Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Hydrogen detection study

The effectiveness was assessed of a hydrogen (H2) detection concept for regenerative environmental control life support systems (EC/LSS). The concept evaluated was that utilized for the electrochemical depolarized concentrator (EDC) design, constructed, and tested for the EC/LSS space station prototype program. The EDC contains combustible gas detectors (CGDs) which were evaluated with H2. The CGDs were evaluated for linearity, position sensitivity, reproducibility, ambient effects, repeatability, speed of response, recovery time, and interchangeability. The effectiveness of CGDs located within the EDC for sensing H2 leaks at various line replaceable units in the subsystem was determined. The effects of H2 leak rate, H2 concentration of leaking gas and air currents in the vicinity of the EDC were determined. Proposed improvements for the H2 detection concept were documented and alternative H2 detection approaches were identified and analyzed.

Shumar, J. W.↗

Technology Development for the Advanced Technology Large Aperture Space Telescope (ATLAST) as a Candidate Large UV-Optical-Infrared (LUVOIR) Surveyor

The Advanced Technology Large Aperture Space Telescope (ATLAST) team has identified five key technologies to enable candidate architectures for the future large-aperture ultraviolet/optical/infrared (LUVOIR) space observatory envisioned by the NASA Astrophysics 30-year roadmap, Enduring Quests, Daring Visions. The science goals of ATLAST address a broad range of astrophysical questions from early galaxy and star formation to the processes that contributed to the formation of life on Earth, combining general astrophysics with direct-imaging and spectroscopy of habitable exoplanets. The key technologies are: internal coronagraphs, starshades (or external occulters), ultra-stable large-aperture telescopes, detectors, and mirror coatings. Selected technology performance goals include: 1x1010 raw contrast at an inner working angle of 35 milli-arcseconds, wavefront error stability on the order of 10 pm RMS per wavefront control step, autonomous on-board sensing & control, and zero-read-noise single-photon detectors spanning the exoplanet science bandpass between 400 nm and 1.8 μm. Development of these technologies will provide significant advances over current and planned observatories in terms of sensitivity, angular resolution, stability, and high-contrast imaging. The science goals of ATLAST are presented and flowed down to top-level telescope and instrument performance requirements in the context of a reference architecture: a 10-meter-class, segmented aperture telescope operating at room temperature (~290 K) at the sun-Earth Lagrange-2 point. For each technology area, we define best estimates of required capabilities, current state-of-the-art performance, and current Technology Readiness Level (TRL) - thus identifying the current technology gap. We report on current, planned, or recommended efforts to develop each technology to TRL 5.

Technology Development↗

Post Launch Calibration and Testing of the Advanced Baseline Imager on the GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United State's National Oceanic and Atmospheric Administration. The first launch of the GOES-R series is planned for October 2016. The GOES-R series satellites and instruments are being developed by the National Aeronautics and Space Administration (NASA). One of the key instruments on the GOES-R series is the Advance Baseline Imager (ABI). The ABI is a multi-channel, visible through infrared, passive imaging radiometer. The ABI will provide moderate spatial and spectral resolution at high temporal and radiometric resolution to accurately monitor rapidly changing weather. Initial on-orbit calibration and performance characterization is crucial to establishing baseline used to maintain performance throughout mission life. A series of tests has been planned to establish the post launch performance and establish the parameters needed to process the data in the Ground Processing Algorithm. The large number of detectors for each channel required to provide the needed temporal coverage presents unique challenges for accurately calibrating ABI and minimizing striping. This paper discusses the planned tests to be performed on ABI over the six-month Post Launch Test period and the expected performance as it relates to ground tests.

Instrument↗

Post Launch Calibration and Testing of the Advanced Baseline Imager on the GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration. The first launch of the GOES-R series is planned for October 2016. The GOES-R series satellites and instruments are being developed by the National Aeronautics and Space Administration (NASA). One of the key instruments on the GOES-R series is the Advance Baseline Imager (ABI). The ABI is a multi-channel, visible through infrared, passive imaging radiometer. The ABI will provide moderate spatial and spectral resolution at high temporal and radiometric resolution to accurately monitor rapidly changing weather. Initial on-orbit calibration and performance characterization is crucial to establishing baseline used to maintain performance throughout mission life. A series of tests has been planned to establish the post launch performance and establish the parameters needed to process the data in the Ground Processing Algorithm. The large number of detectors for each channel required to provide the needed temporal coverage presents unique challenges for accurately calibrating ABI and minimizing striping. This paper discusses the planned tests to be performed on ABI over the six-month Post Launch Test period and the expected performance as it relates to ground tests.

Instrument↗

Nancy Grace Roman Space Telescope Observatory Implementation and Challenges

NASA’s Nancy Grace Roman Space Telescope (Roman), previously referred to as Wide Field Infrared Survey Telescope (WFIRST), was named after Dr. Nancy Grace Roman, an astronomer and NASA pioneer of modern space-based astronomy who is known as the “mother of the Hubble Space Telescope”. Roman is a deep space infrared observatory with a Hubble-sized telescope and wide field of view instrument (greater than 100 times that of Hubble’s) that will conduct a high latitude time-domain survey, a high latitude imaging and spectroscopic survey, and a galactic bulge time-domain survey to characterize dark energy and expand the census of exoplanets in our galaxy while allowing a broad range of astrophysics research. Roman will also demonstrate exoplanet coronagraphy with active wave front control technology and provide general investigator programs for the science community. Roman is finishing the critical design phase and is planning for launch in 2026. It will operate in a quasi-halo orbit about Sun-Earth L2, 1.5 million kilometers from Earth, for a five-year primary mission life. The Observatory features an Optical Telescope Assembly with an existing, repurposed 2.4m primary mirror, a Wide Field Instrument with a focal plane array comprised of 18 HgCdTe near-infrared detectors and a grism, prism and filter elements for imaging and spectroscopy in support of the primary surveys, as well as a Coronagraph instrument technology demonstration with starlight suppression technology for direct imaging and spectroscopy of exoplanets. The telescope is mounted to the Instrument Carrier composite truss structure which also optically meters each instrument, includes a Launch Load and Vibration Isolation System to provide passive isolation of spacecraft jitter sources while also supporting the payload during launch and is attached to the Spacecraft Bus. The Spacecraft also includes a Solar Array Sunshield ,Deployable Aperture Cover, Lower Instrument Sunshade, High Gain Antenna System, and Outer Barrel Assembly. Figure 1 shows an overview of the Roman Observatory. When fully integrated, Roman will be the largest Observatory assembled and tested at NASA’s Goddard Space Flight Center. Figure 1. Roman Observatory Overview Development of scientific satellites is challenging by nature, as the pursuit to broaden scientific knowledge always pushes the boundary of what has come before. The implementation of the Roman mission is a prime example and expected challenges have been augmented by the foundational decision to use the existing telescope components, developed in the early 2000s by another Government agency for a different application. Other unique aspects of the Roman mission, such as its survey nature, the vast amount of data required to meet science objectives, and packaging of the Observatory elements around the existing telescope components, create constrained design spaces that drive competing requirements across Observatory subsystems. Given these challenges, systems engineering has been a critical discipline in balancing implementation decisions for the Roman mission and will continue to play a key role going forward. This paper will discuss details of the Roman Observatory configuration, as well as some of the systems engineering challenges and the decision-making process used to mature the Roman Space Telescope preliminary design to implementation.

Lisa Ml Bartusek↗

SU-F-T-368: Improved HPGe Detector Precise Efficiency Calibration with Monte Carlo Simulations and Radioactive Sources

Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excited states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MagicPlate-512: A 2D silicon detector array for quality assurance of stereotactic motion adaptive radiotherapy

Purpose: Spatial and temporal resolutions are two of the most important features for quality assurance instrumentation of motion adaptive radiotherapy modalities. The goal of this work is to characterize the performance of the 2D high spatial resolution monolithic silicon diode array named “MagicPlate-512” for quality assurance of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) combined with a dynamic multileaf collimator (MLC) tracking technique for motion compensation. Methods: MagicPlate-512 is used in combination with the movable platform HexaMotion and a research version of radiofrequency tracking system Calypso driving MLC tracking software. The authors reconstruct 2D dose distributions of small field square beams in three modalities: in static conditions, mimicking the temporal movement pattern of a lung tumor and tracking the moving target while the MLC compensates almost instantaneously for the tumor displacement. Use of Calypso in combination with MagicPlate-512 requires a proper radiofrequency interference shielding. Impact of the shielding on dosimetry has been simulated by GEANT4 and verified experimentally. Temporal and spatial resolutions of the dosimetry system allow also for accurate verification of segments of complex stereotactic radiotherapy plans with identification of the instant and location where a certain dose is delivered. This feature allows for retrospective temporal reconstruction of the delivery process and easy identification of error in the tracking or the multileaf collimator driving systems. A sliding MLC wedge combined with the lung motion pattern has been measured. The ability of the MagicPlate-512 (MP512) in 2D dose mapping in all three modes of operation was benchmarked by EBT3 film. Results: Full width at half maximum and penumbra of the moving and stationary dose profiles measured by EBT3 film and MagicPlate-512 confirm that motion has a significant impact on the dose distribution. Motion, no motion, and motion with MLC tracking profiles agreed within 1 and 0.4 mm, respectively, for all field sizes tested. Use of electromagnetic tracking system generates a fluctuation of the detector baseline up to 10% of the full scale signal requiring a proper shielding strategy. MagicPlate-512 is also able to reconstruct the dose variation pulse-by-pulse in each pixel of the detector. An analysis of the dose transients with motion and motion with tracking shows that the tracking feedback algorithm used for this experiment can compensate effectively only the effect of the slower transient components. The fast changing components of the organ motion can contribute only to discrepancy of the order of 15% in penumbral region while the slower components can change the dose profile up to 75% of the expected dose. Conclusions: MagicPlate-512 is shown to be, potentially, a valid alternative to film or 2D ionizing chambers for quality assurance dosimetry in SRS or SBRT. Its high spatial and temporal resolutions allow for accurate reconstruction of the profile in any conditions with motion and with tracking of the motion. It shows excellent performance to reconstruct the dose deposition in real time or retrospectively as a function of time for detailed analysis of the effect of motion in a specific pixel or area of interest.

60 APPLIED LIFE SCIENCES↗

Stressed Ge:Ga photoconductors for space-based astronomy. (Is there life beyond 120 micron)

Information is given in viewgraph form. Information is given on the characteristics of stressed Ge:Ga, a spring type stress cavity, mounting hardware, materials parameters affecting dark current, and the behavior of low dark current stressed Ge:Ga. It is concluded that detectors exist today for background-limited detection at 200 microns, that researchers are narrowing in on the significant parameters that effect dark current in stressed photoconductors, that these findings may be applied to other photoconductor materials, and that some creative problem solving for an ionizing effect reset mechanism is needed.

Beeman, J. W.↗

Reinvestigation of the Direct Two-Proton Decay of the Long-Lived Isomer {sup 94}Ag{sup m}[0.4 s, 6.7 MeV, (21+)]

An attempt to confirm the reported direct one-proton and two-proton decays of the (21+) isomer at 6.7(5) MeV in {sup 94}Ag has been made. The 0.39(4) s half-life of the isomer permitted use of a helium-jet system to transport reaction products from the {sup 40}Ca+{sup nat}Ni reaction at 197 MeV to a low-background area; 24 gas DELTAE-(Si)E detector telescopes were used to identify emitted protons down to 0.4 MeV. No evidence was obtained for two-proton radioactivity with a summed energy of 1.9(1) MeV and a branching ratio of 0.5(3)%. Two groups of one-proton radioactivity from this isomer had also been reported; our data confirm the lower energy group at 0.79(3) MeV with its branching ratio of 1.9(5)%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic Technology: Ongoing Developments for the Next Decade

To obtain optimum sensitivity a submillimeter space observatory will require low temperature mirrors (approx. 3K) and very low temperature detectors (< or approx. 0.1 K). Both of these temperatures have been achieved by space cryogenic systems, but neither for a 10 year duration. Past systems used superfluid helium to provide direct cooling in the 1 to 2 K range (IRAS, COBE, IRTS, ISO) or as an upper stage for an adiabatic demagnetization refrigerator to achieve temperatures down to 0.06 K (Astro-E/XRS). Boiloff vapor may be used to cool an otherwise warm telescope as in the Space InfraRed Telescope Facility (SIRTF). In SIRTF a 0.85 m telescope is cooled to 5.5 K by absorbing about 6 mW in the cold vapor. This residual heat is due to both radiation from a helium vapor cooled outer shield at about 20 K and from conduction through a structure mounting the cold telescope and instruments to the warm spacecraft. The boil off rate required to cool the telescope results in a 2.6 to 5 year lifetime, depending on whether other parasitic heat sources such as thermoacoustic oscillations are also present. A helium dewar results in a very heavy system to achieve 2 to 5 year lifetimes. For example it takes roughly 400 kg for XRS to achieve 0.06 K for two year life with a 250 K boundary temperature, and approx. 300 kg (including thermal shielding) for SIRTF to achieve 1.3 K for 5 year life with a 35 K boundary temperature. To go to longer duration and to lower the weight, active cooling methods are required combined with more aggressive passive cooling techniques. It is possible, with some development, to provide cooling for detectors to 0.05 K and telescopes and instruments to < 4 K for a 10 year mission with a 100 kg system including power sources, structural support, and vacuum enclosures for critical portions of the instruments.

DiPirro, Michael↗

Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology

We report the measurement of the two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2\nu}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2\nu\beta\beta$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3\sigma$, that the single-state dominance model of the $2\nu\beta\beta$ decay of $^{100}$Mo is favored over the high-state dominance model.

01 COAL, LIGNITE, AND PEAT↗

WE-EF-303-07: Imaging of Prompt Gamma Rays Emitted During Delivery of Clinical Proton Beams with a Compton Camera: Feasibility Studies for Range Verification

Purpose: Evaluation of a prototype Compton camera (CC) for imaging prompt gamma rays (PG) emitted during clinical proton beam irradiation for in vivo beam range verification. Methods: We irradiated a water phantom with 114 MeV and 150 MeV proton pencil beams at clinical beam currents ranging from 1 nA up to 5 nA. The CC was placed 15 cm from the beam central axis and PGs from 0.2 MeV up to 6.5 MeV were measured during irradiation. From the measured data, 2-dimensional (2D) PG images were reconstructed. One-dimensional (1D) profiles from the PG images were compared to measured depth dose curves. Results: The CC was able to measure PG emission during delivery of both a single 150 MeV pencil beam and a 5 cm x 5 cm mono-energetic layer of 114 MeV pencil beams. From the 2D images, a strong correlation was seen between the depth of the distal falloff of PG emission and the Bragg peak (BP). 1D profiles extracted from the PG images show that the distal 60% falloff of the PG emission lined up well with the distal 90% of the BP. Shifts as small as 3 mm in the beam range could be detected on both the 2D PG images and 1D profiles with an uncertainty of 1.5 mm. With the current CC prototype, a minimum dose delivery of 400 cGy was required to produce usable PG images. Conclusions: It was possible to measure and image PG emission with our prototype CC during proton beam delivery and to detect shifts in the BP range in the images. Therefore prompt gamma imaging with a CC for the purpose of in vivo range verification is feasible. However, for the studied system improvements in detector efficiency and reconstruction algorithms are necessary to make it clinically viable.

60 APPLIED LIFE SCIENCES↗

SU-C-209-03: Anti-Scatter Grid-Line Artifact Minimization for Removing the Grid Lines for Three Different Grids Used with a High Resolution CMOS Detector

Purpose: Demonstrate the effectiveness of an anti-scatter grid artifact minimization method by removing the grid-line artifacts for three different grids when used with a high resolution CMOS detector. Method: Three different stationary x-ray grids were used with a high resolution CMOS x-ray detector (Dexela 1207, 75 µm pixels, sensitivity area 11.5cm × 6.5cm) to image a simulated artery block phantom (Nuclear Associates, Stenosis/Aneurysm Artery Block 76–705) combined with a frontal head phantom used as the scattering source. The x-ray parameters were 98kVp, 200mA, and 16ms for all grids. With all the three grids, two images were acquired: the first for a scatter-less flat field including the grid and the second of the object with the grid which may still have some scatter transmission. Because scatter has a low spatial frequency distribution, it was represented by an estimated constant value as an initial approximation and subtracted from the image of the object with grid before dividing by an average frame of the grid flat-field with no scatter. The constant value was iteratively changed to minimize residual grid-line artifact. This artifact minimization process was used for all the three grids. Results: Anti-scatter grid lines artifacts were successfully eliminated in all the three final images taken with the three different grids. The image contrast and CNR were also compared before and after the correction, and also compared with those from the image of the object when no grid was used. The corrected images showed an increase in CNR of approximately 28%, 33% and 25% for the three grids, as compared to the images when no grid at all was used. Conclusion: Anti-scatter grid-artifact minimization works effectively irrespective of the specifications of the grid when it is used with a high spatial resolution detector. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Poster – 02: Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences

PET images are affected by the presence of scattered photons. Incorrect scatter-correction may cause artifacts, particularly in 3D PET systems. Current scatter reconstruction methods do not distinguish between single and higher order scattered photons. A dual-scattered reconstruction method (GDS-MLEM) that is independent of the number of Compton scattering interactions and less sensitive to the need for high energy resolution detectors, is proposed. To avoid overcorrecting for scattered coincidences, the attenuation coefficient was calculated by integrating the differential Klein-Nishina cross-section over a restricted energy range, accounting only for scattered photons that were not detected. The optimum image can be selected by choosing an energy threshold which is the upper energy limit for the calculation of the cross-section and the lower limit for scattered photons in the reconstruction. Data was simulated using the GATE platform. 500,000 multiple scattered photon coincidences with perfect energy resolution were reconstructed using various methods. The GDS-MLEM algorithm had the highest confidence (98%) in locating the annihilation position and was capable of reconstructing the two largest hot regions. 100,000 photon coincidences, with a scatter fraction of 40%, were used to test the energy resolution dependence of different algorithms. With a 350–650 keV energy window and the restricted attenuation correction model, the GDS-MLEM algorithm was able to improve contrast recovery and reduce the noise by 7.56%–13.24% and 12.4%–24.03%, respectively. This approach is less sensitive to the energy resolution and shows promise if detector energy resolutions of 12% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution PET breast imager with improved detection efficiency

A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

60 APPLIED LIFE SCIENCES↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

Performance characteristics of dedicated molecular breast imaging systems at low doses

Purpose: The purpose of this study was to compare the system performance characteristics and lesion detection capability of two molecular breast imaging (MBI) systems: a multicrystal sodium iodide (NaI)-based single-head system and a cadmium zinc telluride (CZT)-based dual-head system at low administered doses (150–300 MBq) of Tc-99m sestamibi. Methods: System performance characteristics including count sensitivity, uniformity, energy resolution, and spatial resolution were measured using standard NEMA methods, or a modified version thereof in cases where the standard NEMA protocol could not be applied. A contrast-detail phantom with 48 lesions at varying depths from the collimator surface was used to assess lesion contrast-to-noise-ratio (CNR) using background count densities comparable to those observed in patient studies performed with administered doses of 150 MBq Tc-99m sestamibi. Lesions with CNR >3 were deemed to be detectable. Thirty patients undergoing MBI examinations with administered doses of 150–300 MBq were scanned for an additional view on the pixelated NaI system. CNR was calculated for lesions observed on patient images. Background count densities of patient images were measured and compared between the two systems. Results: Over the central field of view, integral and differential uniformity were 6.1% and 4.2%, respectively, for the pixelated NaI system, and 3.8% and 2.7%, respectively, for the CZT system. Count sensitivity was 10.8 kcts/min/MBq for the NaI system and 32.9 kcts/min/MBq for the CZT system. Energy resolution was 13.5% on the pixelated NaI system and 4.5% on the CZT system. Spatial resolution (full-width at half-maximum) for the pixelated NaI detector was 4.2 mm at a distance of 1.2 cm from the collimator and 5.2 mm at 3.1 cm. Spatial resolution of a single CZT detector was 2.9 mm at a distance of 1.2 cm from the collimator and 4.7 mm at 3.1 cm. Effective spatial resolution obtained with dual-head CZT was below 4.7 mm throughout a simulated breast thickness of 6 cm. From contrast-detail phantom images of lesions at distances of 1.5–4.5 cm from the collimator face, the CZT system detected 124 of 144 (86%) of lesions compared to 97 of 144 (67%) with the NaI system. In patient studies, from comparison of the same view with both systems, a total of 7 breast lesions were identified on CZT system in seven patients, and 4 of 7 (57%) were detected on NaI system. Patient image background count densities on the CZT system were on average 3.4 times higher than those on the NaI system. Conclusions: The CZT system demonstrated better uniformity, count sensitivity, spatial resolution, energy resolution, and lesion detection in phantom and patient studies compared to the NaI system. At administered doses of 150–300 MBq Tc-99m sestamibi, patient results obtained with CZT systems may not be directly translatable to NaI systems.

60 APPLIED LIFE SCIENCES↗

Search for double-β decay of 76 Ge to excited states of 76 Se with the Majorana Demonstrator

The M AJORANA DEMONSTRATOR is a neutrinoless double-β decay search consisting of a low-background modular array of high-purity germanium detectors, ~2/3 of which are enriched to 88% in 76 Ge. The experiment is also searching for double-beta decay of 76 Ge to excited states (e.s.) in 76 Se. 76 Ge can decay into three daughter states of 76 Se, with clear event signatures consisting of a ββ-decay followed by the prompt emission of one or two γ rays. This results with high probability in multi-detector coincidences. In this work, the granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9 kg yr of isotopic exposure, the DEMONSTRATOR has set world leading limits for each e.s. decay of 76 Ge, with 90% CL lower half-life limits in the range of (0.75–4.0) × 10 24 yr. In particular, for the 2ν transition to the first 0 + e.s. of 76 Se, a lower half-life limit of 7.5 × 10 23 yr at 90% CL was achieved.

59 ≤ A ≤ 89↗