Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Magnetic Field Vector Measurements Using Doppler-Free Saturation Spectroscopy

Experimentally measuring the magnetic-field vector topology in low-cost fusion-concept devices will provide critical information required to optimize and accelerate the development of those concepts for economical fusion energy. The magnetic-field measurement techniques most commonly used in modern tokamaks, i.e., beam-emission spectroscopy and optical emission spectroscopy, are not suitable below 5000 Gauss due to a lack of sensitivity. To diagnose magnetic field relevant to some of the ARPA-E-supported fusion concepts (50 to 1000 Gauss), a novel approach is required. Doppler-free saturation spectroscopy (DFSS) is a pump/probe laser-based technique and has been successfully demonstrated in the laboratory to provide a magnetic-field measurement accuracy of <10 Gauss. DFSS is implemented to obtain ultra-high-resolution spectra at a localized point in space. The spectral data is then fit to the Schrödinger equation for determination of the magnetic-field vector. To obtain the magnetic-field topology, the measurement spatial location is scanned over the desired region of space by steering the DFSS pump laser beam. The goal of this project is to assemble and commission a portable DFSS diagnostic capable of 2-D magnetic-field vector measurements utilizing the Hα spectral line profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗

Quantum yield for carbon monoxide production in the 248 nm photodissociation of carbonyl sulfide (OCS)

Tunable diode laser absorption spectroscopy has been coupled with excimer laser flash photolysis to measure the quantum yield for CO production from 248 nm photodissociation of carbonyl sulfide (OCS) relative to the well-known quantum yield for CO production from 248 nm photolysis of phosgene (Cl2CO2). The temporal resolution of the experiments was sufficient to distinguish CO formed directly by photodissociation from that formed by subsequent S((sup 3)P(sub J)) reaction with OCS. Under the experimental conditions employed, CO formation via the fast S((sup 1)D(sub 2)) + OCS reaction was minimal. Measurements at 297K and total pressures from 4 to 100 Torr N2 + N2O show the CO yield to be greater than 0.95 and most likely unity. This result suggests that the contribution of OCS as a precursor to the lower stratospheric sulfate aerosol layer is somewhat larger than previously thought.

Zhao, Z.↗

Kinetics of the Reaction C2H + O2 from 193 to 350 K Using Laser Flash Kinetic Infrared Absorption Spectroscopy

Rate coefficients for the reaction C2H + O2 are measured from 193 to 350 K by using transient absorption spectroscopy with an infrared color center laser. Ethynyl radicals are produced by pulsed laser photolysis of C2H2 in a temperature variable flow cell and a tunable color center laser probes the transient removal Of C2H ((bar-X(sup 2))Sigma(+))(0,0,0)) in absorption. The rate coefficient has a slight negative temperature dependence over the range 193-350 K which can be expressed as k(O2) = (1.5 +/- 0.3) x 10(exp -11) exp((230 +/- 36)/T) Cu cm/(Molecule.s). The lack of a pressure dependence under our experimental conditions strongly suggests that the HCCOO* complex is short lived with respect to encountering a collision and rapidly dissociates to products without competition from collisional stabilization to HCCOO or collisionally induced dissociation to reactants.

Opansky, Brian J.↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

Comparison of excitation temperature of a laser-produced plasma by combining emission and absorption spectroscopy

Measurement of the temporal evolution of laser-produced plasma temperature is very important for many of its applications, and several plasma diagnostic tools are routinely used by researchers. However, it is very challenging to measure the properties of the plasma at the early and late times of its evolution using a single diagnostic tool. In this study, we combined emission and laser absorption spectroscopy to compare the excitation temperatures of a laser-produced uranium plasma system. Several U I transitions in the near-infrared spectral range (775–800 nm) were considered, and the Boltzmann plot method was used to measure the excitation temperatures using both emission and absorption spectroscopy. Emission spectroscopy provided early-time temperature measurements of the plasma up to times 2–20 µs, while absorption spectroscopy provided temperature measurements at late times of plasma evolution (for times 5–80 µs). The emission and absorbance of U I transitions were found to follow the Boltzmann distribution, indicating the plasma is likely in the state of local thermodynamic equilibrium even at late times of its lifetime. The emission and absorption-based time-resolved excitation temperatures demonstrated good agreement at earlier times (≤15 µs) in the overlapped temporal region, while a deviation in the measured values was seen at times (≥15 µs), and potential reasons for such a disagreement are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor

Carbon monoxide (CO) has been implicated as a biological messenger molecule analogous to nitric oxide. A compact gas sensor based on a midinfrared laser absorption spectroscopy was developed for direct and real-time measurement of trace levels (in approximate pmol) of CO release by vascular cells. The midinfrared light is generated by difference frequency mixing of two nearinfrared lasers in a nonlinear optical crystal. A strong infrared absorption line of CO (4.61 microm) is chosen for convenient CO detection without interference from other gas species. The generation of CO from cultured vascular smooth muscle cells was detected every 20 s without any chemical modification to the CO. The sensitivity of the sensor reached 6.9 pmol CO. CO synthesis was measured from untreated control cells (0.25 nmol per 10(7) cells/h), sodium nitroprusside-treated cells (0.29 nmol per 10(7) cells/h), and hemin-treated cells (0.49 nmol per 10(7) cells/h). The sensor also detected decreases in CO production after the addition of the heme oxygenase (HO) inhibitor tin protoporphyrin-IX (from 0.49 to 0.02 nmol per 10(7) cells/h) and increases after the administration of the HO substrate hemin (from 0.27 to 0.64 nmol per 10(7) cells/h). These results demonstrate that midinfrared laser absorption spectroscopy is a useful technique for the noninvasive and real-time detection of trace levels of CO from biological tissues.

Non-NASA Center↗

Single-shot X-ray absorption spectroscopy at X-ray free electron lasers

X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method for studying electronic and structural properties of matter. At first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of X-ray Free Electron Lasers (XFEL) sources seem to require accumulation over many shots to achieve high data quality. To date the best approach to implementing XAS at XFEL facilities has been using monochromators to scan the photon energy across the desired spectral range. While this is possible for easily reproducible samples such as liquids, it is incompatible with many important systems. Here, we demonstrate collection of single-shot XAS spectra over 10s of eV using an XFEL source, with error bars of only a few percent. We additionally show how to extend this technique over wider spectral ranges towards Extended X-ray Absorption Fine Structure measurements, by concatenating a few tens of single-shot measurements. Our results pave the way for future XAS studies at XFELs, in particular those in the femtosecond regime. This advance is envisioned to be especially important for many transient processes that can only be initiated at lower repetition rates, for difficult to reproduce excitation conditions, or for rare samples, such as those encountered in high-energy density physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Double-modulation spectroscopy of molecular ions - Eliminating the background in velocity-modulation spectroscopy

Velocity-modulation spectroscopy is an established technique for performing laser absorption spectroscopy of molecular ions in a discharge. However, such experiments are often plagued by a coherent background signal arising from emission from the discharge or from electronic pickup. Fluctuations in the background can obscure the desired signal. A simple technique using amplitude modulation of the laser and two lock-in amplifiers in series to detect the signal is demonstrated. The background and background fluctuations are thereby eliminated, facilitating the detection of molecular ions.

Lan, Guang↗

Robust quantification of the diamond nitrogen-vacancy center charge state via photoluminescence spectroscopy

Nitrogen vacancy (NV) centers in diamond are at the heart of many emerging quantum technologies, all of which require control over the NV charge state. Hence, methods for quantification of the relative photoluminescence intensities of the NV 0 and NV − charge states, i.e., a charge state ratio, are vital. Several approaches to quantify NV charge state ratios have been reported but are either limited to bulk-like NV diamond samples or yield qualitative results. We propose an NV charge state quantification protocol based on the determination of sample- and experimental setup-specific NV 0 and NV − reference spectra. The approach employs blue (400–470 nm) and green (480–570 nm) excitation to infer pure NV 0 and NV − spectra, which are then used to quantify NV charge state ratios in subsequent experiments via least squares fitting. We test our dual excitation protocol (DEP) for a bulk diamond NV sample and 20 and 100 nm nanodiamond particles and compare results with those obtained via other commonly used techniques such as zero-phonon line fitting and non-negative matrix factorization. We find that DEP can be employed across different samples and experimental setups and yields consistent and quantitative results for NV charge state ratios that are in agreement with our understanding of NV photophysics. By providing robust NV charge state quantification across sample types and measurement platforms, DEP will support the development of NV-based quantum technologies.

Color center laser spectroscopy↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

Low-Temperature Rate Coefficients of C2H with CH4 and CD4 from 154 to 359 K

Rate coefficients for the reaction C2H + CH4 yields C2H2 + CH3 and C2H + CD4 yields C2HD + CD3 are measured over the temperature range 154-359 K using transient infrared laser absorption spectroscopy. Ethynyl radicals are produced by pulsed laser photolysis of C2H2 in a variable temperature flow cell, and a tunable color center laser probes the transient removal of C2H (Chi(exp 2) Sigma(+) (0,0,0)) in absorption. The rate coefficients for the reactions of C2H with CH4 and CD4 both show a positive temperature dependence over the range 154-359 K, which can be expressed as k(sub CH4) = (1.2 +/- 0.1) x 10(exp -11) exp((-491 +/- 12)/T) and k(sub CD4) = (8.7 +/- 1.8) x 10(exp -12) exp((-650 +/- 61)/T) cm(exp 3) molecule(exp -1) s(exp -1), respectively. The reaction of C2H + CH4 exhibits a significant kinetic isotope effect at 300 K of k(sub CH4)/k(sub CD4) = 2.5 +/- 0.2. Temperature dependent rate constants for C2H + C2H2 were also remeasured over an increased temperature range from 143 to 359 K and found to show a slight negative temperature dependence, which can be expressed as k(sub C2H2) = 8.6 x 10(exp -16) T(exp 1.8) exp((474 +/- 90)/T) cm(exp 3) molecule(exp -1) s(exp -1).

Opansky, Brian J.↗

Combining femtosecond laser annealing and shallow ion implantation for local color center creation in diamond

A common technique for color center creation in wideband gap semiconductors employs ion implantation and a subsequent thermal annealing. In general, this annealing process is conducted in a vacuum oven. Here, we exploit the annealing based on femtosecond laser pulses. For that purpose, we implant fluorine ions at 54 keV and chlorine ions at 74 keV in diamond and perform micrometer precise annealing using focused femtosecond laser pulses at 800 ± (30) nm with different pulse numbers and repetition rates. In this way, we were able to create shallow spots with color centers of varying brightness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate quantum yields by laser gain vs absorption spectroscopy - Investigation of Br/Br(asterisk) channels in photofragmentation of Br2 and IBr

Various techniques have been used to study photodissociation dynamics of the halogens and interhalogens. The quantum yields obtained by these techniques differ widely. The present investigation is concerned with a qualitatively new approach for obtaining highly accurate quantum yields for electronically excited states. This approach makes it possible to obtain an accuracy of 1 percent to 3 percent. It is shown that measurement of the initial transient gain/absorption vs the final absorption in a single time-resolved signal is a very accurate technique in the study of absolute branching fractions in photodissociation. The new technique is found to be insensitive to pulse and probe laser characteristics, molecular absorption cross sections, and absolute precursor density.

Haugen, H. K.↗

Development of Advanced Seed Laser Modules for Lidar and Spectroscopy Applications

We report on recent progress made in the development of highly compact, single mode, distributed feedback laser (DFB) seed laser modules for lidar and spectroscopy applications from space based platforms. One of the intended application of this technology is in the NASA's Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The DFB laser modules operating at 1571 nm and 1262 nm have advanced current and temperature drivers built into them. A combination of temperature and current tuning allows coarse and fine adjustment of the diode wavelengths.

Prasad, Narasimha S.↗

Tunable lasers and their application in analytical chemistry

The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.

Steinfeld, J. I.↗

Ground state rotational and kinetic temperatures of C 2 molecules in a laser-produced plasma

This study presents an experimental comparison between rotational and kinetic temperatures of molecular species in a laser-produced plasma, utilizing tunable laser absorption spectroscopy. We analyzed high-resolution and time-resolved absorption spectra of 31 rotational transitions within the Phillips A 1 II u –X 1 Σ g 3-0 band of the C 2 molecule, measured from a laser-produced graphite plasma in ~2 Torr argon, within the 771–781 nm spectral range. Spectral fitting provided quantitative state column densities of C 2 rotational energy levels in the ground electronic and vibrational states. Boltzmann analysis revealed thermalized rotational distributions showing rotational temperatures decreasing from 3000 to 600 K within 5–500 μs following the onset of the laser plasma. The measured kinetic and rotational temperatures of C 2 molecules are comparable, suggesting that collisional processes in the laser-produced plasma are sufficient to maintain thermal equilibrium between the C 2 molecules and the Ar background gas.

Absorption spectroscopy↗