Laser system for natural gas detection. Phase 1: Laboratory feasibility studies

This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.

Grant, W. B.↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selctive field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, we are developing a double chemically-sensitive field effect transistor (dChemFET). The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. We report our work in developing the dChemFET, starting with the development of the Ag+ and NO3- ion selective memberanes (ISMs) to be used in the ChemFETs. The Ag+ ISM has a detection range of 50-105 ppb . The counter ion ISM, NO3- ISM, has shown a detection range of 400-105 ppb. NO3- ISMs are limited in detecting at lower ppb levels required for the dChemFET application on the potable water system. In response to this issue, we also report our studies in using the Ag+ ISM to measure deionized (DI) water as a reference measurement to be implemented in-line before the Ag+ is dosed.

Lance Dean Delzeit↗

Lyman continuum leakage from low-mass galaxies with M ⋆ < 108 M⊙

ABSTRACT We present observations with the Cosmic Origins Spectrograph onboard the Hubble Space Telescope of nine low-mass star-forming galaxies at redshifts, z, in the range 0.3179–0.4524, with stellar masses $M_\star \, \lt $ 108 M⊙ and very high specific star-formation rates sSFR ∼150–630 Gyr−1, aiming to study the dependence of leaking Lyman continuum (LyC) emission on stellar mass and some other characteristics of the galaxy. We detect LyC emission in four out of nine galaxies with escape fractions, fesc(LyC), in the range of 11–35 per cent, and establish upper limits for fesc(LyC) in the remaining five galaxies. We observe a narrow Ly α emission line with two peaks in seven galaxies and likely more complex Ly α profiles in the two remaining galaxies. The velocity separation between the peaks Vsep varies in the range from ∼229 to ∼512 km s−1. Our additional data on low-mass galaxies confirm and strengthen the tight anticorrelation between fesc(LyC) and Vsep found for previous low-redshift galaxy samples with higher stellar masses. Vsep remains the best indirect indicator of LyC leakage. It is better than O32 on which fesc(LyC) depends weakly, with a large scatter. Finally, contrary to expectations, we find no increase of fesc(LyC) with decreasing galaxy stellar mass M⋆.

Izotov, Y. I.↗

Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

Shannon, A. V.↗

Laboratory simulation of tunable diode laser remote measurement of atmospheric gases using topographic targets

In order to test the possibility that tunable diode laser (TDL) systems using topographic targets can be applied to the measurement of a variety of gases at concentrations and distances characteristic of industrial gas leaks, a single-ended TDL system was assembled for use with selected topographic targets to detect NO2 at atmospheric pressure and NO2 and NH3 at low pressures. In both cases, the intensity distribution of radiation backscattered from selected targets was found to be heavily weighted to a specular rather than a Lambertian distribution. A sensitivity of 5 ppm-m has been demonstrated for the case of NO2.

Webster, C. R.↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Methodological Overview of Seismic Analysis for Nuclear Event Detection

Underground explosions generate potentially detectable signatures, including energy waves that travel through the Earth’s subsurface (i.e., seismic waves), low-frequency sound waves (i.e., infrasound and hydroacoustic waves), and radioactive gases and/or particles that might leak from the test cavity (if the event was nuclear). There can also be intelligence indicators of a test, such as observations of modified patterns of life and activity at a suspected test site. If all of these detectable signatures and intelligence indicators are present and self-consistent, then analysts have high confidence in classifying a signature generating event as an explosion. However, because only partial information about an event is likely to be available, determining whether an event was natural (e.g., an earthquake or landslide) or manmade (e.g., a chemical or nuclear explosion) is much more challenging. This primer describes how one category of event signatures—seismic signatures—can augment event analyses. While universities and government organizations have generated detailed technical descriptions of seismic analytic techniques, we seek to translate seismic event analysis for a broad, non-technical audience. When the geologic conditions near an event are well-characterized, seismic data can be used to calculate critical information, such as event location and depth, with relatively high accuracy. Moreover, specific features within seismic datasets can help determine whether an event was an explosion. However, a key challenge in seismic analysis is that geologic site conditions are often poorly characterized, complicating the ability to discern the true nature of the event. To overcome this challenge, geologists answer a series of questions (discussed in section 1) to guide seismic event analysis and determine the most probable nature of an event. As more information is gathered during each analytic step, confidence grows regarding the nature of the event. Section 2 addresses uncertainties in seismic analysis and the vital nature of high-fidelity geologic data for accurate seismic event analysis.

58 GEOSCIENCES↗

Ammonia Detection

The different advantageous embodiments provide for identifying gas leakage in a platform. A processor unit identifies a rate of the gas of the substance leaking from a container in a first compartment for a platform. The processor unit also identifies an amount of gas that has leaked from the container at a selected time based on the rate of the gas of the substance leaking from the container and a total time. The processor unit identifies an amount of the gas of the substance present in a number of compartments associated with the first compartment using the amount of gas leaked from the container in the first compartment and a pressure for each compartment in the number of compartments. The processor unit determines whether the amount of gas in at least one of the first compartment and the number of compartments is outside of a desired amount for the gas.

Ward, William Douglas↗

CsPbBr3 perovskite detectors with 1.4% energy resolution for high-energy γ-rays

Halide perovskite semiconductors are poised to revitalize the field of ionizing radiation detection as they have done to solar photovoltaics. We show that all-inorganic perovskite CsPbBr 3 devices resolve 137 Cs 662-keV γ-rays with 1.4% energy resolution, as well as other X- and γ-rays with energies ranging from tens of keV to over 1 MeV in ambipolar sensing and unipolar hole-only sensing modes with crystal volumes of 6.65 mm 3 and 297 mm 3 , respectively. Furthermore, we report the scale-up of CsPbBr 3 ingots to up to 1.5 inches in diameter with an excellent hole mobility–lifetime product of 8 × 10 -3 cm 2 V -1 and a long hole lifetime of up to 296 μs. CsPbBr 3 detectors demonstrate a wide temperature region from ~2 °C to ~70 °C for stable operation. Detectors protected with suitable encapsulants show a uniform response for over 18 months. Consequently, we identify perovskite CsPbBr 3 semiconductor as an exceptional candidate for new-generation high-energy γ-ray detection.

47 OTHER INSTRUMENTATION↗

A solenoid failure detection system for cold gas attitude control jet valves

The development of a solenoid valve failure detection system is described. The technique requires the addition of a radioactive gas to the propellant of a cold gas jet attitude control system. Solenoid failure is detected with an avalanche radiation detector located in the jet nozzle which senses the radiation emitted by the leaking radioactive gas. Measurements of carbon monoxide leakage rates through a Mariner type solenoid valve are presented as a function of gas activity and detector configuration. A cylindrical avalanche detector with a factor of 40 improvement in leak sensitivity is proposed for flight systems because it allows the quantity of radioactive gas that must be added to the propellant to be reduced to a practical level.

Johnston, P. A.↗

Portable Gas Analyzer

The Michromonitor M500 universal gas analyzer contains a series of miniature modules, each of which is a complete gas chromatograph, an instrument which separates a gaseous mixture into its components and measures the concentrations of each gas in the mixture. The system is manufactured by Microsensor Technology, and is used for environmental analysis, monitoring for gas leaks and chemical spills, compliance with pollution laws, etc. The technology is based on a Viking attempt to detect life on Mars. Ames/Stanford miniaturized the system and NIOSH funded further development. Three Stanford researchers commercialized the technology, which can be operated by unskilled personnel.

Source record↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fatigue Crack Measurement in Composite Materials by Ultrasonic Methods

The nondestructive detection of intra-ply microcracking in unlined pressure vessels fabricated from composite materials is critical to ensuring mission success. Microcracking in composite structures due to combined fatigue and cryogenic thermal loading can be very troublesome to detect in-service and when it begins to link through the thickness can cause leakage and failure of the structure. These leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. The work presented herein develops a method and an instrument to locate and measure intraply fatigue cracking through the thickness of laminated composite material by means of correlation with ultrasonic resonance. Resonant ultrasound spectroscopy provides measurements which are, sensitive to both the microscopic and macroscopic properties of an object. Elastic moduli, acoustic attenuation, and geometry can all be probed. The approach is based on the premise of half-wavelength resonance. The method injects a broadband ultrasonic wave into the test structure using a swept frequency technique. This method provides dramatically increased energy input into the test article, as compared to conventional spike pulsed ultrasonics. This relative energy increase improves the ability to measure finer details in the materials character, such as micro-cracking and porosity. As the micro-crack density increases, more interactions occur with the higher frequency (small wavelength) components of the signal train causing the spectrum to shift toward lower frequencies. Preliminary experiments have verified a measurable effect on the resonance spectrum of the ultrasonic data to detect microcracking. Methods involving self organizing neural networks and other clustering algorithms show that the resonance ultrasound signatures from composites vary with the degree of microcracking and can be separated and identified.

Walker, James L.↗