Optimization of Advanced Energy Plants with Integrated Thermal, Mechanical, and Electro-Chemical Storage (Final Report)

The increasing use of renewable energy sources is leading to increased cycling of fossil-fueled power plants (FFPP) that are designed to operate at base-loaded conditions. Integrating energy storage facilities with the FFPPs can be helpful in reducing load-following operation of FFPPs. Decentralized deployment of energy storage facilities at the FFPP level has considerable advantages due to possibilities of smaller storage capacities, immediate benefits realized by the host power plant due to the increase in the efficiency, cleaner emission and higher plant life to name a few. Most importantly, deployment at the FFPP level can exploit the existing equipment items and facilities at the host power plant, thus reducing the CAPEX and reducing the storage capacity. However, realization of these benefits will critically depend on novel configuration/integration strategies with the least impact on the power plant operation and its configuration. Furthermore, dynamics of the entire integrated system including both the FFPP and the storage technologies must be taken into account to obtain the cost-optimal solution. With these motivations, the objective of this project was to complete a focused evaluation of decentralized deployments of energy storage facilities at the FFPP level. Promising thermal, chemical, mechanical, and electro-chemical storage technologies were evaluated with due consideration of their transient response to obtain various optimal system concepts that can minimize the levelized cost of storage. For thermal storage, cryogenic energy storage along with high temperature heat storage in molten salt as well as phase change material were evaluated. For mechanical storage, cryogenic air storage and pumped hydro storages were evaluated. For chemical storage, hydrogen storage was evaluated. For electrochemical storage, the team evaluated sodium sulfur, vanadium redox flow battery as well as Li-ion batteries. Integration of these storage technologies with the natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants was considered. Six technologies, namely molten salt, cryogenics, compressed air, pumped hydro, H2 storage and Li-ion battery storage, were downselected based on their levelized cost of storage. It was observed that the ranking of the optimal storage technology can differ based on the host power plant technology even when same demand/supply/price profile for electricity are considered. It was also observed that as the variability in power demand varies, the ranking of the optimal storage technologies vary. However, for the same demand and LMP profile, top six optimal storage technologies for NGCC vs SCPC plants did not differ much even though LCOS for the same technology and optimal size of a given storage technology did differ. Detailed techno-economic assessment of these six technologies was undertaken.

01 COAL, LIGNITE, AND PEAT↗

Dynamical System Scaling of a Thermocline Thermal Storage System in the Thermal Energy Distribution System (TEDS) Facility

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility in development that aims to emulate the daily interactions among power production industry systems and be capable of receiving real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect the laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (a methodology that enables systems to scale and project or extrapolate datasets to desired environments while conserving the observed transient behavior based on first principles) was applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System. The thermocline system was successfully scaled and a test case was conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facility. The accelerated data were determined as able to conserve the amount of energy stored and the associated test boundary conditions were charge line maximum temperature, charge line velocity, and thermocline maximum temperature at 354 °C, 0.458 m/s, and 418 °C, respectively. The research results represented a case that required signals to be accelerated without altering the stored energy.

Yoshiura, Ramon (ORCID:0000000319781313)↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

A safe reinforcement learning algorithm for supervisory control of power plants

Traditional control theory-based methods require tailored engineering for each system and constant fine-tuning. In power plant control, one often needs to obtain a precise representation of the system dynamics and carefully design the control scheme accordingly. Model-free Reinforcement learning (RL) has emerged as a promising solution for control tasks due to its ability to learn from trial-and-error interactions with the environment. It eliminates the need for explicitly modeling the environment’s dynamics, which is potentially inaccurate. However, the direct imposition of state constraints in power plant control raises challenges for standard RL methods. To address this, we propose a chance-constrained RL algorithm based on Proximal Policy Optimization for supervisory control. Our method employs Lagrangian relaxation to convert the constrained optimization problem into an unconstrained objective, where trainable Lagrange multipliers enforce the state constraints. In conclusion, our approach achieves the smallest distance of violation and violation rate in a load-follow maneuver for an advanced Nuclear Power Plant design.

constrained optimization↗

Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks

Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.

33 ADVANCED PROPULSION SYSTEMS↗

Commissioning Status of the Linac for the Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams will be completed in late 2021. Here, we report here on the current efforts to commission the first stages of the 200-MeV/u superconducting, continuous wave heavy-ion linac. The statuses of the cryogenic plant and its distribution system, the accelerator cryomodule commissioning and operations, the ion source and front end transport development, the radio-frequency quadrupole commissioning, and then beam dynamics development to support high-power operation are reviewed. Plans for commissioning the remainder of the linac systems are presented.

43 PARTICLE ACCELERATORS↗

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗

Effect of Quartz Aperture Covers on the Fluid Dynamics and Thermal Efficiency of Falling Particle Receivers

Falling particle receivers are an emerging technology for use in concentrating solar power systems. In this paper, quartz half-shells are investigated for use as full or partial aperture covers to reduce receiver thermal losses. Quartz half-shell aperture covers offer the ability to minimally interfere with incoming solar radiation from the heliostat field while obstructing thermal radiation and advection from leaving the receiver cavity. The fluid dynamics and heat transfer of a receiver subdomain and surrounding air are modeled using ANSYS®FLUENT We compare the percentage of total incident solar power lost due to conduction through the receiver walls, advective losses through the aperture, and radiation exiting the aperture. Contrary to expected outcomes, results show that quartz aperture covers can increase radiative losses and result in modest to nonexistent reductions in advective losses. The increased radiative losses are driven by elevated quartz half-shell temperatures and have the potential to be mitigated by active cooling and/or material selection. Quartz half-shell total transmissivity was measured experimentally using a radiometer and the National Solar Thermal Test Facility heliostat field with values up to 0.97 ± 0.01. Quartz half-shell aperture covers did not yield expected efficiency gains in numerical results due to increased radiative losses, but efficiency improvement in some numerical results and the performance of quartz half-shells subject to concentrated solar radiation suggest that quartz half-shell aperture covers should be investigated further.

14 SOLAR ENERGY↗

Enhancing Power Grid Resilience with Causal Loops Diagram and Bayesian Networks

Enhancing power grid resilience through improved analysis and planning of Distributed Energy Resources is a key for power system planner. This paper explores the integration of Causal Loop Diagrams (CLDs) and Bayesian Networks (BNs) for enhancing resilience in power systems, focusing on Distributed Energy Resources (DER) planning. By automating CLD analysis in Python's matplotlib, we present a tool for rapid model validation and structural accuracy, crucial for power system planners. This hybrid approach utilizes BNs for inferential depth and CLDs for dynamic system modeling, offering a comprehensive framework for policy formulation and collaborative strategy development against disruptions. Here, we highlight the tool's capability to identify and analyze interconnected feedback loops, facilitating a deeper understanding of DER integration's impact on network resilience. This work aims to bridge quantitative analysis and qualitative insights, addressing the limitations of each method while providing a robust model for power system resilience assessment.

14 SOLAR ENERGY↗

AI-Guided Reasoning-Based Operator Support System for the Nuclear Power Plant Management

The Decision-making process in the Nuclear Power Plant (NPP) control room faces some challenges: operator incomplete knowledge, insufficient time for responding to the highly dynamic events, and a large number of indicators to monitor. Because of the complexity of the NPP system, it is hard to pre-plan all the failures/mitigative actions. An intelligent operator support system is vital to mitigate these shortcomings. In this paper, an AI declarative approach (Answer Set Programming (ASP)) is employed to represent our knowledge of the nuclear power plant in the form of logic rules. This represented knowledge is structured to form a reasoning-based operator support system. When an incident occurs, this ASP-based reasoning support system is demonstrated to be capable of fault identification (diagnosis), informing the operator of different scenarios and consequences, and generating the control options (decision making).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A reforecasting-based dynamic reserve estimation for variable renewable generation and demand uncertainty

The installed capacity of renewables-based energy sources has been increasing in traditional power systems. In order to accommodate the increased variability and uncertainty associated with the deeper penetration of renewable sources like solar and wind, adjusted amounts of dynamic reserve are needed. Although probabilistic dynamic reserve estimation methods have been previously developed, most of them consider the uncertainty to be represented by parametric density functions that tend to perform poorly under extreme events and, moreover, neglect uncertainty introduced by the forecasting model itself. Toward addressing these limitations, this work presents, for the first time, a dynamic reserve estimation method for flexibility that incorporates nonparametric density estimation and a machine learning based reforecasting to provide a day-ahead prediction of the mean and spread of uncertainty around the base forecast. The prediction is, in turn, used to estimate the up and down reserve relative to the base forecast. Here, the present method takes various endogenous and exogenous features, including the calendar variables, as input to estimate the day-ahead reserve. Using a combination of reforecasting and dynamic reserve estimation techniques, the method is shown to adjust better to the dynamic nature of reserve requirements providing only what is needed to accommodate the expected deviations. Considering California Independent System Operator (CAISO) solar, wind and load data over an 18 month period, up to 67% reduction in the amount of reserve capacity needed for a one day reserve and reserve penalty for solar uncertainty is demonstrated. Additionally, the risk of reserve insufficiency in meeting the net demand is reduced by 20% with the proposed method.

14 SOLAR ENERGY↗