Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Further observations of Space Shuttle plasma-electrodynamic effects from OSS-1/STS-3

Recent analyses of ion measurements obtained from the Differential Ion Flux Probe (DIFP) on the deployed Plasma Diagnostics Package (PDP) during the OSS-1/STS-3 mission have provided an additional insight into the plasma-electrodynamics of the Space Shuttle Orbiter: (1) Measured ion flow directions and energies suggest that the disturbance created in the ionospheric plasma by the Shuttle Orbiter may be confined to an interaction region that extends on the order of 10 m in the forward direction and has a boundary thickness of about 2 m. (2) A correlation between the DIFP and pressure gauge measurements indicates a direct, local proportionality between the neutral gas and ion densities. (3) Preliminary results from a theoretical model of the possible interaction between measured secondary, high inclination ion streams and the ambient plasma indicate the generation of broad-band electrostatic noise such as that observed by wave instruments on the PDP.

Stone, N. H.↗

Major results from the first plasma campaign of the Wendelstein 7-X stellarator

Here, after completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 × 10 19 m –3 , central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron transport barrier and high confinement in configurations with internal islands close to the plasma edge of W7-X

The low magnetic shear in the Wendelstein 7-X (W7-X) stellarator makes it feasible to shape the separatrix by the large islands constituting an island-divertor, and this can be exploited to access various magnetic configurations, including samples of different internal island sizes and locations. To investigate the configuration effects on the plasma confinement, a configuration scan was performed by changing the coil currents to vary the rotational transform between values 5/4 and 5/6 at the plasma boundary with different power levels (2, 4, 6 MW) of electron cyclotron resonance heating (ECRH) at a maximum plasma density of 8 × 10 19 m -2 . neutral beam injection (NBI) heating was also applied during some configurations of the scan to create a density ramp and access high densities beyond the X2 ECRH cutoff. For the magnetic configurations, where the 5/5 and 5/6 island chains were moved closer to separatrix but remaining inside the last closed flux surface, the electron cyclotron emission shows that an electron temperature, T e , pedestal develops already during ECRH heated plasma buildup phase indicating a transport barrier, and the barrier sustains irrespective of changed plasma heating conditions such as NBI in the later part of discharge. The transport barrier is broken by subsequent fast crashes, observed with multiple plasma diagnostics with characteristics such as tokamak edge localized modes, and the corresponding crash amplitude and frequency vary with plasma pressure. The impact of the transport barrier on plasma confinement can be seen through the increased core T e profile, which could be responsible for the overall increase in the stored diamagnetic energy by approximately 10% for these configurations. After the plasma heating is terminated, a backwards transition to a degraded confinement state is also observed. These observations indicate a configuration triggered high confinement mode in low shear W7-X. This work focuses on the occurrence of this transport barrier for different magnetic configurations and its relation to internal magnetic islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the performance of antennas in magnetized plasmas

The antenna studies were performed in a large magnetized plasma source, a schematic drawing of which is shown. The plasma diagnostics consist of a 70 GHz (4 mm) microwave interferometer for density measurements and of various Langmuir probes for spatially resolved measurements of t sub e, n sub e and the shape of the electron distribution function. All diagnostic data are time-resolved by sample-and-hold techniques so as to yield information about the plasma build-up, the steady-state discharge, and the plasma decay in the afterglow. Whistler waves are excited and detected with various antennas which are inserted into the center of the plasma column through one axial and two orthogonal radial ports. The antennas were tested for their proper dipole response and then calibrated in a known field geometry in air. For the electric dipole, a parallel plate capacitor field was used; the magnetic loop is calibrated in the near-zone field of a long linear conductor of known radio frequency current distribution. Results are presented and discussed.

Stenzel, R. L.↗

Solar flare X-ray spectra from the P78-1 spacecraft

Results from the high resolution solar X-ray spectrometer experiments on the P78-1 spacecraft are discussed. These results concern physical quantities such as electron temperature and density, turbulence, mass motions, and state of ionization equilibrium, characteristic of the thermal soft X-ray emitting flare plasma, and the time behavior of these quantities during flares. In addition, a brief description of the instruments is given, the plasma diagnostics used in interpreting the spectra are summarized, and the origin of the thermal soft X-ray emitting plasma is discussed in light of the P78-1 results, earlier data, and numerical simulations of magnetic flux tubes heated to solar flare temperatures.

Doschek, G. A.↗

LLNL FESP Theory Highlights: November 2024

This talk presented a refined understanding of plasma-facing thermionic emitter cathodes by examining the limitations of the conventional space charge-limited model, which overlooks ion trapping dynamics within the virtual cathode. While conventional theory distinguishes between temperature-limited and space charge-limited regimes based on electron current constraints, recent findings reveal that trapped ions can form a quasi-neutral "second plasma," expanding upstream and interacting with the primary plasma. These effects are amplified in non-planar geometries, such as cylindrical or spherical sheaths, where trapped ions create a positive feedback loop with the upstream plasma. To address these phenomena, a new "Aid-and-Compete" model was developed, offering insights into current enhancement and sheath mode transitions relevant for plasma devices, including emissive cathodes in electric propulsion, fusion applications, thin film deposition systems, and plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative electron temperature measurements of Thomson scattering and electron cyclotron emission diagnostics in TCABR plasmas

We present the first simultaneous measurements of the Thomson scattering and electron cyclotron emission radiometer diagnostics performed at TCABR tokamak with Alfven wave heating. The Thomson scattering diagnostic is an upgraded version of the one previously installed at the ISTTOK tokamak, while the electron cyclotron emission radiometer employs a heterodyne sweeping radiometer. For purely Ohmic discharges, the electron temperature measurements from both diagnostics are in good agreement. Additional Alfven wave heating does not affect the capability of the Thomson scattering diagnostic to measure the instantaneous electron temperature, whereas measurements from the electron cyclotron emission radiometer become underestimates of the actual temperature values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanisms for Pole Piece Erosion in a 6-kW Magnetically-Shielded Hall Thruster

The mechanisms contributing to the erosion of the inner magnetic pole of a 6-kW magnetically shielded Hall thruster are experimentally and numerically investigated. Sputtering from ion bombardment is believed to be the cause of this wear, but the nature and source of the responsible ions remains unknown. Laser induced fluorescence and translating and surface-mounted probes are employed to characterize the flux and energy distribution of ions incident at the inner pole. It is found that the bulk population is comprised of ions originating from the cathode plume and the near field immediately adjacent to the inner pole. These ions have a low average kinetic energy, < 5 eV kinetic, but a high thermal spread in velocity, Ti = 10 eV. Calculations for the erosion at the pole from experimental measurements indicate that the bulk population only accounts for 10-25% of the observed erosion. It is postulated that the remainder of the erosion results from a separate population of ions with sufficiently high energy (> 150 V) to cause high sputtering but too low density to be detected experimentally by the plasma diagnostics in this region. The existence for this high energy population is shown to be a consequence of the high plasma potentials downstream of the thruster exit plane that are characteristic of a magnetically-shielded topography. A simulation validated by experimental measurements of the thruster provides further evidence that a high energy ion populations exists with sufficient density to explain the observed erosion.

Jorns, Benjamin A.↗

Visualization of Multi-Dimensional Imaging Data for the DIII-D National Fusion Facility

With funding provided from the Office of Fusion Energy Science’s program on Diagnostic Systems for Magnetic Fusion Energy Sciences, the PI and his team have pioneered the development of microwave imaging systems for magnetic fusion plasma diagnostics. Specifically, electron cyclotron emission (ECE) imaging [1], a passive radiometric technique, measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) [2], an active radar imaging technique, measures electron density fluctuations. These microwave imaging diagnostic instruments developed by UC Davis have made important contributions to fusion science in a relatively short period of time from their original installation on DIII-D. The microwave imaging diagnostic technique has matured considerably since the beginning of a fruitful collaboration with DIII-D and PPPL, and has also been adopted at preeminent tokamak facilities worldwide. As discussed in detail in the following, this has continued with the development of revolutionary microwave diagnostic instruments employing monolithic millimeter wave integrated circuit (MMIC) system-on-chip (SoC) technology. Specifically, “chip” receivers mounted in liquid crystal polymer (LCP) modules have been demonstrated to dramatically improve the performance of the electron cyclotron emission imaging (ECEI) system including: 30x improvement in noise temperature thereby permitting absolute 2-D electron temperature images, outstanding shielding against out-of-band interference including microwave bursting which had plagued previous ELM studies using the old quasi-optical mini-lens ECEI system, and independent modules facilitating flexible repair and replacement. Under the “Visualization of multi-dimensional imaging data for the DIII-D National Fusion Facility” program, funding was provided for a research scientist postdoc and a Ph.D. student to support physics studies at DIII-D employing these instruments. This endeavor is synergistic with our current grant under the DOE Fusion Energy Sciences (FES) program on Diagnostic Systems for Magnetic Fusion Energy Sciences. This support considerably increased the scientific output of the diagnostics. The activities were strongly focused in the areas of pedestal and ELM stability, energetic particle confinement, and the early detection and avoidance of tokamak disruptions employing the microwave imaging diagnostic instruments developed under the advanced diagnostics program where imaging of the ELM crash was made possible by the elimination of the interference from the associated microwave “bursts”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction between electromagnetic waves and plasma waves in motional plasma

The electromagnetic wave (EM wave) behavior and the electromagnetic instability caused by the interaction between an EM wave and a plasma wave in motional plasma are studied. The dispersion relation of EM waves and the dielectric tensor of motional plasma are derived by magnetohydrodynamics, and the wave phenomenon in motional plasma is displayed. As a result, the electromagnetic instability, which is excited by the interaction between the EM waves and the plasma waves, is revealed. The mechanism of the instability is the coupling between high frequency electromagnetic field and the transverse electron oscillation derived from the deflection of longitudinal electron oscillation due to self-magnetic field. The present research is useful with regard to the new type of plasma radiation source, ion-focusing accelerator, and plasma diagnostic technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The contribution of dissociative processes to the production of atomic lines in hydrogen plasmas

The contribution of molecular dissociative processes to the production of atomic lines is considered for a steady-state hydrogen plasma. If the contribution of dissociative processes is dominant, a substantial simplification in plasma diagnostics can be achieved. Numerical calculations have been performed for the production of Balmer alpha, beta, and gamma lines in hydrogen plasmas with medium and large degrees of ionization (x greater than about 0.0001) and for electron temperatures of 5000-45,000 K and electron densities of 10 to the 10th to 10 to the 16th/cu cm.

Kunc, J. A.↗

Experimental Investigation of Active Feedback Control of Turbulent Transport in a Magnetized Plasma

A new and unique basic plasma science laboratory device - the HelCat device (HELicon-CAThode) - has been constructed and is operating at the University of New Mexico. HelCat is a 4 m long, 0.5 m diameter device, with magnetic field up to 2.2 kG, that has two independent plasmas sources - an RF helicon source, and a thermionic cathode. These two sources, which can operate independently or simultaneously, are capable of producing plasmas with a wide range of parameters and turbulence characteristics, well suited to a variety of basic plasma physics experiments. An extensive set of plasma diagnostics is also operating. Experiments investigating the active feedback control of turbulent transport of particles and heat via electrode biasing to affect plasma ExB flows are underway, and ongoing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analysis Progress of ITER Diagnostic Equatorial Port #09

ITER is the world's largest fusion device currently under construction in the South of France with >50 diagnostic systems to be installed inside the port plugs (PPs), the interspace (IS), or the port cell region of various diagnostic ports. The plasma facing diagnostic first wall (DFW) and its supporting diagnostic shield modules (DSM) are designed to protect front-end diagnostics from plasma neutron and plasma radiation, while providing apertures for diagnostic access to the plasma. The design of ITER port plug structures including the DFW and the DSM is largely driven by the electromagnetic loads included on the PP structural components during plasma major disruptions and the vertical displacement events (VDEs). Unlike DFW and DSM, the design of diagnostic system, however, is likely driven by the steady-state thermal loads from plasma volumetric and surface heating and the dynamic response of the in-port components attached to the port-specific DSM or closure plate under transient loads induced on the vacuum vessel and the port extension during asymmetric VDEs. Three tenant diagnostic systems are integrated into the equatorial port 09. The toroidal interferometer/polarimeter, or TIP system, is installed in the left drawer (DSM3, left looking from plasma) for measuring the plasma density so to control the fuel input. The electron cyclotron emission (ECE) system is installed in the middle drawer (DSM2) to provide the high spatial and temporal resolution measurements of electron temperature evolution and the electron thermal transport inferences. The visible/infrared wide angle viewing system is installed in the right drawer (DSM1) to provide visible and infrared viewing and temperature data of the first wall for its protection in support of machine operation. The port plug integration design and multiphysics analyses are performed following port integration requirements including the weight limit (45 tones total), shut down dose rate limits, the cooling/heating and structural integrity validation. Mass distribution for TIP and ECE DSMs has been optimized to minimize the total weight by a new design of the boron carbide shielding pocket. Furthermore, the lightened DSM maintains its front-end load distribution and the structural stiffness with minimum impact to the DFW so to better protect on-board diagnostics; while still provides sufficient front-end stiffness for its structural integrity as well as the diagnostics function requirements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Langmuir and Spatially Resolved OES Diagnostics for Arc Jet Shock and Boundary Layer Measurements Relevant to Atmospheric Re-Entry Environments

The second-generation miniature Arc Jet Research Chamber (mARC) ground testing facility at NASA Ames requires physical characterization of its supersonic plasma flow to verify numerical models and material sample testing. Two types of plasma diagnostics will be utilized: Langmuir probes and optical emission spectroscopy (OES). Several single and triple Langmuir probes have been constructed and will be inserted parallel to the flow via a sweep arm to measure post-shock electron temperature and number density along radial profiles at different axial distances. Due to the high heat flux (200-3000 W/cm2) sweep durations are necessarily short (< 0.1 s). Measuring these properties near the probe surface provide characterization of the post-shock environment. This is an important metric for validating coupled CFD-material codes, and will provide insight into longstanding thermocouple anomalies attributed to charging of heatshield surfaces. An OES system has also been assembled to obtain spatially resolved density and temperature for various flow species. The system consists of a convex lens that forms an image of the plasma onto a 16-channel linear fiber array, which will simultaneously capture the spectra from sixteen different locations. The light emission from the plasma is then focused by a spherical mirror into a spectrometer and recorded with a camera. These measurements non-intrusively provide a new spatially resolved flow characterization capability. This will initially be used to resolve issues with shock radiation interference in pyrometer measurements of material surface temperature. The design of each diagnostic and any initial results will be discussed.

Ethan Main-Loam Leong↗

Response measurement of single-crystal chemical vapor deposition diamond radiation detector for intense X-rays aiming at neutron bang-time and neutron burn-history measurement on an inertial confinement fusion with fast ignition

A neutron bang time and burn history monitor in inertial confinement fusion with fast ignition are necessary for plasma diagnostics. In the FIREX project, however, no detector attained those capabilities because high-intensity X-rays accompanied fast electrons used for plasma heating. To solve this problem, single-crystal CVD diamond was grown and fabricated into a radiation detector. The detector, which had excellent charge transportation property, was tested to obtain a response function for intense X-rays. The applicability for neutron bang time and burn history monitor was verified experimentally. Charge collection efficiency of 99.5% ± 0.8% and 97.1% ± 1.4% for holes and electrons were obtained using 5.486 MeV alpha particles. The drift velocity at electric field which saturates charge collection efficiency was 1.1 ± 0.4 × 10{sup 7} cm/s and 1.0 ± 0.3 × 10{sup 7} cm/s for holes and electrons. Fast response of several ns pulse width for intense X-ray was obtained at the GEKKO XII experiment, which is sufficiently fast for ToF measurements to obtain a neutron signal separately from X-rays. Based on these results, we confirmed that the single-crystal CVD diamond detector obtained neutron signal with good S/N under ion temperature 0.5–1 keV and neutron yield of more than 10{sup 9} neutrons/shot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma-droplet interaction study to assess transport limitations and the role of • OH, O • ,H • ,O 2 (a 1 Δ g ),O 3 , He(2 3 S) and Ar(1s 5 ) in formate decomposition

Plasmas interacting with liquid microdroplets are gaining momentum due to their ability to significantly enhance the reactivity transfer from the gas phase plasma to the liquid. This is, for example, critically important for efficiently decomposing organic pollutants in water. In this contribution, the role of •OH as well as non-•OH-driven chemistry initiated by the activation of small water microdroplets in a controlled environment by diffuse RF glow discharge in He with different gas admixtures (Ar, O 2 and humidified He) at atmospheric pressure is quantified. The effect of short-lived radicals such as O• and H• atoms, singlet delta oxygen (O 2 (a 1 Δ g )), O 3 and metastable atoms of He and Ar, besides •OH radicals, on the decomposition of formate dissolved in droplets was analyzed using detailed plasma diagnostics, droplet characterization and ex situ chemical analysis of the treated droplets. The formate decomposition increased with increasing droplet residence time in the plasma, with ~70% decomposition occurring within ~15 ms of the plasma treatment time. The formate oxidation in the droplets is shown to be limited by the gas phase •OH flux at lower H 2 O concentrations with a significant enhancement in the formate decomposition at the lowest water concentration, attributed to e – /ion-induced reactions. However, the oxidation is diffusion limited in the liquid phase at higher gaseous •OH concentrations. Here, the formate decomposition in He/O 2 plasma was similar, although with an order of magnitude higher O• radical density than the •OH density in the corresponding He/H 2 O plasma. Using a one-dimensional reaction–diffusion model, we showed that O 2 (a 1 Δ g ) and O 3 did not play a significant role and the decomposition was due to O•, and possibly •OH generated in the vapor containing droplet-plasma boundary layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics of fast formation of distributed plasma discharges using X-band microwaves

We present measurements of high power (25.7 kW), pulsed (800 ns), X-band (9.382 GHz) microwave breakdown plasmas, including reflected power measurements, mixer reflected amplitude and phase measurements, optical emission spectroscopy (OES) measurements, and an analysis that estimates the average electron density and electron temperature. In addition, a six-region, 1-D model was used to determine plasma parameters and compare with the experimental results. The experimental results show that using a 43 Hz repetition rate with an 800 ns pulse, fast (<300 ns) breakdown occurs in neon measured between 50 Torr and 250 Torr, producing plasma that lasts for over 7 μs. It also leads to large microwave reflections (70%) and an on-axis transmission attenuation of −15 dB. Moreover, a comparison between a 1-D model and mixer measurements shows that at 100 Torr, the neon plasma electron density peaked at 2 × 10{sup 12} cm{sup −3}, and the electron temperature peaked at 2.5 eV assuming a Maxwellian distribution. The addition of 2% Ar in Ne reduced the breakdown time and allowed OES measurements to determine the effective electron temperature. OES measurements of mixed (Ne/Ar: 98/2) argon line ratios (420.1 nm/419.8 nm) were used to determine the average effective electron temperature T{sub e(eff)} = 1.2 eV, averaged over the entire 7μs plasma lifetime. They indicate that the electron energy distribution was not Maxwellian but, instead, tended towards a Druyvesteyn character.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗