Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASUREMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Long-term measurements of submicrometer aerosol chemistry at the Southern Great Plains (SGP) using an Aerosol Chemical Speciation Monitor (ACSM)

In this study the long-term trends of non-refractory submicrometer aerosol (NR-PM1) composition and mass concentration measured by an Aerosol Chemical Speciation Monitor (ACSM) at the Atmospheric Radiation Measurement (ARM) program's Southern Great Plains (SGP) site are discussed. NR-PM1 data was recorded at ~30 min intervals over a period of 19 months between November 2010 and June 2012. Positive Matrix Factorization (PMF) was performed on the measured organic mass spectral matrix using a rolling window technique to derive factors associated with distinct sources, evolution processes, and physiochemical properties. The rolling window approach also allows us to capture the dynamic variations of the chemical properties in the organic aerosol (OA) factors over time. Three OA factors were obtained including two oxygenated OA (OOA) factors, differing in degrees of oxidation, and a biomass burning OA (BBOA) factor. Back trajectory analyses were performed to investigate possible sources of major NR-PM1 species at the SGP site. Organics dominated NR-PM1 mass concentration for the majority of the study with the exception of winter, when ammonium nitrate increases due to transport of precursor species from surrounding urban and agricultural areas and also due to cooler temperatures. Sulfate mass concentrations have little seasonal variation with mixed regional and local sources. In the spring BBOA emissions increase and are mainly associated with local fires. Isoprene and carbon monoxide emission rates were obtained by the Model of Emissions of Gases and Aerosols from Nature (MEGAN) and the 2011 U.S. National Emissions Inventory to represent the spatial distribution of biogenic and anthropogenic sources, respectively. The combined spatial distribution of isoprene emissions and air mass trajectories suggest that biogenic emissions from the southeast contribute to SOA formation at the SGP site during the summer.

54 ENVIRONMENTAL SCIENCES↗

Agreement Between Institutional Measurements and Treatment Planning System Calculations for Basic Dosimetric Parameters as Measured by the Imaging and Radiation Oncology Core-Houston

Purpose: To compare radiation machine measurement data collected by the Imaging and Radiation Oncology Core at Houston (IROC-H) with institutional treatment planning system (TPS) values, to identify parameters with large differences in agreement; the findings will help institutions focus their efforts to improve the accuracy of their TPS models. Methods and Materials: Between 2000 and 2014, IROC-H visited more than 250 institutions and conducted independent measurements of machine dosimetric data points, including percentage depth dose, output factors, off-axis factors, multileaf collimator small fields, and wedge data. We compared these data with the institutional TPS values for the same points by energy, class, and parameter to identify differences and similarities using criteria involving both the medians and standard deviations for Varian linear accelerators. Distributions of differences between machine measurements and institutional TPS values were generated for basic dosimetric parameters. Results: On average, intensity modulated radiation therapy–style and stereotactic body radiation therapy–style output factors and upper physical wedge output factors were the most problematic. Percentage depth dose, jaw output factors, and enhanced dynamic wedge output factors agreed best between the IROC-H measurements and the TPS values. Although small differences were shown between 2 common TPS systems, neither was superior to the other. Parameter agreement was constant over time from 2000 to 2014. Conclusions: Differences in basic dosimetric parameters between machine measurements and TPS values vary widely depending on the parameter, although agreement does not seem to vary by TPS and has not changed over time. Intensity modulated radiation therapy–style output factors, stereotactic body radiation therapy–style output factors, and upper physical wedge output factors had the largest disagreement and should be carefully modeled to ensure accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple correction for the sample shape and radial offset effects on SQUID magnetometers: Magnetic measurements on Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er) standards

An increased focus on magnetic measurements of oriented single crystals, thin films, and magnetically dilute systems has led to a demand for the measurement of weak magnetic moments. This level of sensitivity and precision can be achieved on SQUID magnetometers by decreasing the size of the detection coils. However, the smaller detection coils can amplify two errors in the magnitude of the measured moment, the sample shape and radial offset effects, which were small and typically unaccounted for on previous magnetometers. We report a simple method to determine the radial offset of a sample by taking advantage of the two basic scan modes, DC and lock-in, typically used on magnetometers. This technique allows for the correction of the sample shape and radial offset effects in order to obtain the true moment of a sample. To show the efficacy of this technique, we report the magnetic properties of Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er). - Graphical abstract: Correction for the sample shape and radial offset effects on SQUID magnetometers using a combination of DC and VSM scan data. - Highlights: • Sample shape and radial offset effects alter the moment measured by magnetometers. • We present a simple method to correct for these sample effects on magnetometers. • We measure magnetic susceptibilities of Ln{sub 2}O{sub 3} to show the efficacy of this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct optical band gap measurement in polycrystalline semiconductors: A critical look at the Tauc method

The direct optical band gap of semiconductors is traditionally measured by extrapolating the linear region of the square of the absorption curve to the x-axis, and a variation of this method, developed by Tauc, has also been widely used. The application of the Tauc method to crystalline materials is rooted in misconception–and traditional linear extrapolation methods are inappropriate for use on degenerate semiconductors, where the occupation of conduction band energy states cannot be ignored. A new method is proposed for extracting a direct optical band gap from absorption spectra of degenerately-doped bulk semiconductors. This method was applied to pseudo-absorption spectra of Sn-doped In{sub 2}O{sub 3} (ITO)—converted from diffuse-reflectance measurements on bulk specimens. The results of this analysis were corroborated by room-temperature photoluminescence excitation measurements, which yielded values of optical band gap and Burstein–Moss shift that are consistent with previous studies on In{sub 2}O{sub 3} single crystals and thin films. - Highlights: • The Tauc method of band gap measurement is re-evaluated for crystalline materials. • Graphical method proposed for extracting optical band gaps from absorption spectra. • The proposed method incorporates an energy broadening term for energy transitions. • Values for ITO were self-consistent between two different measurement methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of the chiral magnetic effect with background isolation in 200 GeV Au+Au collisions at STAR

Using two novel methods, pair invariant mass (m inv ) and comparative measurements with respect to reaction plane (Ψ RP ) and participant plane (Ψ PP ), we isolate the possible chiral magnetic effect (CME) from backgrounds in 200 GeV Au+Au collisions at STAR. The invariant mass method identifies the resonance background contributions, coupled with the elliptic flow (ν 2 ), to the charge correlator CME observable (Δγ). At high mass (m inv > 1.5 GeV/c 2 ) where resonance contribution is small, we obtain the average Δγ magnitude. In the low mass region (m inv > 1.5 GeV/c 2 ), resonance peaks are observed in Δγ(m inv ). An event shape engineering (ESE) method is used to model the background shape in m inv to extract the potential CME signal at low m inv . In the comparative method, the Ψ RP is assessed by spectator neutrons measured by the ZDCs, and the Ψ PP by the 2 nd -harmonic event plane measured by the TPC. The ν 2 is stronger along Ψ PP and weaker along Ψ RP ; in contrast, the magnetic field, mainly from spectator protons, is weaker along Ψ PP and stronger along Ψ RP . As a result, the Δγ measured with respect to Ψ RP and Ψ PP contain different amounts of CME and background, and can thus determine these two contributions. It is found that the possible CME signals with background isolation by these two novel methods are small, on the order of a few percent of the inclusive Δγ measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-level measuring techniques for neutrons: High accuracy neutron source strength determination and fluence rate measurement at an underground laboratory

We report on measuring techniques for neutrons that have been developed at the Physikalisch-Technische Bundesanstalt (PTB), the German National Metrology Institute. PTB has characterized radioactive sources used in the BOREXINO and XENON100 experiments. For the BOREXINO experiment, a {sup 228}Th gamma radiation source was required which would not emit more than 10 neutrons per second. The determination of the neutron emission rate of this specially designed {sup 228}Th source was challenging due to the low neutron emission rate and because the ratio of neutron to gamma radiation was expected to be extremely low, of the order of 10{sup −6}. For the XENON100 detector, PTB carried out a high accuracy measurement of the neutron emission rate of an AmBe source. PTB has also done measurements in underground laboratories. A two month measurement campaign with a set of {sup 3}He-filled proportional counters was carried out in PTB's former UDO underground laboratory at the Asse salt mine. The aim of the campaign was to determine the intrinsic background of detectors, which is needed for the analysis of data taken in lowintensity neutron fields. At a later time, PTB did a preliminary measurement of the neutron fluence rate at the underground laboratory Felsenkeller operated by VKTA. By taking into account data from UDO, Felsenkeller, and detector calibrations made at the PTB facility, it was possible to estimate the neutron fluence rate at the Felsenkeller underground laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

Quantum state tomography with fully symmetric measurements and product measurements

We introduce random-matrix theory to study the tomographic efficiency of a wide class of measurements constructed out of weighted 2-designs, including symmetric informationally complete (SIC) probability operator measurements (POMs). In particular, we derive analytic formulas for the mean Hilbert-Schmidt distance and the mean trace distance between the estimator and the true state, which clearly show the difference between the scaling behaviors of the two error measures with the dimension of the Hilbert space. We then prove that the product SIC POMs, the multipartite analog of the SIC POMs, are optimal among all product measurements in the same sense as the SIC POMs are optimal among all joint measurements. We further show that, for bipartite systems, there is only a marginal efficiency advantage of the joint SIC POMs over the product SIC POMs. In marked contrast, for multipartite systems, the efficiency advantage of the joint SIC POMs increases exponentially with the number of parties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the neutrino neutral-current elastic differential cross section on mineral oil at E{sub {nu}{approx}1} GeV

We report a measurement of the flux-averaged neutral-current elastic differential cross section for neutrinos scattering on mineral oil (CH{sub 2}) as a function of four-momentum transferred squared, Q{sup 2}. It is obtained by measuring the kinematics of recoiling nucleons with kinetic energy greater than 50 MeV which are readily detected in MiniBooNE. This differential cross-section distribution is fit with fixed nucleon form factors apart from an axial mass M{sub A} that provides a best fit for M{sub A}=1.39{+-}0.11 GeV. Using the data from the charged-current neutrino interaction sample, a ratio of neutral-current to charged-current quasielastic cross sections as a function of Q{sup 2} has been measured. Additionally, single protons with kinetic energies above 350 MeV can be distinguished from neutrons and multiple nucleon events. Using this marker, the strange quark contribution to the neutral-current axial vector form factor at Q{sup 2}=0, {Delta}s, is found to be {Delta}s=0.08{+-}0.26.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring $CP$ violation in $h$ → $τ$ + $τ$ – at colliders

We investigate the LHC and Higgs Factory prospects for measuring the CP phase in the Higgs-tau-tau coupling. Currently this phase can be anywhere between 0° (CP even) and 90° (CP odd). A new, ideal observable is identified from an analytic calculation for the τ ± → ρ ± ν → π ± π 0 ν channel. It is demonstrated to have promising sensitivity at the LHC and superior sensitivity at the ILC compared to previous proposals. Furthermore, our observable requires the reconstruction of the internal substructure of decaying taus but does not rely on measuring the impact parameter of tau decays. It is the first proposal for such a measurement at the LHC. For the 14 TeV LHC, we estimate that about 1 ab –1 data can discriminate CP-even versus CP-odd at the 5σ level. With 3 ab –1 , the CP phase should be measurable to an accuracy of ~11°. At an e + e – Higgs Factory, we project that a 250 GeV run with 1 ab –1 luminosity can measure the phase to ~4.4° accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the t t ¯ production cross section in the τ + jets final state in p p collisions at s = 8 TeV using the ATLAS detector

A measurement of the inclusive p p → t $\bar{t}$ + X production cross section in the τ + jets final state using only the hadronic decays of the τ lepton is presented. The measurement is performed using 20.2 fb -1 of proton-proton collision data recorded at a center-of-mass energy of √ s = 8 TeV with the ATLAS detector at the Large Hadron Collider. The cross section is measured via a counting experiment by imposing a set of selection criteria on the identification and kinematic variables of the reconstructed particles and jets, and on event kinematic variables and characteristics. The production cross section is measured to be σ t $\bar{t}$ = 239 ± 29 pb , which is in agreement with the measurements in other final states and the theoretical predictions at this center-of-mass energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Measurement of the Mass Difference between Top and Antitop Quarks

We present a measurement of the mass difference between t and t quarks in lepton+jets final states of tt events in 1 fb{sup -1} of data collected with the D0 detector from Fermilab Tevatron Collider pp collisions at sq root(s)=1.96 TeV. The measured mass difference of 3.8+-3.7 GeV is consistent with the equality of t and t masses. This is the first direct measurement of a mass difference between a quark and its antiquark partner.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of Charged Pion and Kaon Differential Cross Sections in e + e - Annihilation at s = 10.52 GeV

Measurements of inclusive differential cross sections for charged pion and kaon production in e + e - annihilation have been carried out at a center-of-mass energy of s = 10.52 GeV . The measurements were performed with the Belle detector at the KEKB e + e - collider using a data sample containing 113 × 10 6 e + e - → q q ¯ events, where q = { u , d , s , c } . We present charge-integrated differential cross sections d σ h ± / d z for h ± = { π ± , K ± } as a function of the relative hadron energy z = 2 E h / s from 0.2 to 0.98. The combined statistical and systematic uncertainties for π ± ( K ± ) are 4% (4%) at z ~ 0.6 and 15% (24%) at z ~ 0.9 . The cross sections are the first measurements of the z dependence of pion and kaon production for z > 0.7 as well as the first precision cross section measurements at a center-of-mass energy far below the Z 0 resonance used by the experiments at LEP and SLC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗