Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Effects of breast-air and breast-lung interfaces on the dose rate at the planning target volume of a MammoSite catheter for Yb-169 and Ir-192 HDR sources

Purpose: To study the effects of the breast-air and breast-lung interfaces on the absorbed dose within the planning target volume (PTV) of a MammoSite balloon dose delivery system as well as the effect of contrast material on the dose rate in the PTV. Methods: The Monte Carlo MCNP5 code was used to simulate dose rate in the PTV of a 2 cm radius MammoSite balloon dose delivery system. The simulations were carried out using an average female chest phantom (AFCP) and a semi-infinite water phantom for both Yb-169 and Ir-192 high dose rate sources for brachytherapy application. Gastrografin was introduced at varying concentrations to study the effect of contrast material on the dose rate in the PTV. Results: The effect of the density of the materials surrounding the MammoSite balloon containing 0% contrast material on the calculated dose rate at different radial distances in the PTV was demonstrated. Within the PTV, the ratio of the calculated dose rate for the AFCP and the semi-infinite water phantom for the point closest to the breast-air interface (90 deg.) is less than that for the point closest to the breast-lung interface (270 deg.) by 11.4% and 4% for the HDR sources of Yb-169 and Ir-192, respectively. When contrast material was introduced into the 2 cm radius MammoSite balloon at varying concentrations, (5%, 10%, 15%, and 20%), the dose rate in the AFCP at 3.0 cm radial distance at 90 deg. was decreased by as much as 14.8% and 6.2% for Yb-169 and Ir-192, respectively, when compared to that of the semi-infinite water phantom with contrast concentrations of 5%, 10%, 15%, and 20%, respectively. Conclusions: Commercially available software used to calculate dose rate in the PTV of a MammoSite balloon needs to account for patient anatomy and density of surrounding materials in the dosimetry analyses in order to avoid patient underdose.

60 APPLIED LIFE SCIENCES↗

Technical Note: Removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: A relevant and necessary step

Purpose: The purpose of this study was to investigate whether or not a stem effect removal technique is necessary when performing Ir-192 HDR brachytherapy in vivo dosimetry using a scintillation detector. Methods: A red-green-blue photodiode connected to a multichannel electrometer was used to detect the light emitted from a plastic scintillation detector (PSD) during irradiation with an Ir-192 HDR brachytherapy source. Accuracy in dose measurement was compared with and without the use of stem effect removal techniques. Monochromatic and polychromatic filtration techniques were studied. An in-house template was built for accurate positioning of catheters in which the source and the PSD were inserted. Dose distribution was measured up to 5 cm from source to detector in the radial and longitudinal directions. Results: The authors found the stem effect to be particularly important when the source was close to the optical fiber guide and far from the scintillation component of the detector. It can account for up to (72{+-}3)% of the signal under clinically relevant conditions. The polychromatic filtration outperformed the monochromatic filtration as well as the absence of filtration in regard to dose measurement accuracy. Conclusions: It is necessary to implement a stem effect removal technique when building a PSD for in vivo dosimetry during Ir-192 HDR brachytherapy. The PSD that the authors have developed for this study would be suitable for such an application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of air-kerma strength determinations for HDR {sup 192}Ir sources

Purpose: To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) {sup 192}Ir brachytherapy sources maintained by University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. Methods: The improved, laser-aligned seven-distance apparatus of University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR {sup 192}Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the {sup 192}Ir air-kerma calibration coefficient from the NIST air-kerma standards at {sup 137}Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A{sub wall} for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. Results: The average measurements when using the inverse N{sub K} interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Conclusions: Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that it is not necessary to update the current standard maintained at the UWADCL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sci—Fri AM: Mountain — 03: Current status of the NRC primary standard for {sup 192}Ir HDR brachytherapy sources

The Canadian primary standard for {sup 192}Ir HDR brachytherapy sources has been recently revised in a more accurate manner allowing for more realistic uncertainty estimation. Air-kerma strength S{sub k} is derived from measurements of the source's output using a graphite-walled spherical ionization chamber (2S) at several distances. Traceability to NRC primary standards for the {sup 192}Ir calibration coefficient N{sub k} is insured by estimating it as the inverse arithmetic mean of the inverse of the calibration coefficients for a {sup 137}Cs beam and the medium energy x-ray beam quality N250, both of which are traceable to NRC primary standards. The multiple-distance method is combined with a non-linear least squares fit to determine St, while at the same time removing the effects of room scatter and position offset. The previously used shadow-cone method for directly measuring the room scatter is found to be inadequate due to the increased scatter contribution from the lead cone itself, especially at short source-detector distances. Rather than including the reported 1% difference in source strength for {sup 192}Ir HDR sources of different construction into the total uncertainty, users are cautioned that the calibration coefficient provided by NRC is only valid for a microSelectron V2 model. A comprehensive uncertainty budged shows that the total one sigma uncertainty of the standard is actually 0.6% rather than the previously assumed 1.2%. NRC measured S{sub k} agrees within 0.03% of the manufacturer's value.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Software upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.

60 APPLIED LIFE SCIENCES↗

Enhanced thermoelectric performance of heavy-fermion compounds Yb TM 2 Zn 20 ( TM = Co, Rh, Ir) at low temperatures

Thermoelectricity allows direct conversion between heat and electricity, providing alternatives for green energy technologies. Despite these advantages, for most materials the energy conversion efficiency is limited by the tendency for the electrical and thermal conductivity to be proportional to each other and the Seebeck coefficient to be small. Here we report counter examples, where the heavy fermion compounds Yb TM 2 Zn 20 ( TM = Co, Rh, Ir) exhibit enhanced thermoelectric performance including a large power factor ( PF = 74 μW/cm-K 2 ; TM = Ir) and a high figure of merit ( ZT = 0.07; TM = Ir) at 35 K. The combination of the strongly hybridized electronic state originating from the Yb f -electrons and the novel structural features (large unit cell and possible soft phonon modes) leads to high power factors and small thermal conductivity values. This demonstrates that with further optimization these systems could provide a platform for the next generation of low temperature thermoelectric materials.

36 MATERIALS SCIENCE↗

Optical Constants of an Apatite Single Crystal in the IR Range of 6–28 μm

On the basis of polarized IR-reflection spectra in the range of 5000–350 cm{sup –1} measured from the natural face of an optically transparent fluorapatite single crystal, components of a complex refractive index (optical constants) for radiation-vector orientations E ‖ c and E ⊥ c have been calculated by the Kramers–Kronig method. The fluorapatite single crystal has been chosen from several samples: it contains a minimum amount of impurities and has a high degree of crystallinity in accordance with the criteria of IR spectroscopy and Raman spectroscopy. Tabular data on optical constants for ordinary and extraordinary rays are given for the IR range of 6–28 μm. The obtained absorption spectra are compared with the results of quantum-chemical ab initio calculations within the B3LYP simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the Inductive-Resonant Interaction of Water Clusters in Fluorapatite Minerals Using Polarization IR and Raman Spectroscopy

Polarization studies of the vibrational spectra of clusters (H{sub 2}O){sub n} in samples of single-crystal fluorapatite of different deposits were carried out by infrared (IR) spectroscopy and Raman spectroscopy. The IR and Raman spectra were measured for two orthogonal directions of the external excitation field: parallel and perpendicular to the c-channels in fluorapatite single crystals. Interpretation of the interaction of the external electromagnetic field with clusters of water situated in microvoids and microcracks of the crystal with the structural groups of F…HO of apatite is given in the framework of the dipole–dipole approximation. This interaction has an induction–resonance character (IR spectroscopy) caused by the transfer of vibrational excitation from the F…HO groups to (H{sub 2}O){sub n} clusters. In the case of Raman spectroscopy, the induction character of the excitation of (H{sub 2}O){sub n} clusters takes place due to the transfer of electron excitation from the F…HO groups.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the biphoton excitation of the fluorescence of the bacteriochlorophyll molecules of purple photosynthetic bacteria by powerful near IR femto-picosecond pulses

The authors of a number of experimental works detected nonresonance biphoton excitation of bacteriochlorophyll molecules, which represent the main pigment in the light-absorbing natural 'antenna' complexes of photosynthesizing purple bacteria, by femtosecond IR pulses (1250-1500 nm). They believe that IR quanta excite hypothetic forbidden levels of the pigments of these bacteria in the double frequency range 625-750 nm. We propose and ground an alternative triplet mechanism to describe this phenomenon. According to our hypothesis, the mechanism of biphoton excitation of molecules by IR quanta can manifest itself specifically, through high triplet levels of molecules in the high fields induced by femtosecond-picosecond laser pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Asymptotic freedom and IR freezing in QCD: the role of gluon paramagnetism

Paramagnetism of gluons is shown to play the basic role in establishing main properties of QCD: IR freezing and asymptotic freedom (AF). Starting with Polyakov background field approach the first terms of background perturbation theory are calculated and shown to ensure not only the classical result of AF but also IR freezing. For the latter only the confining property of the background is needed, and the effective mass entering the IR freezing logarithms is calculated in good agreement with phenomenology and lattice data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UV and IR emission intensity in ZnO films, nanorods, and bulk single crystals doped with Er and additionally introduced impurities

For ZnO films, nanorods, and bulk single crystals doped with Er{sup +} ions, it is shown that the effect of codopants introduced into the cation and ion sublattices and the observation of a high-intensity emission band at the wavelength λ{sub max} = 1535 nm are defined by the local environment of the Er{sup +} ion. Doping of the films and single crystals with Er{sup +} ions by diffusion brings about an infrared (IR) emission band with a low intensity because of an inadequate concentration of impurity ions. The emission intensity of this band can be raised by introducing additional Ag, Au, or N{sup +} impurities into the ZnO films. The UV-emission intensity of the Er-doped films and single crystals at λ{sub max} = 368–372 nm is identical to that of the undoped films. ZnO nanorods doped with Er only or together with Al or Ga codopants exhibit only one IR band (at λ{sub max} = 1535 nm), whose intensity decreases upon the introduction of codopants. Doping of the nanorods with the N{sup +} gaseous impurity during growth (930 < T < 960°C) and then with the Er{sup +} impurity by diffusion does not yield a substantial increase in the IR-emission intensity compared to the that of the corresponding band for nanorods not doped with the N{sup +} impurity. In the Er-doped nanorods, whose photoluminescence spectra exhibit a high-intensity band at λ{sub max} = 1535 nm, the UV emission band at λ{sub max} = 372 nm is practically lacking.

36 MATERIALS SCIENCE↗

IR spectra of carbon-vacancy clusters in the topochemical transformation of silicon into silicon carbide

Using infrared (IR) spectroscopy and spectral ellipsometry, we experimentally confirmed the previously predicted mechanochemical effect of the stoichiometric composition disorder leading to the formation of carbon-vacancy structures in silicon carbide (SiC) films grown on silicon substrates by the atom substitution method. It was found that a band at 960 cm{sup –1} in the IR spectra of SiC films on silicon, corresponding to “carbon-vacancy clusters” is always present in SiC films grown under pure carbon monoxide (CO) or in a mixture of CO with silane (SiH{sub 4}) on Si substrates of different orientation and doping level and type. There is no absorption band in the region of 960 cm–1 in the IR spectra of SiC films synthesized at the optimum ratio of the CO and trichlorosilane (SiHCl{sub 3}) gas pressures. The previously predicted mechanism of the chemical reaction of substitution of Si atoms for carbon by the interaction of gases CO and SiHCl{sub 3} on the surface of the silicon substrate, which leads to the formation of epitaxial layers of single-crystal SiC, is experimentally confirmed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using Higher-Order Modes of Chalcogenide Optical Fibers for the Optimization of Evanescent Wave Mid-IR Spectroscopy

On the basis of a new theoretical approach that is proposed for solving tasks of the evanescent wave mid-IR spectroscopy, it is shown that the dispersion properties of higher-order modes of a multimode chalcogenide optical fiber partly immersed into an absorbing medium can be used for the creation of fiber-optic devices combining the functions of a supercontinuum generator and a sensing element for mid-IR spectroscopic sensors. The propagation of radiation in higher-order modes makes it possible to control the position of zero dispersion of group velocity and to generate supercontinuum with near-IR pumping. Using higher-order evanescent modes in a sensing element, it will be possible to increase its sensitivity and expand the dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ High-Pressure Study of Ammonia Borane by Raman and IR Spectroscopy

Pressure-induced structural transformations of the ammonia borane complex (NH3{center_dot}BH3) were investigated in diamond anvil cells by Raman spectroscopy and synchrotron IR spectroscopy up to 14 GPa at room temperature. Starting with a disordered tetragonal structure, NH3{center_dot}BH3 is found to undergo several transformations upon compression as monitored by in situ Raman measurements. These transformations are indicated by the sequential changes of characteristic Raman modes as well as by the pressure dependence of these modes. Synchrotron IR absorption spectroscopy provided supplementary and consistent information about the structural evolution of NH3{center_dot}BH3 under compression. Decompression measurements on NH3{center_dot}BH3 suggest the pressure-induced transformations are reversible in the entire pressure region. The combined Raman and IR data allowed analysis of possible high-pressure structures of NH3{center_dot}BH3. Our study significantly complements previous high-pressure Raman studies by providing new information on the structures and stabilities of NH3{center_dot}BH3.

43 PARTICLE ACCELERATORS↗

IR Heat Treatment of Hybrid Steel-Al Joints

The technical objective of this CRADA is to develop and model a heat treatment process based on Infra- Red (IR) heating of a overcast Al/steel bimetallic joint to produce a T5 temper in a shorter period of time than is currently achievable and, separately, to produce a modified T6 temper for improved mechanical properties without the loss of joint integrity. IR heat treatments have been demonstrated to provide reduced processing time, reduced energy requirements, and improved material properties of Al components, including strength and elongation, relative to convective thermal heat treatment methods. A prototype IR furnace was assembled to heat treat these joints. The residual stress state of the joints were modeled in the as-cast condition, as well as the T5 and T6 condition. Neutrons were used to measure the residual stresses in the joints for various heat treatments. ORNL is uniquely equipped to partner with Vehma in the experimental evaluation and modeling of Al/steel bi-metallic joints. ORNL possesses a long history of microstructural, crystallographic and mechanical characterization of structural materials. Unique facilities at ORNL for this work include the NRSF2/HB-2B beamline at the High Flux Isotope Reactor (HFIR) for residual stress measurements with neutron diffraction, metallurgical expertise for heat treating and modeling capability of the manufacturing of these joints for residual stress prediction. All of these capabilities were utilized in this CRADA. The CRADA began in April 2011 and ended in September 2014 (41 months).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AXION DECAY AND ANISOTROPY OF NEAR-IR EXTRAGALACTIC BACKGROUND LIGHT

The extragalactic background light (EBL) is composed of the cumulative radiation from all galaxies and active galactic nuclei over cosmic history. In addition to point sources, the EBL also contains information from diffuse sources of radiation. The angular power spectra of the near-infrared intensities could contain additional signals, and a complete understanding of the nature of the infrared (IR) background is still lacking in the literature. Here we explore the constraints that can be placed on particle decays, especially candidate dark matter (DM) models involving axions that trace DM halos of galaxies. Axions with a mass around a few electronvolts will decay via two photons with wavelengths in the near-IR band and will leave a signature in the IR background intensity power spectrum. Using recent power spectra measurements from the Hubble Space Telescope and the Cosmic Infrared Background Experiment, we find that the 0.6–1.6 μ m power spectra can be explained by axions with masses around 4 eV. The total axion abundance Ω{sub a} ≃ 0.05, and it is comparable to the baryon density of the universe. The suggested mean axion mass and abundance are not ruled out by existing cosmological observations. Interestingly, the axion model with a mass distribution is preferred by the data, which cannot be explained by the standard quantum chromodynamics theory and needs further discussion.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SPECTACULAR RADIO-NEAR-IR-X-RAY JET OF 3C 111: THE X-RAY EMISSION MECHANISM AND JET KINEMATICS

Relativistic jets are the most energetic manifestation of the active galactic nucleus (AGN) phenomenon. AGN jets are observed from the radio through gamma-rays and carry copious amounts of matter and energy from the sub-parsec central regions out to the kiloparsec and often megaparsec scale galaxy and cluster environs. While most spatially resolved jets are seen in the radio, an increasing number have been discovered to emit in the optical/near-IR and/or X-ray bands. Here we discuss a spectacular example of this class, the 3C 111 jet, housed in one of the nearest, double-lobed FR II radio galaxies known. We discuss new, deep Chandra and Hubble Space Telescope ( HST ) observations that reveal both near-IR and X-ray emission from several components of the 3C 111 jet, as well as both the northern and southern hotspots. Important differences are seen between the morphologies in the radio, X-ray, and near-IR bands. The long (over 100 kpc on each side), straight nature of this jet makes it an excellent prototype for future, deep observations, as it is one of the longest such features seen in the radio, near-IR/optical, and X-ray bands. Several independent lines of evidence, including the X-ray and broadband spectral shape as well as the implied velocity of the approaching hotspot, lead us to strongly disfavor the EC/CMB model and instead favor a two-component synchrotron model to explain the observed X-ray emission for several jet components. Future observations with NuSTAR , HST , and Chandra will allow us to further constrain the emission mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗