Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNPX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

458 records · Page 26

Using Nuclear Resonance Fluorescence for Nondestructive Isotopic Analysis

Nuclear resonance fluorescence (NRF) has been studied as one of the nondestructive analysis (NDA) techniques currently being investigated by a multi-laboratory collaboration for the determination of Pu mass in spent fuel. In NRF measurements specific isotopes are identified by their characteristic lines in recorded gamma spectra. The concentration of an isotope in a material can be determined from measured NRF signal intensities if NRF cross sections and assay geometries are known. The potential of NRF to quantify isotopic content and Pu mass in spent fuel has been studied. The addition of NRF data to MCNPX and an improved treatment of the elastic photon scattering at backward angles has enabled us to more accurately simulate NRF measurements on spent fuel assemblies. Using assembly models from the spent fuel assembly library generated at LANL, NRF measurements are simulated to find the best measurement configurations, and to determine measurement sensitivities and times, and photon source and gamma detector requirements. A first proof-of-principal measurement on a mock-up assembly with a bremsstrahlung photon source demonstrated isotopic sensitivity to approximately 1% limited by counting statistics. Data collection rates are likely a limiting factor of NRF-based measurements of fuel assemblies but new technological advances may lead to drastic improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of self-interrogation neutron resonance densitometry (SINRD) to measure U-235 and Pu-239 content in a PWR spent fuel assembly

The use of Self-Interrogation Neutron Resonance Densitometry (SINRD) to measure the {sup 235}U and {sup 239}Pu content in a PWR spent fuel assembly was investigated via Monte Carlo N-Particle eXtended transport code (MCNPX) simulations. The sensitivity of SINRD is based on using the same fissile materials in the fission chambers as are present in the fuel because the effect of resonance absorption lines in the transmitted flux is amplified by the corresponding (n, f) reaction peaks in fission chamber. These simulations utilize the {sup 244}Cm spontaneous fission neutrons to self-interrogate the fuel pins. The amount of resonance absorption of these neutrons in the fuel can be measured using {sup 235}U and {sup 239}Pu fission chambers placed adjacent to the assembly. We used ratios of different fission chambers to reduce the sensitivity of the measurements to extraneous material present in fuel. The development of SINRD to measure the fissile content in spent fuel is of great importance to the improvement of nuclear safeguards and material accountability. Future work includes the use of this technique to measure the fissile content in FBR spent fuel and heavy metal product from reprocessing methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental investigation of new neutron moderator materials

In this study we present experimental investigation of thermal neutron energy spectra produced by lead and bismuth hydroxides (Pb(OH){sub 2}, and Bi(OH){sub 3}). The experimental energy spectra are compared with a thermal neutron energy spectrum of water measured in the same geometry. We present an MCNPX geometry model used to help with the experimental data interpretation. We demonstrate a very good reproduction of the experimental thermal neutron energy spectrum produced by the water moderator. We show a sensitivity study with the Pb(OH){sub 2}, and Bi(OH){sub 3} materials on different combinations of thermal neutron scattering kernels.

43 PARTICLE ACCELERATORS↗

Plutonium measurements with a fast-neutron multiplicity counter for nuclear safeguards applications

Measurements were performed at the Joint Research Centre in Ispra, Italy to field test a fast-neutron multiplicity counter developed at the University of Michigan. The measurements allowed the assessment of the system's photon discrimination abilities, efficiency when measuring neutron multiplicity, ability to characterize 240 Pu eff mass, and performance relative to a currently deployed neutron coincidence counter. We describe how this work is motivated by the need to replace and improve upon 3 He neutron detection systems for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Actinide destruction and power peaking analysis in a 1000 MWt advanced burner reactor using moderated heterogeneous target assemblies

The purpose of this research was to determine the effect of moderated heterogeneous subassemblies located in the core of a sodium-cooled fast reactor on minor actinide (MA) destruction rates over the lifecycle of the core. Additionally, particular emphasis was placed on the power peaking of the pins and the assemblies with the moderated targets as compared to standard unmoderated heterogeneous targets and a core without MA targets present. Power peaking analysis was performed on the target assemblies and on the fuel assemblies adjacent to the targets. The moderated subassemblies had a marked improvement in the overall destruction of heavy metals in the targets. The design with acceptable power peaking results had a 12.25% greater destruction of heavy metals than a similar ex-core unmoderated assembly. The increase in minor actinide destruction was most evident with americium where the moderated assemblies reduced the initial amount to less than 3% of the initial loading over a period of five years core residency. In order to take advantage of the high minor actinide destruction and minimize the power peaking effects, a hybrid scenario was devised where the targets resided ex-core in a moderated assembly for the first 506.9 effective full power days (EFPDs) and were moved to an in-core arrangement with the moderated targets removed for the remainder of the lifecycle. The hybrid model had an assembly and pin power peaking of less than 2.0 and a higher heavy metal and minor actinide destruction rate than the standard unmoderated heterogeneous targets either in-core or ex-core. The hybrid model has a 54.5% greater Am reduction over the standard ex-core model. It also had a 27.8% greater production of Cm and a 41.5% greater production of Pu than the standard ex-core model. The radiotoxicity of the targets in the hybrid design was 20% less than the discharged standard ex-core targets.

99 GENERAL AND MISCELLANEOUS↗

Defining Processing Times for Accelerator Produced 225Ac and Other Isotopes from Proton Irradiated Thorium

During the purification of radioisotopes, decay periods or time dependent purification steps may be required to achieve a certain level of radiopurity in the final product. Actinum-225 (Ac-225), Silver-111 (Ag-111), Astatine-211 (At-211), Ruthenium-105 (Ru-105), and Rhodium-105 (Rh-105) are produced in a high energy proton irradiated thorium target. Experimentally measured cross sections, along with MCNP6-generated cross sections, were used to determine the quantities of Ac-225, Ag-111, At-211, Ru-105, Rh-105, and other co-produced radioactive impurities produced in a proton irradiated thorium target at Brookhaven Linac Isotope Producer (BLIP). Ac-225 and Ag-111 can be produced with high radiopurity by the proton irradiation of a thorium target at BLIP.

07 ISOTOPE AND RADIATION SOURCES↗

Proton induced activation in mercury: Comparison of measurements and calculations

Measurements and simulations of the proton beam interaction with the mercury target were performed to support Spallation Neutron Source design. Due to the abundance of isotopes produced in mercury, the long delay between the irradiation and the measurements, and the self-shielding of the mercury sample, the measurements were difficult to perform and the activities of several isotopes have large uncertainties. Calculations predicted the activities of the most reliably measured isotopes within 20%/40%; however, some large discrepancies were observed for some isotopes for which the measurements were considered less reliable. Predicted dose rates were in very good agreement with the measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗