Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Development of pseudo-random binary gratings and arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable flair. A major difficulty in using surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. Therefore, accurate calibration of profilometers, the understanding of their MTF limitations, and cross calibration between tools represents a considerable challenge for quantitative optical metrology. In previous work the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudo-random (BPR) gratings. Here, they present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocol. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat Power Spectrum Density (PSD). Three different BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Figure 1 shows the fabrication sequence. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. Figure 2 shows representative scanning probe height data for the 400 nm BPR sample. Figure 2 shows the raw Power Spectral Density for 5 different objectives. They demonstrate that the two dimensional BPR array is a very effective calibration standard. However, departures from ideal, such as square sidewall, and uniform etch depth ultimately can limit the accuracy of the calibration. The effects of fabrication imperfections on the efficiency of calibration will be discussed.

36 MATERIALS SCIENCE↗

PCG method with Strang’s circulant preconditioner for Hermitian positive definite linear system in Riesz space fractional advection–dispersion equations

In this paper, preconditioned conjugate gradient (PCG) method with Strang’s circulant preconditioner is investigated to solve the Hermitian positive definite linear systems, which is result from the Crank–Nicolson (C-N) finite difference scheme with the weighted and shifted Grünwald difference (WSGD) operators to discretize the Riesz space fractional advection–dispersion equation (RSFADE). We show that the spectrum of the preconditioned matrix is clustered around 1, and the singular values of the preconditioned matrix are uniformly bounded away from zero under a certain condition, respectively; hence the PCG method, when applied to solving the preconditioned system, converges superlinearly. Moreover, the complexity in each iteration of the PCG method is O(Nlog N) via using the fast Fourier transforms, where N is the matrix size. Numerical experiments are included to demonstrate the effectiveness of our approach.

97 MATHEMATICS AND COMPUTING↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geometry of sets of quantum maps: A generic positive map acting on a high-dimensional system is not completely positive

We investigate the set (a) of positive, trace preserving maps acting on density matrices of size N and a sequence of its nested subsets: the sets of maps which are (b) decomposable, (c) completely positive, and (d) extended by identity impose positive partial transpose and (e) are superpositive. Working with the Hilbert-Schmidt (Euclidean) measure, we derive tight explicit two-sided bounds for the volumes of all five sets. A sample consequence is the fact that, as N increases, a generic positive map becomes not decomposable and, a fortiori, not completely positive. Due to the Jamiolkowski isomorphism, the results obtained for quantum maps are closely connected to similar relations between the volume of the set of quantum states and the volumes of its subsets (such as states with positive partial transpose or separable states) or supersets. Our approach depends on the systematic use of duality to derive quantitative estimates and on various tools of classical convexity, high-dimensional probability, and geometry of Banach spaces, some of which are not standard.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast tomographic methods for the tokamak ISTTOK

The achievement of long duration, alternating current discharges on the tokamak IST-TOK requires a real-time plasma position control system. The plasma position determination based on magnetic probes system has been found to be inadequate during the current inversion due to the reduced plasma current. A tomography diagnostic has been therefore installed to supply the required feedback to the control system. Several tomographic methods are available for soft X-ray or bolo-metric tomography, among which the Cormack and Neural networks methods stand out due to their inherent speed of up to 1000 reconstructions per second, with currently available technology. This paper discusses the application of these algorithms on fusion devices while comparing performance and reliability of the results. It has been found that although the Cormack based inversion proved to be faster, the neural networks reconstruction has fewer artifacts and is more accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method and apparatus for animal positioning in imaging systems

An apparatus for imaging an animal includes a first mounting surface, a bed sized to support the animal and releasably secured to or integral with the first mounting surface. The apparatus also includes a plurality of straps, each having a first end in a fixed position relative to the bed and a second end for tightening around a limb of the animal. A method for in-vivo imaging of an animal includes providing an animal that has limbs, providing a first mounting surface, and providing a bed removably secured to or integral with the mounting surface and sized to support the animal as well as being coupled to a plurality of straps. The method also includes placing the animal on the bed between the plurality of straps and tightening at least two of the plurality of straps around at least two of the limbs such that the animal is substantially secured in place relative to the bed.

47 OTHER INSTRUMENTATION↗

Time of flight elastic recoil detection analysis with a position sensitive detector

A position sensitive detection system based on the microchannel plate detector has been constructed and installed at the existing time of flight (TOF) spectrometer in order to perform a kinematic correction and improve the surface time/depth resolution of elastic recoil detection analysis (ERDA) system. The position resolution of the detector has been tested for different types of ions and anode voltages. TOF spectra of recoiled O ions from SiO{sub 2} and F from CaF{sub 2} were collected in coincidence with position sensitive detector signal. Kinematic correction of TOF spectra improved surface time/depth resolution by {approx}20% for our system; however even higher improvements could be obtained in larger solid angle TOF-ERDA systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum systems with position-dependent mass and spin-orbit interaction via Rashba and Dresselhaus terms

We consider a particle with spin 1/2 with position-dependent mass moving in a plane. Considering separately Rashba and Dresselhaus spin-orbit interactions, we write down the Hamiltonian for this problem and solve it for Dirichlet boundary conditions. Our radial wavefunctions have two contributions: homogeneous ones which are written as Bessel functions of non-integer orders—that depend on angular momentum m—and particular solutions which are obtained after decoupling the non-homogeneous system. In this process, we find non-homogeneous Bessel equation, Laguerre, as well as biconfluent Heun equation. We also present the probability densities for m = 0, 1, 2 in an annular quantum well. Our results indicate that the background as well as the spin-orbit interaction naturally splits the spinor components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Displacement operator for quantum systems with position-dependent mass

A translation operator is introduced to describe the quantum dynamics of a position-dependent mass particle in a null or constant potential. From this operator, we obtain a generalized form of the momentum operator as well as a unique commutation relation for x and p{sub {gamma}}. Such a formalism naturally leads to a Schroedinger-like equation that is reminiscent of wave equations typically used to model electrons with position-dependent (effective) masses propagating through abrupt interfaces in semiconductor heterostructures. The distinctive features of our approach are demonstrated through analytical solutions calculated for particles under null and constant potentials like infinite wells in one and two dimensions and potential barriers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fusion hindrance for the positive Q -value system C 12 + Si 30

Here, the fusion reaction 12 C+ 30 Si is a link between heavier cases studied in recent years, and the light heavy-ion systems, e.g., 12 C+ 12 C, 16 O+ 16 O that have a prominent role in the dynamics of stellar evolution. 12 C+ 30 Si fusion itself is not a relevant process for astrophysics, but it is important to establish its behavior below the barrier, where couplings to low-lying collective modes and the hindrance phenomenon may determine the cross sections. The excitation function is presently completely unknown below the barrier for the 12 C+ 30 Si reaction, thus no reliable extrapolation into the astrophysical regime for the C+C and O+O cases can be performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Modal Sensitivity to Operating Conditions for Damping Control in Power Systems

Small signal stability is an inherent characteristic of dynamic systems such as power systems. Pole positioning through power system stabilizers (PSS) is often used for improving damping in power systems. A well-designed PSS can be very effective in damping oscillations, especially local oscillations. However, designing PSSs for inter-area oscillations has been a very challenging task due to time-varying operating conditions affecting the characteristics of inter-area oscillations. This paper explores the sensitivity relationship between oscillations and operating conditions and employs the relationship to derive recommendations for operator’s actions to adjust operating conditions so as to improve damping. Low damping is usually considered to be a result of heavy power transfer in long distance. Studies in this paper show that this generally holds true while locations have significant impact on damping of oscillations. Therefore it is important to consider locations in deriving recommendations. This paper proposes the concept of relative modal sensitivity and presents the application of relative modal sensitivity to derive recommendations for operator’s action in damping control.

Huang, Zhenyu↗

: Small Animal SPECT/CT System Based on Position-Sensitive Semiconductor Detectors

We developed a SPECT/CT system for small-animal imaging utilizing a mechanically cooled, position-sensitive germanium detector for the SPECT camera. The detector offers better energy resolution than any other detector previously used for SPECT and demonstrates dual-isotope imaging capabilities superior to that of current commercial small-animal SPECT systems. We also explored a unique SPECT camera configuration consisting of a silicon detector and germanium detector stacked one behind the other and located behind a multi-pinhole collimator. This scheme is intended for imaging iodine-123 radiotracer distributions, with the ~30 keV x-ray emissions detected in the silicon detector and the 159 keV gamma-ray emissions passing through the silicon and detected in the germanium detector. Image reconstruction methods for combining this multi-energy, multi-magnification data were developed and it was shown that inclusion of the silicon data reduced artifacts in comparison to the germanium data alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery

Purpose: The optically guided target localization had been developed for linear accelerator based stereotactic radiosurgery (SRS). Unlike the traditional laser localization, the optical guided target localization utilizes a digital system to position patient. Although the system has been proven accurate and robust, it takes away the capability of physicist to directly double check the target position prior to irradiation. Any error from system calibration, data transformation, or head ring position maintenance will not be caught. The purpose of this work is to investigate the possibility of using cone-beam CT (CBCT) to double check the optically guided SRS target localization and reposition the patient. Methods: A SRS quality assurance (QA) phantom was used in the study. The phantom mounted with SRS head frame was scanned by computer tomography (CT) and planned according to the SRS radiation treatment planning process. A target isocenter is defined and transferred to the optically guided target localization system. The phantom was then transported to the linear accelerator room and localized at the initial position agreed by the optically guided target localization system and the CBCT system. Tests were conducted by moving/rotating the phantom to a set of preset offsets and taking CBCT images. Shifts detected by CBCT were compared with the preset offsets. Agreements between them were studied to see how well the CBCT was in discovering the optically guided target localization error. Results: Experiment results demonstrated good agreement between the CBCT detected phantom shift and the preset offset, when the offset is above 1 mm shift or 0.2 degree rotation. Offset less than 1 mm shift or 0.2 degree rotation was not detectable by CBCT. Conclusions: The study concludes that the CBCT is able to discover the optically guided target localization error due to the system calibration or had ring migration. It is a valuable second check tool for SRS target localization quality assurance. The accuracy of CBCT in estimating patient positioning deviation satisfies the SRS procedures with generous tumor size and margin that can tolerate 1 mm or 0.2 degree accuracy. This avoids sending patient home without treatment. CBCT can be neither used as a primary SRS target localization nor can it be used to reposition the patient that cannot tolerate 1 mm shift or 0.2 degree rotation.

60 APPLIED LIFE SCIENCES↗

Algebraic solutions of shape-invariant position-dependent effective mass systems

Keeping in view the ordering ambiguity that arises due to the presence of position-dependent effective mass in the kinetic energy term of the Hamiltonian, a general scheme for obtaining algebraic solutions of quantum mechanical systems with position-dependent effective mass is discussed. We quantize the Hamiltonian of the pertaining system by using symmetric ordering of the operators concerning momentum and the spatially varying mass, initially proposed by von Roos and Lévy-Leblond. The algebraic method, used to obtain the solutions, is based on the concepts of supersymmetric quantum mechanics and shape invariance. In order to exemplify the general formalism a class of non-linear oscillators has been considered. This class includes the particular example of a one-dimensional oscillator with different position-dependent effective mass profiles. Explicit expressions for the eigenenergies and eigenfunctions in terms of generalized Hermite polynomials are presented. Moreover, properties of these modified Hermite polynomials, like existence of generating function and recurrence relations among the polynomials have also been studied. Furthermore, it has been shown that in the harmonic limit, all the results for the linear harmonic oscillator are recovered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗