Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Research in particles and fields

Research activities in Cosmic Rays Gamma Rays, and Astrophysical Plasmas are covered The investigation of the astrophysical aspects of cosmic rays and gamma rays and of the radiation and electromagnetic field environment of the Earth and other planets are studied. These investigations are carried ut by means of energetic particle and photon detector systems flown on spacecraft and balloons. The emphasis is on precision measurements with high resolution in charge mass and energy. An extensive bibliography is given.

Stone, E. C.↗

Superconducting techniques for gravity survey and inertial navigation

A three-axis gravity gradiometer is developed, in which the magnetic fields produced by persistent currents are modulated by motions of superconducting proof masses. The common-acceleration-induced errors are compensated for by a six-axis superconducting accelerometer with a single magnetically levitated proof mass, linear acceleration resolution of 4 x 10 to the -12th m/(s exp 2 Hz exp 1/2), and angular acceleration resolution of 3 x 10 to the -11th rad/(s exp 2 Hz exp 1/2). The testing of a prototype gradiometer revealed that the environment-induced noise limits the noise floor to 7 x 10 to the -10th/(s exp 2 Hz exp 1/2).

Chan, H. A.↗

The Giotto ion mass spectrometer

The Giotto Ion Mass Spectrometer (IMS) consists of two sensors: one optimized for the outer and the other for the inner coma, with each obtaining complementary information in the region for which it is not optimized. The outer coma is characterized by the interaction between solar wind and comentary plasmas, the inner coma by the outflow of cometary neutrals and their ionization products. Both sensors feature mass imaging characteristics, permitting simultaneous measurements of several ion species by multidetector arrays. Resultant mass-per-charge resolution is greater than or = 20. Energy per charge, and the elevation and aximuth of incident ions are measured. Calibration and in-flight solar-wind data show that the IMS will meet its scientific goals for the Halley encounter.

Balsiger, H.↗

Research in particle and gamma-ray astrophysics

This research program is directed toward the investigation of the astrophysical aspects of cosmic rays and gamma rays and of the radiation and electromagnetic field environment of the Earth and other planets. The emphasis was on precice measurements with high resolution in charge, mass and energy. These investigations were carried out by means of energetic particle and photon detector systems flown on spacecraft and balloons.

Stone, E. C.↗

First results from the faint object camera - High-resolution observations of the central object R136 in the 30 Doradus nebula

R136 is the luminous central object of the giant H II region 30 Doradus in the LMC. The first high-resolution observations of R136 with the Faint Object Camera on board the Hubble Space Telescope are reported. The physical nature of the brightest component R136a has been a matter of some controversy over the last few years. The UV images obtained show that R136a is a very compact star cluster consisting of more than eight stars within 0.7 arcsec diameter. From these high-resolution images a mass upper limit can be derived for the most luminous stars observed in R136.

Weigelt, G.↗

A Low-cost, Lightweight, and Miniaturized Time-of-flight Mass Spectrometer (TOFMS)

Time-of-flight mass spectrometers (TOFMS) are commonly used for mass analysis and for the measurement of energy distributions of charged particles. For achieving high mass and energy resolution these instruments generally comprise long flight tubes, often as long as a few meters. This necessitates high voltages and a very clean environment. These requirements make them bulky and heavy. We have developed an instrument and calibration techniques that are based on the design principles of TOFMS. However, instead of one long flight tube it consists of a series of cylindrical electrostatic lenses that confine ions under study along the axis of the flight tube.

Srivastava, S. K.↗

Grazing Incidence Nickel Replicated Optics for Hard X-ray Telescopes

The requirements for future hard x-ray (up to 50 keV) telescopes are lightweight, high angular resolution optics with large collecting areas. Grazing incidence replicated optics are an excellent candidate for this, type of mission, providing better angular resolution, comparable area/unit mass, and simpler fabrication than multilayer-coated foils. Most importantly, the technology to fabricate the required optics currently exists. A comparison of several hard x-ray telescope designs will be presented.

Peturzzo, J. J., III↗

A Segmented Time-of-Flight Mass Spectrometer

The present paper describes the design of a time-of-flight mass spectrometer (TOFMS) in which the single flight tube of a conventional TOFMS has been replaced by several cylindrical electrostatic lenses in tandem. By a judicious choice of voltages on these lenses, an improved TOFMS has been realized which has a superior mass and energy resolution, shorter flight lengths, excellent signal-to-noise ratio and less stringent requirements on the bias voltages.

Srivastava, S. K.↗

The Constellation-X Spectroscopy X-Ray Telescope

The status of technology development for the Constellation-X Spectroscopy X-ray Telescope (SXT) mirror is presented. The SXT mirror combines a large (1.6 m) aperture with modest (12 arc sec half power diameter) angular resolution and low mass (750 kg). The overall collecting area, larger than 9,600 square cm at 0.25 keV, requires high throughput, and thus nesting of a substantial number of thin reflectors. A phased development program is underway to develop reflectors, mounting and alignment approaches, and metrology techniques for components and the mirror has a whole. The latest results in all these areas are summarized, along with an overview of results of optical testing of reflector performance.

Petre, Robert↗

Remote sensing of convective clouds with Microwave Limb Sounder

Deep convection lifts up many large ice particles to the upper troposphere where they can be detected with microwave sensors from space, using limb-viewing techniques. Microwave Limb Sounder (MLS) has unique advantages in measuring these high clouds and their ice mass with vertical resolution.

Microwave Limb Sounder↗

Compact Microwave Fourier Spectrum Analyzer

A compact photonic microwave Fourier spectrum analyzer [a Fourier-transform microwave spectrometer, (FTMWS)] with no moving parts has been proposed for use in remote sensing of weak, natural microwave emissions from the surfaces and atmospheres of planets to enable remote analysis and determination of chemical composition and abundances of critical molecular constituents in space. The instrument is based on a Bessel beam (light modes with non-zero angular momenta) fiber-optic elements. It features low power consumption, low mass, and high resolution, without a need for any cryogenics, beyond what is achievable by the current state-of-the-art in space instruments. The instrument can also be used in a wide-band scatterometer mode in active radar systems.

Savchenkov, Anatoliy↗

STEPS: JPL's Astrometric Exoplanet Survey

Presentation topics include: STEPS ground-based astrometry at Hale Telescope; the instrument; why astronomy and why M-dwarfs; motion of center of light about center of mass in photocentric orbit; photocentric motion vs. fractional mass; high-resolution imaging of STEPS targets; GU 802 p one possible orbit plotted with data, Keplerian frame; GJ 802 results; STEPS future; and a bibliography of STEPS papers.

astrometry↗

A System of Conservative Regridding for Ice-Atmosphere Coupling in a General Circulation Model (GCM)

The method of elevation classes, in which the ice surface model is run at multiple elevations within each grid cell, has proven to be a useful way for a low-resolution atmosphere inside a general circulation model (GCM) to produce high-resolution downscaled surface mass balance fields for use in one-way studies coupling atmospheres and ice flow models. Past uses of elevation classes have failed to conserve mass and energy because the transformation used to regrid to the atmosphere was inconsistent with the transformation used to downscale to the ice model. This would cause problems for two-way coupling. A strategy that resolves this conservation issue has been designed and is presented here. The approach identifies three grids between which data must be regridded and five transformations between those grids required by a typical coupled atmosphere-ice flow model. This paper develops a theoretical framework for the problem and shows how each of these transformations may be achieved in a consistent, conservative manner. These transformations are implemented in Glint2, a library used to couple atmosphere models with ice models. Source code and documentation are available for download. Confounding real-world issues are discussed, including the use of projections for ice modeling, how to handle dynamically changing ice geometry, and modifications required for finite element ice models.

Ice-atmosphere↗

A Segmented Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOFMS) is described in which the single flight tube of a conventional TOFMS has been replaced by several cylindrical electrostatic lenses in tandem. By a judicious choice of voltages on these lenses, an improved TOFMS has been realized which has a superior mass and energy resolution, shorter flight lengths, excellent signal-to-noise ratio, and less stringent requirements on the bias voltages.

time-of-flight↗

The High Fraction of Thin Disk Galaxies Continues to Challenge ΛCDM Cosmology

Any viable cosmological framework has to match the observed proportion of early- and late-type galaxies. In this contribution, we focus on the distribution of galaxy morphological types in the standard model of cosmology (Lambda cold dark matter, ΛCDM). Using the latest state-of-the-art cosmological ΛCDM simulations known as Illustris, IllustrisTNG, and EAGLE, we calculate the intrinsic and sky-projected aspect ratio distribution of the stars in subhalos with stellar mass M * > 10 10 M ⊙ at redshift z = 0. There is a significant deficit of intrinsically thin disk galaxies, which however comprise most of the locally observed galaxy population. Consequently, the sky-projected aspect ratio distribution produced by these ΛCDM simulations disagrees with the Galaxy And Mass Assembly (GAMA) survey and Sloan Digital Sky Survey at ≥12.52σ (TNG50-1) and ≥14.82σ (EAGLE50) confidence. The deficit of intrinsically thin galaxies could be due to a much less hierarchical merger-driven build-up of observed galaxies than is given by the ΛCDM framework. It might also arise from the implemented sub-grid models, or from the limited resolution of the above-mentioned hydrodynamical simulations. We estimate that an 8 5 times better mass resolution realization than TNG50-1 would reduce the tension with GAMA to the 5.58σ level. Finally, we show that galaxies with fewer major mergers have a somewhat thinner aspect ratio distribution. Given also the high expected frequency of minor mergers in ΛCDM, the problem may be due to minor mergers. In this case, the angular momentum problem could be alleviated in Milgromian dynamics because of a reduced merger frequency arising from the absence of dynamical friction between extended dark matter halos.

79 ASTRONOMY AND ASTROPHYSICS↗

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics↗

Two-fluid simulations of galaxy formation

We investigate the formation of galaxies and larger structure with a simulation modeling two gravitationally coupled fluids representing dark matter and baryons. The baryon gas dynamics are calculated with a smoothed particle hydrodynamics (SPH) method, and the physics modeled includes thermal pressure, shock heating, and radiative cooling. We simulate a 16 Mpc periodic cube with 64(exp 3) particles in each fluid and 10% baryon mass fraction. We confirm, for the first time experimentally, disk formation as a natural consequence of hierarchical clustering in a large-scale cosmological environment. The majority of isolated galaxies exhibit centrifugally supported disks. A power-law relation between cold baryonic mass and maximum rotation velocity is found, M varies as nu(sub rot)(exp alpha) with alpha = 2.5 after correcting for differential numerical resolution. Both the spatial and velocity distributions of the simulated galaxies are biased with respect to the dark matter. A counts-in-cells analysis indicates that an unphysical degree of merging in the central cluster is likely responsible for the antibias signal in the correlation function. A robust, scale-dependent velocity bias is measured. The ratio of galaxy to dark matter pairwise velocity dispersions on a scale of 1 Mpc is 0.7. The amplitude is only mildly dependent on redshift or mass cutoff and scales with separation as r(exp 0.2). The degree to which these results depend on numerical parameters is discussed. Mass resolution plays a key role in controlling the resulting fraction of cold, dense baryons. The mass fraction associated with galaxies decreases by a factor of approximately greater than 3 when the mass per particle is increased by a factor 8. Photoionization and energy input from supernova will have to be included to determine more carefully the fraction of highly dissipated material and the characteristics of the stellar component of galaxies.

Evrard, August E.↗

Investigating the Impact of Absorbed Surface Impurities (CO, CO 2 , CH 4 , and H 2 O) on Getter Rate Performance

This report provides an overview of engineering and experimental efforts to establish a new capability for measuring H2 uptake rates for Tritium Producing Abosrber Rod (TPBAR) getter materials. This new system was used to gain a better understanding of the impact of contaminant species (CO 2 , CO, CH 4 , and H 2 O) on getter performance under relevant hydrogen uptake conditions (350 °C, 20 torr). Herein, we successfully established a high-resolution gravimetric sorption (HRGS) system in a flow through configuration that can measure sample mass changes with high resolution (1 µg or 10 µg) over long experiment times (days), high temperature, and varying pressures. We coupled this capability with an in-line universal gas analyzer (UGA) system to characterize potential surface chemistry side reactions occurring after contaminant gas exposure. The major findings of this study suggest that methane and CO have the most detrimental effects on getter H 2 uptake performance showing large changes in rate after exposure compared to CO 2 and water. The effect of these contaminant species did not influence getter sample capacity (~ 1.8 wt% H 2 ). After CO and methane exposure, changes in getter rate were accompanied by observable Ni-surface defects and pinholes via SEM imaging suggesting possible Ni- layer corrosion. Additionally, the increase in C and O signal in the zircaloy layer, observed via EDX, point to C and O species transport through the getter sample resulting in the formation of carbides and oxide species. Thus, co-exposure studies where mixed gases or water vapor are introduced together will be important to further understand what mechanisms are contributing to Ni-layer corrosion and changes in getter performance.

36 MATERIALS SCIENCE↗