Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A review of reduced Kalman filters for clock ensembles

This paper reviews the author’s previous work on free-running timescales based on Kalman filters that act upon clock comparisons. The natural Kalman clock ensemble algorithm tends to optimize long-term timescale stability at the expense of short-term stability. By subjecting each postmeasurement error covariance matrix to a non-transparent reduction operation, one obtains corrected clocks with improved short-term stability and little sacrifice of long-term stability. A new result on covariance matrix reduction is also stated.

Greenhall, Charles A.↗

A simple, low cost application of a flight test parameter identification system

The flight test system combines state-of-the-art microprocessor technology and high accuracy instrumentation with parameter identification technology which minimize data and flight time requirements. The system was designed to avoid permanent modifications of the test airplane and allow quick installation. It is capable of longitudinal and lateral-directional stability and control derivative estimation. This paper presents details of this system, calibration and flight test procedures, and the results of the Cessna 172 flight test program. The system has proven easy to install, simple to operate, and capable of accurate estimation of stability and control parameters in the Cessna 172 flight tests.

Clarke, R.↗

The Theory of Pulsating Flow in Conical Nozzles

A knowledge of the dynamic characteristics of nozzles and orifices is important in many control and stability analyses of engineering devices. It is usual to assume that the instantaneous flow-rate, for a given set of inlet conditions and outlet pressure, is the same as the nontransient value for the same operating conditions. Recently, in connection with the stability analysis of an externally pressurized thrust bearing, the validity of this assumption was questioned. The analysis presented in this paper was undertaken to provide an answer. The present analysis applies to any fluid, liquid, or gas flowing into a simple conical nozzle. The amplitude and phase of the mass-flux response to a sinusoidally time-varying pressure fluctuation at the nozzle exit are determined. An approximate formula is given for these quantities in terms of the nozzle throat area, the solid angle subtended by the cone, the velocity of the fluid at the nozzle throat, the acoustic velocity at the throat, and the frequency of the pressure fluctuation.

Elrod, H. G., Jr.↗

Flow Range of Centrifugal Compressor Being Extended

General Aviation will benefit from turbine engines that are both fuel-efficient and reliable. Current engines fall short of their potential to achieve these attributes. The reason is compressor surge, which is a flow stability problem that develops when the compressor is subjected to conditions that are outside of its operating range. Compressor surge can occur when fuel flow to the engine is increased, temporarily back pressuring the compressor and pushing it past its stability limit, or when the compressor is subjected to inlet flow-field distortions that may occur during takeoff and landing. Compressor surge can result in the loss of an aircraft. As a result, engine designers include a margin of safety between the operating line of the engine and the stability limit line of the compressor. Unfortunately, the most efficient operating line for the compressor is usually closer to its stability limit line than it is to the line that provides an adequate margin of safety. A wider stable flow range will permit operation along the most efficient operating line of the compressor, improving the specific fuel consumption of the engine and reducing emissions. The NASA Glenn Research Center is working to extend the stable flow range of the compressor. Significant extension has been achieved in axial compressors by injecting air upstream of the compressor blade rows. Recently, the technique was successfully applied to a 4:1 pressure ratio centrifugal compressor by injecting streams of air into the diffuser. Both steady and controlled unsteady injection were used to inject air through the diffuser shroud surface and extend the range. Future work will evaluate the effect of air injection through the diffuser hub surface and diffuser vanes with the goal of maximizing the range extension while minimizing the amount of injected air that is required.

Skoch, Gary J.↗

Control system design for the large space systems technology reference platform

Structural models and classical frequency domain control system designs were developed for the large space systems technology (LSST) reference platform which consists of a central bus structure, solar panels, and platform arms on which a variety of experiments may be mounted. It is shown that operation of multiple independently articulated payloads on a single platform presents major problems when subarc second pointing stability is required. Experiment compatibility will be an important operational consideration for systems of this type.

Edmunds, R. S.↗

Communicating through deep space

NASA's Deep Space Network (DSN) consists of a worldwide set of communication stations and a central control facility in California, enabling communication with spacecraft thousands of millions of miles from earth. The stations have gone from 26 m diameter antennas operating at 960 MHz to 70 m diameter (by 1988) at 8400 MHz. The DSN provides exceptional performance in high gain steerable antennas, ultra-low noise receivers, high power transmitters, frequency and time standards, and precise radio metric data. Spacecraft missions envisaged in the 1990's for the continuing exploration of the Solar System include an array of increasingly complex visits to the inner planets, asteroids and comets and the outer planets. The Deep Space Network planned for the mid-1980s may not meet all the needs of these missions without substantial change. Deep space stations may require conversion to operation with beam waveguides, higher frequency and relative frequency stability of 10 to the -16th. A deep space relay station in earth orbit could permit operation at higher frequencies, with attendant higher performance. Long range planning to select the appropriate future network configurations and develop the technologies essential to their implementation is underway.

Smith, J. G.↗

Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications

The design and initial demonstration of a laser pump module (LPM) incorporating single-mode, grating-stabilized 808-nm diode lasers and a low-loss, high-port-count optical combiner are completed. The purpose of the developed LPM is to reliably pump an Nd:YAG crystal in the laser head (LH), which serves as the optical metrology source for SIMLite mission. Using the narrow-linewidth, single-mode laser diodes enables placement of the pump power near Nd adsorption peak, which enhances pumping efficiency. Grating stabilization allows for stable pump spectra as diode operating temperature and bias current change. The low-loss, high-port-count optical combiner enables efficient combining of tens of pumps. Overall, the module supports 5+ years of continuous operation at 2 W of pump power with reliability approaching 100 percent. The LPM consists of a laser diode farm (LDF) and a pump beam combiner (PBC). An array of 807- to 808-nm fiber-pigtailed laser diodes makes up the LDF. A Bragg grating in each 5- m core single-mode (SM) fiber pigtail acts to stabilize the lasing spectra over a range of diode operating conditions. These commercially available single-mode laser diodes can deliver up to 150 mW of optical power. The outputs from the multiple pumps in the LDF are routed to the PBC, which is a 37-input by 1-output all-fiber device. The input ports consist of 5- m core SM fiber, while the output port consists of 105- m core, 0.15 NA (numerical aperture) multi-mode (MM) fiber. The combiner is fabricated by fusing the 37 input fibers while simultaneously tapering the fused region. At the completion of this process, the MM fiber is spliced to the end of the adiabatic taper, and, for protection, the combiner is sheathed by a capillary tube. A compact and robust metal housing was designed and fabricated to protect the PBC during space deployment.

Erlig, Herman↗

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of tuning capacitors on the power factor and power output of a gas spring-based free-piston Stirling convertor—Advanced Stirling convertor—when the convertor runs on a forced-oscillation type controller. More specifically, this paper studies how off-nominal tuning capacitance values affects the Stirling convertor in terms of the piston stability and electrical power output, when the convertor is operated by forced-oscillation type controller, such as an alternating current bus controller, and operating conditions of the convertor are unchanged. It has been widely known that tuning capacitors are important circuit components to stabilize the piston amplitude of the free-piston Stirling convertors and correct the power factor for high electrical power output. Recent modeling analysis conducted by NASA Glenn Research Center, however, suggests that while the stability of the convertor is affected by the tuning capacitor value, the power factor and the electrical power output are not affected by the tuning capacitor value, as long as the convertor is controlled by a forced-oscillation controller and the convertor operating conditions, such as the hot-end/cold-end temperatures, piston amplitude, and operating frequency, are unchanged. To verify the modeling analysis results, a test setup is devised where the convertor is controlled by a forced-oscillation controller and the piston amplitude, hot-end temperature, and charge pressure are controlled to 4mm, 760˚C, and 485psig, respectively, while the tuning capacitor value is changed from its nominal value, 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the same convertor with the three tuning capacitor values are also presented in this paper to show the effect of the tuning capacitor value on the convertor stability. The test results suggest that when the convertor is controlled by a forced-oscillation, the tuning capacitor value determines the convertor stability but not the power factor nor electrical power output. Therefore, the tuning capacitance value in forced-oscillation controllers should be determined based on the convertor stability, system mass, and volume.

Free-Piston Stirling Convertor Controller↗

Stability and performance tradeoffs in bi-lateral telemanipulation

Kinesthetic force feedback provides measurable increase in remote manipulation system performance. Intensive computation time requirements or operation under conditions of time delay can cause serious stability problems in control-system design. Here, a simplified linear analysis of this stability problem is presented for the forward-flow generalized architecture, applying the hybrid two-port representation to express the loop gain of the traditional master-slave architecture, which can be subjected to similar analysis. The hybrid two-port representation is also used to express the effects on the fidelity of manipulation or feel of one design approach used to stabilize the forward-flow architecture. The results suggest that, when local force feedback at the slave side is used to reduce manipulator stability problems, a price is paid in terms of telemanipulation fidelity.

Hannaford, Blake↗

Stability and 3-D spatial dynamics analysis of a three cable crane

A 3-cable crane mechanism has been designed for incorporation into a highly loaded Lunar crane for planetary construction. This 3-cable crane must maintain a positive stability margin in all phases of the loading/unloading, assembly, or installation operations. A 2D kinematic curvature theory is applied to: (1) derive a general stability criterion to prevent the 3-cable crane from instability; and (2) determine a simple equation of natural frequency for two planar models of 3-cable crane. Investigation of the 2D vibrational characteristics of the planar models provides valuable insight toward understanding of 3D dynamic behavior of the 3-cable crane. Also, precision in natural frequency from this simple kinematic equation due to the exclusion of the radius-of-gyration of a suspended article is discussed. Multibody dynamics of the 3D 3-cable crane is presented and simulated to study the resulting vibrational characteristics under external disturbances and to verify the feasibility of the stability criterion for the 3-cable crane.

Yang, Li-Farn↗

Finite element computation of compressible flows with the SUPG formulation

Finite element computation of compressible Euler equations is presented in the context of the streamline-upwind/Petrov-Galerkin (SUPG) formulation. The SUPG formulation, which is based on adding stabilizing terms to the Galerkin formulation, is further supplemented with a shock capturing operator which addresses the difficulty in maintaining a satisfactory solution near discontinuities in the solution field. The shock capturing operator, which has been derived from work done in entropy variables for a similar operator, is shown to lead to an appropriate level of additional stabilization near shocks, without resulting in excessive numerical diffusion. An implicit treatment of the impermeable wall boundary condition is also presented. This treatment of the no-penetration condition offers increased stability for large Courant numbers, and accelerated convergence of the computations for both implicit and explicit applications. Several examples are presented to demonstrate the ability of this method to solve the equations governing compressible fluid flow.

Le Beau, G. J.↗

Flight Test Results for the NICMOS Cryocooler

In October 1998 a mechanical cryocooler and cryogenic circulator loop were flown on NASA's STS-95 as part of the Hubble Orbital System Test (HOST). The system will be installed on the Hubble Space Telescope (HST) during Service Mission #3 in 2000 and will provide cooling to the Near Infrared Camera and Multi-Object Spectrometer (NICMOS). It will extend the useful life of that instrument by 5 to 10 years. This was the first successful space demonstration of a turbobrayton cryocooler. The cooler is a single stage reverse Brayton type, using low-vibration high-speed miniature turbomachines for the compression and expansion functions. A miniature centrifugal cryogenic circulator is used to deliver refrigerated neon to the instrument. During the mission, the cooler operated without anomalies for approximately 185 hours over a range of conditions to verify its mechanical, thermodynamic and control functions. The cryocooler satisfied all mission objectives including maximum cooldown to near-design operating conditions, warm and cold starts and stops, operation at near-design temperatures, and demonstration of long-term temperature stability. This paper presents a description of the cooler and its operation during the HOST flight.

Dolan, F. X.↗

Dynamic Modeling of Off-Nominal Operation in Advanced Life Support Systems

System failures, off-nominal operation, or unexpected interruptions in processing capability can cause unanticipated instabilities in Advanced Life Support (ALS) systems, even long after they are repaired. Much current modeling assumes ALS systems are static and linear, but ALS systems are actually dynamic and nonlinear, especially when failures and off nominal operation are considered. Modeling and simulation provide a way to study the stability and time behavior of nonlinear dynamic ALS systems under changed system configurations or operational scenarios. The dynamic behavior of a nonlinear system can be fully explored only by computer simulation over the full range of inputs and initial conditions. Previous simulations of BIO-Plex in SIMULINK, a toolbox of Matlab, were extended to model the off-nominal operation and long-term dynamics of partially closed physical/chemical and bioregenerative life support systems. System nonlinearity has many interesting potential consequences. Different equilibrium points may be reached for different initial conditions. The system stability can depend on the exact system inputs and initial conditions. The system may oscillate or even in rare cases behave chaotically. Temporary internal hardware failures or external perturbations in ALS systems can lead to dynamic instability and total ALS system failure. Appropriate control techniques can restore reliable operation and minimize the effects of dynamic instabilities due to anomalies or perturbations in a life support system.

Jones, Harry↗

Cardiovascular telemetry implants

Cardiovascular telemetry total implants, describing measurement problems, equipment design, low current operation, size and thermal and temporal stability

Rader, R. D.↗