Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operator Theory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Conditions for stable operation of solid oxide electrolysis cells: oxygen electrode effects

Solid oxide electrolysis cells (SOECs) convert renewable electricity to fuels with efficiency substantially higher than other electrolysis technologies. However, questions remain regarding degradation mechanisms that limit SOEC long-term stability. One of the key degradation mechanisms is oxygen electrode delamination; although prior studies have improved the understanding of this mechanism, it is still difficult to predict how degradation depends on SOEC materials and operating conditions, i.e., temperature, voltage, and current density. Here we present a study aimed at developing a quantitative understanding of oxygen electrode delamination. Experimentally, a life test study of symmetric and full cells with yttria-stabilized zirconia (YSZ) electrolytes and Gd-doped ceria (GDC) barrier layers was done with three different perovskite oxygen electrode materials. Fracture was observed at the perovskite–GDC interface above a critical current density and below a critical operating temperature. A theory is presented that combines a calculation of the effective oxygen pressure across the electrolyte with an estimation of the pressure required for fracture. Fracture is correctly predicted for a critical oxygen partial pressure of ~7200 atm and an associated electrode overpotential of ~0.2 V, occurring at the electrode/GDC interface because of the relatively low perovskite fracture toughness. As a result, damage at the GDC/YSZ interface was also observed in some cases and explained by a peak in the oxygen pressure at this interface.

30 DIRECT ENERGY CONVERSION↗

Markov state models from short non-equilibrium simulations—Analysis and correction of estimation bias

To begin, many state-of-the-art methods for the thermodynamic and kinetic characterization of large and complex biomolecular systems by simulation rely on ensemble approaches, where data from large numbers of relatively short trajectories are integrated. In this context, Markov state models (MSMs) are extremely popular because they can be used to compute stationary quantities and long-time kinetics from ensembles of short simulations, provided that these short simulations are in “local equilibrium” within the MSM states. However, over the last 15 years since the inception of MSMs, it has been controversially discussed and not yet been answered how deviations from local equilibrium can be detected, whether these deviations induce a practical bias in MSM estimation, and how to correct for them. In this paper, we address these issues: We systematically analyze the estimation of MSMs from short non-equilibrium simulations, and we provide an expression for the error between unbiased transition probabilities and the expected estimate from many short simulations. We show that the unbiased MSM estimate can be obtained even from relatively short non-equilibrium simulations in the limit of long lag times and good discretization. Further, we exploit observable operator model (OOM) theory to derive an unbiased estimator for the MSM transition matrix that corrects for the effect of starting out of equilibrium, even when short lag times are used. Finally, we show how the OOM framework can be used to estimate the exact eigenvalues or relaxation time scales of the system without estimating an MSM transition matrix, which allows us to practically assess the discretization quality of the MSM. Applications to model systems and molecular dynamics simulation data of alanine dipeptide are included for illustration. The improved MSM estimator is implemented in PyEMMA of version 2.3.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development of Gibbs's dyadic and implications for the gradient of a vector field

In this paper, we review the history of the dyadic as developed by Gibbs. This mathematical construct appeared in the second part of Gibbs's pamphlet on vector analysis (published in 1884), and it represented the first known development of a Cartesian theory of tensors. Gibbs made extensive use of the dyadic to express his theory of linear vector functions, that is, functions that acted on vectors and mapped them to new vectors. The dyadic proved to be a capable vehicle in Gibbs's hands, and his theory for dyadics (which we would now call second-order Cartesian tensors) was relatively advanced. The theory detailed notions such as the decomposition of vectors and conditions under which a tensor would have an inverse. While Gibbs's theory for linear operators expressed by dyadics was robust, it did not seem to garner the attention that the more conventional vector analysis (published in the first half of his pamphlet in 1881) did. Perhaps in part because of the general unfamiliarity with the dyadic, two distinct and conflicting definitions of the gradient of a vector field have arisen in the literature. The details of these differences in notation, possible reasons for the difference, and a potential resolution are proposed.

97 MATHEMATICS AND COMPUTING↗

Aerotaxy: gas-phase epitaxy of quasi 1D nanostructures

Cost- and resource-efficient growth is necessary for many applications of semiconductor nanowires. We here present the design, operational details and theory behind Aerotaxy, a scalable alternative technology for producing quality crystalline nanowires at a remarkably high growth rate and throughput. Using size-controlled Au seed particles and organometallic precursors, Aerotaxy can produce nanowires with perfect crystallinity and controllable dimensions, and the method is suitable to meet industrial production requirements. Here, we explain why Aerotaxy is an efficient method for fabricating semiconductor nanowires and explain the technical aspects of our custom-built Aerotaxy system. Investigations using SEM (Scanning Electron Microscope), TEM (Transmission Electron Microscope)and other characterization methods are used to support the claim that Aerotaxy is indeed a scalable method capable of producing nanowires with reproducible properties. We have investigated both binary and ternary III–V semiconductor material systems like GaAs and GaAsP. In addition, common aspects of Aerotaxy nanowires deduced from experimental observations are used to validate the Aerotaxy growth model, based on a computational flow dynamics (CFD) approach. We compare the experimental results with the model behaviour to better understand Aerotaxy growth.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MO-A-BRB-00: TG191: Clinical Use of Luminescent Dosimeters

This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3) To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-A-BRB-01: TG191: Clinical Use of Luminescent Dosimeters

This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3) To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Cosmological Bootstrap: Spinning correlators from symmetries and factorization

We extend the cosmological bootstrap to correlators involving massless spinning particles, focusing on spin-1 and spin-2. In de Sitter space, these correlators are constrained both by symmetries and by locality. In particular, the de Sitter isometries become conformal symmetries on the future boundary of the spacetime, which are reflected in a set of Ward identities that the boundary correlators must satisfy. We solve these Ward identities by acting with weight-shifting operators on scalar seed solutions. Using this weight-shifting approach, we derive three- and four-point correlators of massless spin-1 and spin-2 fields with conformally coupled scalars. Four-point functions arising from tree-level exchange are singular in particular kinematic configurations, and the coefficients of these singularities satisfy certain factorization properties. We show that in many cases these factorization limits fix the structure of the correlators uniquely, without having to solve the conformal Ward identities. The additional constraint of locality for massless spinning particles manifests itself as current conservation on the boundary. We find that the four-point functions only satisfy current conservation if the s, t, and u-channels are related to each other, leading to nontrivial constraints on the couplings between the conserved currents and other operators in the theory. For spin-1 currents this implies charge conservation, while for spin-2 currents we recover the equivalence principle from a purely boundary perspective. For multiple spin-1 fields, we recover the structure of Yang--Mills theory. Finally, we apply our methods to slow-roll inflation and derive a few phenomenologically relevant scalar-tensor three-point functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulse control of superconducting cavity-based qudits with a Fock-state basis

Fock-basis-encoding qudits allow quantum gates to operate on multiple qudit levels simultaneously. This capability is advantageous for applications involving complex local gate operations, such as the digital quantum simulation of non-Abelian gauge theories. However, compiling unitary operations to native qudit gates remains a challenging task, often requiring substantial computational resources. In this work, we theoretically investigate the direct pulse control of a superconducting radio-frequency cavity coupled to an ancilla transmon for gate synthesis. We will discuss the improvements and limitations applicable to high Fock states. This work paves the way toward more efficient and robust qudit-gate synthesis.

Li, Andy C.Y. [Fermilab] (ORCID:0000000345423739)↗

Pulse control of superconducting cavity-based qudits with a Fock-state basis

Fock-basis-encoding qudits allow quantum gates to operate on multiple qudit levels simultaneously. This capability is advantageous for applications involving complex local gate operations, such as the digital quantum simulation of non-Abelian gauge theories. However, compiling unitary operations to native qudit gates remains a challenging task, often requiring substantial computational resources. In this work, we theoretically investigate the direct pulse control of a superconducting radio-frequency cavity coupled to an ancilla transmon for gate synthesis. We will discuss the improvements and limitations applicable to high Fock states. This work paves the way toward more efficient and robust qudit-gate synthesis.

Li, Andy C.Y. [Fermilab] (ORCID:0000000345423739)↗

DSIF operations

DSIF operations for testing theory of general relativity by very long baseline interferometers and for study of pulsar polarization

Source record↗

Stability conditions derived from spectral theory - Discrete systems with periodic feedback.

By use of the spectral theory of linear operators, necessary and sufficient conditions are derived for the stability of a class of discrete time feedback systems with a periodically time-varying feedback gain. These conditions involve a Nyquist plot for an equivalent time-invariant system which may be determined from the frequency response function of the system under consideration. In the special case of a scalar-input scalar-output system, these conditions may be given in a particularly simple form.

Davis, J. H.↗

Theoretical and experimental investigations of collective microwave phenomena in solids

Methods of generating microwave shear waves efficiently were studied. A new technique of mode conversion from a longitudinal wave to a shear wave was investigated and virtually 100% conversion efficiency could be obtained. Several aspects of Gunn oscillators were studied. One involved the detailed study of domains in Gunn oscillators using long samples of bulk gallium arsenide. Several new techniques were devised for measuring the properties of the domains. A fundamental theory of the efficiency of a Gunn oscillator was worked out. A computer program was devised to study the transient effect of domains passing through Gunn diodes. Some of the first planar epitaxial Gunn oscillators were made using liquid epitaxial material grown by liquid phase techniques on semi-insulating substrate. A new theory which predicted the properties of RF signals propagating in a thin film layer of GaAs was developed. The theory of the operation of a traveling wave amplifier is described.

Kino, G. S.↗

Shuttle ascent trajectory optimization with function space quasi-Newton techniques

A Space Shuttle ascent trajectory optimization problem from lift-off to orbital insertion is solved with a function space version of a quasi-Newton parameter optimization method developed by Broyden. The problem includes five parameter and one bounded-function controls, two state-variable constraints, and four terminal conditions. The bounded controls are treated directly, while the remaining constraints are adjoined to the performance index (maximum payload) with penalty functions. The problem is formulated as a four-phase variational problem (liftoff, pitch-over, gravity-turn, linear tangent steering), and the appropriate gradients are developed by first variation theory. A projection operator is introduced to aid in the interpretation of the algorithm with mixed parameter and function controls.

Edge, E. R.↗

Fabrication and evaluation of polymeric early-warning fire-alarm devices

The electrical resistivities were investigated of some polymers known to be enhanced by the presence of certain gases. This was done to make a device capable of providing early warning to fire through its response with the gases produced in the early phases of combustion. Eight polymers were investigated: poly(phenyl acetylene), poly(p-aminophenyl acetylene), poly(p-nitrophenyl acetylene), poly(p-formamidophenyl acetylene), poly(ethynyl ferrocene), poly(ethynyl carborane), poly(ethynyl pyridine), and the polymer made from 1,2,3,6 tetramethyl pyridazine. A total of 40 usable thin-film sandwich devices and a total of 70 usable interdigitated-electrode lock-and-key devices were fabricated. The sandwich devices were used for measurements of contact linearity, polymer conductivity, and polymer dielectric constant. The lock-and-key devices were used to determine the response of the polymers to a spectrum of gases that included ammonia, carbon nonoxide, carbon dioxide, sulfur dioxide, ethylene, acrolein, water vapor, and normal laboratory air. Strongest responses were to water vapor, ammonia, and acrolein, and depending on the polymer, weaker responses to carbon dioxide, sulfur dioxide, and carbon monoxide were observed. A quantitative theory of device operation, capable of accounting for observed device leakage current and sensitivity, was developed. A prototype detection/alarm system was designed and built for use in demonstrating sensor performance.

Senturia, S. D.↗

AAFE RADSCAT data reduction programs user's guide

Theory, design and operation of the computer programs which automate the reduction of joint radiometer and scatterometer observations are presented. The programs reduce scatterometer measurements to the normalized scattering coefficient; whereas the radiometer measurements are converted into antenna temperatures. The programs are both investigator and user oriented. Supplementary parameters are provided to aid in the interpretation of the observations. A hierarchy of diagnostics is available to evaluate the operation of the instrument, the conduct of the experiments and the quality of the records. General descriptions of the programs and their data products are also presented. This document therefore serves as a user's guide to the programs and is therefore intended to serve both the experimenter and the program operator.

Claassen, J. P.↗

The human controller in car following

The man machine interface between the human driver and his automobile during car following tasks was examined. A direct connection between models of the human operator and the theory of optimal control was established for car following situations involving both linear and nonlinear car dynamics. Results obtained from several types of mathematical models are discussed. Conventional parameter identification techniques were used to obtain the parameters of these models by comparing their performance to data obtained by aerial photogrammetry. The results indicate that there are two general classes of model structures: models assumed to have preview information and models without preview.

Burnham, G. O.↗