Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Analysis of Organic Molecules Extracted from Mars Analogues and Influence of Their Mineralogy Using N-Methyl-N-(tert-butyldimethylsilyl)Trifluoroacetamide Derivatization Coupled with Gas Chromatography Mass Spectrometry in Preparation for the Sample Analysis at Mars Derivatization Experiment on the Mars Science Laboratory Mission

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids will require a chemical extraction and derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed, a one-pot extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment on the Mars Science Laboratory (MSL). The temperature and duration the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 C for several minutes of a variety of terrestrial Mars analogue materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analogue materials that contained high abundances of hydrated minerals and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA, The combination of pyrolysis and two different chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars,

Stalport, F.↗

AMINO ACID ANALYSES OF THE ANTARCTIC CM2 METEORITES ALH 83100 AND LEW 90500 USING LIQUID CHROMATOGRAPHY-TIME OF FLIGHT-MASS SPECTROMETRY

The investigation of organic compounds in primitive carbonaceous meteorites provides a record of the chemical processes that occurred in the early solar system. In particular, amino acids have been shown to be potential indicators in tracing the nature of carbonaceous chondrite parent bodies [ 13. The delivery of amino acids by carbonaceous chondrites to the early Earth could have been any important source of the Earth's prebiotic organic inventory [2]. Over 80 different amino acids have been detected in the Murchison CM2 meteorite, most of them completely non-existent in the terrestrial biosphere [3]. We have optimized a new liquid chromatography-time-of-flight-mass spectrometry (LC-ToF-MS) technique coupled with OPAMAC derivatization in order to detect amino acids in meteorite extracts by UV fluorescence and exact mass simultaneously. The detection limit of the LC-ToF-MS instrument for amino acids is at least 3 orders of magnitude lower than traditional GC-MS techniques. Here we report on the first analyses of amino acids and their enantiomeric abundances in the CM2 carbonaceous meteorites ALH 83100, LEW 90500, and Murchison using this new LC-ToF-MS instrument configuration. Amino acid analyses of any kind for the CM meteorite ALH 83100 have not previously been reported.

Glavin, D. P.↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Reactions of Atomic Thorium and Uranium Cations with SF 6 Studied by Guided Ion Beam Tandem Mass Spectrometry

The fundamental chemistry of the thorium and uranium fluorides continues to be an area of interest because of the use of thorium and uranium fluoride compounds in nuclear fuel systems. Here, we study the reaction of thorium cations with sulfur hexafluoride for the first time and revisit the reaction of uranium cations with sulfur hexafluoride. By using guided ion beam tandem mass spectrometry, we explore the reaction pathways that become accessible well above thermal energies (E ~ 0.04 eV). Overall, we find that both Th + and U + react very efficiently with SF 6 , approaching the collision limit at both thermal and elevated energies. Here, the primary products observed at low energies include Th 1–3 + , UF 1–4 + , and SF 1–4 + , all of which are formed in barrierless, exothermic processes. SF 5 + was also observed, although the pressure dependence of this channel reveals that SF 5 + forms exothermically through secondary reactions, which the energy dependences suggest result from reactions between ThF 2 + and UF 3 + with SF 6 . At higher energies, both AnF 3 + products are observed to decay to AnF + + F 2 and both SF 4 + and SF 2 + exhibit cross sections with endothermic features. For both systems, the rise in SF 4 + can be attributed to a secondary collision between AnF + with SF 6 on the basis of the pressure dependence of the SF 4 + channel at higher energies and the rise in SF 2 + appears to result from the decomposition of SF 3 + to SF 2 + + F.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

Mass Spectrometry Sample Submission Portal

Each step in the scientific process generates contextual information about the data that is important to consider when performing data integration, developing models of biological process, or training AI models. We will develop a flexible, template-driven tool that will log biological samples, capture metadata about those samples, and track the type(s) of analysis being performed by researchers providing samples for analysis by mass spectrometry.

97 MATHEMATICS AND COMPUTING↗

Lambda-PFLOTRAN 1.0: a workflow for incorporating organic matter chemistry informed by ultra high resolution mass spectrometry into biogeochemical modeling

Abstract. Organic matter (OM) composition plays a central role in microbial respiration of dissolved organic matter and subsequent biogeochemical reactions. Here, a direct connection of organic matter chemistry and thermodynamics to reactive transport simulators has been achieved through the newly developed Lambda-PFLOTRAN workflow tool that succinctly incorporates carbon chemistry data generated from Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) into reaction networks to simulate organic matter degradation and the resulting biogeochemistry. Lambda-PFLOTRAN is a Python-based workflow, executed through a Jupyter notebook interface, that digests raw FTICR-MS data, develops a representative reaction network based on substrate-explicit thermodynamic modeling (also termed lambda modeling due to its key thermodynamic parameter λ used therein), and completes a biogeochemical simulation with the open source, reactive flow and transport code PFLOTRAN. The workflow consists of the following five steps: configuration, thermodynamic (lambda) analysis, sensitivity analysis, parameter estimation, and simulation output and visualization. Two test cases are provided to demonstrate the functionality of the Lambda-PFLOTRAN workflow. The first test case uses laboratory incubation data of temporal oxygen depletion to fit lambda parameters (i.e., maximum utilization rate and microbial carrying capacity). A slightly more complex second test case fits multiple lambda formulation and soil organic matter release parameters to temporal greenhouse gas generation measured during a soil incubation. Overall, the Lambda-PFLOTRAN workflow facilitates upscaling by using molecular-scale characterization to inform biogeochemical processes occurring at larger scales.

58 GEOSCIENCES↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vaporization Studies of Olivine via Knudsen Effusion Mass Spectrometry

Olivine is the major mineral in the Earth's upper mantle occurring predominantly in igneous rocks and has been identified in meteorites, asteroids, the Moon and Mars. Among many other important applications in planetary and materials sciences, the thermodynamic properties of vapor species from olivine are crucial as input parameters in computational modelling of the atmospheres of hot, rocky exoplanets (lava planets). There are several weight loss studies of olivine vaporization in the literature and one Knudsen Effusion Mass Spectrometry (KEMS) study. In this study, we examine a forsterite-rich olivine (93% forsterite and 7% fayalite, Fo93Fa7) with KEMS to further understand its vaporization and thermodynamic properties.

Planetary atmospheres↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗

In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

Glavin, D. P.↗

Determination of 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and -furans at the part per trillion level in United States beef fat using high-resolution gas chromatography/high-resolution mass spectrometry

As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).

Benzofurans/analysis↗

An approach for broad molecular imaging of the root-soil interface via indirect matrix-assisted laser desorption/ionization mass spectrometry

Understanding of rhizospheric processes is limited by the need for imaging complex molecular transformations at relevant spatial scales within the root soil continuum. In this work, we demonstrate a method to enable this analysis by first extracting organic compounds from the rhizosphere onto a PVDF membrane while maintaining their 2D distribution. We then image the distribution of chemical compounds using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). This approach permitted us to visualize and identify compounds on the root surface and presumed root exudates in the rhizosphere. Within a 1.8 cm x 0.6 cm sampling area of a switchgrass rhizosphere, we could observe at least four chemically distinct zones. Using high performance Fourier transform ion cyclotron MS, we were able to accurately annotate numerous molecules co-localized to each of these zones.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing Families of Spectral Similarity Scores and Their Use Cases for Gas Chromatography–Mass Spectrometry Small Molecule Identification

Metabolomics provides a unique snapshot into the world of small molecules and the complex biological processes that govern the human, animal, plant, and environmental ecosystems encapsulated by the One Health modeling framework. However, this “molecular snapshot” is only as informative as the number of metabolites confidently identified within it. The spectral similarity (SS) score is traditionally used to identify compound(s) in mass spectrometry approaches to metabolomics, where spectra are matched to reference libraries of candidate spectra. Unfortunately, there is little consensus on which of the dozens of available SS metrics should be used. This lack of standard SS score creates analytic uncertainty and potentially leads to issues in reproducibility, especially as these data are integrated across other domains. In this work, we use metabolomic spectral similarity as a case study to showcase the challenges in consistency within just one piece of the One Health framework that must be addressed to enable data science approaches for One Health problems. Here, using a large cohort of datasets comprising both standard and complex datasets with expert-verified truth annotations, we evaluated the effectiveness of 66 similarity metrics to delineate between correct matches (true positives) and incorrect matches (true negatives). We additionally characterize the families of these metrics to make informed recommendations for their use. Our results indicate that specific families of metrics (the Inner Product, Correlative, and Intersection families of scores) tend to perform better than others, with no single similarity metric performing optimally for all queried spectra. This work and its findings provide an empirically-based resource for researchers to use in their selection of similarity metrics for GC-MS identification, increasing scientific reproducibility through taking steps towards standardizing identification workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Molecular Characterization of Organophosphorus Compounds in Wildfire Smoke Using 21-T Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry

Here, we present a detailed molecular characterization of organophosphorus compounds in ambient organic aerosol influenced by wildfire smoke. Biomass burning organic aerosol (BBOA) is an important source of phosphorus (P) to surface waters, where even a small imbalance in the P flux can lead to substantial effects on water quality, such as eutrophication, algal blooms, and oxygen depletion. We aimed to exploit the ultrahigh resolving power, mass accuracy, and sensitivity of Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS) to explore the molecular composition of an ambient BBOA sample collected downwind of Pacific Northwest wildfires. The 21-T FT-ICR MS yielded 10533 distinct formulae, which included molecular species comprising C, H, O, and P with or without N, i.e., organophosphorus compounds that have long been quantified in wildfire smoke but have not yet been characterized at the molecular level. The lack of detailed molecular characterization of organophosphorus compounds in BBOA is primarily due to their inherently low concentrations in aerosols and poor ionization efficiency in complex mixtures. We demonstrate that the exceptional sensitivity of the 21-T FT-ICR MS allows qualitative analysis of a previously uncharacterized fraction of BBOA without its selective concentration from the organic matrix, exemplifying the need for ultrahigh-resolution tools for a more detailed and accurate molecular depiction of such complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying molecules as biosignatures with assembly theory and mass spectrometry

The search for alien life is hard because we do not know what signatures are unique to life. We show why complex molecules found in high abundance are universal biosignatures and demonstrate the first intrinsic experimentally tractable measure of molecular complexity, called the molecular assembly index (MA). To do this we calculate the complexity of several million molecules and validate that their complexity can be experimentally determined by mass spectrometry. This approach allows us to identify molecular biosignatures from a set of diverse samples from around the world, outer space, and the laboratory, demonstrating it is possible to build a life detection experiment based on MA that could be deployed to extraterrestrial locations, and used as a complexity scale to quantify constraints needed to direct prebiotically plausible processes in the laboratory. Such an approach is vital for finding life elsewhere in the universe or creating de-novo life in the lab.

Stuart M. Marshall↗

Monitoring Trace Contaminants in Air Via Ion Trap Mass Spectrometry

Recent passage of the Clean Air Act with its stricter regulation of toxic gas emissions, and the ever-growing number of applications which require faster turnaround times between sampling and analysis are two major factors which are helping to drive the development of new instrument technologies for in-situ, on-line, real-time monitoring. The ion trap, with its small size, excellent sensitivity, and tandem mass spectrometry capability is a rapidly evolving technology which is well-suited for these applications. In this paper, we describe the use of a commercial ion trap instrument for monitoring trace levels of chlorofluorocarbons (CFCs) and volatile organic compounds (VOCs) in air. A number of sample introduction devices including a direct transfer line interface, short column GC, and a cryotrapping interface are employed to achieve increasing levels of sensitivity. MS, MS/MS, and MS/MS/MS methods are compared to illustrate trade-offs between sensitivity and selectivity. Filtered Noise Field (FNF) technology is found to be an excellent means for achieving lower detection limits through selective storage of the ion(s) of interest during ionization. Figures of merit including typical sample sizes, detection limits, and response times are provided. The results indicate the potential of these techniques for atmospheric assessments, the High Speed Research Program, and advanced life support monitoring applications for NASA.

Palmer, Peter T.↗