At least 469 records · Page 26

Integrity Enhancing Protocols: Performance and Recommendations for Nuclear Systems

In today’s communication landscape there are multiple technologies and protocols used for communication between end devices. Within security paradigms for these protocols, integrity management is a common goal of system designers. Communication protocols focused on maintaining message integrity can provide assurance that some received data has not been altered or tampered with. While integrity is often coupled with confidentiality in protocol design, this analysis focuses on an evaluation of only integrity protocols. This report outlines various ways message integrity may be preserved with respect to high performance operational technology (OT) systems. It describes a series of experiments and an evaluation framework used to evaluate the performance of the identified integrity approaches regarding common system design goals. Finally, it addresses the testing environment utilized and closes the report with a summary of experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

Electric Grid and Markets 101 [Slides]

This presentation covers aspects of operating the bulk power system with a focus on the regulatory levels of the US grid at a pretty introductory level. It was meant ot help inform a request from USDA for a "101" presentation that spoke to how electricity markets, contracting and regulation interact with the engineering and physics of operating the bulk power system. They are presently moving to being able to more directly fund PPAs or other non-co-op owned assets for member co-ops, is my understanding.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Essence2.0 Development and Deployment (Final Report)

The objective of the project was to take two core technologies that have been developed under the Recipient’s solid laboratory products and integrate them into a single CyberPhysical awareness platform and complete development on current field-tested prototypes that will extend the integrated capability of the platform. During the final development phase, the Recipient development team and its selected industry partners tested and hardened the platform to ensure resilient and secure operation of the integrated platform. The team also executed substantial field testing and established the framework for defining the organization and/or commercial infrastructure needed to sustain operations and provide readiness for a national scale deployment. The focus of the project was (1) the improvement, refinement, and deployment of technology for the detection of cyber-attacks on utility operational technology (OT) and information technology (IT) networks and assets, including Supervisory Control and Data Acquisition Systems (SCADA) systems; and (2) support for containment and remediation of adversarial threats and actions against those systems and environments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reactor System Facility Modification to Detect Compromised Human Machine Interfaces

This study focuses on a multi-layered Industrial Control System (ICS)/Operational Technology (OT) security architecture to aid in the discovery and mitigation of compromised Human Machine Interface (HMI)/Instrumentation & Control (I&C) based systems for modifying a prototypical reactor condition test facility called the Flowing Autoclave System (FAS) at Idaho National Laboratory (INL). This is achieved through a three-layered combination of network security solutions, hash-based algorithms, and blockchain technologies. Hash algorithms are mathematical functions used to generate a predetermined set of fixed-length values. They are widely used in computer security to verify the integrity of system information and data, both on a local network and the wider internet. Even small amounts of unauthorized system modification will cause the hash algorithm to output a set of characters that deviate significantly from its original value. Assisting secure hash functions, blockchain technology is a secure and distributed technology used to provide an immutable set of records replicated on all devices within a decentralized network. Blockchain offers a cost-effective solution to detect system compromise by providing a traceable breadcrumb trail of all network activity and data modification happening on a system. If both are used in conjunction with network monitoring tools, the integration of this three-pronged approach can become an asset in detecting suspected system compromises before any real damage can occur.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bayesian Attack Model (BAM) User Story

This document presents a user story for the Bayesian Attack Model (BAM) tool designed to aggregate and analyze cyber-attack observables for operational technology (OT) systems. BAM aims to empower cybersecurity analysts by providing a streamlined interface for collecting observable data from various sources, enabling real-time analysis of potential adversary activity. By enhancing the response capabilities of security teams, BAM facilitates risk-informed decision-making and improves organizational security posture. This user story outlines the key functionalities, user interactions, and requirements necessary to successfully integrate BAM with other security information and event management (SIEM) technology and cybersecurity operations centers (CSOCs).

97 MATHEMATICS AND COMPUTING↗

Cyber-Physical Tabletop Exercise for Small Modular Reactor Facilities

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. This evolving threat landscape includes adversaries having offensive cyber capabilities to attack information technology (IT) systems and operation technology (OT) systems. These adversaries may have the ability to attack the physical protection system (PPS) networks with potential consequential impacts that could degrade the effectiveness of the PPS. These cyber attacks may also be used to attack the safety and operational systems used to operate and ensure the safety of the reactor. Additionally, adversaries may gain access to unmanned aerial systems (UAS) that may be used to provide reconnaissance and surveillance of the facility, provide information to the adversaries, and be equipped with kinetic capabilities such as explosives or weapons that can be used to directly attack the facility. The Department of Energy’s Office of Nuclear Energy’s Advanced Reactor Safeguards and Security (ARSS) program funded Sandia National Laboratories (SNL) and Idaho National Laboratory (INL) to develop a cyber-physical tabletop exercise (TTX). This exercise was conducted on a hypothetical small modular reactor (SMR) facility, and only considered a potential adversary cyber attack on the PPS to a physical attack on the hypothetical facility to achieve a radiological release. This cyber-physical TTX is meant to provide lessons learned to integrate the cyber security system design and the physical protection system (PPS) design to decrease design, operation, and maintenance costs as well as increase effectiveness for defending against design basis threat attacks at the facility. This TTX will also provide a framework and method for SMR and microreactor vendors to conduct their own cyber-physical TTX and gain impactful insights to improving the cyber and physical protection system design for their SMR or microreactor facility design.

42 ENGINEERING↗

5G integrated edge computing platform for efficient component monitoring in coal-fired power plants

This project developed a cutting-edge 5G-integrated edge computing framework to enhance operational efficiency and reliability in coal-fired power plants through real-time component monitoring and anomaly detection. The initiative focused on leveraging distributed machine learning, federated learning, and 5G-based dynamic network slicing to support scalable, fault-tolerant monitoring environments to meet the operational requirements in industrial control systems. With a Distributed Edge Computing Service (DECS) orchestration, this project enabled federated learning at edge for condition monitoring and introduced adaptive client selection strategies to minimize communication overhead. Scalable distributed training was achieved using the Horovod framework, thus enhancing performance across edge nodes. In the realm of 5G networking, the project designed and deployed reconfigurable, QoS-aware network slicing tailored for operational technology (OT) environments, integrating software-defined networks to bolster cyber-resilience and enabling dynamic slicing for federated learning workloads. A significant milestone was the development of a virtualized ICS environment with 5G core integration—which allowed elastic and fault tolerant distributed training on real-world datasets such as NASA Bearings, Hydraulic Systems, and TEP. To broaden the impact of the project, a TRL-3 virtualized ICS testbed for research and education was designed. This project engaged several graduate and undergraduate students to conduct research on the cutting-edge technology, and it resulted in one PhD dissertation, one MS thesis, and over 14 peer-reviewed publications. With the support of this project students also participated in national cybersecurity competitions to improve their professional development skills.

20 FOSSIL-FUELED POWER PLANTS↗

User Guide to the Facility Cybersecurity Capability Maturity Model (F-C2M2) Assessment

The Facility Cybersecurity Capability Maturity Model (F-C2M2) assessment was designed to help facilities address their unique cybersecurity challenges. Building upon the foundational principles of the U.S. Department of Energy (DOE) Cybersecurity Capability Maturity Model (C2M2), the F-C2M2 was explicitly tailored for federal facilities to help evaluate, benchmark, and enhance the cybersecurity capabilities of both their information technology (IT) and operational technology (OT) environments. This user guide was developed to facilitate a thorough understanding of the tool. Whether users are familiar with the original C2M2 or are new to the maturity model concept, this guide was designed to offer clarity, direction, and support.

97 MATHEMATICS AND COMPUTING↗

Land-Based Wind Reference Architecture

This report describes a summary and the final deliverables for the Wind Reference Architecture project funded by the Department of Energy's (DOE) Wind Energy Technology Office (WETO). The project objective was to further refine the reference architecture of the existing wind power plant reference architecture developed by Idaho National Laboratory (INL) and Sandia National Laboratories (SNL) by expanding the wind turbine generator (WTG) into a separate individual wind turbine reference architecture. Additional details regarding the wind turbine system and how it integrates with a wind power plant were researched and reflected in the reference architecture. This addition is important because it allows researchers to understand the components and devices in a wind turbine, how they function and how a wind turbine integrates into a wind power plant to be able to perform cybersecurity evaluations on the system. The communication and control systems were the focus while developing this reference architecture to understand the cybersecurity posture of a wind turbine and power plant. The information technology (IT) and operational technology (OT) systems perspective are integral in helping improve the cybersecurity posture by creating a starting point to study how wind energy can be safely designed and deployed in our power grid from an integrated systems standpoint. A holistic wind power plant and turbine reference architecture and simulation was developed and made open-sourced for further research efforts.

17 WIND ENERGY↗

Secure and Resilient Operations Using Open-Source Distributed Systems Platform (OpenDSP)

The goal of this project is to identify and address cybersecurity gaps by developing a multi-layer multi-channel cyber-physical defense and survival mechanism for operating distribution networks with high penetration of solar / inverter-based resource (IBR) / distributed energy resource (DER). The proposed security enhancements are built upon the distributed framework and solution architecture for both information technology (IT) and operational technology (OT) systems. The technical solutions consist of two composite functionalities and six layers: proactive defense (vulnerability assessment, communication protection, and attack detection, as layers 1-3), and adaptive self-healing (attack-resilient control, adaptive recovery, and resilient survival, as layers 4-6). These layers, built on and extended from DHS CISA Cyber Framework, establish an integrated and robust cybersecurity framework for operating large-scale distribution networks.

14 SOLAR ENERGY↗

Advancing Artificial Intelligence with Liquid Argon Neutrino Experiments (Technical Report)

The grant allowed two main contributions: 1) The development of a first successful demonstration of the employment of Optimal Transport in liquid argon time projection chamber neutrino detectors. Optimal Transport, used in other contexts and specifically with LHC calorimetric data, was adapted to address a key particle identification challenge in LArTPCs: the separation of pi0 backgrounds from single-electrons produced in charged-current electron neutrino interactions. The work, leveraging ML methods such as k-nearest-neighbor (kNN) and support-vector-machine (SVM), showed an increase in background rejection of a factor of two or more. Work is now ongoing to incorporate this development in physics analyses for LArTPC experiments and more broadly expand the use of OT in LArTPC detectors including DUNE. This work was done in collaboration with the phenomenology group led by Nathaniel Craig at UCSB. 2) The deployment of NuGraph2, a graph neural network developed for LArTPC reconstruction, in the MicroBooNE experiment. NuGraph2 uses novel graph-neural-network methods on the rather simple LArTPC inputs of reconstructed hits, greatly simplifying the workflow compared to the use of waveform or signal-deconvolved wire ROIs. The network performed particle classification and was shown to address many challenging problems in LArTPC imaging including track-shower separation and the identification of protons and charged pions from primary muons. Our group collaborated with Giuseppe Cerati (FNAL scientist) who is one of the core developers of NuGraph2 to integrate this tool in MicroBooNE’s analysis framework. This consisted in tow key contributions: a) Studying performance on real data, which came with several months of iterations because the MC-trained version of the network was found to show significant bias that our group investigated and addressed. b) Integrating the output hit labeling of NuGraph2 into the existing particle tracking and shower reconstruction code. As a result of this work led by our team NuGraph2 is now enabling a suite of new analyses which benefit from enhanced capabilities and thus broader physics reach. The grant supported primarily the salary of UCSB graduate student Chuyue “Michaelia” Fang as well as partial summer salary support for PI Caratelli. Some funds were used for travel by Michaelia to ML related schools and conferences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Software Design Document for the AMP Nuclear Fuel Performance Code

The purpose of this document is to describe the design of the AMP nuclear fuel performance code. It provides an overview of the decomposition into separable components, an overview of what those components will do, and the strategic basis for the design. The primary components of a computational physics code include a user interface, physics packages, material properties, mathematics solvers, and computational infrastructure. Some capability from established off-the-shelf (OTS) packages will be leveraged in the development of AMP, but the primary physics components will be entirely new. The material properties required by these physics operators include many highly non-linear properties, which will be replicated from FRAPCON and LIFE where applicable, as well as some computationally-intensive operations, such as gap conductance, which depends upon the plenum pressure. Because there is extensive capability in off-the-shelf leadership class computational solvers, AMP will leverage the Trilinos, PETSc, and SUNDIALS packages. The computational infrastructure includes a build system, mesh database, and other building blocks of a computational physics package. The user interface will be developed through a collaborative effort with the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Capability Transfer program element as much as possible and will be discussed in detail in a future document.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of Electric Vehicle Charger Cybersecurity Vulnerabilities, Potential Impacts, and Defenses

Worldwide growth in electric vehicle use is prompting new installations of private and public electric vehicle supply equipment (EVSE). EVSE devices support the electrification of the transportation industry but also represent a linchpin for power systems and transportation infrastructures. Cybersecurity researchers have recently identified several vulnerabilities that exist in EVSE devices, communications to electric vehicles (EVs), and upstream services, such as EVSE vendor cloud services, third party systems, and grid operators. The potential impact of attacks on these systems stretches from localized, relatively minor effects to long-term national disruptions. Fortunately, there is a strong and expanding collection of information technology (IT) and operational technology (OT) cybersecurity best practices that may be applied to the EVSE environment to secure this equipment. In this paper, we survey publicly disclosed EVSE vulnerabilities, the impact of EV charger cyberattacks, and proposed security protections for EV charging technologies.

33 ADVANCED PROPULSION SYSTEMS↗

Molecular Dynamics Simulation and Cryo-Electron Microscopy Investigation of AOT Surfactant Structure at the Hydrated Mica Surface

Structural properties of the anionic surfactant dioctyl sodium sulfosuccinate (AOT or Aerosol-OT) adsorbed on the mica surface were investigated by molecular dynamics simulation, including the effect of surface loading in the presence of monovalent and divalent cations. The simulations confirmed recent neutron reflectivity experiments that revealed the binding of anionic surfactant to the negatively charged surface via adsorbed cations. At low loading, cylindrical micelles formed on the surface, with sulfate head groups bound to the surface by water molecules or adsorbed cations. Cation bridging was observed in the presence of weakly hydrating monovalent cations, while sulfate groups interacted with strongly hydrating divalent cations through water bridges. The adsorbed micelle structure was confirmed experimentally with cryogenic electronic microscopy, which revealed micelles approximately 2 nm in diameter at the basal surface. At higher AOT loading, the simulations reveal adsorbed bilayers with similar surface binding mechanisms. Adsorbed micelles were slightly thicker (2.2–3.0 nm) than the corresponding bilayers (2.0–2.4 nm). Upon heating the low loading systems from 300 K to 350 K, the adsorbed micelles transformed to a more planar configuration resembling bilayers. The driving force for this transition is an increase in the number of sulfate head groups interacting directly with adsorbed cations.

58 GEOSCIENCES↗

leblanc-lab/EnergyFlow.jl

A julia-based OT solver for high-energy particle physics, inspired by the EnergyFlow package.

LeBlanc, Matt [Brown Univ., Providence, RI (United↗

Building Nuclear-Specific Cybersecurity Expertise in Higher Education

The rapid digitalization of nuclear power plants (NPPs) and the deployment of advanced and small modular reactors (A/SMRs) have expanded the cybersecurity attack surface within the nuclear sector. This evolution introduces unique challenges beyond those faced in general information technology (IT), operational technology (OT) and industrial control system (ICS) security, due to nuclear power’s regulatory rigor, safety-critical nature, and operational needs. A pressing workforce gap persists; cybersecurity graduates typically lack nuclear-specific context and retraining them for industry readiness requires 12–18 months, creating a significant burden. This paper addresses this gap by defining the domains of knowledge that nuclear cybersecurity specialists must master, spanning cybersecurity, nuclear engineering, OT/ICS security, and regulatory governance. We propose a curricular framework integrating technical, regulatory, and applied learning components to accelerate workforce readiness. Our approach builds on existing findings that current curricula inadequately integrate nuclear engineering and cybersecurity, shifting the discourse from why specialization is needed to what knowledge must be taught. The recommendations have implications for workforce development and long-term resilience of the nuclear energy sector.

99 - GENERAL AND MISCELLANEOUS↗