Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A novel network-based approach to determining measurement representation error for model evaluation of aerosol microphysical properties

Atmospheric aerosol size and abundance influence radiative effects and climate change. To date, efforts to constrain global climate models’ radiative forcing with in situ aerosol observations have been hamstrung by uncertainty. One source of error, the regional “representation error,” arises when accurate but sparse single-point measurements of atmospheric aerosol distributions are compared with a model value, assuming that the single-point measurement is representative of the model domain. The Portable Optical Particle Spectrometer network in the Southern Great Plains (POPSnet-SGP) campaign has demonstrated that a network of nearly autonomous aerosol instruments operating at ambient temperature and relative humidity (with low measurement error) may be used to quantify measurement representation error and investigate the factors introducing heterogeneity in aerosol distributions across a rural, continental background region. Measurements were made using Portable Optical Particle Spectrometer (POPS) instruments at several sites for five months across the Department of Energy’s Aerosol Radiation Measurement Southern Great Plains (ARM-SGP) User Facility in the central USA. Measurement representation error decreased with longer averaging periods (20-40 % between 1 sec and 1 day), varied between sites by 10 – 20 % for aerosol concentration 140 – 2500 nm in diameter (N_140), and was higher for aerosols > 400 nm in diameter (N_400). Our measurements also show the influence of local meteorology on aerosol surface area (A_140) and size distributions: A_140 is positively correlated with wind speed and relative humidity, negatively correlated with precipitation, and lower given westerly winds. Based on this study, we conclude that the POPSnet approach provides considerably more insight into the spatial variability in the aerosol population that can be used to constrain climate models than would be available from similar networks of PM 2.5 monitors.

54 ENVIRONMENTAL SCIENCES↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Sensing via Acoustic Sensing Fiber with Metglas® 2605SC Cladding Wires

Magnetic field sensing has the potential to become necessary as a critical tool for long-term subsurface geophysical monitoring. The success of distributed fiber optic sensing for geophysical characterization provides a template for the development of next generation downhole magnetic sensors. In this study, Sentek Instrument’s picoDAS is coupled with a multi-material single mode optical fiber with Metglas® 2605SC cladding wire inclusions for magnetic field detection. The response of acoustic sensing fibers with one and two Metglas® 2605SC cladding wires was evaluated upon exposure to lateral AC magnetic fields. An improved response was demonstrated for a sensing fiber with in-cladding wire following thermal magnetic annealing (~400 °C) under a constant static transverse magnetic field (~200 μT). A minimal detectable magnetic field of ~500 nT was confirmed for a sensing fiber with two 10 μm cladding wires. The successful demonstration of a magnetic field sensing fiber with Metglas® cladding wires fabricated via traditional draw processes sets the stage for distributed measurements and joint inversion as a compliment to distributed fiber optic acoustic sensors.

Dejneka, Zach (ORCID:0000000179415708)↗

Overview of the Fiber System for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI's success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ~f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

79 ASTRONOMY AND ASTROPHYSICS↗

Controlling cantilevered adaptive X-ray mirrors

Modeling the behavior of a prototype cantilevered X-ray adaptive mirror (held from one end) demonstrates its potential for use on high-performance X-ray beamlines. Similar adaptive mirrors are used on X-ray beamlines to compensate optical aberrations, control wavefronts and tune mirror focal distances at will. Controlled by 1D arrays of piezoceramic actuators, these glancing-incidence mirrors can provide nanometre-scale surface shape adjustment capabilities. However, significant engineering challenges remain for mounting them with low distortion and low environmental sensitivity. Finite-element analysis is used to predict the micron-scale full actuation surface shape from each channel and then linear modeling is applied to investigate the mirrors' ability to reach target profiles. Using either uniform or arbitrary spatial weighting, actuator voltages are optimized using a Moore–Penrose matrix inverse, or pseudoinverse, revealing a spatial dependence on the shape fitting with increasing fidelity farther from the mount.

47 OTHER INSTRUMENTATION↗

Development of a Radiation-Tolerant Front End Digitizer

High-radiation and high-temperature environments represent notoriously detrimental conditions for electronics. Yet sensors and instrumentation are critically important for the safe operation of nuclear reactors and for the validity of the scientific experiments conducted within them. Traditionally, sensors in such extreme environments operate with few active components, resulting in small signals (mV–V, nA–µA range) that must be transmitted through long cable runs before digitization by sensitive data acquisition systems located in clean, less-harsh environments. Long cables are prone to picking up noise through electromagnetic interference and distortion caused by their parasitic impedances, resulting in signal degradation. The Front End Digitizer (FREND) system described and demonstrated herein seeks to address these issues by enabling the placement of a radiation-resistant analog front end within reactor containment, or other high-radiation environments. FREND will enable early signal pre-amplification, digitization, and optical encoding within the high-radiation field to transmit sensor signals over an optical fiber to the non-nuclear environment of an instrument room. Early signal pre-amplification and digitization maintain signal integrity, whereas optical transmission renders the system blind to induced electromagnetic noise over the long cable runs. This report describes the FREND initial prototype, which can multiplex and optically encode data from up to four sensor inputs, though, in principle, this can be extended to any number of sensor inputs. The end result is an extremely flexible, high-fidelity system.

42 ENGINEERING↗

Dopant, coating, and grating effects in silica optical fibers under extreme neutron irradiation

Radiation effects on fiber Bragg gratings (FBGs) have been studied but data gaps related to the effects of displacement damage resulting from high fast neutron fluence remain. In this work, Type-I and Type-II FBGs inscribed in optical fibers with various core dopants (Ge and F) and fiber coatings (acrylate, polyimide) were monitored in situ during 75 days of neutron irradiation to a peak fast (>0.1 MeV) neutron fluence of 3 X 10 21 n fast /cm 2 . Further, the reflected intensity of the Type-I FBGs inscribed in a Ge-doped core fiber decreased by > 30 dB within 7 h of irradiation (10 19 n fast /cm 2 ), whereas Type-II FBGs inscribed in a pure silica core fiber eventually approached >40 dB attenuation after accumulating a fast neutron fluence on the order of 10 20 n fast /cm 2 . Type-II FBGs inscribed in F-doped core fiber improved stability: the attenuation approached an equilibrium value in the range of 10 to 20 dB.

47 OTHER INSTRUMENTATION↗

Radiation-hard miniature optical engine with high bandwidth

Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.

47 OTHER INSTRUMENTATION↗

Simultaneous bright- and dark-field X-ray microscopy at X-ray free electron lasers

Abstract The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior. Synchrotron X-ray diffraction based imaging has long mapped the deeply embedded structural elements, and with enhanced resolution, dark field X-ray microscopy (DFXM) can now map those features with the requisite nm-resolution. However, these techniques still suffer from the required integration times due to limitations from the source and optics. This work extends DFXM to X-ray free electron lasers, showing how the $$10^{12}$$ 10 12 photons per pulse available at these sources offer structural characterization down to 100 fs resolution (orders of magnitude faster than current synchrotron images). We introduce the XFEL DFXM setup with simultaneous bright field microscopy to probe density changes within the same volume. This work presents a comprehensive guide to the multi-modal ultrafast high-resolution X-ray microscope that we constructed and tested at two XFELs, and shows initial data demonstrating two timing strategies to study associated reversible or irreversible lattice dynamics.

47 OTHER INSTRUMENTATION↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗

Measuring Intermolecular Excited State Geometry for Favorable Singlet Fission in Tetracene

Singlet fission (SF) is the process of converting an excited singlet to a pair of excited triplets. Harvesting two charges from a single photon has the potential to increase photovoltaic device efficiencies. Acenes, such as tetracene and pentacene, are model molecules for studying SF. Despite SF being an endoergic process for tetracene and exoergic for pentacene, both acenes exhibit near unity SF quantum efficiencies, raising questions about how tetracene can overcome the energy barrier. Here, we use recently developed instrumentation to measure inelastic neutron scattering (INS) while optically exciting the model molecules using two different excitation energies. The spectroscopic results reveal intermolecular structural relaxation due to the presence of a triplet excited state. Here, the structural dynamics of the combined excited state molecule and surrounding tetracene molecules are further studied using time-dependent density functional theory (TD-DFT), which shows that the singlet and triplet levels shift due to the excited state geometry, reducing the uphill energy barrier for SF to within kT.

36 MATERIALS SCIENCE↗

Cubic crystals in an x-ray polarization-splitting geometry

Hexagonal and cubic crystals contain paired sets of internal planes that reflect the linearly polarized components of certain x rays into two separate, perpendicular directions. For the cubic crystals, two distinct crystal orientations provide the same polarization-splitting geometry. One of the orientations may have advantages for plasma spectroscopy by suppressing unwanted reflections. This paper demonstrates the two orientations with a germanium crystal and K characteristic lines from copper and zirconium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

An imaging refractometer for density fluctuation measurements in high energy density plasmas

In this work, we report on a recently developed laser-probing diagnostic which allows direct measurements of ray-deflection angles in one axis, whilst retaining imaging capabilities in the other axis. This allows us to measure the spectrum of angular deflections from a laser beam which passes though a turbulent high-energy-density plasma. This spectrum contains information about the density fluctuations within the plasma, which deflect the probing laser over a range of angles. We create synthetic diagnostics using ray-tracing to compare this new diagnostic with standard shadowgraphy and schlieren imaging approaches, which demonstrates the enhanced sensitivity of this new diagnostic over standard techniques. We present experimental data from turbulence behind a reverse shock in a plasma and demonstrate that this technique can measure angular deflections between 0.06 and 34 mrad, corresponding to a dynamic range of over 500.

47 OTHER INSTRUMENTATION↗