Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Advancing the Deployment of Utility-Scale Photovoltaic Plants in the Northeast

As one of the premier research laboratories operated by the Department of Energy, Brookhaven National Laboratory (BNL) is pursuing an energy research agenda that focuses on renewable energy systems and will help to secure the nation's energy security. A key element of the BNL research is the advancement of grid-connected utility-scale solar photovoltaic (PV) plants, particularly in the northeastern part of the country where BNL is located. While a great deal of information has been generated regarding solar PV systems located in mostly sunny, hot, arid climates of the southwest US, very little data is available to characterize the performance of these systems in the cool, humid, frequently overcast climates experienced in the northeastern portion of the country. Recognizing that there is both a need and a market for solar PV generation in the northeast, BNL is pursuing research that will advance the deployment of this important renewable energy resource. BNL's research will leverage access to unique time-resolved data sets from the 37MWp solar array recently developed on its campus. In addition, BNL is developing a separate 1MWp solar research array on its campus that will allow field testing of new PV system technologies, including solar modules and balance of plant equipment, such as inverters, energy storage devices, and control platforms. These research capabilities will form the cornerstone of the new Northeast Solar Energy Research Center (NSERC) being developed at BNL. In this paper, an overview of BNL's energy research agenda is given, along with a description of the 37MWp solar array and the NSERC.

14 SOLAR ENERGY↗

Blind photovoltaic modeling intercomparison: A multidimensional data analysis and lessons learned

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA, and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. The results showed overall median mean bias (i.e., the average error per participant) of 0.6% in annual irradiation and –3.3% in annual energy yield. While most PV performance modeling results seem to exhibit higher precision and accuracy as compared to an earlier blind PV modeling study in 2010, human errors, modeling skills, and derates were found to still cause significant errors in the estimates.

14 SOLAR ENERGY↗

Ransomware Security Threat Modeling for Photovoltaic Systems

Ransomware attacks are one of the most dangerous cyber-attacks which can disrupt the operation of photovoltaic (PV) systems and incur an enormous economic loss. This paper introduces a ransomware security threat modeling method that identifies potential vulnerabilities, threats, and impacts of ransomware attacks targeting a PV system. Here, the security threat modeling consists of three steps: 1) system identification, 2) threat modeling that finds existing vulnerabilities, 3) attack modeling that designs attack profiles to succeed ransomware attacks, and 4) penetration testing that performs authorized cyber-attacks and analyzes impacts of the ransomware attack profiles using a real-time hardware-in-the-loop (HIL) PV system security testbed.

attack modeling↗

Solar Power System Analyses for Electric Propulsion Missions

Solar electric propulsion (SEP) mission architectures are applicable to a wide range of NASA missions including human Mars exploration and robotic exploration of the outer planets. In this paper, we discuss the conceptual design and detailed performance analysis of an SEP stage electric power system (EPS). EPS performance, mass and area predictions are compared for several PV array technologies. Based on these studies, an EPS design for a 1-MW class, Human Mars Mission SEP stage was developed with a reasonable mass, 9.4 metric tons, and feasible deployed array area, 5800 sq m. An EPS was also designed for the Europa Mapper spacecraft and had a mass of 151 kg and a deployed array area of 106 sq m.

Kerslake, Thomas W.↗

New Switches for Utility-Scale Inverters: First In-Class Demonstration of a Completely New Type of SiC Bipolar Switch (15kV-20kV) for Utility-Scale Inverters

Solar ADEPT Project: The SiCLAB is developing a new power switch for utility-scale PV inverters that would improve the performance and significantly reduce the size, weight, and energy loss of PV systems. A power switch controls the electrical energy flowing through an inverter, which takes the electrical current from a PV solar panel and converts it into the type and amount of electricity that is compatible with the electric grid. SiCLAB is using silicon carbide (SiC) semiconductors in its new power switches, which are more efficient than the silicon semiconductors used to conduct electricity in most conventional power switches today. Switches with SiC semiconductors can operate at much higher temperatures, as well as higher voltage and power levels than silicon switches. SiC-based power switches are also smaller than those made with silicon alone, so they result in much smaller and lighter electrical devices. In addition to their use in utility-scale PV inverters, SiCLAB’s new power switches can also be used in wind turbines, railways, and other smart grid applications.

ARPA-E↗

Lanai high-density irradiance sensor network for characterizing solar resource variability of MW-scale PV system.

Sandia National Laboratories (Sandia) and SunPower Corporation (SunPower) have completed design and deployment of an autonomous irradiance monitoring system based on wireless mesh communications and a battery operated data acquisition system. The Lanai High-Density Irradiance Sensor Network is comprised of 24 LI-COR{reg_sign} irradiance sensors (silicon pyranometers) polled by 19 RF Radios. The system was implemented with commercially available hardware and custom developed LabVIEW applications. The network of solar irradiance sensors was installed in January 2010 around the periphery and within the 1.2 MW ac La Ola PV plant on the island of Lanai, Hawaii. Data acquired at 1 second intervals is transmitted over wireless links to be time-stamped and recorded on SunPower data servers at the site for later analysis. The intent is to study power and solar resource data sets to correlate the movement of cloud shadows across the PV array and its effect on power output of the PV plant. The irradiance data sets recorded will be used to study the shape, size and velocity of cloud shadows. This data, along with time-correlated PV array output data, will support the development and validation of a PV performance model that can predict the short-term output characteristics (ramp rates) of PV systems of different sizes and designs. This analysis could also be used by the La Ola system operator to predict power ramp events and support the function of the future battery system. This experience could be used to validate short-term output forecasting methodologies.

14 SOLAR ENERGY↗

Solar Performance Insight (Final Report)

The PV Operations and Maintenance (O&M) service industry lacks an affordable, well-documented, intuitive PV modeling and analytics tool to calculate modeled performance from actual data from multiple data acquisition systems (DAS). We envision a performance modeling and analytics platform built on open-source, extensible, community-maintained code. The key innovation is the community-driven development of pvlib python delivered through a lightweight web service to provide configurable, consistent and reproducible PV modeling for O&M providers.

14 SOLAR ENERGY↗

Simulated potential for enhanced performance of mechanically stacked hybrid III–V/Si tandem photovoltaic modules using DC–DC converters

This work examines a tandem module design with GaInP2 mechanically stacked on top of crystalline Si, using a detailed photovoltaic (PV) system model to simulate four-terminal (4T) unconstrained and two-terminal voltage-matched (2T VM) parallel architectures. Module-level power electronics is proposed for the 2T VM module design to enhance its performance over the breadth of temperatures experienced by a typical PV installation. Annual, hourly simulations of various scenarios indicate that this design can reduce annual energy losses to ~0.5% relative to the 4T module configuration. Consideration is given to both performance and practical design for building or ground mount installations, emphasizing compatibility with existing standard Si modules.

14 SOLAR ENERGY↗

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗

Advanced High-Fidelity Lumped EMT Grid Modelling & Comparison

There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.

Debnath, Suman↗

Photovoltaics on Landfills in Puerto Rico

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Commonwealth of Puerto Rico for a feasibility study of m0treAlables on several brownfield sites. The EPA defines a brownfield as 'a property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant.' All of the brownfields in this study are landfill sites. Citizens of Puerto Rico, city planners, and site managers are interested in redevelopment uses for landfills in Puerto Rico, which are particularly well suited for solar photovoltaic (PV) installation. The purpose of this report is to assess the landfills with the highest potential for possible solar PV installation and estimate cost, performance, and site impacts of three different PV options: crystalline silicon (fixed-tilt), crystalline silicon (single-axis tracking), and thin film (fixed-tilt). Each option represents a standalone system that can be sized to use an entire available site area. In addition, the report outlines financing options that could assist in the implementation of a system. The feasibility of PV systems installed on landfills is highly impacted by the available area for an array, solar resource, operating status, landfill cap status, distance to transmission lines, and distance to major roads. All of the landfills in Puerto Rico were screened according to these criteria in order to determine the sites with the greatest potential. Eight landfills were chosen for site visits based on the screening criteria and location. Because of time constraints and the fact that Puerto Rico is a relatively large island, the eight landfills for this visit were all located in the eastern half of the island. The findings from this report can be applied to landfills in the western half of the island. The economics of a potential PV system on landfills in Puerto Rico depend greatly on the cost of electricity. Currently, PREPA has an average electric rate of $0.119/kWh. Based on past electric rate increases in Puerto Rico and other islands in the Caribbean, this rate could increase to $0.15/kWh or higher in a relatively short amount of time. In the coming years, increasing electrical rates and increased necessity for clean power will continue to improve the feasibility of implementing solar PV systems at these sites.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

Transforming PV installations toward dispatchable, schedulable energy solutions

The Advanced Energy led SEGIS-AC program represents an industry partnership driven collaborative effort to continue to lower the barriers to increasing penetration of PV on the grid while also lowering overall system cost consistent with the Department of Energy SunShot Initiative. The SEGIS-AC program follows the DOE sponsored three year SEGIS program, which had similar high level goals, but with a broader exploratory scope. In SEGIS-AC, the team carries forward a new communications based islanding detection technology developed during the SEGIS program. Advanced utility interactive controls are further developed, and a storage inverter system is developed focused on intermittency mitigation due to cloud induced transients. Communications based island detection coupled with advanced controls and a storage system are shown to improve utility distribution feeder performance and to enable increased solar PV penetration levels. By the conclusion of the program, multiple utilities and customers have expressed awareness and desire to make use of the technologies developed and demonstrated under this program. This factor has led the Advanced Energy led team to deem the program an overall success. The report following details the technologies developed and demonstrated, as well as industry engagement.

14 SOLAR ENERGY↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Accurate Modeling of Converter Interfaced Generation (CIG) on a Practical Bulk Power System

With increased penetration of converter interfaced generation (CIG) in power systems, it becomes imperative to adequately model them in both steady-state and dynamic simulations. There are several modeling approaches and simulation platforms for CIG. In addition, it is noted that suitability of modeling approaches and models is also dependent on the system conditions. However, their suitability has yet to be systematically analyzed, and this becomes a challenge in the industry without a systemic method. To tackle these challenges, in this paper, we first develop a methodology for identifying the maximum penetration of aggregated rooftop sources that can be represented as negative loads in both the steady state and dynamic analysis. Then we verify the suitability of positive-sequence performance-based model and detailed electromagnetic transient (EMT) model for utility-scale PV plants under different fault conditions. Based on the results, we perform dynamic simulations on a large practical system with both positive-sequence transient stability(TS) and EMT-TS hybrid simulation. Our study shows that positive-sequence performance based PV plant model is more suitable for study cases with faults relatively far away from the point of connection, and that positive-sequence models and TS simulation approach can produce comparable results with reference to EMT-TS hybrid simulation for normally-cleared single-line-to-ground faults, but the inadequacy of positive-sequence based model and simulation approach becomes obvious for prolonged-tripping of unbalanced faults in proximity of the PV plants.

Huang, Qiuhua↗

Field Experience with 3-Sun Mirror Module Systems

JX Crystals 3-sun PV mirror modules have now been operating in four separate systems in the field for up to 2 years. Two post-mounted 2-axis tracking arrays of 12 modules each were installed at the Shanghai Flower Park in April of 2006. Then 672 modules were installed in a 100 kW array on N-S horizontal beam trackers at the Shanghai Flower Port in November of 2006. Finally, sets of 4 modules were installed on azimuth-tracking carousels on buildings at the Oak Ridge National Lab and at the U. of Nevada in Las Vegas in late 2007. All of these modules in each of these systems are still operating at their initial power ratings. No degradation in performance has been observed. The benefit of these 3-sun PV mirror modules is that they use 1/3 of the silicon single-crystal cell material in comparison to traditional planar modules. Since aluminum mirrors are much cheaper than high-purity single-crystal silicon-cells, these modules and systems should be much lower in cost when manufactured in high volume.

14 SOLAR ENERGY↗

Spatiotemporal Modeling of Real World Backsheets Field Survey Data: Hierarchical (Multilevel) Generalized Additive Models: Preprint

Assessing photovoltaic module backsheet durability is critical to increasing module lifetime. Lab based accelerating testing has recently failed to predict large scale failures of widely adopted polymeric materials. Field surveyed data is critical to assess the performance of component lifetime. Using a documented field survey protocol, 13 field surveys where conducted. Each measurement is encoded with it's spatial location in respect to the other modules. By combining field survey data on degradation predictors with real time satellite weather data, data-driven predictive models of backsheet degradation were trained. LOESS models were constructed to investigate the spatial dependence of measurements. It was found that micro-climatic effects like treelines, ground surface changes, and elevation changes effected the magnitude and variance of the measurements. A GAM model was created to predict the value of degradation based on measured predictors. The model includes variables on the climate of the system and the location of each measurement in the PV mounting structure. The model performed well with an adj:R2 of 0:95 for yellowness index prediction. The model was cross-validated using k-folds.

backsheet↗