Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-11: Radiobiological-Cum-Dosimetric Quality Assurance of Complex Radiotherapy Plans

Purpose: Dosimetric gamma-analysis used for QA of complex radiotherapy plans tests the dosimetric equivalence of a delivered plan with the treatment planning system (TPS) optimized plan. It does not examine whether a dosimetric difference results in any radiobiological difference. This study introduces a method to test the radiobiological and dosimetric equivalence between a delivered and the TPS optimized plan. Methods: Six head and neck and seven lung cancer VMAT or IMRT plans optimized for patient treatment were calculated and delivered to an ArcCheck phantom. ArcCheck measured dose distributions were compared with the TPS calculated dose distributions using a 2-D gamma-analysis. Dose volume histograms (DVHs) for various patient structures were obtained by using measured data in 3DVH software and compared against the TPS calculated DVHs using 3-D gamma analysis. DVH data were used in the Poisson model to calculate tumor control probability (TCP) for the treatment targets and in the sigmoid dose response model to calculate normal tissue complication probability (NTCP) for the normal structures. Results: Two-D and three-D gamma passing rates among six H&N patient plans differed by 0 to 2.7% and among seven lung plans by 0.1 to 4.5%. Average ± SD TCPs based on measurement and TPS were 0.665±0.018 and 0.674±0.044 for H&N, and 0.791±0.027 and 0.733±0.031 for lung plans, respectively. Differences in NTCPs were usually negligible. The differences in dosimetric results, TCPs and NTCPs were insignificant. Conclusion: The 2-D and 3-D gamma-analysis based agreement between measured and planned dose distributions may indicate their dosimetric equivalence. Small and insignificant differences in TCPs and NTCPs based on measured and planned dose distributions indicate the radiobiological equivalence between the measured and optimized plans. However, patient plans showing larger differences between 2-D and 3-D gamma-analysis can help us make a more definite conclusion through our ongoing research with a larger number of patients.

60 APPLIED LIFE SCIENCES↗

Data-Driven Approach to Generating Achievable Dose-Volume Histogram Objectives in Intensity-Modulated Radiotherapy Planning

Purpose: To propose a method of intensity-modulated radiotherapy (IMRT) planning that generates achievable dose-volume histogram (DVH) objectives using a database containing geometric and dosimetric information of previous patients. Methods and Materials: The overlap volume histogram (OVH) is used to compare the spatial relationships between the organs at risk and targets of a new patient with those of previous patients in a database. From the OVH analysis, the DVH objectives of the new patient were generated from the database and used as the initial planning goals. In a retrospective OVH-assisted planning demonstration, 15 patients were randomly selected from a database containing clinical plans (CPs) of 91 previous head-and-neck patients treated by a three-level IMRT-simultaneous integrated boost technique. OVH-assisted plans (OPs) were planned in a leave-one-out manner by a planner who had no knowledge of CPs. Thus, DVH objectives of an OP were generated from a subdatabase containing the information of the other 90 patients. Those DVH objectives were then used as the initial planning goals in IMRT optimization. Planning efficiency was evaluated by the number of clicks of the 'Start Optimization' button in the course of planning. Although the Pinnacle{sup 3} treatment planning system allows planners to interactively adjust the DVH parameters during optimization, planners in our institution have never used this function in planning. Results: The average clicks required for completing the CP and OP was 27.6 and 1.9, respectively (p <.00001); three OPs were finished within a single click. Ten more patient's cord + 4 mm reached the sparing goal D{sub 0.1cc} <44 Gy (p <.0001), where D{sub 0.1cc} represents the dose corresponding to 0.1 cc. For planning target volume uniformity, conformity, and other organ at risk sparing, the OPs were at least comparable with the CPs. Additionally, the averages of D{sub 0.1cc} to the cord + 4 mm decreased by 6.9 Gy (p <.0001); averages of D{sub 0.1cc} to the brainstem decreased by 7.7 Gy (p <.005). The averages of V(30 Gy) to the contralateral parotid decreased by 8.7% (p <.0001), where V(30 Gy) represents the percentage volume corresponding to 30 Gy. Conclusion: The method heralds the possibility of automated IMRT planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-134: Can We Use the Same Dose Constrains Learnt From Photon World to Plan Proton for Lung Cancer?

Purpose: To evaluate if the same DVH constrains used in photon plans can be safely used to plan proton therapy for lung cancer. Since protons and photons have different dose deposition patterns, the hypothesis is following DVH constrains derived from photon world is not safe for proton. Methods: We retrospectively evaluated plans for 11 lung cancer patients. Each patient was planned with photon and proton following the same dose constrains. Dose statistics on PTV, normal lung, heart and esophagus were extracted for comparison. gEUD for normal lung was calculated and compared between proton and photon plans. We calculated series of gEUDs for each plan by varying the parameter “a” in gEUD formula from 0.1 to 3, covering the whole confidence interval. Results: For all patients, proton plans yield similar PTV coverage and lower dose to heart and esophagus than photon plans. Normal lung V5 was 32.3 % on average in proton plans than 55.4 % in photon. Normal lung gEUD monotonically increased with increasing “a” for all proton and photon plans. For a given patient, the gEUD-proton(a) had a steeper slope than gEUD-photon(a). The two curves crossed for 8 out of 11 patients when “a” = [0.1, 3]. a-crossing ranged from 0.8 to 2.44 with an average of 1.15. For a<a-crossing, gEUD-proton was less than gEUD-photon and vice versa. Conclusion: The current clinical guideline is the lower normal lung V5 would associated with less complications. However, proton plans with a lower normal lung V5 could yield a higher gEUD than photon if the real “a” is larger than a-crossing. Since a-crossing was within the possible range of real “a”, simply following the normal lung V5 guideline for proton plan would not be a good practice. More comprehensive methods should be developed to evaluate the proton plan.

60 APPLIED LIFE SCIENCES↗

Using Correlation to Compute Better Probability Estimates in Plan Graphs

Plan graphs are commonly used in planning to help compute heuristic "distance" estimates between states and goals. A few authors have also attempted to use plan graphs in probabilistic planning to compute estimates of the probability that propositions can be achieved and actions can be performed. This is done by propagating probability information forward through the plan graph from the initial conditions through each possible action to the action effects, and hence to the propositions at the next layer of the plan graph. The problem with these calculations is that they make very strong independence assumptions - in particular, they usually assume that the preconditions for each action are independent of each other. This can lead to gross overestimates in probability when the plans for those preconditions interfere with each other. It can also lead to gross underestimates of probability when there is synergy between the plans for two or more preconditions. In this paper we introduce a notion of the binary correlation between two propositions and actions within a plan graph, show how to propagate this information within a plan graph, and show how this improves probability estimates for planning. This notion of correlation can be thought of as a continuous generalization of the notion of mutual exclusion (mutex) often used in plan graphs. At one extreme (correlation=0) two propositions or actions are completely mutex. With correlation = 1, two propositions or actions are independent, and with correlation > 1, two propositions or actions are synergistic. Intermediate values can and do occur indicating different degrees to which propositions and action interfere or are synergistic. We compare this approach with another recent approach by Bryce that computes probability estimates using Monte Carlo simulation of possible worlds in plan graphs.

Bryce, Daniel↗

Distribution System Planning - State Examples by Topic

The U.S. Department of Energy (DOE) recently completed a study on how regulators in 16 states have dealt with questions related to distribution system planning (DSP) and distributed energy resource (DER) utilization. During the study, DOE and three of its national laboratories developed a significant amount of information on state-level activities including grid modernization planning; distribution planning; tools for integrating distributed energy resources (DERs) (e.g., hosting capacity analysis and tools for maximizing the value of DERs to the distribution system such as locational value analyses); and linkages between distribution planning and related processes such as cost recovery through general rate cases or rate surcharges. The Oregon Public Utility Commission (Commission) requested assistance from DOE on a list of specific questions related to DSP. The Commission was specifically interested in identifying guidance on the creation of comprehensive and transparent utility distribution system plans; on the linkages between such plans and other utility planning processes such as integrated resource planning; improved forecasting and representation of DERs in distribution system plans and other plans such as integrated resource planning; valuation of DERs; and a roadmap for optimized locational planning for DERs. In response to their interests, we have identified 1) specific topics from the original study that would be of assistance to the Commission and 2) states that could provide potential examples or templates to draw from. In this report, we have summarized and reorganized the pertinent original material by subject. We also developed a matrix that points to specific examples for each topic and provide one or two paragraph summaries of each possible template for each topic area with web links directly to the source documents. For some cases in which states have taken significant steps since the publication of the original DOE study, the original source information has been supplemented to ensure the information provided to the Commission remains current. Finally, we called out a small number of especially pertinent or immediately useful documents and have highlighted these in the introductory section. This report documents the material developed for the Oregon Commission by DOE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Oncentra® Brachy IPSA and graphical optimisation techniques: a case study of HDR brachytherapy head and neck and prostate plans

There are a number of different dwell positions and time optimisation options available in the Oncentra® Brachy (Elekta Brachytherapy Solutions, Veenendaal, The Netherlands) brachytherapy treatment planning system. The purpose of this case study was to compare graphical (GRO) and inverse planning by simulated annealing (IPSA) optimisation techniques for interstitial head and neck (HN) and prostate plans considering dosimetry, modelled radiobiology outcome and planning time. Four retrospective brachytherapy patients were chosen for this study, two recurrent HN and two prostatic boosts. Manual GRO and IPSA plans were generated for each patient. Plans were compared using dose–volume histograms (DVH) and dose coverage metrics including; conformity index (CI), homogeneity index (HI) and conformity number (CN). Logit and relative seriality models were used to calculate tumour control probability (TCP) and normal tissue complication probability (NTCP). Approximate planning time was also recorded. There was no significant difference between GRO and IPSA in terms of dose metrics with mean CI of 1.30 and 1.57 (P > 0.05) respectively. IPSA achieved an average HN TCP of 0.32 versus 0.12 for GRO while for prostate there was no significant difference. Mean GRO planning times were greater than 75 min while average IPSA planning times were less than 10 min. Planning times for IPSA were greatly reduced compared to GRO and plans were dosimetrically similar. For this reason, IPSA makes for a useful planning tool in HN and prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer

Purpose: Automated and knowledge-based planning techniques aim to reduce variations in plan quality. RapidPlan uses a library consisting of different patient plans to make a model that can predict achievable dose-volume histograms (DVHs) for new patients and uses those models for setting optimization objectives. We benchmarked RapidPlan versus clinical plans for 2 patient groups, using 3 different libraries. Methods and Materials: Volumetric modulated arc therapy plans of 60 recent head and neck cancer patients that included sparing of the salivary glands, swallowing muscles, and oral cavity were evenly divided between 2 models, Model{sub 30A} and Model{sub 30B}, and were combined in a third model, Model{sub 60}. Knowledge-based plans were created for 2 evaluation groups: evaluation group 1 (EG1), consisting of 15 recent patients, and evaluation group 2 (EG2), consisting of 15 older patients in whom only the salivary glands were spared. RapidPlan results were compared with clinical plans (CP) for boost and/or elective planning target volume homogeneity index, using HI{sub B}/HI{sub E} = 100 × (D2% − D98%)/D50%, and mean dose to composite salivary glands, swallowing muscles, and oral cavity (D{sub sal}, D{sub swal}, and D{sub oc}, respectively). Results: For EG1, RapidPlan improved HI{sub B} and HI{sub E} values compared with CP by 1.0% to 1.3% and 1.0% to 0.6%, respectively. Comparable D{sub sal} and D{sub swal} values were seen in Model{sub 30A}, Model{sub 30B}, and Model{sub 60}, decreasing by an average of 0.1, 1.0, and 0.8 Gy and 4.8, 3.7, and 4.4 Gy, respectively. However, differences were noted between individual organs at risk (OARs), with Model{sub 30B} increasing D{sub oc} by 0.1, 3.2, and 2.8 Gy compared with CP, Model{sub 30A}, and Model{sub 60}. Plan quality was less consistent when the patient was flagged as an outlier. For EG2, RapidPlan decreased D{sub sal} by 4.1 to 4.9 Gy on average, whereas HI{sub B} and HI{sub E} decreased by 1.1% to 1.5% and 2.3% to 1.9%, respectively. Conclusions: RapidPlan knowledge-based treatment plans were comparable to CP if the patient's OAR-planning target volume geometry was within the range of those included in the models. EG2 results showed that a model including swallowing-muscle and oral-cavity sparing can be applied to patients with only salivary gland sparing. This may allow model library sharing between institutes. Optimal detection of inadequate plans and population of model libraries requires further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Planning for Primary Prostate Cancer With Selective Intraprostatic Boost Determined by {sup 18}F-Choline PET/CT

Purpose: This study evaluated expected tumor control and normal tissue toxicity for prostate volumetric modulated arc therapy (VMAT) with and without radiation boosts to an intraprostatically dominant lesion (IDL), defined by {sup 18}F-choline positron emission tomography/computed tomography (PET/CT). Methods and Materials: Thirty patients with localized prostate cancer underwent {sup 18}F-choline PET/CT before treatment. Two VMAT plans, plan{sub 79} {sub Gy} and plan{sub 100-105} {sub Gy}, were compared for each patient. The whole-prostate planning target volume (PTV{sub prostate}) prescription was 79 Gy in both plans, but plan{sub 100-105} {sub Gy} added simultaneous boost doses of 100 Gy and 105 Gy to the IDL, defined by 60% and 70% of maximum prostatic uptake on {sup 18}F-choline PET (IDL{sub suv60%} and IDL{sub suv70%}, respectively, with IDL{sub suv70%} nested inside IDL{sub suv60%} to potentially enhance tumor specificity of the maximum point dose). Plan evaluations included histopathological correspondence, isodose distributions, dose-volume histograms, tumor control probability (TCP), and normal tissue complication probability (NTCP). Results: Planning objectives and dose constraints proved feasible in 30 of 30 cases. Prostate sextant histopathology was available for 28 cases, confirming that IDL{sub suv60%} adequately covered all tumor-bearing prostate sextants in 27 cases and provided partial coverage in 1 case. Plan{sub 100-105} {sub Gy} had significantly higher TCP than plan{sub 79} {sub Gy} across all prostate regions for α/β ratios ranging from 1.5 Gy to 10 Gy (P<.001 for each case). There were no significant differences in bladder and femoral head NTCP between plans and slightly lower rectal NTCP (endpoint: grade ≥ 2 late toxicity or rectal bleeding) was found for plan{sub 100-105} {sub Gy}. Conclusions: VMAT can potentially increase the likelihood of tumor control in primary prostate cancer while observing normal tissue tolerances through simultaneous delivery of a steep radiation boost to a {sup 18}F-choline PET-defined IDL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computerized System for Safety Verification of External Beam Radiation Therapy Planning

Purpose: To report an assessment of in-house software, Verifier, developed to improve efficacy and efficiency of the radiation therapy (RT) treatment planning process and quality control review (QCR). Methods and Materials: Radiation therapy plan parameters retrieved from our treatment planning database are used by automated tests to give 75 types of warnings, such as prescription and plan discrepancies. The software is continuously updated on the basis of new issues, ideas, and planning policies. Verifier was retrospectively assessed (2007-2015) by examining impact on treatment plan revisions, frequency of quality improvement incident reports of avoidable RT plan-related safety events, unaddressed issues, and staff efficiency. Results: Plan revisions for specific issues declined dramatically in response to implementation of corresponding Verifier tests. Between 2012 and 2015 our institution's total rate of plan revisions dropped from 18.0% to 11.2%. Between 2008 and 2015 specific tests were added to Verifier while the rate of corresponding avoidable safety events was reduced from 0.34% to 0.00% over the same period. Simulations suggest Verifier saves approximately 2 to 5 minutes per QCR. Conclusions: The decrease in quantifiable metrics of plan revisions and incident reports suggests automatic RT plan-checking software enhances patient safety and clinical efficiency. Although only modest time savings may be gained using Verifier for the QCR itself, the greater impact on efficiency is through avoiding late-stage plan modifications and improving documentation via automation. We encourage other institutions to consider working toward adding similar technologies to enhance their RT quality assurance programs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each 'planning scan' to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline

Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique has comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.

61 RADIATION PROTECTION AND DOSIMETRY↗

A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based stereotactic body radiotherapy for central early-stage non−small cell lung cancer

We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non−small cell lung cancer with a tri-cobalt-60 (tri-{sup 60}Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)–based SBRT. In all, 20 patients with large central early-stage non−small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-{sup 60}Co system for a prescription dose of 50 Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R{sub 100} values were calculated as the total tissue volume receiving 100% of the dose (V{sub 100}) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-{sup 60}Co SBRT plans were performed using Student's t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3 cc (range: 12.1 to 139.4 cc). Of the tri-{sup 60}Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R{sub 100} values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-{sup 60}Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-{sup 60}Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further investigation in a prospective feasibility clinical trial.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-43: Deformed Planning CT as An Electron Density Substitute for Cone-Beam CT

Purpose: To confirm that deforming the planning CT to the daily Cone-Beam CTs (CBCT) can provide suitable electron density for adaptive planning. We quantify the dosimetric difference between plans calculated on deformed planning CTs (DPCT) and daily CT-on-rails images (CTOR). CTOR is used as a test of the method as CTOR already contains accurate electron density to compare against. Methods: Five prostate only IMRT patients, each with five CTOR images, were selected and re-planned on Panther (Prowess Inc.) with a uniform 5 mm PTV expansion, prescribed 78 Gy. The planning CT was deformed to match each CTOR using ABAS (Elekta Inc.). Contours were drawn on the CTOR, and copied to the DPCT. The original treatment plan was copied to both the CTOR and DPCT, keeping the center of the prostate as the isocenter. The plans were then calculated using the collapsed cone heterogeneous dose engine of Prowess and typical DVH planning parameters used to compare them. Results: Each DPCT was visually compared to its CTOR with no differences observed. The agreement of the copied CTOR contours with the DPCT anatomy further demonstrated the deformation accuracy. The plans calculated using CTOR and DPCT were compared. Over the 25 plan pairs, the average difference between them for prostate D100, D98 and D95 were 0.5%, 0.2%, and 0.2%; PTV D98, D95 and mean dose: 0.3%, 0.2% and 0.3%; bladder V70, V60 and mean dose: 1.1%, 0.7%, and 0.2%; and rectum mean dose: 0.3%. (D100 is the dose covering 100% of the target; V70 is the volume of the organ receiving 70 Gy). Conclusion: We observe negligible difference between the dose calculated on the DPCT and the CTOR, implying that deformed planning CTs are a suitable substitute for electron density. The method can now be applied to CBCTs. Research version of Panther provided by Prowess Inc. Research version of ABAS provided by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity.

60 APPLIED LIFE SCIENCES↗