Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The 22 Ne(α,n) 25 Mg reaction - state of the art, astrophysics, and perspectives

One of the most important stellar neutron sources is the 22 Ne(α,n) 25 Mg reaction, which gets activated both during the helium intershell burning in asymptotic giant branch stars and in core helium and shell carbon burning in massive stars. The 22 Ne(α,n) 25 Mg reaction serves as the main neutron producer for the weak s-process and provides a short but strong neutron exposure during the helium flash phase of the main s-process, significantly affecting the abundances at the s-process branch points. The cross section needs to be known at very low energies, as close as possible to the neutron threshold at E α = 562 keV (Q = −478 keV), but both direct and indirect measurements have turned out to be very challenging, leading to significant uncertainties. Here we discuss the current status of the reaction, including recent and upcoming measurements, and provide a discussion on the astrophysical implications as well as an outlook into the near future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-pressure neutron diffraction at ultra-low temperature

Neutron diffraction is a powerful tool in the study of quantum materials and associated emergent phenomena as it allows for direct detection of magnetic structure even at ultra-low temperatures. As pressure can drive systems across quantum critical points and tune emergent behaviors at the quantum scale, coupling neutron diffraction with extreme conditions of high pressure at (ultra-)low temperatures has been a key research target over decades. This has proven challenging as magnetic neutron diffraction typically requires large sample volumes due to flux limitations, whereas high-pressure studies require small sample volumes due to pressure limitations. Combining these two contradictory requirements poses many difficulties, but also brings opportunities in research and development. Here, we address these shortcomings through the use of a diamond anvil cell equipped with polycrystalline anvils with relatively large sample volumes coupled with the high neutron flux made available by the high-pressure diffractometer of the Spallation Neutron Source. This particular diamond anvil cell configuration has previously proven useful for single-crystal samples and is here coupled with the ultra-low temperatures of a dilution refrigerator for the first time. Our study on a single crystal of Yb 2 ⁢O 3 successfully collected magnetic neutron diffraction data at 5.3 GPa below 200 mK inside a dilution refrigerator. We have performed a detailed analysis of the magnetic diffraction data to investigate the magnetic structure under pressure and observed a subtle shift in the transition temperature. This development will open the door for future studies on magnetic materials with these much-desired coupled extremes of high pressure and ultra-low temperatures.

Wu, Yan [Oak Ridge National Laboratory (ORNL), Oak↗

Charge multiplication in thin scCVD diamond detectors

This presentation describes experimental measurements with thin scCVD diamond detectors and their DD and DT neutron sources. This presentation will be given at the NNSS Prompt Radiation Detection and Imaging Workshop April 25-28, 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 22Ne($$\alpha $$,n)25Mg reaction - state of the art, astrophysics, and perspectives

Abstract One of the most important stellar neutron sources is the 22 Ne( $$\alpha ,n$$ α , n ) 25 Mg reaction, which gets activated both during the helium intershell burning in asymptotic giant branch stars and in core helium and shell carbon burning in massive stars. The 22 Ne( $$\alpha ,n$$ α , n ) 25 Mg reaction serves as the main neutron producer for the weak s -process and provides a short but strong neutron exposure during the helium flash phase of the main s -process, significantly affecting the abundances at the s -process branch points. The cross section needs to be known at very low energies, as close as possible to the neutron threshold at $$E_\alpha =$$ E α = 562 keV ( Q = −478 keV), but both direct and indirect measurements have turned out to be very challenging, leading to significant uncertainties. Here we discuss the current status of the reaction, including recent and upcoming measurements, and provide a discussion on the astrophysical implications as well as an outlook into the near future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elevated Electron Temperature Coincident with Observed Fusion Reactions in a Sheared-Flow-Stabilized Z Pinch

The sheared-flow-stabilized Z pinch concept has been studied extensively and is able to produce fusion-relevant plasma parameters along with neutron production over several microseconds. In this work, we present elevated electron temperature results spatially and temporally coincident with the plasma neutron source. An optical Thomson scattering apparatus designed for the FuZE device measures temperatures in the range of 1–3 keV on the axis of the device, 20 cm downstream of the nose cone. The 17-fiber system measures the radial profiles of the electron temperature. Scanning the laser time with respect to the neutron pulse time over a series of discharges allows the reconstruction of the T e temporal response, confirming that the electron temperature peaks simultaneously with the neutron output, as well as the pinch current and inductive voltage generated within the plasma. Comparison to spectroscopic ion temperature measurements suggests a plasma in thermal equilibrium. The elevated T e confirms the presence of a plasma assembled on axis, and indicates limited radiative losses, demonstrating a basis for scaling this device toward net gain fusion conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Report from: US Muon Workshop 2021: A Road Map for a Future Muon Facility February 1-2, 2021

The workshop titled “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, and beam and detector technologies that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

US Muon Workshop 2021: A road map for a future Muon Facility

The workshop title “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, alongside beam and detector technologies, that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities.

36 MATERIALS SCIENCE↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin-phonon coupling in AFM transition-metal mono-oxide

Time-of-flight INS measurements were performed on single crystal NiO with the Wide Angular Range Chopper Spectrometer (ARCS) at the Spallation Neutron Source. Experiments were performed on NiO single crystal mounted in an aluminum can and cooled using a closed-cycle helium refrigerator. Measurements were conducted at T = 100 K and 650 K, with the [HHL] scattering plane aligned horizontally. A Fermi chopper with slit spacing of 1.52mm, spinning at 300 Hz, was used to select an incident neutron energy of 100 meV. All datasets were normalized to a vanadium standard to correct for detector efficiency and solid angle coverage. The data sets include the .nxs files, the generated .hdf5 files (for use with Phonon Explorer), and Python scripts used to create them.

36 MATERIALS SCIENCE↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of the Neutronic Performance of IRP-1 and IRP-2 at SNS

The Spallation Neutron Source (SNS) operated from start-up, in May 2006, through December, 2017 before replacing the Inner Reflector Plug (IRP). This component is the most costly and time-consuming “regular maintenance” replacement foreseen in the operation of the First Target Station (FTS). The IRP includes beryllium reflector blocks, steel and aluminum support structures, aluminum moderator vessels (which in turn include gadolinium and cadmium neutron poisons) and water coolant systems. The lifetime of this multi-million dollar component is driven by poison and decoupler burnup in moderator vessels. The moderators include these neutron poisons to best match neutron beam performance with scattering instrument needs. The burnup that comes with use changes the performance of the moderators until they no longer server their intended purpose. The reasonable desire to maximize the IRP lifetime means that the moderator performance at the Beginning Of Life (BOL) is significantly “over poisoned” and different from the performance at moderator End Of Life (EOL). Upon installation of the second IRP article, IRP-2, the SNS Neutronics team characterized the performance of the neutron beamlines in order to assess the differences between them, primarily by comparing the EOL performance of IRP-1 to the BOL performance of IRP-2. While IRP-2 was largely similar to IRP-1 in its conceptual design, there were some differences in the specific design of IRP-2 to support enhanced manufacturability, and the change from IPR-1 to IRP-2 coincided with the replacement of the light water in the IRP cooling loop with heavy water, as had been intended in the SNS design but not implemented during construction because of heavy water availability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NDSE Static Series V & VI Test Results

The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Neutron Scattering Evaluation of Yttrium Hydride (FY2020 Progress)

This paper details the thermal neutron scattering measurements of yttrium hydride for various hydrogen concentrations and temperatures that were conducted at the Spallation Neutron Source at Oak Ridge National Laboratory. Measurements at a temperature range of 5 to 1,200 K were conducted to determine the change in inelastic scattering as a function of temperature and to probe for any anharmonic effects known to exist in other metallic hydrides. Additionally, hydrogen concentrations of YH x that range from x = 1.62 to 1.90 were measured to determine the effects of varying hydrogen concentration on the inelastic neutron spectra. Changes in temperature affected the inelastic spectra in unanticipated ways, indicating that there are anharmonic effects, whereas hydrogen concentration does not significantly affect the inelastic spectra. These measurements were compared against the ENDF/B-VIII.0 thermal scattering files of hydrogen in YH 2 and yttrium in YH 2 , as well as a new thermal scattering file created by using the stochastic temperature-dependent effective potential (s-TDEP). Both libraries were found to be in good agreement with the experimental data at lower temperatures. At higher temperatures, the s-TDEP method is better at predicting the experimentally observed softening of phonon modes in acoustic and optical regions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

IK-Frag: Frag data generator for the PHITS simulation with the inverse kinematic reaction producing a focused neutron beam

IK-Frag has been developed for the creation of the nuclear cross-section data format, which is named frag data and can be used in PHITS, a Monte Carlo simulation code. IK-Frag focuses on the inverse kinematic reactions between a lithium or beryllium ion and a proton target. These reactions achieve naturally collimated neutrons and potentially reduce the necessity of radiation shielding. IK-Frag enables PHITS users to conduct simulations for the inverse kinematic reactions. The present software aims to contribute to future development of the neutron source system using the inverse kinematic reactions.

43 PARTICLE ACCELERATORS↗

Neutron spectroscopy of plutonium using a handheld detection system

The ability to distinguish multiple forms of plutonium from one another, such as oxide and metal, is paramount in areas of nuclear nonproliferation and international safeguards. In its metal form, plutonium can be readily used in a nuclear weapon, while oxide forms are associated with nuclear reactor fuel. Oxide-based plutonium forms emit neutrons with an energy spectrum that is significantly different from the fission neutrons that are emitted from plutonium metal. Organic scintillation detectors output pulses that are proportional to the neutron energy deposited, and therefore present a means of distinguishing these plutonium forms based on their energy spectra. In this work, metal and oxide forms of plutonium were measured using a handheld detection system based on an organic glass scintillator. Monte Carlo modeling of these experiments was performed to provide insight into the origin of the features in the observed light output spectra. Through analysis of multiple regions of these spectra, in a matter of minutes we were able to unambiguously discriminate oxide and metal plutonium forms from one another and from a plutonium-beryllium neutron source, which was considered for comparison because these sources are commonly used in industrial applications. The ability to discriminate weapons-usable material from nuclear reactor fuel has applications in nuclear treaty verification and safeguards.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗