Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Unusual isotope effect on thermal transport of single layer molybdenum disulphide

Thermal transport in single layer molybdenum disulfide (MoS{sub 2}) is critical to advancing its applications. In this paper, we use molecular dynamics simulations with first-principles force constants to study the isotope effect on the thermal transport of single layer MoS{sub 2}. Through phonon modal analysis, we found that isotopes can strongly scatter phonons with intermediate frequencies, and the scattering behavior can be radically different from that predicted by conventional scattering model based on perturbation theory, where Tamura's formula is combined with Matthiessen's rule to include isotope effects. Such a discrepancy becomes smaller for low isotope concentrations. Natural isotopes can lead to a 30% reduction in thermal conductivity for large size samples. However, for small samples where boundary scattering becomes significant, the isotope effect can be greatly suppressed. It was also found that the Mo isotopes, which contribute more to the phonon eigenvectors in the intermediate frequency range, have stronger impact on thermal conductivity than S isotopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model files for estimating snow dynamics and stable water isotopes across the East River, CO.

A coupled hydrologic and snowpack stable water isotope model is used to assesses controls on isotopic inputs across the East River, Colorado, a large, mountainous basin. The hydrologic model uses the semi-empirical, spatially distributed and publicly available U.S. Geological Survey numerical code Precipitation-Modelling Runoff System (PRMS). Water and energy are tracked daily through the atmosphere, canopy and subsurface at a 100-m grid resolution. The isotope mass balance model follows previous work by Ala-aho et al. (2017) to track stable isotopes entering the soil system as snowmelt or rain. Water stores and fluxes needed for the isotope model use hydrologic model output for each timestep and model modeled grid location. This data package provides all files related to the hydrologic model (executable, input and output files), the isotopic model calibration and the historic isotopic model (water years 2015-2020). The isotope model source code and executable are provided. The file "readme.txt" includes information on the file structure, steps to run the model, and description of included folders.

54 ENVIRONMENTAL SCIENCES↗

Millimeter-scale variations of stable isotope abundances in carbonates from banded iron-formations in the Hamersley Group of Western Australia

Several diamond drill cores from formations within the Hamersley Group of Western Australia have been studied for evidence of short-range variations in the isotopic compositions of the carbonates. For a set of 32 adjacent microbands analyzed in a specimen from the Marra Mamba Iron Formation, carbon isotope compositions of individual microbands ranged from -2.8 to -19.8 per mil compared to PDB and oxygen isotope compositions ranged from 10.2 to 20.8 per mil compared to SMOW. A pattern of alternating abundances was present, with the average isotopic contrasts between adjacent microbands being 3.0 per mil for carbon and 3.1 per mil for oxygen. Similar results were obtained for a suite of 34 microbands (in four groups) from the Bruno's Band unit of the Mount Sylvia Formation. Difficulties were experienced in preparing samples of single microbands from the Dales Gorge Member of the Brockman Iron Formation, but overall isotopic compositions were in good agreement with values reported by previous authors. Chemical analyses showed that isotopically light carbon and oxygen were correlated with increased concentrations of iron. The preservation of these millimeter-scale variations in isotopic abundances is interpreted as inconsistent with a metamorphic origin for the isotopically light carbon in the BIF carbonates. A biological origin is favored for the correlated variations in 13C and Fe, and it is suggested that the 13C-depleted carbonates may derive either from fermentative metabolism or from anaerobic respiration. A model is presented in which these processes occur near the sediment-water interface and are coupled with an initial oxidative precipitation of the iron.

NASA Program Exobiology↗

Constraints on Triple Oxygen Isotope Kinetics

Triple oxygen isotope methods (e.g., using δ 18 O, and Δ′ 17 O) have been used to classify meteorites, to constrain atmospheric chemistry, and to estimate primary productivity, among other uses. Such utility relies on the mass dependency of most chemical reactions: δ 17 O is proportional to δ 18 O by roughly a factor of 0.5. However, in detail, mass-dependency factors vary. While constraints on mass dependency are well established for equilibrium isotope effects, similar constraints for kinetic isotope effects are lacking. Using an ab initio Monte Carlo approach (see envelopes in Figure 1), we find the range of kinetic isotope effects (i.e., resulting from unidirectional chemical reactions) contains and exceeds the range of accessible equilibrium isotope effects for the 16 O 17 O 18 O system (Hayles and Killingsworth, 2022). Accessible kinetic isotope effects can yield Δ′ 17 O variations as large 0.8 ‰ from a single kinetic fractionation step. Reactions that yield the largest deviations from equilibrium are those with the largest molecular mass difference between decomposition fragments, typically the two products such as a gas and solid generated from the thermal decomposition of an initial solid. Comparison of DFT transition state model results against previously published experiments on the thermal decomposition of calcite (CaCO 3 ) (Miller et al., 2002) and dehydroxylation of brucite (Mg(OH) 2 ) (Clayton and Mayeda, 2009) show they are matched with mass-dependent kinetic isotope effects. This approach can be applied to any system with more than two isotopes.

Oxygen isotopes↗

Ion Mobility Mass Spectrometry Direct Isotope Abundance Analysis

The nuclear forensics community is currently engaged in the analysis of illicit nuclear or radioactive material for the purposes of non-proliferations and attribution. One technique commonly employed for gathering nuclear forensics information is isotope analysis. At present, the state-of-the-art methodology for obtaining isotopic distributions is thermal ionization mass spectrometry (TIMS). Although TIMS is highly accurate at determining isotope distributions, the technique requires an elementally pure sample to perform the measurement. The required radiochemical separations give rise to sample preparation times that can be in excess of one to two weeks. Clearly, the nuclear forensics community is in need of instrumentation and methods that can expedite their decision making process in the event of a radiological release or nuclear detonation. Accordingly, we are developing instrumentation that couples a high resolution IM drift cell to the front end of a MS. The IM cell provides a means of separating ions based upon their collision cross-section and mass-to-charge ratio (m/z). Two analytes with the same m/z, but with different collision cross-sections (shapes) would exit the cell at different times, essentially enabling the cell to function in a similar manner to a gas chromatography (GC) column. Thus, molecular and atomic isobaric interferences can be effectively removed from the ion beam. The mobility selected chemical species could then be introduced to a MS for high-resolution mass analysis to generate isotopic distributions of the target analytes. The outcome would be an IM/MS system capable of accurately measuring isotopic distributions while concurrently eliminating isobaric interferences and laboratory radiochemical sample preparation. The overall objective of this project is developing instrumentation and methods to produce near real-time isotope distributions with a modular mass spectrometric system that performs the required gas-phase chemistry and separations. The system couples a high-resolution ion mobility (IM) drift cell to the front end of a mass spectrometer (MS) allowing for chemical separation prior to isotope distribution analyses. This will yield isotope ratio measurement capabilities with minimal sample preparation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovery of the calcium, indium, tin, and platinum isotopes

Currently, twenty-four calcium, thirty-eight indium, thirty-eight tin, and thirty-nine platinum isotopes have been observed and the discovery of these isotopes is discussed here. For each isotope a brief synopsis of the first refereed publication, including the production and identification method, is presented. - Highlights: Documentation of the discovery of all calcium, indium, tin and platinum isotopes. {yields} Summary of author, journal, year, place and country of discovery for each isotope. {yields} Brief description of discovery history of each isotope.

07 ISOTOPE AND RADIATION SOURCES↗

Isotope Enrichment Detection by Laser Ablation - Laser Absorption Spectrometry: Automated Environmental Sampling and Laser-Based Analysis for HEU Detection

The global expansion of nuclear power, and consequently the uranium enrichment industry, requires the development of new safeguards technology to mitigate proliferation risks. Current enrichment monitoring instruments exist that provide only yes/no detection of highly enriched uranium (HEU) production. More accurate accountancy measurements are typically restricted to gamma-ray and weight measurements taken in cylinder storage yards. Analysis of environmental and cylinder content samples have much higher effectiveness, but this approach requires onsite sampling, shipping, and time-consuming laboratory analysis and reporting. Given that large modern gaseous centrifuge enrichment plants (GCEPs) can quickly produce a significant quantity (SQ ) of HEU, these limitations in verification suggest the need for more timely detection of potential facility misuse. The Pacific Northwest National Laboratory (PNNL) is developing an unattended safeguards instrument concept, combining continuous aerosol particulate collection with uranium isotope assay, to provide timely analysis of enrichment levels within low enriched uranium facilities. This approach is based on laser vaporization of aerosol particulate samples, followed by wavelength tuned laser diode spectroscopy to characterize the uranium isotopic ratio through subtle differences in atomic absorption wavelengths. Environmental sampling (ES) media from an integrated aerosol collector is introduced into a small, reduced pressure chamber, where a focused pulsed laser vaporizes material from a 10 to 20-µm diameter spot of the surface of the sampling media. The plume of ejected material begins as high-temperature plasma that yields ions and atoms, as well as molecules and molecular ions. We concentrate on the plume of atomic vapor that remains after the plasma has expanded and then cooled by the surrounding cover gas. Tunable diode lasers are directed through this plume and each isotope is detected by monitoring absorbance signals on a shot-to-shot basis. The media is translated by a micron resolution scanning system, allowing the isotope analysis to cover the entire sample surface. We also report, to the best of our knowledge, the first demonstration of laser-based isotopic measurements on individual micron-sized particles that are minor target components in a much larger heterogeneous mix of ‘background’ particles. This composition is consistent with swipe and environmental aerosol samples typically collected for safeguards ES purposes. Single-shot detection sensitivity approaching the femtogram range and relative isotope abundance uncertainty better than 10% has been demonstrated using gadolinium isotopes as surrogate materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Cr, Se, U, Sb, and Te isotopes as indicators of redox reactions, contaminant fate, and contaminant transport in aqueous systems: A review

Cr, Se, U, Sb, and Te are toxic, redox-active elements that are more mobile and environmentally problematic in their oxidized forms, and less mobile and bioavailable in their reduced forms. This chapter reviews the development of Cr, Se, U, Sb, and Te isotope ratio measurements as new indicators of redox reactions and contaminant migration. Reliable analytical methods exist, but are still evolving. Understanding of isotopic fractionation induced by various (bio)geochemical processes has been explored in dozens of publications, yet is far from complete: Reduction reactions, the major driver of isotopic variation, have been relatively well studied. However, the magnitude of fractionation is variable and the systematics of that variation are still being explored. Isotopic fractionation induced by oxidation reactions is not well understood. Non-redox reactions, which involve smaller changes in bonding of these elements, tend to induce less isotopic fractionation, but can nonetheless cause significant isotopic shifts. Field applications of Cr, Se, U isotope ratios have demonstrated that they are useful as indicators of reduction in natural systems. A few studies suggest they are also useful as indicators of oxidation and contaminant sources. The physical and chemical complexity of groundwater systems hinders accurate quantitative interpretation of Cr, Se, U isotope data using simple models. Numerical models have been developed that capture the behavior of complex, coupled systems and enable the most effective extraction of information from field data sets.

58 GEOSCIENCES↗

Linking cases of illegal shootings of the endangered California condor using stable lead isotope analysis

Lead poisoning is preventing the recovery of the critically endangered California condor (Gymnogyps californianus) and lead isotope analyses have demonstrated that ingestion of spent lead ammunition is the principal source of lead poisoning in condors. Over an 8 month period in 2009, three lead-poisoned condors were independently presented with birdshot embedded in their tissues, evidencing they had been shot. No information connecting these illegal shooting events existed and the timing of the shooting(s) was unknown. Using lead concentration and stable lead isotope analyses of feathers, blood, and recovered birdshot, we observed that: i) lead isotope ratios of embedded shot from all three birds were measurably indistinguishable from each other, suggesting a common source; ii) lead exposure histories re-constructed from feather analysis suggested that the shooting(s) occurred within the same timeframe; and iii) two of the three condors were lead poisoned from a lead source isotopically indistinguishable from the embedded birdshot, implicating ingestion of this type of birdshot as the source of poisoning. One of the condors was subsequently lead poisoned the following year from ingestion of a lead buckshot (blood lead 556 µg/dL), illustrating that ingested shot possess a substantially greater lead poisoning risk compared to embedded shot retained in tissue (blood lead ∼20 µg/dL). To our knowledge, this is the first study to use lead isotopes as a tool to retrospectively link wildlife shooting events. - Highlights: • We conducted a case-based analysis of illegal shootings of California condors. • Blood and feather Pb isotopes were used to reconstruct the illegal shooting events. • Embedded birdshot from the three condors had the same Pb isotope ratios. • Feather and blood Pb isotopes indicated that the condors were shot in a common event. • Ingested shot causes substantially greater lead exposure compared to embedded shot.

54 ENVIRONMENTAL SCIENCES↗

Samarium isotope compositions of uranium ore concentrates: A novel nuclear forensic signature

Uranium ore is mined and milled to produce uranium ore concentrate (UOC), a regulated product of the nuclear fuel cycle. Additionally, diversion of UOC from the fuel cycle into possible weapons production is a key concern in global nonproliferation efforts. As such, the ability to trace the origin of seized nuclear materials is imperative to law enforcement efforts. Although isotopic signatures of UOCs have proven fruitful to pinpoint sample provenance, new isotopic signatures are needed because most existing isotopic signatures are not indicative of the original ore body from which the U is derived. In this work, we developed a new method to separate samarium (Sm) from a U-rich sample matrix and report the first Sm isotope compositions of 32 UOCs derived from a variety of worldwide uranium mines. Relative to terrestrial standards, approximately half the UOCs have resolved and anticorrelated 149 Sm- 150 Sm isotope compositions, consistent with the capture of thermal neutrons by 149 Sm in the ore body. The UOCs with anomalous Sm isotope compositions tend to derive from older (~>1.5Ga) and higher-grade ore bodies, although other factors, such as the presence of neutron moderators like water, also play a role. Nonetheless, the Sm isotope compositions of UOCs directly reflects the neutron fluence over the history of the original ore body and can be used to discern different geologic conditions associated with that ore body. Overall, this work demonstrates the potential use of Sm isotopes as a novel nuclear forensics signature for origin assessment of UOCs.

58 GEOSCIENCES↗

Characterization of methane oxidation in a simulated landfill cover system by comparing molecular and stable isotope mass balances

Highlights: • Quantification of bacterial methane oxidation was investigated by isotope analysis. • Independent approaches (mass balancing, stoichiometry, and stable isotope analysis). • Robust statistical validation of calculated biodegradation in experimental reactor. • Thermal imaging to locate bacterial methane oxidation along with isotope analysis. - Abstract: Biological methane oxidation may be regarded as a method of aftercare treatment for landfills to reduce climate relevant methane emissions. It is of social and economic interest to estimate the behavior of bacterial methane oxidation in aged landfill covers due to an adequate long-term treatment of the gas emissions. Different approaches assessing methane oxidation in laboratory column studies have been investigated by other authors recently. However, this work represents the first study in which three independent approaches, ((i) mass balance, (ii) stable isotope analysis, and (iii) stoichiometric balance of product (CO{sub 2}) and reactant (CH{sub 4}) by CO{sub 2}/CH{sub 4}-ratio) have been compared for the estimation of the biodegradation by a robust statistical validation on a rectangular, wide soil column. Additionally, an evaluation by thermal imaging as a potential technique for the localization of the active zone of bacterial methane oxidation has been addressed in connection with stable isotope analysis and CO{sub 2}/CH{sub 4}-ratios. Although landfills can be considered as open systems the results for stable isotope analysis based on a closed system correlated better with the mass balance than calculations based on an open system. CO{sub 2}/CH{sub 4}-ratios were also in good agreement with mass balance. In general, highest values for biodegradation were determined from mass balance, followed by CO{sub 2}/CH{sub 4}-ratio, and stable isotope analysis. The investigated topsoil proved to be very suitable as a potential cover layer by removing up to 99% of methane for CH{sub 4} loads of 35–65 g m{sup –2} d{sup –1} that are typical in the aftercare phase of landfills. Finally, data from stable isotope analysis and the CO{sub 2}/CH{sub 4}-ratios were used to trace microbial activity within the reactor system. It was shown that methane consumption and temperature increase, as a cause of high microbial activity, correlated very well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking Physicochemical Conditions of Evaporite Deposition by Stable Magnesium Isotopes: A Case Study of Late Permian Langbeinites

Magnesium isotopic compositions of evaporite deposits may record information concerning brine evolution during deposition. We report Mg isotopic values (δ 26 MgDSM3) measured from an evaporite deposit of langbeinite (K 2 Mg 2 (SO 4 ) 3 ) found in the Permian Salado Formation. We used these data to model Mg isotope fractionation between langbeinite and its parent brine. In addition, both measured and theoretical results are used to estimate precipitation temperature and interpret depositional environment. The Salado langbeinite δ 26 Mg values are relatively low and fall within a relatively narrow range (–4.12 ± 0.03‰ to -3.81 ± 0.07‰). Equilibrium fractionation factors between langbeinite and aqueous Mg 2+ solutions were calculated using quantum chemical density functional theory. All computations were performed at the B3LYP/6-31 + G(d,p) level. Solvation effects were addressed using a solvent model (“water-droplet” approach) and mineral structures were investigated using volume variable cluster models (VVCM). The equilibrium Mg isotopic fractionation factors α between langbeinite and model brine solution we obtained are 1.0005, 1.0004, and 1.0003 (Δ 26 Mg langb-water ≈10 3 lnα = 0.473‰, 0.390‰, and 0.322‰) at 10°C, 25°C, and 40°C, respectively. These relatively large equilibrium fractionation factors indicate significant Mg isotope fractionation between langbeinite and its parent brine during precipitation, as langbeinite preferentially incorporates the heavier 26 Mg and 25 Mg isotopes. Rayleigh distillation modeling of the Salado langbeinite's relatively light Mg isotopic composition requires δ 26 Mg DSM3 values of -4‰ for the parent brine. Models favor a precipitation temperature as high as 40°C under equilibrium conditions. Finally, potential disequilibrium precipitation conditions suggested by Mg isotopic data also imply rapid deposition in a hot, arid sedimentary environment prevailing in the southwestern U.S. during the Late Permian.

58 GEOSCIENCES↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Isotope analysis of diamond-surface passivation effect of high-temperature H{sub 2}O-grown atomic layer deposition-Al{sub 2}O{sub 3} films

The Al{sub 2}O{sub 3} film formed using an atomic layer deposition (ALD) method with trimethylaluminum as Al precursor and H{sub 2}O as oxidant at a high temperature (450 °C) effectively passivates the p-type surface conduction (SC) layer specific to a hydrogen-terminated diamond surface, leading to a successful operation of diamond SC field-effect transistors at 400 °C. In order to investigate this excellent passivation effect, we carried out an isotope analysis using D{sub 2}O instead of H{sub 2}O in the ALD and found that the Al{sub 2}O{sub 3} film formed at a conventional temperature (100 °C) incorporates 50 times more CH{sub 3} groups than the high-temperature film. This CH{sub 3} is supposed to dissociate from the film when heated afterwards at a higher temperature (550 °C) and causes peeling patterns on the H-terminated surface. The high-temperature film is free from this problem and has the largest mass density and dielectric constant among those investigated in this study. The isotope analysis also unveiled a relatively active H-exchange reaction between the diamond H-termination and H{sub 2}O oxidant during the high-temperature ALD, the SC still being kept intact. This dynamic and yet steady H termination is realized by the suppressed oxidation due to the endothermic reaction with H{sub 2}O. Additionally, we not only observed the kinetic isotope effect in the form of reduced growth rate of D{sub 2}O-oxidant ALD but found that the mass density and dielectric constant of D{sub 2}O-grown Al{sub 2}O{sub 3} films are smaller than those of H{sub 2}O-grown films. This is a new type of isotope effect, which is not caused by the presence of isotopes in the films unlike the traditional isotope effects that originate from the presence of isotopes itself. Hence, the high-temperature ALD is very effective in forming Al{sub 2}O{sub 3} films as a passivation and/or gate-insulation layer of high-temperature-operation diamond SC devices, and the knowledge of the aforementioned new isotope effect will be a basis for further enhancing ALD technologies in general.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrared laser-induced isotope-selective dissociation of mixed (CF{sub 3}Br){sub m}Ar{sub n} van der Waals clusters

The paper presents the results of studies of IR laser-induced bromine-isotope-selective dissociation of small mixed (CF{sub 3}Br){sub m}Ar{sub n} van der Waals clusters (m = 1, 2 and 1 ≤ n ≤ 5 is the number of molecules and atoms in the clusters, respectively). The experiments used a pulsed CO{sub 2} laser to excite clusters and a quadrupole mass spectrometer to detect a molecular cluster beam. The research method is based on the selective vibrational excitation of clusters by IR laser radiation, leading to their predissociation. The possibilities of implementing bromine-isotope-selective dissociation of clusters are considered. The experimental setup and research method are briefly described. The results of determining the cluster dissociation efficiency and selectivity as functions of the energy and frequency of laser radiation are presented. It is shown that resonant vibrational excitation of clusters makes it possible to induce their isotope-selective dissociation. Thus, using a CF{sub 3}Br/Ar mixture with a pressure ratio of 1/200, the enrichment factors of the {sup 79}Br isotope are found to be K{sub enr}({sup 79}Br) = 1.15 ± 0.04 and 0.95 ± 0.03 under cluster irradiation conditions on the 9R(30) (ν = 1084.635 cm{sup −1}) and 9R(24) (ν = 1081.087 cm{sup −1}) lines, respectively The achieved dissociation selectivities for the clusters are, respectively, 1.16 ± 0.05 and 0.95 ± 0.04. The results obtained suggest that this method can be used to separate isotopes in molecules containing isotopes of heavy elements, which have a slight isotopic shift in the IR absorption spectra. (laser isotope separation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

C, N, AND O ISOTOPIC HETEROGENEITIES IN LOW-DENSITY SUPERNOVA GRAPHITE GRAINS FROM ORGUEIL

We report on the results of NanoSIMS isotope imaging of low-density supernova graphite grains from the Orgueil meteorite. 70 nm thick microtomed sections of three supernova graphite grains were deposited on Si wafers and isotopically imaged in the NanoSIMS. These sections contain hotspots of excesses in {sup 18}O and {sup 15}N, which are spatially well correlated, and are likely carried by internal TiC subgrains. These hotspots are considerably more enriched in {sup 18}O and {sup 15}N than the host graphite grain. Correlations between {sup 18}O and {sup 15}N excesses indicate that the grains incorporated material from the He/C supernova zone. Isotope images of the surfaces of some grains show heterogeneities in their N and O isotope compositions, with extreme excesses in {sup 15}N and {sup 18}O. In the microtome sections, we also observe two types of heterogeneities in the grains' C isotopic compositions: smooth, radial gradients in {sup 12}C/{sup 13}C, with this ratio trending toward solar with increasing radius; and highly anomalous pockets up to 2 {mu}m in size with {sup 12}C/{sup 13}C >> solar that are located near the centers of the grain sections. Partial isotopic equilibration does not likely explain the C isotopic heterogeneities. These grains and their constituent parts probably formed in a stellar environment with changing isotopic composition.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated isotope identification algorithm using artificial neural networks

There is a need to develop an algorithm that can determine the relative activities of radio-isotopes in a large dataset of low-resolution gamma-ray spectra that contains a mixture of many radio-isotopes. Low-resolution gamma-ray spectra that contain mixtures of radio-isotopes often exhibit feature over-lap, requiring algorithms that can analyze these features when overlap occurs. While machine learning and pattern recognition algorithms have shown promise for the problem of radio-isotope identification, their ability to identify and quantify mixtures of radio-isotopes has not been studied. Because machine learning algorithms use abstract features of the spectrum, such as the shape of overlapping peaks and Compton continuum, they are a natural choice for analyzing radio-isotope mixtures. An artificial neural network (ANN) has be trained to calculate the relative activities of 32 radio-isotopes in a spectrum. Furthermore, the ANN is trained with simulated gamma-ray spectra, allowing easy expansion of the library of target radio-isotopes. In this paper we present our initial algorithms based on an ANN and evaluate them against a series measured and simulated spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗