Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Power Management and Distribution (PMAD) Model Development: Final Report

Power management and distribution (PMAD) models were developed in the early 1990's to model candidate architectures for various Space Exploration Initiative (SEI) missions. They were used to generate "ballpark" component mass estimates to support conceptual PMAD system design studies. The initial set of models was provided to NASA Lewis Research Center (since renamed Glenn Research Center) in 1992. They were developed to estimate the characteristics of power conditioning components predicted to be available in the 2005 timeframe. Early 90's component and device designs and material technologies were projected forward to the 2005 timeframe, and algorithms reflecting those design and material improvements were incorporated into the models to generate mass, volume, and efficiency estimates for circa 2005 components. The models are about ten years old now and NASA GRC requested a review of them to determine if they should be updated to bring them into agreement with current performance projections or to incorporate unforeseen design or technology advances. This report documents the results of this review and the updated power conditioning models and new transmission line models generated to estimate post 2005 PMAD system masses and sizes. This effort continues the expansion and enhancement of a library of PMAD models developed to allow system designers to assess future power system architectures and distribution techniques quickly and consistently.

Metcalf, Kenneth J.↗

A design for an intelligent monitor and controller for space station electrical power using parallel distributed problem solving

The emphasis is on defining a set of communicating processes for intelligent spacecraft secondary power distribution and control. The computer hardware and software implementation platform for this work is that of the ADEPTS project at the Johnson Space Center (JSC). The electrical power system design which was used as the basis for this research is that of Space Station Freedom, although the functionality of the processes defined here generalize to any permanent manned space power control application. First, the Space Station Electrical Power Subsystem (EPS) hardware to be monitored is described, followed by a set of scenarios describing typical monitor and control activity. Then, the parallel distributed problem solving approach to knowledge engineering is introduced. There follows a two-step presentation of the intelligent software design for secondary power control. The first step decomposes the problem of monitoring and control into three primary functions. Each of the primary functions is described in detail. Suggestions for refinements and embelishments in design specifications are given.

Morris, Robert A.↗

Advanced Semi-Supervised Learning with Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Semi-Supervised Learning With Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extreme Efficiency 240 Vac to Load Data Center Power Delivery Topologies and Control

The research explored innovative new circuit topologies and power converter architectures for data center power delivery, from the 240 V ac voltage at the input of a server rack, down to the less than 1 V dc power supply of the latest microprocessors. The research pursued three parallel tracks to increase the power conversion efficiency and to reduce the overall size of the servers: 1) An innovative new ac-dc power converter topology which enables improved efficiency through use of a novel direct step-down topology, well suited for the popular 48V dc power distribution. 2) A new series-stacked power delivery approach for servers comprising a large number of similar loads, such as hard drives in storage servers. The approach greatly reduces the power conversion losses, and achieves efficiency well over 99%. 3) A new family of hybrid switched-capacitor power converters that enable improved efficiency and reduced size through the use of dense ceramic capacitors and new circuit topologies that leverage GaN and low-voltage Si transistor technology. Together, the accomplished research achieved the goal of reducing the power conversion losses in datacenters, thereby reducing greenhouse gas emissions, operating costs, and overall electricity consumption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

A matheuristic for design and dispatch of a utility-connected distributed energy system

Modeling distributed power generation systems often requires complicated mathematical expressions that present challenges for commercial optimization solvers. Here, this paper presents a matheuristic to solve a mixed-integer optimization model that informs decisions regarding the design and dispatch of a utility-connected microgrid. We deploy a genetic algorithm to search the system design space and a linear program to solve the economic dispatch problem. The model is a component of a web tool that requires solutions within a few minutes. Our method yields objective function values within 5% of an exogenously produced optimal in fewer than 30 seconds for 90% of our test cases compared to only 10% of our test cases by a traditional optimization solver in the same amount of time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local and utility-wide cost allocations for a more equitable wildfire-resilient distribution grid

Climate-induced extreme weather conditions make electricity infrastructure more vulnerable. They increase the risk of power-line-ignited wildfires which can, in turn, jeopardize electric power delivery. Here, leveraging machine learning, we show that lower-income communities in California not only have lower fractions of power distribution lines undergrounded, but overhead lines and poles in their neighbourhoods are also more vulnerable to wildfires. Should they bear the cost of undergrounding fire-prone lines themselves, they would have to pay a disproportionately higher cost per household. We propose a cost allocation scheme with an income threshold below which the cost is borne by utility-wide ratepayers and above which the cost is borne locally. This scheme can not only minimize the average of undergrounding costs per household as a share of income, but also homogenize such cost–income ratios across communities. Furthermore, our research demonstrates the opportunity to appropriately integrate existing policies to make electricity infrastructure affordable, equitable and reliable amidst climate change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Technical Diversity Benefits of Wind as a Distributed Energy Resource

Distributed energy resources are increasingly used in power distribution systems and microgrids to supply cost competitive power, improve resilience, and provide a host of grid services. Diversifying variable renewable resources (e.g., by combining wind with solar) can increase energy usage efficiency and improve system resilience. However, when grid optimization and resilience studies consider multiple renewable resources, diversity benefits are usually captured only implicitly in the results of location-specific economic optimization. In this paper, metrics are introduced to express the technical value of resource diversity independent of jurisdiction-specific market structures. Specifically, marginal energy usage efficiency metrics are developed to quantify the ability of new distributed generation to produce useful energy and an incremental sustainable ride through metric is developed to express improvement in grid outage ride through capability. While there are economic implications for each of these metrics, the metrics themselves are technically-driven and could be used as components of a technical figure of merit that could be used to inform policy actions, such as development of resource-specific incentives and time-of-use tariff designs. Each of these metrics is demonstrated using balance-of-energy simulations that highlight the benefits of improving resource diversity.

Reiman, Andrew P.↗

Sodium Ion Expansion Power Block for Distributed CSP

The Sodium Ion Expansion Power Block for Distributed CSP was a three-plus-one-year effort under the Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities (CSP: APOLLO) funding program within the U.S. Department of Energy Solar Energy Technologies Office. The primary objective of this project is to develop a dual-stage modular sodium thermal electrochemical converter (Na-TEC) heat engine power block, which can be potentially integrated with either a small-scale dish solar or large-scale heliostats and parabolic trough CSP. Na-TEC is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K –1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. In light of this, we first designed and developed a thermo-electrochemical model, and thermodynamically demonstrated how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also established an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Moreover, a thermal design of an axisymmetric dual-stage Na-TEC is developed to guide the scale-up and fabrication of sub-components of prototype module. A reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model that was developed to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved. Ultimately, we were able to demonstrate thermal efficiency improvements of the Na-TEC heat engine from 19% up to 40.3%, in a dual-stage (non-optimized) prototype module that we designed, fabricated, and tested with high temperature stage at 923 K. Furthermore, a cost-performance analysis for this improved dual-stage design was carried out for distributed-CSP systems. A high-level techno-economic analysis (TEA) explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per We are feasible, which equate to LCOEs from 6.9 to 17.2 cents/kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Solar power satellite system definition study, volume 4, phase 2

Results of an overall evaluation of the solar power satellite concept are reported. Specific topics covered include: solid state sandwich configuration; parametric development of reliability design; power distribution system for solid state solar power satellites; multibeam transmission; GEO base system configuration; suppression of the heavy lift launch vehicle trajectory; conceptual design of an offshore space center facility; solar power satellite development and operations scenario; and microwave power transmission technology, advancement, development, and facility requirements.

Source record↗

Merits of flywheels for spacecraft energy storage

Flywheel energy storage systems which have a very good potential for use in spacecraft are discussed. This system can be superior to alkaline secondary batteries and regenerable fuel cells in most of the areas that are important in spacecraft applications. Of special importance, relative to batteries, are lighter weight, longer cycle and operating life, and high efficiency which minimizes solar array size and the amount of orbital makeup fuel required. Flywheel systems have a long shelf life, give a precise state of charge indication, have modest thermal control needs, are capable of multiple discharges per orbit, have simple ground handling needs, and have characteristics which would be useful for military applications. The major disadvantages of flywheel energy storage systems are that: power is not available during the launch phase without special provisions; and in flight failure of units may force shutdown of good counter rotating units, amplifying the effects of failure and limiting power distribution system options; no inherent emergency power capability unless specifically designed for, and a high level of complexity compared with batteries. The potential advantages of the flywheel energy storage system far outweigh the disadvantages.

Gross, S.↗

Independent Orbiter Assessment (IOA): Analysis of the orbital maneuvering system

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbital Maneuvering System (OMS) hardware are documented. The OMS provides the thrust to perform orbit insertion, orbit circularization, orbit transfer, rendezvous, and deorbit. The OMS is housed in two independent pods located one on each side of the tail and consists of the following subsystems: Helium Pressurization; Propellant Storage and Distribution; Orbital Maneuvering Engine; and Electrical Power Distribution and Control. The IOA analysis process utilized available OMS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluted and analyzed for possible failure modes and effects. Criticality was asigned based upon the severity of the effect for each failure mode.

Prust, C. D.↗

Independent Orbiter Assessment (IOA): Analysis of the reaction control system, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Reaction Control System (RCS). The purpose of the RCS is to provide thrust in and about the X, Y, Z axes for External Tank (ET) separation; orbit insertion maneuvers; orbit translation maneuvers; on-orbit attitude control; rendezvous; proximity operations (payload deploy and capture); deorbit maneuvers; and abort attitude control. The RCS is situated in three independent modules, one forward in the orbiter nose and one in each OMS/RCS pod. Each RCS module consists of the following subsystems: Helium Pressurization Subsystem; Propellant Storage and Distribution Subsystem; Thruster Subsystem; and Electrical Power Distribution and Control Subsystem. Of the failure modes analyzed, 307 could potentially result in a loss of life and/or loss of vehicle.

Burkemper, V. J.↗

Independent Orbiter Assessment (IOA): Analysis of the reaction control system, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Reaction Control System (RCS). The RCS is situated in three independent modules, one forward in the orbiter nose and one in each OMS/RCS pod. Each RCS module consists of the following subsystems: Helium Pressurization Subsystem; Propellant Storage and Distribution Subsystem; Thruster Subsystem; and Electrical Power Distribution and Control Subsystem. Volume 2 continues the presentation of IOA analysis worksheets.

Burkemper, V. J.↗

Independent Orbiter Assessment (IOA): Analysis of the reaction control system, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Reaction Control System (RCS). The RCS is situated in three independent modules, one forward in the orbiter nose and one in each OMS/RCS pod. Each RCS module consists of the following subsystems: Helium Pressurization Subsystem; Propellant Storage and Distribution Subsystem; Thruster Subsystem; and Electrical Power Distribution and Control Subsystem. Volume 3 continues the presentation of IOA analysis worksheets and the potential critical items list.

Burkemper, V. J.↗