Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

43 PARTICLE ACCELERATORS↗

Multipath effects in a Global Positioning Satellite system receiver

This study, as a part of a large continuing investigation being conducted by the Communications Systems Branch of the Information and Electronic Systems Laboratory at the Marshall Space Flight Center, was undertaken to explore the multipath response characteristics of a particular Global Positioning Satellite (GPS) receiver which was available in the laboratory at the beginning and throughout the entirety of the study, and to develop a suitable regime of experimental procedure which can be applied to other state-of-the-art GPS receivers in the larger investigation.

Mcdonald, Malcolm W.↗

Stripline Block Sensor System

The Long Baseline Neutrino Facility requires a secondary sensor system to aid in the installation and replacement of the stripline blocks. These blocks are responsible for delivering large amounts of current to the horn and must be installed with high precision to avoid possible physical damage. There are many constraints due to the modules' surroundings, such as small clearances and a highly radioactive environment. Existing systems have already been implemented within the process; however, these systems offer limited information, leaving much risk during operations. This calls for a sufficiently accurate sensor system, which has a small space requirement and provides valuable information throughout the replacement period. A variety of methods and technologies were explored to provide an applicable approach to the issue. The proposed solution consisted of the use of retroreflective and target, however, it cannot provide positional feedback throughout the entire process. A proposed alternative utilizes a three-dimensional indoor positioning system to provide the operator with real-time positioning and rotational information. Sensors placed on the module and stripline would communicate with fixed receivers surrounding the target hall to provide precise positional feedback. However, this solution may still contain line-of-sight issues as well as installation complications due to the radioactive environment. Future work would consist of finding vendors capable of providing technology that fits our constraints, proof of concept tests for both solutions, implementation planning, and trials within the target hall itself. Due to its ability to provide continuous positional and rotational feedback, the indoor positioning system is the most suitable solution for accurately installing the stripline block.

Espinoza, David [Unlisted, US]↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance.

43 PARTICLE ACCELERATORS↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Codeless GPS Applications to Multi-Path: CGAMP

Cordless Global Positioning System (GPS) Applications to Multi-Path (CGAMP) is meeting the challenge of exploiting the L-band signals from the Global Positioning System (GPS) satellites for the measurement of the impulse response of radio transmission channels over space-Earth paths. This approach was originally suggested by E. K. Smith and has been pursued by J. Lemmon, without an affordable implementation being identifiable. In addition to the high cost of a suitable P code correlating GPS receiver, there is also the major impediment of the often announced Department of Defense policy of selective availability/anti-spoof (SA/AS) that clouds reliable access to the wideband (20 MHz) P channel of the GPS signals without cryptographic access. A technique proposed by MacDoran utilizes codeless methods for exploiting the P channel signals implemented by the use of a pair of antennas and cross correlation signal detection.

Macdoran, P. F.↗

High precision GPS orbit determination using March 1985 demonstration data

Preliminary orbit determination for satellites in the U.S. Department of Defense's Global Positioning System has been performed using GPS carrier phase data collected in March-April 1985 at 10 sites in the continental United States. The data were analyzed using a new data processing software package called GIPSY (GPS Inferred Positioning SYstem) and with existing covariance analysis software. Data from one day have been processed with average formal position errors of 1.4 to 3.6 meters. The true errors are probably somewhat larger. Covariance results are presented which suggest that the orbits can be obtained with formal errors under 2 meters after certain software issues are resolved.

Bertiger, W.↗

Survey Parameters and Availability of Low-level Aeromagnetic Data for Geomagnetic Field Modelling

Since aeromagnetic surveying started immediately after World War II, a considerable area of the earth's surface both onshore (in excess of 25 million sq. km) has been magnetically surveyed. For about the first 15 years or so, fluxgate magnetometers were employed in aeromagnetic surveys, but the introduction of proton free-precession magnetometers resulted in absolute readings being recorded. Proton precession magnetometers have now been replaced to a large extent by the more sensitive optical absorption magnetometers. Some care has to be taken to calibrate aeromagnetic survey systems and this is best done using a calibration range tied to a magnetic observatory so that accuracies of 10nT or better are achieved for the total field values recorded. Survey navigation has always posed a problem for aeromagnetic surveys, especially offshore. Over land, vertically pointed 35 mm cameras were initially used to recover the aircraft track using a combination of aerial photos and topographic maps. Over featureless areas, it was necessary to utilize existing electronic positioning systems such as Loran C or set up special navigation systems. The advent of the satellite-based Global Positioning Systems (GPS) has to a larger extent solved the navigational problem because there is now almost continuous worldwide coverage to 10 m accuracy in the differential mode. The resultant aeromagnetic data is normally compiled into contour maps in which the diurnal variation and aircraft heading effects are removed. The resultant digital data are normally made publicly available both in gridded and profile form along with the published contour maps. Most aeromagnetic coverage has been obtained in the developed western countries, but elsewhere a considerable amount of surveying has been carried out; as an example, some 80 percent of Africa has been surveyed mostly as a result of aid programs. The data is usually held by the national geological survey or equivalent organizations, but in a number of cases the data (e.g., for the Magnetic Anomaly Map of North America) is also held by the World Data Centres.

Hood, Peter↗

Get the Picture?

Positive Systems has worked in conjunction with Stennis Space Center to design the ADAR System 5500. This is a four-band airborne digital imaging system used to capture multispectral imagery similar to that available from satellite platforms such as Landsat, SPOT and the new generation of high resolution satellites. Positive Systems has provided remote sensing services for the development of digital aerial camera systems and software for commercial aerial imaging applications.

Source record↗

A Planar Source of Atmospheric-Pressure Plasma Jet

In a single-barrier discharge with voltage sharpening and low gas consumption (up to 1 L/min), plane atmospheric pressure plasma jets with a width of up to 3 cm and length of up to 4 cm in air are formed in the slit geometry of the discharge zone. The energy, temperature, and spectral characteristics of the obtained jets have been measured. The radiation spectrum contains intense maxima corresponding to vibrational transitions of the second positive system of molecular nitrogen N{sub 2} (C{sup 3}Π{sub u} → B{sup 3}Π{sub g}) and comparatively weak transition lines of the first positive system of the N{sub 2}{sup +} ion (B{sup 2}Σ{sub u}{sup +} → X{sup 2}Σ{sub g}). By an example of inactivation of the Staphylococcus aureus culture (strain ATCC 209), it is shown that plasma is a source of chemically active particles providing the inactivation of microorganisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-hardened fast acquisition/weak signal tracking system and method

A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.

Winternitz, Luke↗

Cancellation of residual spacecraft accelerations for zero-G space physics experiments

The Drop Dynamics Module houses an acoustic positioning system which counteracts the effects of small accelerations of a spacecraft and thus allows long-term study of free-floating materials such as liquid drops. The acoustic positioning system provides an acoustic 'well' in the center of the experiment chamber. Data collection is by cinematographic photography. The module subsystems are discussed.

Stephens, J. B.↗

Measurement of Temperature and Density Profiles of the Plasma at PR-2 Facility

A new system of probe diagnostics at linear plasma simulator PR-2 is described, allowing us to measure the profiles of plasma temperature and density in different cross sections of the plasma column. The Langmuir probe fixed to the movable part of the two-coordinate positioning system built into the PR-2 passes the region of the discharge area during the process of measuring plasma parameters. The overall dimensions of the positioning system make it possible to mount electrical probes (magnetic probes, optical fibers, and other diagnostic equipment) covering almost the entire volume of the vacuum chamber between the magnetic mirrors of the device. We present the measurement results of local plasma parameters of the beam-plasma discharge (BPD) for different values of the input power and working gas pressure. The boundaries of appearance of discharge of three types were determined: the diffusive BPD mode, the BPD mode, and the arc mode. Dependences of the plasma concentration and temperature on the input power for different values of pressure have been also determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-A-9A-05: Initial Setup Accuracy Comparison Between Frame-Based and Frameless Stereotactic Radiosurgery

Purpose: To evaluate initial setup accuracy for stereotactic radiosurgery (SRS) between Brainlab frame-based and frameless immobilization system, also to discern the magnitude frameless system has on setup parameters. Methods: The correction shifts from the original setup were compared for total 157 SRS cranial treatments (69 frame-based vs. 88 frameless). All treatments were performed on a Novalis linac with ExacTrac positioning system. Localization box with isocenter overlay was used for initial setup and correction shift was determined by ExacTrac 6D auto-fusion to achieve submillimeter accuracy for treatment. For frameless treatments, mean time interval between simulation and treatment was 5.7 days (range 0–13). Pearson Chi-Square was used for univariate analysis. Results: The correctional radial shifts (mean±STD, median) for the frame and frameless system measured by ExacTrac were 1.2±1.2mm, 1.1mm and 3.1±3.3mm, 2.0mm, respectively. Treatments with frameless system had a radial shift >2mm more often than those with frames (51.1% vs. 2.9%; p<.0001). To achieve submillimeter accuracy, 85.5% frame-based treatments did not require shift and only 23.9% frameless treatment could succeed with initial setup. There was no statistical significant system offset observed in any direction for either system. For frameless treatments, those treated ≥ 3 days from simulation had statistically higher rates of radial shifts between 1–2mm and >2mm compared to patients treated in a shorter amount of time from simulation (34.3% and 56.7% vs. 28.6% and 33.3%, respectively; p=0.006). Conclusion: Although image-guided positioning system can also achieve submillimeter accuracy for frameless system, users should be cautious regarding the inherent uncertainty of its capability of immobilization. A proper quality assurance procedure for frameless mask manufacturing and a protocol for intra-fraction imaging verification will be crucial for frameless system. Time interval between simulation and treatment was influential to initial setup accuracy. A shorter time frame for frameless SRS treatment could be helpful in minimizing uncertainties in localization.

60 APPLIED LIFE SCIENCES↗

Fusion hindrance for a positive Q-value system

An excitation function for the fusion reaction {sup 28}Si + {sup 30}Si (Q=14.3MeV) has been measured down to 40{mu}b. Deviations from the behavior predicted by the optical model and standard coupled-channels calculations have been observed in this system. The fusion cross sections can be reproduced by a shallow potential model well, which was originally developed to explain the hindrance of heavy-ion fusion for systems with negative Q-values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Precision Relative Position Sensing System for Formation Flying Spacecraft

Three candidate sensors under development - Longitudinal Sensing: Precision Laser Ranger (PLR) - Periodic laser pulses are reflected off a distant target. - Heterodyne analysis of returning pulses enables high resolution ranging. - Transverse Sensing = Transverse Alignment Sensor (TAS) - Laser beam is focused onto distant laser position sensor. - Analog sensor provides coordinates of spot on sensor. - 3D PLR: Alternative approach to transverse sensing: - Combine PLR with 3D target covered with retroreflective material. - 6 degree of freedom sensing using PLR. - May eliminate need for TAS.

Anne-Marie Novo-Gradac↗

Creating a Software Framework for Simulating Satellite Geolocation

It is hard to imagine life these days without having some sort of electronic indication of one's current location. Whether the purpose is for business, personal, or emergency use, utilizing smart cell phones, in-vehicle navigation systems, or location beacons, dependence on the Global Positioning System (GPS) is pervasive. Yet the availability of the GPS should not be taken for granted. Both environmental (e.g., terrain, weather) and intentional interference (i.e., jamming) can reduce or deny satellite access. In order to investigate these and other issues, as well as to explore possible alternative satellite constellations, an application called the Satellite Simulation Toolkit (SatSim) was created. This paper presents a high-level overview of SatSim and an example of how it may be used to study geolocation.

97 MATHEMATICS AND COMPUTING↗