Note: Simultaneous measurement of transverse speed and axial velocity from a single optical beam

A method is introduced for simultaneously measuring transverse speed and axial velocity using a single optical beam and a standard photon Doppler velocimetry (PDV) sensing architecture. This result is of particular interest given the recent, widespread use of PDV and the fact that optical velocimetry has thus far been limited to measuring motion in one dimension per probe. Further, this result demonstrates that both axial velocity data and transverse speed data (at least qualitative) may be obtained entirely through signal analysis; not requiring hardware modification. This result is immediately relevant to analyses of existing PDV data and to future efforts in high-speed optical velocimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Simple calibration of the counting-rate dependence of the timing shift of single photon avalanche diodes by photon interval analysis

The counting-rate dependence of the temporal response of single photon avalanche diodes (SPADs) is a critical issue for the accurate determination of the fluorescence lifetime. In this study, the response of SPADs was examined with analyzing the time interval of the detected photons. The results clearly show that the shift of the detection timing causes the counting-rate dependence of the temporal response, and this timing shift is solely determined by the time interval from the preceding photon. We demonstrate that this timing instability is readily calibrated by utilizing the macrotime data taken with the time-tag mode that is implemented in the time-correlated single photon counting modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A real-time beam current density meter

We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Operation of gamma-ray microcalorimeters at elevated count rates using filters with constraints

Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operation at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Neutron shutter for Kolkata superconducting cyclotron

In particle accelerator facilities, experimental areas are isolated from active accelerator area with thick concrete walls. A neutron shutter is used to isolate the experimental areas from the active accelerator area in the beam line. These shutters are provided primarily to reduce the secondary radiations like neutrons in the experimental areas to permissible limit when the primary beam is blocked in the accelerator area. The reduced radiation level in the experimental areas makes the experimental areas accessible. The shutters should allow the primary beam to pass to the experimental caves when they retracted from the beam line. A new neutron shutter has been designed and fabricated. This shutter incorporates compact features with considerable reduction in length, surface area and volume. The attenuation of secondary radiations is evaluated using Monte-Carlo radiation transport code FLUKA. It is found that the features of the shutter are sufficiently good enough to reduce the diffused secondary radiations well within the permissible levels.

43 PARTICLE ACCELERATORS↗

Note: Readout of a micromechanical magnetometer for the ITER fusion reactor

We present readout instrumentation for a MEMS magnetometer, placed 30 m away from the MEMS element. This is particularly useful when sensing is performed in high-radiation environment, where the semiconductors in the readout cannot survive. High bandwidth transimpedance amplifiers are used to cancel the cable capacitances of several nanofarads. A frequency doubling readout scheme is used for crosstalk elimination. Signal-to-noise ratio in the range of 60 dB was achieved and with sub-percent nonlinearity. The presented instrument is intended for the steady-state magnetic field measurements in the ITER fusion reactor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Recombination of H{sup +} and OH{sup -} ions along water wires

Transport and recombination of hydrogen and hydroxide ions along a hydrogen-bonded water wire are studied by molecular dynamics simulation using a dissociating model for water. The results are compared with a recent CP-MD study of neutralization in bulk water [A. Hassanali, M. K. Prakrash, H. Eshet, and M. Parrinello, Proc. Natl. Acad. Sci. U.S.A. 108, 20410 (2011)]. The translocation of H{sup +} and OH{sup -} along the wire is faster than in the bulk water, followed by compression of the water wire when two water molecules separate the transported ions. Neutralization occurs with the concerted transfer of three protons as in the bulk water, followed by energy dissipation along the water chain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Synchronous energy extraction through four output ports of microwave compressor

The energy stored in a resonant cavity was extracted through four output ports and added in phase in a common line. Operation of a single switch provided synchronism and the power portions transmitted through the ports were combined in a waveguide turnstile junction. Estimation shows that the compressor peak power can reach a value eight times as much as the switched wave power, provided the output pulsewidth is shortened by the same factor with reference to the cavity double transit time. The performance of the X-band compressor prototype was investigated. Signals radiated through each of four output ports had identical envelope shapes and equal peak power values. The reflected wave did not accompany the power combining. The pulses of 1.2 MW peak power and 1.6 ns pulse width were obtained when the compressor was driven by the 50 kW pulse power magnetron generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A novel dual-channel time-of-flight mass spectrometer for photoelectron imaging spectroscopy

A novel dual-channel time-of-flight mass spectrometer (D-TOFMS) has been designed to select anions in the photoelectron imaging measurements. In this instrument, the radiation laser can be triggered precisely to overlap with the selected ion cloud at the first-order space focusing plane. Compared with that of the conventional single channel TOFMS, the in situ mass selection performance of D-TOFMS is significantly improved. Preliminary experiment results are presented for the mass-selected photodetachment spectrum of F{sup -} to demonstrate the capability of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Matching index technique for avoiding higher order mode resonance in accelerators: INDUS-2 accelerator as a case study

Resonance between circulating beam frequencies and RF cavity Higher Order Modes (HOMs) of accelerators can lead to coupled-bunch instabilities. Shifting these HOMs to avoid the resonance is a topic of active interest. A study has been carried out for the accelerating cavities of the INDUS-2. For quantitative measure of deciding which modes have to be moved and by how much, we introduce a new index called the matching index (I{sub M}), as a measure of how close a HOM is to the nearest beam mode. Depending on the value of I{sub M}, the operating scenarios are classified as safe and unsafe.

43 PARTICLE ACCELERATORS↗

Note: Absolute photoionization cross-section of the vinyl radical

This work measures the absolute photoionization cross-section of the vinyl radical (σvinyl(E)) between 8.1 and 11.0 eV. Two different methods were used to obtain absolute cross-section measurements: 193 nm photodissociation of methyl vinyl ketone (MVK) and 248 nm photodissociation of vinyl iodide (VI). The values of the photoionization cross-section for the vinyl radical using MVK, σvinyl(10.224 eV) = (6.1 ± 1.4) Mb and σvinyl(10.424 eV) = (8.3 ± 1.9) Mb, and using VI, σvinyl(10.013 eV) = (4.7 ± 1.1) Mb, σvinyl(10.513 eV) = (9.0 ± 2.1) Mb, and σvinyl(10.813 eV) = (12.1 ± 2.9) Mb, define a photoionization cross-section that is ~1.7 times smaller than a previous determination of this value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Note: Spectral motional Stark effect diagnostic for measurement of magnetic fields below 0.3 T

The paper reports on development of the spectral motional Stark effect (MSE) diagnostic in the midplane of the gas dynamic trap (GDT) linear system for magnetic confinement of anisotropic hot-ion plasma. The axially symmetric GDT vacuum magnetic field has a minimum value in the midplane, which varies from 0.2 to 0.35 T in different regimes of operation. Buildup of 15 keV ion population generates a diamagnetic reduction of magnetic field in the plasma core of up to 30% in the maximum density region, as measured by the existing eight-line MSE diagnostic. Commissioning of the midplane MSE provided first direct measurements of diamagnetic modifications in the minimum magnetic field GDT section, a necessary complement to the understanding of equilibrium and self-organization of high-β plasmas in GDT. Making use of the stable short-pulse diagnostic beam and calibration of the apparent spectral width of beam emission lines allow for the measurement of the plasma magnetic field of 0.29 ± 0.007 T with the integration time of 200 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A new angle-resolved proton energy spectrometer

In typical laser-driven proton acceleration experiments Thomson parabola proton spectrometers are used to measure the proton spectra with very small acceptance angle in specific directions. Stacks composed of CR-39 nuclear track detectors, imaging plates, or radiochromic films are used to measure the angular distributions of the proton beams, respectively. In this paper, a new proton spectrometer, which can measure the spectra and angular distributions simultaneously, has been designed. Proton acceleration experiments performed on the Xtreme light III laser system demonstrates that the spectrometer can give angle-resolved spectra with a large acceptance angle. This will be conductive to revealing the acceleration mechanisms, optimization, and applications of laser-driven proton beams.