Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Contact Versus Non-Contact Measurement of a Helicopter Main Rotor Composite Blade

The dynamic characterization of lightweight structures is particularly complex as the impact of the weight of sensors and instrumentation (cables, mounting of exciters...) can distort the results. Varying mass loading or constraint effects between partial measurements may determine several errors on the final conclusions. Frequency shifts can lead to erroneous interpretations of the dynamics parameters. Typically these errors remain limited to a few percent. Inconsistent data sets however can result in major processing errors, with all related consequences towards applications based on the consistency assumption, such as global modal parameter identification, model-based damage detection and FRF-based matrix inversion in substructuring, load identification and transfer path analysis [1]. This paper addresses the subject of accuracy in the context of the measurement of the dynamic properties of a particular lightweight structure. It presents a comprehensive comparative study between the use of accelerometer, laser vibrometer (scanning LDV) and PU-probe (acoustic particle velocity and pressure) measurements to measure the structural responses, with as final aim the comparison of modal model quality assessment. The object of the investigation is a composite material blade from the main rotor of a helicopter. The presented results are part of an extensive test campaign performed with application of SIMO, MIMO, random and harmonic excitation, and the use of the mentioned contact and non-contact measurement techniques. The advantages and disadvantages of the applied instrumentation are discussed. Presented are real-life measurement problems related to the different set up conditions. Finally an analysis of estimated models is made in view of assessing the applicability of the various measurement approaches for successful fault detection based on modal parameters observation as well as in uncertain non-deterministic numerical model updating.

36 MATERIALS SCIENCE↗

SU-F-T-305: Clinical Effects of Dosimetric Leaf Gap (DLG) Values Between Matched Varian Truebeam (TB) Linacs

Purpose: The dosimetric leaf gap (DLG) is an important parameter to be measured for dynamic beam delivery of modern linacs, like the Varian Truebeam (TB). The clinical effects of DLG-values on IMRT and/or VMAT commissioning of two “matched” TB linacs will be presented.Methods and Materials: The DLG values on two TB linacs were measured for all energy modalities (filtered and FFF-modes) as part of the dynamic delivery mode commissioning (IMRT and/or VMAT. After the standard beam data was modeled in eclipse treatment planning system (TPS) and validated, IMRT validation was performed based on TG1191 benchmark, IROC Head-Neck (H&N) phantom and sample of clinical cases, all measured on both linacs. Although there was a single-set of data entered in the TPS, a noticeable difference was observed for the DLG-values between the linacs. The TG119, IROC phantom and selected patient plans were furnished with DLG-values of TB1 for both linacs and the delivery was performed on both TB linacs for comparison. Results: The DLG values of TB1 was first used for both linacs to perform the testing comparisons. The QA comparison of TG119 plans revealed a great dependence of the results to the DLG-values used for the linac for all energy modalities studied, especially when moving from 3%/3mm to 2%/2mm γ-analysis. Conclusion: The DLG-values have a definite influence on the dynamic dose, delivery that increases with the plan complexity. We recommend that the measured DLG-values are assigned to each of the “matched” linacs, even if a single set of beam data describes multiple linacs. The user should perform a detail test of the dynamic delivery of each linac based on end-to-end benchmark suites like TG119 and IROC phantoms.1Ezzel G., et al., “IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.” Med. Phys. 36:5359–5373 (2009). partly supported by CAMC Cancer Center and Alliance Oncology.

60 APPLIED LIFE SCIENCES↗

Distribution of Iron Oxide Core-Titanium Dioxide Shell Nanoparticles in VX2 Tumor Bearing Rabbits Introduced by Two Different Delivery Modalities

This work compares intravenous (IV) versus fluoroscopy-guided transarterial intra-catheter (IC) delivery of iron oxide core-titanium dioxide shell nanoparticles (NPs) in vivo in VX2 model of liver cancer in rabbits. NPs coated with glucose and decorated with a peptide sequence from cortactin were administered to animals with developed VX2 liver cancer. Two hours after NPs delivery tumors, normal liver, kidney, lung and spleen tissues were harvested and used for a series on histological and elemental analysis tests. Quantification of NPs in tissues was done both by bulk inductively coupled plasma mass spectrometry (ICP-MS) analysis and by hard X-ray fluorescence microscopy. Both IV and IC NPs injection are feasible modalities for delivering NPs to VX2 liver tumors with comparable tumor accumulation. It is possible that this is an outcome of the fact that VX2 tumors are highly vascularized and hemorrhagic, and therefore enhanced permeability and retention (EPR) plays the most significant role in accumulation of nanoparticles in tumor tissue. It is, however, interesting to note that IV delivery led to increased sequestration of NPs by spleen and normal liver tissue, while IC delivery lead to more NP positive Kupffer cells. This difference is most likely a direct outcome of blood flow dynamics. Armed with this knowledge about nanoparticle delivery, we plan to test them as radiosensitizers in the future.

36 MATERIALS SCIENCE↗

Quantitative analysis of carbonaceous aerosols using Laser-Induced Breakdown Spectroscopy: A study on mass loading induced plasma matrix effects.

We present results indicating mass loading induced plasma matrix effects on the application of quantitative laser-induced breakdown spectroscopy (LIBS) for estimation of carbon contents in aerosols. An in-house flow-controlled powder-dispersion system generated carbonaceous aerosols with varying bi-modal particle size distributions ({approx} 1 {micro}m and 10 {micro}m median diameters), thereby resulting in a wide mass loading range. For ease of chemical handling and to eliminate toxic effects, common talcum powder was used as our standard aerosol. Normalized atomic species concentrations of C, i.e., (C)/(Si) ratios, were calculated from atomic emission lines of C I (248 nm), Si I (252 nm), and plasma temperatures estimated from a series of Mg I lines. The results show a decrease in (C)/(Si) ratio to about 65% of the initial value as relative mass loadings increased (5.5-100%) due to the increase in number concentrations of larger sized particles ({approx}10 {micro}m median diameter). As a comparison, normalized ratio of (Mg)/(Si) did not exhibit any marked change with increased mass loading. The normalized total absorption of photon flux across the C I (248 nm) spectral line indicated a strong correlation to the percentage decrease in (C)/(Si) ratio. We used an impactor with a cut-off size of around 10 {micro}m diameter to generate mono-modal aerosolized powders ({approx}1 {micro}m median diameter) that had lower relative mass loadings (0.32-0.16%). Similar LIBS analysis on these did not indicate any of the matrix effects. We conclude that for aerosol systems with widely varying mass loadings, quantitative LIBS analysis can be significantly affected by plasma matrix effects, specifically for the C I (248 nm) emission line as noticed in this study. This bears significance for the application of quantitative LIBS in the chemical characterization of all forms of carbonaceous aerosols.

Mukherjee, Dibyendu↗

Potential for Higher Treatment Failure in Obese Patients: Correlation of Elevated Body Mass Index and Increased Daily Prostate Deviations From the Radiation Beam Isocenters in an Analysis of 1,465 Computed Tomographic Images

Purpose: Recent clinical outcome studies on prostate cancer have reported the influence of patient's obesity on the biochemical failure rates after various treatment modalities. In this study, we investigated the effect of patient's physical characteristics on prostate shift in external beam radiotherapy (EBRT) and hypothesized that there maybe a correlation between patient physique and tumor shift. Methods and Materials: A retrospective analysis was performed using data for 117 patients who received image-guided radiation therapy (IGRT) for prostate cancer between January 2005 and April 2007. A total of 1,465 CT scans were analyzed. The standard deviations (SDs) of prostate shifts for all patients, along with patient weight, body mass index (BMI), and subcutaneous adipose-tissue thickness (SAT), were determined. Spearman rank correlation analysis was performed. Results: Of the 117 patients, 26.5% were considered normal weight, 48.7% were overweight, 17.9% were mildly obese, and 6.9% were moderately to severely obese. Notably 1.3%, 1.5%, 2.0%, and 21.2% of the respective shifts were greater than 10 mm in the left-right (LR) direction for the four patient groups, whereas in the anterior-posterior direction the shifts are 18.2%, 12.6%, 6.7%, and 21.0%, respectively. Strong correlations were observed between SAT, BMI, patient weight, and SDs of daily shifts in the LR direction (p < 0.01). Conclusions: The strong correlation between obesity and shift indicates that without image-guided radiation therapy, the target volume (prostate with or without seminal vesicles) may not receive the intended dose for patients who are moderate to severely obese. This may explain the higher recurrence rate with conventional external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling most likely pathways for smuggling radioactive and special nuclear materials on a worldwide multi-modal transportation network

Nuclear weapons proliferation is an existing and growing worldwide problem. To help with devising strategies and supporting decisions to interdict the transport of nuclear material, we developed the Pathway Analysis, Threat Response and Interdiction Options Tool (PATRIOT) that provides an analytical approach for evaluating the probability that an adversary smuggling radioactive or special nuclear material will be detected during transit. We incorporate a global, multi-modal transportation network, explicit representation of designed and serendipitous detection opportunities, and multiple threat devices, material types, and shielding levels. This paper presents the general structure of PATRIOT, all focuses on the theoretical framework used to model the reliabilities of all network components that are used to predict the most likely pathways to the target.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Prospective Imaging Assessment of Mortality Risk After Head-and-Neck Radiotherapy

Purpose: The optimal roles for imaging-based biomarkers in the management of head-and-neck cancer remain undefined. Unresolved questions include whether functional or anatomic imaging might improve mortality risk assessment for this disease. We addressed these issues in a prospective institutional trial. Methods and Materials: Ninety-eight patients with locally advanced pharyngolaryngeal squamous cell cancer were enrolled. Each underwent pre- and post-chemoradiotherapy contrast-enhanced computed tomography (CT) and {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/CT imaging. Imaging parameters were correlated with survival outcomes. Results: Low post-radiation primary tumor FDG avidity correlated with improved survival on multivariate analysis; so too did complete primary tumor response by CT alone. Although both imaging modalities lacked sensitivity, each had high specificity and negative predictive value for disease-specific mortality risk assessment. Kaplan-Meier estimates confirmed that both CT and FDG-PET/CT stratify patients into distinct high- and low-probability survivorship groups on the basis of primary tumor response to radiotherapy. Subset analyses demonstrated that the prognostic value for each imaging modality was primarily derived from patients at high risk for local treatment failure (human papillomavirus [HPV]-negative disease, nonoropharyngeal primary disease, or tobacco use). Conclusions: CT alone and FDG-PET/CT are potentially useful tools in head-and-neck cancer-specific mortality risk assessment after radiotherapy, particularly for selective use in cases of high-risk HPV-unrelated disease. Focus should be placed on corroboration and refinement of patient selection for imaging-based biomarkers in future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal and Statistical Mapping of Transition Metal Equilibria in Alkaline Media

Transition metal dissolution and redeposition (D/R) kinetics in alkaline media play a critical role in various chemical and electrochemical processes. Competitive reaction kinetics between different transition metals can modulate individual metal behavior in these processes. To date, these phenomena have remained largely unmeasured, and even when captured, they are difficult to statistically characterize due to their dynamic nature, simultaneous occurrence, and spatially heterogeneous nature. Here, in this study, we develop a statistical analysis framework based on in situ and operando X-ray fluorescence microscopy (XFM) to investigate the relative D/R kinetics of multiple transition metals in alkaline media. By employing statistical analysis, we quantify the spatial distribution of D/R species and assess the rate at which the system reaches equilibrium under varying reaction conditions. We show that pH does not simply change the rate of dissolution and redeposition, but reorganizes the cross-element kinetic correlations among Ni, Fe, and Mn and accelerates the spatial equilibration of D/R events, as quantified through correlation analysis, reaction-rate estimation, probability function distributions, and texture-based monitoring statistics. Additionally, we demonstrate how modifying the solvent environment can influence D/R kinetics, providing a pathway for tuning materials synthesis and process optimization. Our study offers valuable insights into the complex interplay between different transition metals and provides a reliable statistical framework for spatial analysis of diverse imaging data sets, enabling deeper extraction of latent information across multiple modalities.

36 MATERIALS SCIENCE↗

Machine Learning of Factors Influencing Damping and Frequency of Dominant Inter-area Modes in the WECC Interconnect

The stability of inter-area electromechanical oscillations are critical to power system reliability. Due to the complexities of power systems, relationships between system conditions and oscillation characteristics, such as damping and frequency, tend to be expressed only in generalities. In this study, a list of influential factors on Western Electricity Coordinating Council (WECC) interconnect modal characteristics are identified and evaluated with advanced machine learning techniques including principal component analysis, analysis of variance, random forest feature selection, support vector machine, and artificial neural network approaches.

Hou, Zhangshuan↗

Internal margin assessment using cine MRI analysis of deglutition in head and neck cancer radiotherapy

Purpose: Intensity-modulated radiation therapy (IMRT) is a promising treatment modality for patients with head and neck cancer (HNC). The dose distributions from IMRT are static and, thus, are unable to account for variations and/or uncertainties in the relationship between the patient (region being treated) and the beam. Organ motion comprises one such source of this uncertainty, introduced by physiological variation in the position, size, and shape of organs during treatment. In the head and neck, the predominant source of this variation arises from deglutition (swallowing). The purpose of this study was to investigate whether cinematographic MRI (cine MRI) could be used to determine asymmetric (nonuniform) internal margin (IM) components of tumor planning target volumes based on the actual deglutition-induced tumor displacement. Methods: Five head and neck cancer patients were set up in treatment position on a 3 T MRI scanner. Two time series of single-slice, sagittal, cine images were acquired using a 2D FLASH sequence. The first time series was a 12.8 min scan designed to capture the frequency and duration of deglutition in the treatment position. The second time series was a short, 15 s scan designed to capture the displacement of deglutition in the treatment position. Deglutition frequency and mean swallow duration were estimated from the long time series acquisition. Swallowing and resting (nonswallowing) events were identified on the short time series acquisition and displacement was estimated based on contours of gross tumor volume (GTV) generated at each time point of a particular event. A simple linear relationship was derived to estimate 1D asymmetric IMs in the presence of resting- and deglutition-induced displacement. Results: Deglutition was nonperiodic, with frequency and duration ranging from 2.89-24.18 mHz and from 3.86 to 6.10 s, respectively. The deglutition frequency and mean duration were found to vary among patients. Deglutition-induced maximal GTV displacements ranged from 0.00 to 28.36 mm with mean and standard deviation of 4.72{+-}3.18, 3.70{+-}2.81, 2.75{+-}5.24, and 10.40{+-}10.76 mm in the A, P, I, and S directions, respectively. Resting-induced maximal GTV displacement ranged from 0.00 to 5.59 mm with mean and standard deviation of 3.01{+-}1.80, 1.25{+-}1.10, 3.23+2.20, and 2.47{+-}1.11 mm in the A, P, I, and S directions, respectively. For both resting and swallowing states, displacement along the S-I direction dominated displacement along the A-P direction. The calculated IMs were dependent on deglutition frequency, ranging from 3.28-4.37 mm for the lowest deglutition frequency patient to 3.76-6.43 mm for the highest deglutition frequency patient. A statistically significant difference was detected between IMs calculated for P and S directions (p=0.0018). Conclusions: Cine MRI is able to capture tumor motion during deglutition. Swallowing events can be demarcated by MR signal intensity changes caused by anatomy containing fully relaxed spins that move medially into the imaging plane during deglutition. Deglutition is nonperiodic and results in dynamic changes in the tumor position. Deglutition-induced displacements are larger and more variable than resting displacements. The nonzero mean maximum resting displacement indicates that some tumor motion occurs even when the patient is not swallowing. Asymmetric IMs, derived from deglutition frequency, duration, and directional displacement, should be employed to account for tumor motion in HNC RT.

60 APPLIED LIFE SCIENCES↗

Evaluating Contributions of Pitch-Carbon Coating to Improved Stability of Si Anodes Through Voltage-Resolved Multi-Phase Characterization

Silicon nanoparticles have emerged as a promising alternative to graphite to improve the energy density of next-generation lithium-ion battery anodes. Nano-sized Si domains facilitate rapid ion transport and minimize particle-scale mechanical degradation, but also exhibit increased (electro)chemical reactivity with Li-ion electrolyte components due to their high surface area. We have previously demonstrated that surface modification of Si nanoparticles with pitch-carbon is an effective strategy to reduce these parasitic reactions. In the present work, we holistically evaluate the mechanistic contribution of pitch-carbon coating to the observed stability improvement over uncoated Si. We utilize coupled in situ and ex situ methods to probe changes to solid-surface, volatile headspace, and gas-phase chemistry occurring during initial cycling. Measurements taken at targeted potentials associated with electrolyte species reduction enables the decoupling of specific reaction pathways tied to interfacial stability. Further, we demonstrate the non-trivial role of gas reconsumption in dictating the nature of the passivating surface layer evolved on both uncoated and pitch-coated Si. This multi-phase analysis offers insights into the mechanism of effective surface passivation, which may be applied to inform future Si material development.

ENERGY STORAGE↗

Bolide Infrasound Signal Morphology and Yield Estimates: A Case Study of Two Events Detected by a Dense Acoustic Sensor Network

Two bolides (2016 June 2 and 2019 April 4) were detected at multiple regional infrasound stations, with many of the locations receiving multiple detections. Analysis of the received signals was used to estimate the yield, location, and trajectory, as well as the type of shock that produced the received signal. The results from the infrasound analysis were compared with ground-truth information that was collected through other sensing modalities. This multimodal framework offers an expanded perspective on the processes governing bolide shock generation and propagation. The majority of signal features showed reasonable agreement between the infrasound-based interpretation and the other observational modalities, though the yield estimate from the 2019 bolide was significantly lower using the infrasound detections. There was also evidence suggesting that one of the detections was from a cylindrical shock that was initially propagating upward, which is unusual though not impossible.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. In this paper, we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na + sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na + concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.

47 OTHER INSTRUMENTATION↗

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Biochemical Relapse-Free Survival Between Primary Gleason Score 3 and Primary Gleason Score 4 for Biopsy Gleason Score 7 Prostate Cancer

Purpose: To determine whether the primary grade (PG) of biopsy Gleason score (GS) 7 prostate cancer (CaP) was predictive for biochemical relapse-free survival (bRFS). Most of the present data regarding the PG of GS7 CaP refer to surgical specimens. Our goal was to determine whether the biopsy GS used at the time of medical decision making predicted for the biochemical outcome. Methods and Materials: We reviewed the data from 705 patients with biopsy GS7 CaP, from a prospectively maintained database, who had been treated at our institution between September 1996 and March 2005 with radical prostatectomy (n = 310), external beam radiotherapy (n = 268), or prostate radioactive seed implantation (n = 127). The bRFS rates were estimated using the Kaplan-Meier method. Cox proportional hazards regression analysis was used for univariate and multivariate analyses examining these factors in relation to bRFS: PG of biopsy GS, initial prostate-specific antigen level, clinical T stage, use of androgen deprivation, risk group (high or intermediate), and treatment modality. Results: The 5-year bRFS rate was 78% and 71% (p = 0.0108) for biopsy GS7 PG3 CaP and biopsy GS7 PG4 CaP, respectively. Comparing PG3 and PG4 within treatment modalities, only prostate implantation patients had a significant difference in the 5-year bRFS rate, 88% vs. 76%, respectively (p = 0.0231). On multivariate analysis, the PG of biopsy GS remained an independent predictor of bRFS, with PG3 having better bRFS than PG4 (relative risk, 0.655; 95% confidence interval, 0.472-0.909; p = 0.0113). Conclusion: Biopsy GS7 PG4 CaP carries a worse bRFS than biopsy GS7 PG3 CaP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-41: Analysis of GI Dose Variability Due to Intrafraction Setup Variance

Purpose: Proton SBRT (stereotactic body radiation therapy) can be an effective modality for treatment of gastrointestinal tumors, but limited in practice due to sensitivity with respect to variation in the RPL (radiological path length). Small, intrafractional shifts in patient anatomy can lead to significant changes in the dose distribution. This study describes a tool designed to visualize uncertainties in radiological depth in patient CT's and aid in treatment plan design. Methods: This project utilizes the Shadie toolkit, a GPU-based framework that allows for real-time interactive calculations for volume visualization. Current SBRT simulation practice consists of a serial CT acquisition for the assessment of inter- and intra-fractional motion utilizing patient specific immobilization systems. Shadie was used to visualize potential uncertainties, including RPL variance and changes in gastric content. Input for this procedure consisted of two patient CT sets, contours of the desired organ, and a pre-calculated dose. In this study, we performed rigid registrations between sets of 4DCT's obtained from a patient with varying setup conditions. Custom visualizations are written by the user in Shadie, permitting one to create color-coded displays derived from a calculation along each ray. Results: Serial CT data acquired on subsequent days was analyzed for variation in RPB and gastric content. Specific shaders were created to visualize clinically relevant features, including RPL (radiological path length) integrated up to organs of interest. Using pre-calculated dose distributions and utilizing segmentation masks as additional input allowed us to further refine the display output from Shadie and create tools suitable for clinical usage. Conclusion: We have demonstrated a method to visualize potential uncertainty for intrafractional proton radiotherapy. We believe this software could prove a useful tool to guide those looking to design treatment plans least insensitive to motion for patients undergoing proton SBRT in the GI tract.

60 APPLIED LIFE SCIENCES↗

The Radio and Optical Luminosity Evolution of Quasars II - The SDSS Sample

We determine the radio and optical luminosity evolutions and the true distribution of the radio loudness parameter R, defined as the ratio of the radio to optical luminosity, for a set of more than 5000 quasars combining SDSS optical and FIRST radio data. We apply the method of Efron and Petrosian to access the intrinsic distribution parameters, taking into account the truncations and correlations inherent in the data. We find that the population exhibits strong positive evolution with redshift in both wavebands, with somewhat greater radio evolution than optical. With the luminosity evolutions accounted for, we determine the density evolutions and local radio and optical luminosity functions. The intrinsic distribution of the radio loudness parameter R is found to be quite different than the observed one, and is smooth with no evidence of a bi-modality in radio loudness. The results we find are in general agreement with the previous analysis of Singal et al., 2011 which used POSS-I optical and FIRST radio data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗