Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Isotopologue Consistency of Semi-Empirically Computed InfraRed Line Lists and Further Improvement for Rare Isotopologues: CO2 and SO2 Case Studies.

The semi-empirical molecular rovibrational IR line lists, such as ExoMol, TheoReTs, and Ames, combine the experimental accuracy and theoretical power to reach better than 0.1 cm-1 accuracy for line positions and better than 80-90% agreement for line intensities. The quality of these existing semi-empirical IR lists allows further improvements of intensity and line positions for those unobserved minor isotopologues. This paper presents our new BTRHE (Best Theory + Reliable High-resolution Experiment) strategy implementation. For line intensity, the isotopologue consistency and the patterns of mass dependence in the Ames-296K SO2 and CO2 IR lists are quantitatively presented along the mass-inverse coordinates. The consistency and patterns are better than those in existing experimental data. The methodology proposed here can be used to identify inconsistencies, outliers, and mistakes in intensities, and help improve Effective Dipole Model (EDM) and molecular IR databases. We call for an experimental study on the 50006 and 60007 bands of CO2 628. For line position predictions, a simple approach combining the variational IR line lists with Effective Hamiltonian (EH) model may refine the effective rotational constants A0/B0/C0 and quartic centrifugal distortion constants of minor isotopologues. The prediction accuracy may be improved by two orders of magnitude, i.e. reaching 0-5 MHz prediction accuracy in the range of J<20-30, Ka<10-20, and 0.01-0.02 MHz accuracy for A0/B0/C0. Several important factors have been systematically investigated and discussed, e.g. convergence, uncertainties, higher order terms, fixing EH parameters, mass coordinates, etc. Amicrowave (MW) line set consisting of 644,636 strong transitions for all 30 isotopologues and corresponding refined EH(Ames) parameters are reported in the supplementary material. This approach may be easily extended to rovibrational bands, hot bands, and other molecular systems.

Xinchuan Huang↗

Correlation of Kp with the substorm-injected plasma boundary

The local time position of the low-energy substorm-injected plasma boundary in the dusk to midnight region of the magnetosphere as observed by the geostationary satellite ATS 5 is found to be correlated with the interpolated Kp index. Considering the time resolution of Kp, the correlation is found to be quite close but dependent on season. An estimate of the overall shape and position of the low-energy boundary within this region of the magnetosphere as a function of Kp is found by using a fit to the authors' winter data correlation in conjunction with a fit of data presented by Carpenter (1967) concerning the Kp-related radial positioning of the plasmapause boundary in the postmidnight region. This analysis results in a spiral structure, the scale of which depends on Kp.

Mauk, B. H.↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

T-Slide Linear Actuators

T-slide linear actuators use gear bearing differential epicyclical transmissions (GBDETs) to directly drive a linear rack, which, in turn, performs the actuation. Conventional systems use a rotary power source in conjunction with a nut and screw to provide linear motion. Non-back-drive properties of GBDETs make the new actuator more direct and simpler. Versions of this approach will serve as a long-stroke, ultra-precision, position actuator for NASA science instruments, and as a rugged, linear actuator for NASA deployment duties. The T slide can operate effectively in the presence of side forces and torques. Versions of the actuator can perform ultra-precision positioning. A basic T-slide actuator is a long-stroke, rack-and-pinion linear actuator that, typically, consists of a T-slide, several idlers, a transmission to drive the slide (powered by an electric motor) and a housing that holds the entire assembly. The actuator is driven by gear action on its top surface, and is guided and constrained by gear-bearing idlers on its other two parallel surfaces. The geometry, implemented with gear-bearing technology, is particularly effective. An electronic motor operating through a GBDET can directly drive the T slide against large loads, as a rack and pinion linear actuator, with no break and no danger of back driving. The actuator drives the slide into position and stops. The slide holes position with power off and no brake, regardless of load. With the T slide configuration, this GBDET has an entire T-gear surface on which to operate. The GB idlers coupling the other two T slide parallel surfaces to their housing counterpart surfaces provide constraints in five degrees-of-freedom and rolling friction in the direction of actuation. Multiple GB idlers provide roller bearing strength sufficient to support efficient, rolling friction movement, even in the presence of large, resisting forces. T-slide actuators can be controlled using the combination of an off-the-shelf, electric servomotor, a motor angle resolution sensor (typically an encoder or resolver), and microprocessor-based intelligent software. In applications requiring precision positioning, it may be necessary to add strain gauges to the T-slide housing. Existing sensory- interactive motion control art will work for T slides. For open-loop positioning, a stepping motor emulation technique can be used.

Vranish, John↗

The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

The balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approximately 20 keV to greater than approximately 10 MeV. GRIPS will address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution of less than 0.1 cubic millimeter. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-centimeter thick tungsten alloy slit/slat grid with pitches that range quasi-continuously from 1 to 13 millimeters. The MPRM is situated 8 meters from the spectrometer to provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e., as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS is scheduled for a continental-US engineering test flight in fall 2013, followed by long or ultra-long duration balloon flights in Antarctica.

Shih, Albert Y.↗

Geometrical analysis of Cys-Cys bridges in proteins and their prediction from incomplete structural information

Analysis of C-alpha atom positions from cysteines involved in disulphide bridges in protein crystals shows that their geometric characteristics are unique with respect to other Cys-Cys, non-bridging pairs. They may be used for predicting disulphide connections in incompletely determined protein structures, such as low resolution crystallography or theoretical folding experiments. The basic unit for analysis and prediction is the 3 x 3 distance matrix for Cx positions of residues (i - 1), Cys(i), (i +1) with (j - 1), Cys(j), (j + 1). In each of its columns, row and diagonal vector--outer distances are larger than the central distance. This analysis is compared with some analytical models.

NASA Discipline Exobiology↗

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra↗

DMSP-SSM/1 NASA algorithm validation using primarily LANDSAT and secondarily DMSP and/or AVHRR visible and thermal infrared satellite imagery

The approach to the DMSP SSMI (Defense Meteorological Satellite Program; Special Sensor Microwave Imager) sea-ice validation effort is to demonstrate a quantitative relationship between the SSMI-derived sea ice parameters and those same parameters derived from other data sets including visible and infrared satellite imagery, aerial photographic and high-resolution microwave aircraft imagery. The question to be addressed is to what accuracy (relative to these other observations) can the following ice parameters be determined: (1) position of the ice boundary; (2) total sea ice concentration; and (3) multiyear sea ice concentration. Specific tasks include: (1) a study of the interrelationship of surface information content and sensor spatial and spectral resolution in order to establish relationships between ice surface features and the manner in which they are expressed in the satellite observations; and (2) apply these relationships to map the sea ice features which can be used to evaluate NASA's proposed SSM/1 sea ice algorithms. Other key points to be addressed include the accuracy to which these parameters can be determined in different regions (marginal ice zone such as Bering Sea, Arctic ocean, such as Beaufort Sea); the accuracy of these parameters for different seasons; the accuracy of the algorithms weather filter under different weather conditions; and the effectiveness of the 85.5 GHz channels to locate the ice edge.

Steffen, K.↗

Infrared atlas charts of the eclipsed moon.

The objective of this atlas is to present the thermal response of the lunar surface observed during an eclipse of the moon with accurate position data. The observations were made at a wavelength of 11 microns with an angular resolution of 10 sec, equivalent to 17 km at the disk center. Over a thousand thermally anomalous regions (hot spots) were detected. They cool more slowly than their environs and remain warmer than their environs during the umbral phase. In addition to these very localized hot spots, some of the maria show thermal enhancements during the eclipse. Fourty four charts make up this atlas which are identical in coverage and projection to the Lunar Atlas Charts (LAC) series. The charts are in the form of digital images of a normalized temperature difference which is particularly useful for studying regions of small thermal enhancements. Each increase of intensity corresponds to a 4 K temperature increase.

Shorthill, R. W.↗

High resolution spectral measurement of the HNO3 11.3-micron band using tunable diode lasers

High resolution spectra in the region of the 2-nu9 band of nitric acid have been obtained for selected portions of the HNO3 spectrum using tunable diode laser techniques. Continuous spectra are presented from 891.25/cm to 898.77/cm, with a spectral resolution less than or equal to 0.001/cm (30 MHz). Absolute line intensities and line positions are presented. Absolute wavelength calibration was obtained by frequency mixing the diode laser with a C(13)O2(16) isotope laser. Self and foreign gas (N2) broadening coefficients were iteratively calculated from the experimental data and were determined.

Brockman, P.↗

X-ray studies of quasars with the Einstein Observatory

Results of an investigation of the X-ray properties of quasars conducted using the Einstein Observatory (HEAO 2) are reported. The positions, fluxes and luminosities of 35 known quasars were observed by the Einstein high-resolution imaging detector and the imaging proportional counter. Assuming optical redshifts as valid distance indicators, 0.5-4.5 keV X-ray luminosities ranging from 10 to the 43rd to 10 to the 47 ergs/sec are obtained, with evidence of very little cold gas absorption. Flux variability on a time scale of less than 10,000 sec is observed for the quasar OX 169, which implies a mass between 8 x 10 to the 5th and 2 x 10 to the 8th solar masses for the black hole assumed to be responsible for the emission. Preliminary results of the quasar survey also indicate that quasars contribute significantly to the diffuse X-ray background.

Tananbaum, H.↗

Specification of a NAVSTAR Global Positioning System (GPS) receiver for a differential GPS ground system

One step towards the successful completion of a functional ground unit for the Differential Global Positioning System (DGPS) will be in choosing a currently available GPS receiver that will accurately measure the propagation times of the satellite signals and have the capability to be electrically interfaced with and controlled by a Digital Equipment Corporation (DEC) PDP-11/34A computer. The minimum requirements and characteristics of a NAVSTAR Global Positioning System (GPS) receiver are described. The specific technical specifications addressed include data accuracies and resolutions, receiver interface/external control, enclosure dimensions and mounting requirements, receiver operation, and environmental specifications.

Mccall, D. L.↗

White-light movies of the solar photosphere from the SOUP instrument on Spacelab

Initial results are presented on solar granulation, pores and sunspots from the white-light films obtained by the Solar Optical Universal Polarimeter (SOUP) instrument in Spacelab 2. Several hours of movies were taken at various disk and limb positions in quiet and active regions. The images are diffraction-limited at 0.5 arcsec resolution and are, of course, free of atmospheric seeing and distortion. Properties of the granulation in magnetic and nonmagnetic regions are compared and are found to differ significantly in size, rate of intensity variation, and lifetime. In quiet sun, on the order of fifty-percent of the area has at least one 'exploding granule' occurring in it during a 25-min period. Local correlation tracking has detected several types of transverse flows, including systematic outflow from the penumbral boundary of a spot, motion of penumbral filaments, and cellular flow patterns of supergranular and mesogranular size. Feature tracking has shown that, in the quiet sun, the average granule fragment has a velocity of about one kilometer/second.

Title, A. M.↗

Recycling isotachophoresis - A novel approach to preparative protein fractionation

The concept of automated recycling isotachophoresis (RITP) as a purification methodology is discussed, in addition to a description of the apparatus. In the present automated RITP, the computer system follows the achievement of steady state using arrays of universal and specific sensors, monitors the position of the front edge of the zone structure, activates the counterflow if the leading boundary passes a specified position along the separation axis, or changes the applied current, accordingly. The system demonstrates high resolution, in addition to higher processing rates than are possible in zone electrophoresis or isoelectric focusing.

Sloan, Jeffrey E.↗

H2 and H I emission line imaging of the ring nebula (NGC 6720)

Infrared emission-line images of the v = 1-0 S(1) transition of molecular hydrogen and Br-gamma recombination line of atomic hydrogen which cover the entire extent of NGC 6720, the Ring nebula. The maps presented here are the highest angular resolution images of these transitions yet produced for this object and have very low relative positional uncertainty. As a result, the spatial stratification of the ionized and shocked molecular zones within the nebula is clearly resolved. These data, and data from the Infrared Astronomical Satellite, are used to determine the H2, H I, and dust mass within the nebula. Energy sources for the dust heating, formation and destruction of the H2, and overall evolution of the nebula are also discussed.

Greenhouse, Matthew A.↗

Aerosols and polar stratospheric clouds measurements during the EASOE campaign

Preliminary results of observations performed using two different lidar systems during the EASOE (European Arctic Stratospheric Ozone Experiment), which has taken place in the winter of 1991-1992 in the northern hemisphere lattitude regions, are presented. The first system is a ground based multiwavelength lidar intended to perform measurements of the ozone vertical distribution in the 5 km to 40 km altitude range. It was located in Sodankyla (67 degrees N, 27 degrees E) as part of the ELSA experiment. The objectives of the ELSA cooperative project is to study the relation between polar stratospheric cloud events and ozone depletion with high vertical resolution and temporal continuity, and the evolution of the ozone distribution in relation to the position of the polar vortex. The second system is an airborne backscatter lidar (Leandre) which allows for the study of the 3-D structure and the optical properties of polar stratospheric clouds. The Leandre instrument is a dual-polarization lidar system, emitting at 532 nm, which allows for the determination of the type of clouds observed, according to the usual classification of polar stratospheric clouds. More than 60 hours of flight were performed in Dec. 1991, and Jan. and Feb. 1992 in Kiruna, Sweden. The operation of the Leandre instrument has led to the observation of the short scale variability of the Pinatubo volcanic cloud in the high latitude regions and to several episodes of polar stratospheric clouds. Preliminary analysis of the data is presented.

Haner, D.↗

Development of a calibration workstation for SIR-C

The paper describes the status of a comprehensive synthetic aperture radar (SAR) software package developed specifically to aid the calibration of a multifrequency and multipolarization radar like the Shuttle Imaging Radar, SIR-C. The primary data types processed are engineering telemetry, point targets (corner reflectors and polarimetric active radar calibrators), distributed targets (clutter), tone-generators, and ground receivers. The parameters derived to aid the calibration of the production processor include measurements of relative radiometric channel to channel imbalance, absolute calibration constants, antenna pattern corrections, noise levels, polarimetric cross-talk, and geometric offsets. The software reports standard performance measurements such as resolution, peak and integrated sidelobes, radiometric response accuracy, and geometrical distortions such as scale errors, position bias and standard deviation, and image skew. Furthermore, the inclusion of software to allow updates of the shuttle-state vector (position and velocity) is considered.

Madsen, S. N.↗

Airborne gravimetry, altimetry, and GPS navigation errors

Proper interpretation of airborne gravimetry and altimetry requires good knowledge of aircraft trajectory. Recent advances in precise navigation with differential GPS have made it possible to measure gravity from the air with accuracies of a few milligals, and to obtain altimeter profiles of terrain or sea surface correct to one decimeter. These developments are opening otherwise inaccessible regions to detailed geophysical mapping. Navigation with GPS presents some problems that grow worse with increasing distance from a fixed receiver: the effect of errors in tropospheric refraction correction, GPS ephemerides, and the coordinates of the fixed receivers. Ionospheric refraction and orbit error complicate ambiguity resolution. Optimal navigation should treat all error sources as unknowns, together with the instantaneous vehicle position. To do so, fast and reliable numerical techniques are needed: efficient and stable Kalman filter-smoother algorithms, together with data compression and, sometimes, the use of simplified dynamics.

Colombo, Oscar L.↗