A robust I–V curve correction procedure for degraded photovoltaic modules
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The goal of this work is to create an online tool that can be used to search for degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published open-source allowing users to expand on the existing framework.
This case study investigates mono-crystalline silicon modules from underperforming portions of a utility-scale photovoltaic power plant. Field-collected I-V curves and electroluminescence imaging suggested that increased series resistance was a primary factor driving module degradation. Selected modules were removed from the field for further analysis, including incremental damp heat accelerated testing, which confirmed a progression in series resistance degradation. Two distinct cell degradation behaviors became apparent during the investigation. Cross-sectional scanning electron microscopy (with elemental analysis) and scanning spreading resistance microscopy identified key differences between the two degradation mechanisms, primarily grid finger width and contact resistance. Additionally, the study highlights the reliability implications of retest requirements in International Electrotechnical Commission 61215 for material changes and how they may have mitigated the degradation observed at this site.
As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? We compile results from ca. 320 perovskite PV cells and modules, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, and show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. We discuss implications of these findings on performance testing protocols and propose possible options for fast and accurate testing of perovskite PV.
The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1k VA experimental setup that interfaces a PV module to the grid.
The objectives of this project are as follows: • The population behavior of fielded modules in various conditions of use • Predictions of materials in specific climatic zones • Understanding of a module’s local environment in the field on its degradation It aims to understand how and what backsheet materials of photovoltaic modules degrade in the real world field. • Field Survey Protocol This project is started from the protocol, because all the data, information, domain knowledge are from experience of the real world field surveys, which is based on the protocol. The Protocol is explored from the experience of the field survey observations. With the increasing of the field surveys, it is refined for three versions, which are Task 1.0 (Section 3.1), Task 6.0 (Section 3.6), Task 10.0 (Section 3.10) respectively. It includes a document and a training video, which is able to direct other teams to follow the same procedure with the sites surveyed during this project. The documents include the detailed information but is not limited to the terminology definition, instruments SOP, preparation items for the surveys, form for the data collections, the order of the information collection. The final version of the protocol can be found at Appendix A, see Section 5. Additional, It can also be found at Open Science Framework (OSF), see Section 3.18 for detail. • Written Waiver Request Before staring the field surveys, the request of the waiver for international surveys is completed, because the limitation of climate zone in the United States, see Appendix B in Section 6 for the request documents. Unfortunately, only 1 international site from Taiwan, China can be finished, due to the COVID-19. • Field Survey According to the protocol we built in Section 3.1, 3.6 and 3.10, 41 sites have been surveyed across seven different climate zones (Cfa, Csa, Csb, BSk, Dfa, Dfb, Am). A variety of materials, including Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), Polyvinyl Fluoride (PVF), Polyvinylidene Fluoride (PVDF), Acrylic PVDF, Fluoroethylene Vinyl Ether (FEVE), and Glass, were identified. These sites are located in various states including California, South Carolina, New Mexico, Maryland, Ohio, Tennessee, Florida, Massachusetts, Illinois, Minnesota, Oregon, Colorado, and Taiwan, Republic of China. The ages of the sites ranged from 2 - 38 years in service and the field size varied from 1 MW - 25 MW. All requirements for the modeling have been satisfied. Some observations like ’Edge Effect’ for the rows and Junction box heating will also be a useful knowledge to build the model. Section 3.7 provides detailed information on the sites visited during this reporting period.
Abstract not provided.
The Space Station Freedom electric power system (EPS) will initially rely on photovoltaics for power generation and Ni/H2 batteries for electrical energy storage. The current design for and the development status of two major subsystems in the PV Power Module is discussed. The energy storage subsystem comprised of high capacity Ni/H2 batteries and the single-phase thermal control system that rejects the excess heat generated by the batteries and other components associated with power generation and storage is described.
The Space Station Freedom electric power system (EPS) will initially rely on photovoltaics for power generation and Ni/H2 batteries for electrical energy storage. The current design for the development status of two major subsystems in the PV Power Module is discussed. The energy storage subsystem comprised of high capacity Ni/H2 batteries and the single-phase thermal control system that rejects the excess heat generated by the batteries and other components associated with power generation andstorage is described.
The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.
Following the path of space PV collector development in its early stages, terrestrial PV technologies based upon single-crystal silicon have matured rapidly. Currently, terrestrial PV cells with efficiencies approaching space cell efficiencies are being fabricated into modules at a fraction of the space PV module cost. New materials, including CuInSe2 and amorphous silicon, are being developed for lowering the cost, and multijunction materials for achieving higher efficiency. Large grid-interactive, tracking flat-plate power systems and concentrator PV systems totaling about 10 MW, are already in operation. Collector technology development both flat-plate and concentrator, will continue under an extensive government and private industry partnership.
The operating efficiency of photovoltaic (PV) plants can be improved if damaged or degraded modules can be detected and identified. Currently, string-level power electronics can detect problems with modules or cabling but not locate them, which would facilitate addressing these issues. Here, we investigate the ability of spread spectrum time domain reflectometry (SSTDR) to both detect and locate/identify damaged cells and modules within a series-connected PV string. We tested the ability of SSTDR to detect and locate single-cell mini-modules and full-sized PV modules, which were intentionally damaged by impacts with a hammer (breaking the glass and damaging the silicon below) or by cutting through some or all busbars. Damage to the glass and silicon of cells was detected and located within a small string of minimodules. Busbar damage was detectable only if an open was created by cutting through all intercell busbars. Furthermore, physical impact damage to the glass and silicon of a full-sized PV module could be detected, but further development of signal processing is needed to achieve localization of such damaged modules within a string.
Herein, electroluminescence (EL) and thermal imaging are used to examine p–i–n metal halide perovskite (MHP) photovoltaic (PV) mini-modules (MA0.6FA0.4PbI3, 20 cells, 78 cm2) before and after indoor-accelerated stress testing or outdoor deployment. Distinct spatial patterns in the EL images emerge, which depend on the external stress conditions experienced by the mini-module. Imaging results highlight a distribution of dark speckle features that dominate after UV stress, attributed to widespread interfacial contact degradation. Lateral intensity gradients across cells dominate after thermal cycling (TC) stress, attributed to current crowding near scribe defects. While current–voltage analysis alone does not give full insight on the degradation process, this study shows that distinct degradation modes can be further defined by multimodal electro-optical imaging (i.e., EL combined with photoluminescence and dark lock-in thermography). Neither UV exposure nor TC-accelerated stress testing alone replicates the same degradation signatures observed after outdoor deployment, suggesting that multiple degradation modes occur under concurrent stressors outdoors. Finally, spatial characterization of degradation modes in MHP PV mini-modules before and after accelerated stress testing lays the groundwork for developing targeted accelerated stress testing procedures through comparison with outdoor aging.
Objectives were listed for four areas: engineering science, reliability physics, module development, and module performance and failure analysis. The engineering science efforts are to develop module design requirements for large-scale photovoltaic (PV) applications and to develop generic module and array design and construction technology to meet the needed performance, safety, reliability, and system interfaces. The reliability physics effort is to develop the technology for 30-year life modules. The module development efforts are to transfer new technology to PV manufacturers and their products, and to evaluate these advanced modules. The module performance and failure analysis efforts are to determine PV module performance, to identify needed development, and to assess suitability for large-scale use.
bifacialvf is a self-contained view factor (or configuration factor) model which replicates a 5-row PV system of infinite extent perpendicular to the module rows. Single-axis tracking is supported, and hourly output files based on TMY inputs are saved. Spatial nonuniformity is reported, with multiple rear-facing irradiances collected on the back of each module row. Bilinear interpolation code add-on to bifacialvf (description below) to pre-generate IV arrays and bifacial coefficients, and to examine the energy production with back side irradiance mismatch for either a portrait or landscape module. Included are IV curves and bifacial info for a Yingli (standard) module. Based on the publication: "A Practical Irradiance Model for Bifacial PV Modules" B. Marion, S. MacAlpine, C. Deline, A. Asgharzadeh, F. Toor, D. Riley, J. Stein, C. Hansen 2017 IEEE Photovoltaic Specialists Conference, Washington DC, 2017 URL: https://www.nrel.gov/docs/fy17osti/67847.pdf
To achieve useful, fair, and cost-effective design qualification and type approval testing for PV inverters, two procedures were developed and demonstrated to evaluate the bus link capacitors and power transistor—and where applicable, its module—for long-term reliability. We evaluate the inverter under simulated use conditions with heat run tests to find the highest operating temperatures reached by these components. The procedures are demonstrated in this study with a 4-kVA class string inverter. The maximum temperature of the DC bus link capacitors was determined to be 76.4°C when the ambient temperature was at the inverter's maximum rated temperature of 60°C with derating occurring. On the other hand, the power transistor module's maximum temperature using the heat sink temperature as the index, 92.6°C, occurred in an ambient of 40.8°C when derating was not occurring. The conditions found for upper temperatures exhibited by these components are, respectively, proposed for implementation in the dry heat and thermal cycling tests in the IEC 62093 “Power conversion equipment for photovoltaic systems – Design qualification testing” international standard draft so that the levels applied in the tests are in proportion to those experienced in the field. Finally as a result, fairer evaluation of inverter reliability is realized.
The photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 to 50 years. research efforts aim to achieve this while keeping performance degradation at a minimum for decades. This puts considerable pressure on improving the accuracy of long-term durability and reliability assessments. There is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. The tool will simplify many of the routine computational operations that are common to many degradation studies. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. This repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors.
The Atmospheric Infrared Sounder (AIRS) is a key facility instrument in the NASA Earth Observing System (EOS) program, being implemented to obtain comprehensive long-term measurements of earth processes affecting global change. The instrument performs passive IR remote sensing using a high resolution grating spectrometer with a wide spectral coverage (3.7 - 15.4 m) directing radiation onto a hybrid HgCdTe IRFPA operating at 58K in a vacuum package cooled to 155K. The hybrid HgCdTe FPA consists of twelve modules, 10 with multiplexed photovoltaic detectors and two with individually leaded out photoconductive detectors. The complex FPA has a large optical footprint, 53 mm x 66 mm, and receives energy dispersed from the grating through a precision filter assembly containing 17 narrow band filters. The backside illuminated PV detector arrays are fabricated from P-on-n double layer LPE grown heterojunction detectors in a bilinear format of 50 m x 100 m detectors, with from 232 to 420 detectors per module. For the MWIR bands four PV modules cover the 3.7 m to 8.22 m region. Low detector capacitance and low noise preamplifiers in the ROIC are key to achieving high sensitivities in these bands. Uniform quantum efficiencies and detectivities exceeding 3E13 cm-rtHz/W have been achieved. The LWIR region is covered by six PV modules spanning 8.8 m to 13.75 m. High detector resistance and very low ROIC preamplifier input noise are key to achieving high sensitivity. A detectivity exceeding 2E11 cm-rtHz/W has been achieved at the longest wavelength. Two additional PC modules cover the longest spectral bands out to 15.4 m. This high performance multispectral focal plane has been built and integrated with the dewar assembly, and is currently being integrated with the complete AIRS sensor.