Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

"Eztrack": A single-vehicle deterministic tracking algorithm

A variety of surveillance operations require the ability to track vehicles over a long period of time using sequences of images taken from a camera mounted on an airborne or similar platform. In order to be able to see and track a vehicle for any length of time, either a persistent surveillance imager is needed that can image wide fields of view over a long time-span or a highly maneuverable smaller field-of-view imager is needed that can follow the vehicle of interest. The algorithm described here was designed for the persistence surveillance case. In turns out that most vehicle tracking algorithms described in the literature[1,2,3,4] are designed for higher frame rates (> 5 FPS) and relatively short ground sampling distances (GSD) and resolutions ({approx} few cm to a couple tens of cm). But for our datasets, we are restricted to lower resolutions and GSD's ({ge}0.5 m) and limited frame-rates ({le}2.0 Hz). As a consequence, we designed our own simple approach in IDL which is a deterministic, motion-guided object tracker. The object tracking relies both on object features and path dynamics. The algorithm certainly has room for future improvements, but we have found it to be a useful tool in evaluating effects of frame-rate, resolution/GSD, and spectral content (eg. grayscale vs. color imaging ). A block diagram of the tracking approach is given in Figure 1. We describe each of the blocks of the diagram in the upcoming sections.

42 ENGINEERING↗

Nanoparticle Tracking to Probe Transport in Porous Media

From the granular and fractured subsurface environment to highly engineered polymer membranes used in pharmaceutical purification, porous materials are ubiquitous in nature and industrial applications. In particular, porous media are used extensively in processes including water treatment, pharmaceutical sterilization, food/beverage processing and heterogeneous catalysis, where hindered mass transport is either essential to the process or a necessary, but undesirable limitation. Unfortunately, there are currently no universal models capable of predicting mass transport based on a description of the porous material because real porous materials are complex, and because many coupled dynamic mechanisms (e.g. adsorption, steric effects, hydrodynamic effects, electrostatic interactions, etc.) give rise to the observed macroscopic transport phenomena. While classical techniques, like nuclear magnetic resonance and dynamic light scattering, provide useful information about mass transport in porous media at the ensemble level, they provide limited insight into the microscopic mechanisms that give rise to complex phenomena such as anomalous diffusion, hindered pore-space accessibility, and unexpected retention under flow, among many others. To address this issue, we have developed refractive index matching imaging systems, combined with single-particle tracking methods, allowing the direct visualization of single particle motion within a variety of porous materials. Here, we summarize our recent efforts to advance the understanding of nanoparticle transport in porous media using single-particle tracking methods in both fundamental and applied scenarios. First, we describe the basic principles for two-dimensional and three-dimensional single-particle tracking in porous materials. Then, we describe concrete examples of nanoparticle transport in porous materials from two perspectives: (1) understanding fundamental elementary particle transport processes in porous media, including pore accessibility and cavity escape, which limit transport in porous media; (2) facilitating applications in industrial processes, e.g. by understanding the mechanisms of particle fouling and remobilization in filtration membranes. Finally, we provide an outlook of opportunities associated with investigating other types of mass transport in confined environments using single-particle tracking methods, including electrophoretic and self-propelled motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Positron emission tracking of individual particles in particle-laden rimming flow

The motion of a single tracer particle in particle-laden rimming flows is investigated experimentally by means of Positron Emission Particle Tracking (PEPT). Semi-dilute suspensions, with a volume fraction of 8% of heavy particles are considered. The trajectory of the tracer particle is monitored for several thousand cylinder revolutions and related to the optically recorded drift of the large-scale granular segregation bands developing in the cylinder. Results of the data analysis provide first insights into the relation between behaviour of individual particles and the spatiotemporal dynamics displayed by the macroscopic particle-segregation patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 Multiplication-Sign 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction ({approx}650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM Trade-Mark-Sign (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 {+-} 2.0 mm, 5.1 {+-} 3.1 mm, and 17.9 {+-} 5.1 mm in the planning 4DCT, and 2.8 {+-} 1.6 mm, 5.3 {+-} 3.1 mm, and 16.5 {+-} 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 {+-} 0.7 and 4.2 {+-} 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R{sup 2}= 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used.

60 APPLIED LIFE SCIENCES↗

Absolute properties of the eclipsing binary VV CORVI

We have obtained red-wavelength spectroscopy and Johnson B and V differential photoelectric photometry of the eclipsing binary VV Crv = HR 4821. The system is the secondary of the common proper motion double star ADS 8627, which has a separation of 5.''2. VV Crv has an orbital period of 3.144536 days and a low but non-zero eccentricity of 0.085. With the Wilson-Devinney program we have determined a simultaneous solution of our spectroscopic and photometric observations. Those orbital elements produce masses of M {sub 1} = 1.978 ± 0.010 M {sub ☉} and M {sub 2} = 1.513 ± 0.008 M {sub ☉}, and radii of R {sub 1} = 3.375 ± 0.010 R {sub ☉} and R {sub 2} = 1.650 ± 0.008 R {sub ☉} for the primary and secondary, respectively. The effective temperatures of the two components are 6500 K (fixed) and 6638 K, so the star we call the primary is the more massive but cooler and larger component. A comparison with evolutionary tracks indicates that the components are metal rich with [Fe/H] = 0.3, and the system has an age of 1.2 Gyr. The primary is near the end of its main-sequence lifetime and is rotating significantly faster than its pseudosynchronous velocity. The secondary is still well ensconced on the main sequence and is rotating more slowly than its pseudosynchronous rate.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-194: Continuous Patient Surface Monitoring and Motion Analysis During Lung SBRT

Purpose: Continuous monitoring of the SBRT lung patient motion during delivery is critical for ensuring adequate target volume margins in stereotactic body radiotherapy (SBRT). This work assesses the deviation of the patient surface motion using a real-time surface tracking system throughout treatment delivery. Methods: Our SBRT protocol employs abdominal compression to reduce the diaphragm movement to within 1 cm, and this is confirmed daily with fluoroscopy. Most patients are prescribed 3–5 fractions, and on treatment day a repeat motion analysis with fluoroscopy is performed, followed by a kV CBCT is aligned with the original planning CT image for 3D setup confirmation. During this entire process a patient surface data restricted to whole chest or the sternum at the middle of the breathing cycle was captured using AlignRT optical surface tracking system and defined as a reference surface. For 10 patients, the deviation of the patient position from the reference surface was recorded during the SBRT delivery in the anterior-posterior (AP) direction at 3–6 measurements per second. Results: On average, the patient position deviated from the reference surface more than 4 mm, 3 mm and 2 mm in the AP direction for 0.95%, 3.7% and 11.1% of the total treatment time, respectively. Only one of the 10 patients showed that the maximum deviation of the patient surface during the SBRT delivery was greater than 1 cm. The average deviation of the patient surface from the reference surface during the SBRT delivery was not greater than 1.6 mm for any patient. Conclusion: This investigation indicates that AP motion can be significant even though the frequency is low. Continuous monitoring during SBRT has demonstrated value in monitoring patient motion ensuring that margins selected for SBRT are appropriate, and the use of non-ionizing and high-frequency imaging can provide useful indicators of motion during treatment.

60 APPLIED LIFE SCIENCES↗

Technical Note: Intrafractional changes in time lag relationship between anterior–posterior external and superior–inferior internal motion signals in abdominal tumor sites

Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior–inferior (SI) internal and anterior–posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Results: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01–0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01–0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%–10.8%) of gate width (range 1.6–3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Conclusions: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.

60 APPLIED LIFE SCIENCES↗

Lung tumor tracking in fluoroscopic video based on optical flow

Respiratory gating and tumor tracking for dynamic multileaf collimator delivery require accurate and real-time localization of the lung tumor position during treatment. Deriving tumor position from external surrogates such as abdominal surface motion may have large uncertainties due to the intra- and interfraction variations of the correlation between the external surrogates and internal tumor motion. Implanted fiducial markers can be used to track tumors fluoroscopically in real time with sufficient accuracy. However, it may not be a practical procedure when implanting fiducials bronchoscopically. In this work, a method is presented to track the lung tumor mass or relevant anatomic features projected in fluoroscopic images without implanted fiducial markers based on an optical flow algorithm. The algorithm generates the centroid position of the tracked target and ignores shape changes of the tumor mass shadow. The tracking starts with a segmented tumor projection in an initial image frame. Then, the optical flow between this and all incoming frames acquired during treatment delivery is computed as initial estimations of tumor centroid displacements. The tumor contour in the initial frame is transferred to the incoming frames based on the average of the motion vectors, and its positions in the incoming frames are determined by fine-tuning the contour positions using a template matching algorithm with a small search range. The tracking results were validated by comparing with clinician determined contours on each frame. The position difference in 95% of the frames was found to be less than 1.4 pixels ({approx}0.7 mm) in the best case and 2.8 pixels ({approx}1.4 mm) in the worst case for the five patients studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target tracking using DMLC for volumetric modulated arc therapy: A simulation study

Purpose: Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. Methods: The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. Results: The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. Conclusions: A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pebble Fuel Handling and Reactivity Control for Salt-Cooled High Temperature Reactors

This report documents the work completed on the X-PREX facility under NEUP Project 11- 3172. This project seeks to demonstrate the viability of pebble fuel handling and reactivity control for fluoride salt-cooled high-temperature reactors (FHRs). The research results also improve the understanding of pebble motion in helium-cooled reactors, as well as the general, fundamental understanding of low-velocity granular flows. Successful use of pebble fuels in with salt coolants would bring major benefits for high-temperature reactor technology. Pebble fuels enable on-line refueling and operation with low excess reactivity, and thus simpler reactivity control and improved fuel utilization. If fixed fuel designs are used, the power density of salt- cooled reactors is limited to 10 MW/m 3 to obtain adequate duration between refueling, but pebble fuels allow power densities in the range of 20 to 30 MW/m 3 . This can be compared to the typical modular helium reactor power density of 5 MW/m3. Pebble fuels also permit radial zoning in annular cores and use of thorium or graphite pebble blankets to reduce neutron fluences to outer radial reflectors and increase total power production. Combined with high power conversion efficiency, compact low-pressure primary and containment systems, and unique safety characteristics including very large thermal margins (>500°C) to fuel damage during transients and accidents, salt-cooled pebble fuel cores offer the potential to meet the major goals of the Advanced Reactor Concepts Development program to provide electricity at lower cost than light water reactors with improved safety and system performance.This report presents the facility description, experimental results, and supporting simulation methods of the new X-Ray Pebble Recirculation Experiment (X-PREX), which is now operational and being used to collect data on the behavior of slow dense granular flows relevant to pebble bed reactor core designs. The X-PREX facility uses novel digital x-ray tomography methods to track both the translational and rotational motion of spherical pebbles, which provides unique experimental results that can be used to validate discrete element method (DEM) simulations of pebble motion. The validation effort supported by the X-PREX facility provides a means to build confidence in analysis of pebble bed configuration and residence time distributions that impact the neutronics, thermal hydraulics, and safety analysis of pebble bed reactor cores. Experimental and DEM simulation results are reported for silo drainage, a classical problem in the granular flow literature, at several hopper angles. These studies include conventional converging and novel diverging geometries that provide additional flexibility in the design of pebble bed reactor cores. Excellent agreement is found between the X-PREX experimental and DEM simulation results. This report also includes results for additional studies relevant to the design and analysis of pebble bed reactor cores including the study of forces on shut down blades inserted directly into a packed bed and pebble flow in a cylindrical hopper that is representative of a small test reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dosimetric Consequences of Intrafraction Prostate Motion

Purpose: To analyze characteristics of intrafraction prostate motion, monitored using the Calypso system, and investigate dosimetric consequences of the motion for different clinical target volume (CTV) to planning target volume (PTV) margins. Methods and Materials: Motion characteristics were analyzed for 1,267 tracking sessions and 35 patients. Using prostate-PTV margins of 0, 1, 2, 3, and 5 mm, dose metrics for the prostate gland, bladder, and rectum were evaluated for scenarios including patient population, individual patients showing the greatest motion during the course of treatment, and the individual session with the largest overall movement. Composite dose distributions incorporating motion blurring were calculated by convolving static intensity-modulated radiotherapy plans with corresponding motion probability functions. Results: For prostate-PTV margins of 2 mm or greater, intrafraction motion did not compromise prostate dose coverage for either the patient population or individual patients. For the patient showing the largest overall movement, the prostate equivalent uniform dose was reduced by only 17.4 cGy (0.23%), and the minimum prostate dose remained greater than 95% of the nominal dose. For margins less than 2 mm, the prostate dose-volume histogram in the same patient was slightly compromised, and the equivalent uniform dose was reduced by 38.5 cGy (0.51%). Sparing of the bladder and rectum was improved substantially by reducing margins. Conclusions: Although significant motion can be observed during individual fractions, the dosimetric consequences are insignificant during a typical course of radiotherapy (30-40 fractions) with CTV-PTV margins of 2 mm or greater provided that the Calypso system is applied for pretreatment localization. Further reduction of the margin is possible if intrafraction realignment is performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRA-15: Dosimetric Evaluation of Dynamic Tumor Tracking Radiation Therapy Using Digital Phantom: A Study On Margin and Desired Accuracy of Tracking

Purpose: Dynamic tumor tracking radiation therapy can potentially reduce internal margin without prolongation of irradiation time. However, dynamic tumor tracking technique requires an extra margin (tracking margin, TM) for the uncertainty of tumor localization, prediction, and beam repositioning. The purpose of this study was to evaluate a dosimetric impact caused by TM. Methods: We used 4D XCAT to create 9 digital phantom datasets of different tumor size and motion range: tumor diameter TD=(1, 3, 5) cm and motion range MR=(1, 2, 3) cm. For each dataset, respiratory gating (30%–70% phase) and tumor tracking treatment plans were created using 8-field 3D-CRT by 4D dose calculation implemented in RayStation. The dose constraint was based on RTOG0618. For the tracking plan, TMs of (0, 2.5, 5) mm were considered by surrounding a normal setup margin: SM=5 mm. We calculated V20 of normal lung to evaluate the dosimetric impact for each case, and estimated an equivalent TM that affects the same impact on V20 obtained by the gated plan. Results: The equivalent TMs for (TD=1 cm, MR=2 cm), (TD=1 cm, MR=3 cm), (TD=5 cm, MR=2 cm), and (TD=5 cm, MR=3 cm) were estimated as 1.47 mm, 3.95 mm, 1.04 mm, and 2.13 mm, respectively. The larger the tumor size, the equivalent TM became smaller. On the other hand, the larger the motion range, the equivalent TM was found to be increased. Conclusion: Our results showed the equivalent TM changes depending on tumor size and motion range. The tracking plan with TM less than the equivalent TM achieves a dosimetric impact better than the gated plan in less treatment time. This study was partially supported by JSPS Kakenhi and Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Assessment of different coarse graining strategies to simulate polydisperse gas-solids flow

Continuum methods require the additional development of solids stress closures for polydisperse powders based on complex kinetic theories that are non-trivial to develop, code, and numerically converge for the wide range of fluidization regimes from very dilute to dense/frictional flow limit. On the other hand, it is straightforward to model the flow of polydisperse granular materials by treating particles as discrete rigid bodies that are tracked following simple physical laws of motion. The coarsening of these discrete methods by lumping several particles in a parcel alleviates the significant computational cost associated with these discrete methods while introducing some inaccuracies in the numerical results. In this research, we explore two different coarse graining methods that can be applied to polydisperse powders, namely the same statistic weight method (SSW) and the same size parcel method (SSP), and assess their accuracy by comparison with the finest simulation results obtained with a discrete element method (DEM). For Geldart group B powders fluidized at a relative low superficial velocity, the numerical results indicate that the SSW is more accurate than the SSP method. For type A powders fluidized at relatively high velocity, these two methods predict similar results. Interestingly, up to four times increase in the speed of simulation of the SSP method was obtained because the original polydisperse powder is scaled to a mono-disperse system in terms of particle-particle collision. Lastly, these results suggest that the SSP method is more favorable for the simulation of fluidized beds due to its accuracy and efficiency while the SSW method may be used for granular flow and dense fluidized bed systems where capturing the size segregation of particles due to collision is important.

42 ENGINEERING↗

Deep Inspiration Breath Hold—Based Radiation Therapy: A Clinical Review

Several recent developments in linear accelerator–based radiation therapy (RT) such as fast multileaf collimators, accelerated intensity modulation paradigms like volumeric modulated arc therapy and flattening filter-free (FFF) high-dose-rate therapy have dramatically shortened the duration of treatment fractions. Deliverable photon dose distributions have approached physical complexity limits as a consequence of precise dose calculation algorithms and online 3-dimensional image guided patient positioning (image guided RT). Simultaneously, beam quality and treatment speed have continuously been improved in particle beam therapy, especially for scanned particle beams. Applying complex treatment plans with steep dose gradients requires strategies to mitigate and compensate for motion effects in general, particularly breathing motion. Intrafractional breathing-related motion results in uncertainties in dose delivery and thus in target coverage. As a consequence, generous margins have been used, which, in turn, increases exposure to organs at risk. Particle therapy, particularly with scanned beams, poses additional problems such as interplay effects and range uncertainties. Among advanced strategies to compensate breathing motion such as beam gating and tracking, deep inspiration breath hold (DIBH) gating is particularly advantageous in several respects, not only for hypofractionated, high single-dose stereotactic body RT of lung, liver, and upper abdominal lesions but also for normofractionated treatment of thoracic tumors such as lung cancer, mediastinal lymphomas, and breast cancer. This review provides an in-depth discussion of the rationale and technical implementation of DIBH gating for hypofractionated and normofractionated RT of intrathoracic and upper abdominal tumors in photon and proton RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interference Provides Clarity: Direct Observation of 2D Materials at Fluid–Fluid Interfaces

Monolayer particles of two-dimensional (2D) materials represent a scientifically and technologically interesting class of anisotropic particles with colloidal-scale lateral sizes but sub-nanometer thicknesses. This atomic-scale thickness leads to interesting phenomena that can be exploited in next-generation thin-film technologies, and fluid-fluid interfaces provide a potentially scalable platform to confine, assemble, and deposit functional thin films of 2D materials. However, directly observing how these materials interact and assemble into a given film morphology is experimentally challenging because of their sub-nanometer thicknesses. Here, we demonstrate the ability to directly observe graphene, molybdenum disulfide (MoS2), and hexagonal boron nitride (h-BN) particles at fluid-fluid interfaces using interference reflection microscopy (IRM). Monolayer MoS2 and graphene particles demonstrated >10% optical contrast at an air-water interface, which allowed us to quantitatively analyze in situ images of self-assembled MoS2 particles and to map trajectories of interacting graphene particles. Additionally, the Brownian motion of a graphene particle was tracked and analyzed in the context of passive microrheology theory for 2D particle probes. Our results demonstrate how IRM can be used to obtain quantitative spatiotemporal information regarding the self-assembly and dynamics of 2D materials at fluid-fluid interfaces. It will have a significant impact on our ability to investigate systems of atomically thin particles at fluid-fluid interfaces, an area that has fundamental scientific importance and materials science applications but has suffered from a lack of direct, in situ observation techniques.

2D material↗

Aging power spectrum of membrane protein transport and other subordinated random walks

Single-particle tracking offers detailed information about the motion of molecules in complex environments such as those encountered in live cells, but the interpretation of experimental data is challenging. One of the most powerful tools in the characterization of random processes is the power spectral density. However, because anomalous diffusion processes in complex systems are usually not stationary, the traditional Wiener-Khinchin theorem for the analysis of power spectral densities is invalid. Here, we employ a recently developed tool named aging Wiener-Khinchin theorem to derive the power spectral density of fractional Brownian motion coexisting with a scale-free continuous time random walk, the two most typical anomalous diffusion processes. Using this analysis, we characterize the motion of voltage-gated sodium channels on the surface of hippocampal neurons. Our results show aging where the power spectral density can either increase or decrease with observation time depending on the specific parameters of both underlying processes.

59 BASIC BIOLOGICAL SCIENCES↗

TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through the volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope Tracking is sensitive to erratic camera motion and local optima, but could be used in conjunction with anchor points found using Location Search.

60 APPLIED LIFE SCIENCES↗

Deep Learning for Fish Identification from Sonar Data: CRADA 481 [Abstract only]

To help solve the challenges of hydropower energy production related to the potential for eel injury and mortality from passage through hydropower turbines, we will develop a deep learning method for identifying migrating eels from imaging sonar. This project continues with a prior project conducted by the Pacific Northwest National Laboratory (PNNL) and the Electric Power Research Institute (EPRI) in FY2018-2019. The proposed method employs Convolution Neural Network (CNN), a powerful deep learning method for image classification, to distinguish between images of eels and non-eel moving objects. We propose to collect more laboratory data and add more existing field data to train a powerful deep learning model. In addition to eels and sticks as classified in previous studies, we will add images containing several non-eel fish species and macrophyte mats to the training data. A multi-class classification model will be developed to distinguish these objects. Object detection algorithm will be explored and developed to locate and identify multiple objects in each sonar frame. Motion analysis will be performed to track the movement of objects in sonar video clips. We will also improve the data conversion algorithm so that it can read in both DIDSON and ARIS (both are imaging sonars developed by Sound Metrics Corp) data files and convert them to images with comparably high resolution, regardless of the varying detection ranges in different environments. The developed algorithms will be packaged as a software with a graphic user interface. The software will be evaluated by external collaborators in the field. The developed framework can be generalized for automatic monitoring of fish passage and migration using other imaging sonars like ARIS and will benefit the design and operation of ecologically friendly hydroelectric projects. The developed wavelet and CNN model configuration parameters can potentially be transferred to lamprey detection in similar riverine environments.

13 HYDRO ENERGY↗