At least 469 records · Page 26

Waverider design for generalized shock geometries

A new design method for waverider configurations with generalized shock geometries is presented. A cross-stream Euler marching procedure is used to define the post-shock flow field, and an arbitrary 3D shock shape is specified as an input. This approach makes it possible to use nonaxisymmetric shock topologies with nonconstant shock strengths. The problem is reformulated in the proper curvilinear coordinate system to suppress its fundamental ill-posedness.

Jones, K. D.↗

Liquid propellant rocket engine combustion simulation with a time-accurate CFD method

Time-accurate computational fluid dynamics (CFD) algorithms are among the basic requirements as an engineering or research tool for realistic simulations of transient combustion phenomena, such as combustion instability, transient start-up, etc., inside the rocket engine combustion chamber. A time-accurate pressure based method is employed in the FDNS code for combustion model development. This is in connection with other program development activities such as spray combustion model development and efficient finite-rate chemistry solution method implementation. In the present study, a second-order time-accurate time-marching scheme is employed. For better spatial resolutions near discontinuities (e.g., shocks, contact discontinuities), a 3rd-order accurate TVD scheme for modeling the convection terms is implemented in the FDNS code. Necessary modification to the predictor/multi-corrector solution algorithm in order to maintain time-accurate wave propagation is also investigated. Benchmark 1-D and multidimensional test cases, which include the classical shock tube wave propagation problems, resonant pipe test case, unsteady flow development of a blast tube test case, and H2/O2 rocket engine chamber combustion start-up transient simulation, etc., are investigated to validate and demonstrate the accuracy and robustness of the present numerical scheme and solution algorithm.

Chen, Y. S.↗

Estimation of Sea Ice Thickness Distributions through the Combination of Snow Depth and Satellite Laser Altimetry Data

Combinations of sea ice freeboard and snow depth measurements from satellite data have the potential to provide a means to derive global sea ice thickness values. However, large differences in spatial coverage and resolution between the measurements lead to uncertainties when combining the data. High resolution airborne laser altimeter retrievals of snow-ice freeboard and passive microwave retrievals of snow depth taken in March 2006 provide insight into the spatial variability of these quantities as well as optimal methods for combining high resolution satellite altimeter measurements with low resolution snow depth data. The aircraft measurements show a relationship between freeboard and snow depth for thin ice allowing the development of a method for estimating sea ice thickness from satellite laser altimetry data at their full spatial resolution. This method is used to estimate snow and ice thicknesses for the Arctic basin through the combination of freeboard data from ICESat, snow depth data over first-year ice from AMSR-E, and snow depth over multiyear ice from climatological data. Due to the non-linear dependence of heat flux on ice thickness, the impact on heat flux calculations when maintaining the full resolution of the ICESat data for ice thickness estimates is explored for typical winter conditions. Calculations of the basin-wide mean heat flux and ice growth rate using snow and ice thickness values at the 70 m spatial resolution of ICESat are found to be approximately one-third higher than those calculated from 25 km mean ice thickness values.

Kurtz, Nathan T.↗

Ground Tests on the BOLT Geometry at Mach 7: Cross-Facility Comparison and Stability Analysis

Transition measurements have been obtained through two experimental campaigns conducted independently by the German Aerospace Center and the French Aerospace Lab with the French Alternative Energies and Atomic Energy Commission on subscale models of the BOLT-1 flight experiment geometry. This paper details a cross-facility comparison of measurements obtained at Mach 7, as well as subsequent computational analysis. Infrared (IR) thermography measurements obtained by both campaigns have facilitated a global comparison of the transition front across facilities at analagous conditions, which are found to be in good agreement. High-frequency surface pressure fluctuation data demonstrate significant amplification of instabilities with Mack-mode characteristics in the outboard regions of the acreage. These measurements are compared to stability analyses of varying fidelity. The computational methods employed to characterize the boundary-layer transition phenomena include the traditional line-marching implementation of the Parabolized Stability Equations (PSE), 2D eigenvalue analysis coupled with PSE, and Adaptive Mesh Refinement Wavepacket Tracking. While the 2D eigenvalue analysis is found to predict instabilities, which correlate in terms of frequency and acreage location to the experimental measurements, the predicted amplification for these instabilities is lower than would typically be expected for transition. Line-marching results for traveling crossflow produce the best match to the experimental transition front, with a consistent transition N factor of approximately 3-3.5.

Boundary Layer Transition↗

Solvent Hold Tank Sample Results for MCU-19-2-3-4 (January 2019), MCU-19-83-84-85 (February 2019), MCU-19-208-209-210 (March 2019) and MCU-19-138-139-140 (March special trim): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples (MCU-19-2-3-4, MCU-19-83-84-85, MCU-19-208-209-210); and a set from a special trim (MCU-19-138-139-140) are reported. Most of the conclusions are based on the March SHT sample (MCU-18-208-209-210). Analyses of the March SHT sample (MCU-19-208-209-210) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L, respectively) by 3% and 6%, respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has increased since the January 2019 measurement to 1141 mg/L, which is above the minimum recommended concentration (479 mg/L). These new concentrations are consistent with the concentrations observed when MCU was fully operational in 2016. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the January sample and consistently detected in the February and March samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the March SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.55E5 dpm/mL) measured in the March 2019 SHT samples was consistent with previous values observed when MCU was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias (a statistical difference at 5% level) between the FT-HNMR and HPLC methods when measuring the MaxCalix and Modifier concentration; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was also detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simple numerical method for predicting steady compressible flows

A numerical method for solving the isenthalpic form of the governing equations for compressible viscous and inviscid flows was developed. The method was based on the concept of flux vector splitting in its implicit form. The method was tested on several demanding inviscid and viscous configurations. Two different forms of the implicit operator were investigated. The time marching to steady state was accelerated by the implementation of the multigrid procedure. Its various forms very effectively increased the rate of convergence of the present scheme. High quality steady state results were obtained in most of the test cases; these required only short computational times due to the relative efficiency of the basic method.

Vonlavante, Ernst↗

Cumulative fade statistics and prediction methods associated with the COMSTAR beacon signal at 28.56 GHz

The paper presents cumulative fade statistics for the period April 1977 to March 1978 and reviews the rain attenuation predictive efforts using radar and disdrometer data for the summer of 1977. Attention is given to the receiving and radar systems as well as the disdrometer-raingage system. Discussion of the fade statistics covers the yearly, monthly and time of day statistics. Consideration is given to measured and predicted attenuation events, measured and predicted probability distributions as well as an empirical calibration adjustment. It is noted that in spite of many reasons for noncorrelation, the radar results do correlate well. Finally, it is concluded that the results demonstrate the utility of using radar coupled with disdrometer measurements for predicting individual fade events as well as long term fade distributions associated with satellite communications through rain.

Goldhirsh, J.↗

Predictors of Locoregional Failure and Impact on Overall Survival in Patients With Resected Exocrine Pancreatic Cancer

Purpose: Resection of exocrine pancreatic cancer is necessary for cure, but locoregional and distant relapse is common. We evaluated our institutional experience to better understand risk factors for locoregional failure (LRF) and its impact on overall survival (OS). Methods and Materials: We reviewed 1051 consecutive patients with nonmetastatic exocrine pancreatic cancer who underwent resection at our institution between March 1987 and January 2011. Among them, 458 had adequate follow-up and evaluation for study inclusion. All patients received adjuvant chemotherapy (n=80 [17.5%]) or chemoradiation therapy (n=378 [82.5%]). Chemotherapy and chemoradiation therapy most frequently consisted of 6 cycles of gemcitabine and 50.4 Gy in 28 fractions with concurrent 5-fluorouracil, respectively. Locoregional control (LRC) and OS were estimated with the Kaplan-Meier method. Univariate and multivariate analyses were performed with Cox proportional hazards regression models incorporating propensity score. Results: Median patient age was 64.5 years (range: 29-88 years). Median follow-up for living patients was 84 months (range: 6-300 months). Extent of resection was R0 (83.8%) or R1 (16.2%). Overall crude incidence of LRF was 17% (n=79). The 5-year LRC for patients with and without radiation therapy was 80% and 68%, respectively (P=.003; hazard ratio [HR]: 0.45; 95% confidence interval [CI]: 0.28-0.76). Multivariate analysis, incorporating propensity score, indicated radiation therapy (P<.0001; HR: 0.23; 95% CI: 0.12-0.42) and positive lymph node ratio of ≥0.2 (P=.02; HR: 1.78; 95% CI: 1.10-2.9) were associated with LRC. In addition, LRF was associated with worse OS (P<.0001; HR: 5.0; 95% CI: 3.9-6.3). Conclusions: In our analysis of 458 patients with resected pancreatic cancer, positive lymph node ratio of ≥0.2 and no adjuvant chemoradiation therapy were associated with increased LRF risk. LRF was associated with poor OS. Radiation therapy should be considered as adjuvant locoregional treatment following pancreatic cancer resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Determination of Heavy Metal Contamination in Horse Mackerel and Whiting Caught in the Sea of Marmara

In this study, the concentrations of lead, cadmium and manganese were determined in horse mackerel (Trachurus mediterraneus) and whiting (Merlangius merlangus euxinus) that were caught in the Sea of Marmara. These are commonly consumed fish species in this region. Fish were provided by a fishermen quarterly between March 2013 and December 2013 and, separated according to size (small, medium and large). Pb(II), Cd(II) and Mn(II) levels were determined using the wet digestion method by Graphite furnace atomic atomic absorption spectrophotometer. According to this study, for horse mackerel, the highest concentration of lead, cadmium, and manganese was 6.69 µg kg{sup −1} (September), 5.24 µg kg{sup −1} (March) and 9.24 µg kg{sup −1} (June), respectively. For whiting, the highest concentration of lead, cadmium, and manganese was 2.25 µg kg{sup −1} (June), 0.263 µg kg{sup −1} (September) and 10.4 µg kg{sup −1} (June), respectively. These heavy metal levels in fish were found to be acceptable for human consumption according to World Health Organization border values.

54 ENVIRONMENTAL SCIENCES↗

Radiation Exposure in Biliary Procedures Performed to Manage Anastomotic Strictures in Pediatric Liver Transplant Recipients: Comparison Between Radiation Exposure Levels Using an Image Intensifier and a Flat-Panel Detector-Based System

Purpose: The aim of this study was to estimate radiation exposure in pediatric liver transplants recipients who underwent biliary interventional procedures and to compare radiation exposure levels between biliary interventional procedures performed using an image intensifier-based angiographic system (IIDS) and a flat panel detector-based interventional system (FPDS). Materials and Methods: We enrolled 34 consecutive pediatric liver transplant recipients with biliary strictures between January 2008 and March 2013 with a total of 170 image-guided procedures. The dose-area product (DAP) and fluoroscopy time was recorded for each procedure. The mean age was 61 months (range 4-192), and mean weight was 17 kg (range 4-41). The procedures were classified into three categories: percutaneous transhepatic cholangiography and biliary catheter placement (n = 40); cholangiography and balloon dilatation (n = 55); and cholangiography and biliary catheter change or removal (n = 75). Ninety-two procedures were performed using an IIDS. Seventy-eight procedures performed after July 2010 were performed using an FPDS. The difference in DAP between the two angiographic systems was compared using Wilcoxon rank-sum test and a multiple linear regression model. Results: Mean DAP in the three categories was significantly greater in the group of procedures performed using the IIDS compared with those performed using the FPDS. Statistical analysis showed a p value = 0.001 for the PTBD group, p = 0.0002 for the cholangiogram and balloon dilatation group, and p = 0.00001 for the group with cholangiogram and biliary catheter change or removal. Conclusion: In our selected cohort of patients, the use of an FPDS decreases radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinicians’ and Pharmacists’ Reported Implementation of Vaccination Practices for Adults

Introduction: Despite the proven effectiveness of immunization in preventing morbidity and mortality, adult vaccines remain underutilized. The objective of this study was to describe clinicians’ and pharmacists’ self-reported implementation of the Standards for Adult Immunization Practice (“the Standards”; i.e., routine assessment, recommendation, and administration/referral for needed vaccines, and documentation of administered vaccines, including in immunization information systems). Methods: Two Internet panel surveys (one among clinicians and one among pharmacists) were conducted during February–March 2017 and asked respondents about their practice’s implementation of the Standards. T-tests assessed associations between clinician medical specialty, vaccine type, and each component of the Standards (March–August 2017). Results: Implementation of the Standards varied substantially by vaccine and provider type. For example, >80.0% of providers, including obstetrician/gynecologists and subspecialists, assessed for and recommended influenza vaccine. However, 24.3% of obstetrician/gynecologists and 48.9% of subspecialists did not stock influenza vaccine for administration. Although zoster vaccine was recommended by >89.0% of primary care providers, <58.0% stocked the vaccine; by contrast, 91.6% of pharmacists stocked zoster vaccine. Vaccine needs assessments, recommendations, and stocking/referrals also varied by provider type for pneumococcal; tetanus, diphtheria, acellular pertussis; tetanus diphtheria; human papillomavirus; and hepatitis B vaccines. Conclusions: This report highlights gaps in access to vaccines recommended for adults across the spectrum of provider specialties. Greater implementation of the Standards by all providers could improve adult vaccination rates in the U.S. by reducing missed opportunities to recommend vaccinations and either vaccinate or refer patients to vaccine providers.

60 APPLIED LIFE SCIENCES↗

Quality of Life After Palliative Radiation Therapy for Patients With Painful Bone Metastases: Results of an International Study Validating the EORTC QLQ-BM22

Purpose: Radiation therapy (RT) is an effective method of palliating painful bone metastases and can improve function and reduce analgesic requirements. In advanced cancer patients, quality of life (QOL) is the primary outcome of interest over traditional endpoints such as survival. The purpose of our study was to compare bone metastasis-specific QOL scores among patients who responded differently to palliative RT. Methods and Materials: Patients receiving RT for bone metastases across 6 countries were prospectively enrolled from March 2010-January 2011 in a trial validating the QLQ-BM22 and completed the QLQ-BM22 and the core measure (QLQ-C30) at baseline and after 1 month. Pain scores and analgesic intake were recorded, and response to RT was determined according to the latest published guidelines. The Kruskal-Wallis nonparametric and Wilcoxon rank sum tests compared changes in QOL among response groups. A Bonferroni-adjusted P<.003 indicated statistical significance. Results: Of 79 patients who received palliative RT, 59 were assessable. Partial response, pain progression, and indeterminate response were observed in 22, 8, and 29 patients, respectively; there were no patients with a complete response. Patients across all groups had similar baseline QOL scores apart from physical functioning (patients who progressed had better initial functioning). One month after RT, patients who responded had significant improvements in 3 of 4 QLQ-BM22 domains (painful site, P<.0001; painful characteristic, P<.0001; and functional interference, P<.0001) and 3 QLQ-C30 domains (physical functioning, P=.0006; role functioning, P=.0026; and pain, P<.0001). Patients with progression in pain had significantly worse functional interference (P=.0007) and pain (P=.0019). Conclusions: Patients who report pain relief after palliative RT also have better QOL with respect to bone metastasis-specific issues. The QLQ-BM22 and QLQ-C30 are able to discriminate among patients with varying responses and are recommended for use in future bone metastasis clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns and Timing of Failure for Diffuse Large B-Cell Lymphoma After Initial Therapy in a Cohort Who Underwent Autologous Bone Marrow Transplantation for Relapse

Purpose: To evaluate the location and timing of initial recurrence in patients with diffuse large B-cell lymphoma (DLBCL) who subsequently underwent high-dose chemotherapy with autologous stem cell transplant (HDC/ASCT), to direct approaches for disease surveillance, elucidate the patterns of failure of contemporary treatment strategies, and guide adjuvant treatment decisions. Methods and Materials: We analyzed consecutive patients with DLBCL who underwent HDC/ASCT between May 1992 and March 2014 at our institution. Of the 187 evaluable patients, 8 had incomplete data, and 79 underwent HDC/ASCT as a component of initial treatment for de novo or refractory DLBCL and were excluded from further analysis. Results: The median age was 50.8 years; the median time to relapse was 1.3 years. Patients were segregated according to the initial stage at diagnosis, with early stage (ES) defined as stage I/II and advanced stage (AS) defined as stage III/IV. In total, 40.4% of the ES and 75.5% of the AS patients relapsed in sites of initial disease; 68.4% of those with ES disease and 75.0% of those with AS disease relapsed in sites of initial disease only. Extranodal relapses were common (44.7% in ES and 35.9% in AS) and occurred in a variety of organs, although gastrointestinal tract/liver (n=12) was most frequent. Conclusions: Most patients with DLBCL who relapse and subsequently undergo HDC/ASCT initially recur in the previously involved disease site(s). Time to recurrence is brief, suggesting that frequency of screening is most justifiably greatest in the early posttherapy years. © 2016 Elsevier Inc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IS FLUX ROPE A NECESSARY CONDITION FOR THE PROGENITOR OF CORONAL MASS EJECTIONS?

A magnetic flux rope structure is believed to exist in most coronal mass ejections (CMEs). However, it has been long debated whether the flux rope exists before eruption or if it is formed during eruption via magnetic reconnection. The controversy has continued because of our lack of routine measurements of the magnetic field in the pre-eruption structure, such as solar filaments. However, recently an indirect method was proposed to infer the magnetic field configuration based on the sign of helicity and the bearing direction of the filament barbs. In this paper, we apply this method to two erupting filament events, one on 2014 September 2 and the other on 2011 March 7, and find that the first filament is supported by a magnetic flux rope and the second filament is supported by a sheared arcade, i.e., the first one is an inverse-polarity filament and the second one is a normal-polarity filament. With the identification of the magnetic configurations in these two filaments, we stress that a flux rope is not a necessary condition for the pre-CME structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Property Retrieval Products for Graciosa Island, Azores

The motivation for developing this product was to use the Dong et al. 1998 method to retrieve cloud microphysical properties, such as cloud droplet effective radius, cloud droplets number concentration, and optical thickness. These retrieved properties have been used to validate the satellite retrieval, and evaluate the climate simulations and reanalyses. We had been using this method to retrieve cloud microphysical properties over ARM SGP and NSA sites. We also modified the method for the AMF at Shouxian, China and some IOPs, e.g. ARM IOP at SGP in March, 2000. The ARSCL data from ARM data archive over the SGP and NSA have been used to determine the cloud boundary and cloud phase. For these ARM permanent sites, the ARSCL data was developed based on MMCR measurements, however, there were no data available at the Azores field campaign. We followed the steps to generate this derived product and also include the MPLCMASK cloud retrievals to determine the most accurate cloud boundaries, including the thin cirrus clouds that WACR may under-detect. We use these as input to retrieve the cloud microphysical properties. Due to the different temporal resolutions of the derived cloud boundary heights product and the cloud properties product, we submit them as two separate netcdf files.

54 ENVIRONMENTAL SCIENCES↗

Development of upwind schemes for the Euler equations

Described are many algorithmic and computational aspects of upwind schemes and their second-order accurate formulations based on Total-Variation-Diminishing (TVD) approaches. An operational unification of the underlying first-order scheme is first presented encompassing Godunov's, Roe's, Osher's, and Split-Flux methods. For higher order versions, the preprocessing and postprocessing approaches to constructing TVD discretizations are considered. TVD formulations can be used to construct relaxation methods for unfactored implicit upwind schemes, which in turn can be exploited to construct space-marching procedures for even the unsteady Euler equations. A major part of the report describes time- and space-marching procedures for solving the Euler equations in 2-D, 3-D, Cartesian, and curvilinear coordinates. Along with many illustrative examples, several results of efficient computations on 3-D supersonic flows with subsonic pockets are presented.

Chakravarthy, Sukumar R.↗

A user guide for the EMTAC-MZ CFD code

The computer code (EMTAC-MZ) was applied to investigate the flow field over a variety of very complex three-dimensional (3-D) configurations across the Mach number range (subsonic, transonic, supersonic, and hypersonic flow). In the code, a finite volume, multizone implementation of high accuracy, total variation diminishing (TVD) formulation (based on Roe's scheme) is used to solve the unsteady Euler equations. In the supersonic regions of the flow, an infinitely large time step and a space-marching scheme is employed. A finite time step and a relaxation or 3-D approximate factorization method is used in subsonic flow regions. The multizone technique allows very complicated configurations to be modeled without geometry modifications, and can easily handle combined internal and external flow problems. An elliptic grid generation package is built into the EMTAC-MZ code. To generate the computational grid, only the surface geometry data are required. Results obtained for a variety of configurations, such as fighter-like configurations (F-14, AVSTOL), flow through inlet, multi-bodies (shuttle with external tank and SRBs), are reported and shown to be in good agreement with available experimental data.

Szema, Kuo-Yen↗

The large discretization step method for time-dependent partial differential equations

A new method for the acceleration of linear and nonlinear time dependent calculations is presented. It is based on the Large Discretization Step (LDS) approximation, defined in this work, which employs an extended system of low accuracy schemes to approximate a high accuracy discrete approximation to a time dependent differential operator. Error bounds on such approximations are derived. These approximations are efficiently implemented in the LDS methods for linear and nonlinear hyperbolic equations, presented here. In these algorithms the high and low accuracy schemes are interpreted as the same discretization of a time dependent operator on fine and coarse grids, respectively. Thus, a system of correction terms and corresponding equations are derived and solved on the coarse grid to yield the fine grid accuracy. These terms are initialized by visiting the fine grid once in many coarse grid time steps. The resulting methods are very general, simple to implement and may be used to accelerate many existing time marching schemes.