Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

High operating temperature interband cascade focal plane arrays

In this paper, we report the initial demonstration of mid-infrared interband cascade (IC) photodetector focal plane arrays with multiple-stage/junction design. The merits of IC photodetectors include low noise and efficient photocarrier extraction, even for zero-bias operation. By adopting enhanced electron barrier design and a total absorber thickness of 0.7 μm, the 5-stage IC detectors show very low dark current (1.10 × 10{sup −7} A/cm{sup 2} at −5 mV and 150 K). Even with un-optimized fabrication and standard commercial (mis-matched) read-out circuit technology, infrared images are obtained by the 320 × 256 IC focal plane array up to 180 K with f/2.3 optics. The minimum noise equivalent temperature difference of 28 mK is obtained at 120 K. These initial results indicate great potential of IC photodetectors, particularly for high operating temperature applications.

36 MATERIALS SCIENCE↗

High duty cycle inverse Compton scattering X-ray source

Inverse Compton Scattering (ICS) is an emerging compact X-ray source technology, where the small source size and high spectral brightness are of interest for multitude of applications. However, to satisfy the practical flux requirements, a high-repetition-rate ICS system needs to be developed. To this end, this article reports the experimental demonstration of a high peak brightness ICS source operating in a burst mode at 40 MHz. A pulse train interaction has been achieved by recirculating a picosecond CO 2 laser pulse inside an active optical cavity synchronized to the electron beam. The pulse train ICS performance has been characterized at 5- and 15- pulses per train and compared to a single pulse operation under the same operating conditions. Lastly, with the observed near-linear X-ray photon yield gain due to recirculation, as well as noticeably higher operational reliability, the burst-mode ICS offers a great potential for practical scalability towards high duty cycles.

43 PARTICLE ACCELERATORS↗

SECONDARY RADIATION FROM THE PAMELA/ATIC EXCESS AND RELEVANCE FOR FERMI

The excess of electrons/positrons observed by the Pamela and ATIC experiments gives rise to a noticeable amount of synchrotron and inverse Compton scattering (ICS) radiation when the e {sup +} e {sup -} interact with the Galactic magnetic field, and the interstellar radiation field (ISRF). In particular, the ICS signal produced within the weakly interacting, massive particle annihilation interpretation of the Pamela/ATIC excess shows already some tension with the EGRET data. On the other hand, one year of Fermi data taking will be enough to rule out or confirm this scenario with a high confidence level. The ICS radiation produces a peculiar and clean 'ICS Haze' feature, as well, which can be used to discriminate between the astrophysical and dark matter (DM) scenarios. This ICS signature is very prominent even several degrees away from the galactic center, and it is thus a very robust prediction with respect to the choice of the DM profile and the uncertainties in the ISRF.

99 GENERAL AND MISCELLANEOUS↗

CORE-COLLAPSE SUPERNOVAE FROM THE PALOMAR TRANSIENT FACTORY: INDICATIONS FOR A DIFFERENT POPULATION IN DWARF GALAXIES

We use the first compilation of 72 core-collapse supernovae (SNe) from the Palomar Transient Factory (PTF) to study their observed subtype distribution in dwarf galaxies compared to giant galaxies. Our sample is the largest single-survey, untargeted, spectroscopically classified, homogeneous collection of core-collapse events ever assembled, spanning a wide host-galaxy luminosity range (down to M{sub r} {approx} -14 mag) and including a substantial fraction (>20%) of dwarf (M{sub r} {>=} -18 mag) hosts. We find more core-collapse SNe in dwarf galaxies than expected and several interesting trends emerge. We use detailed subclassifications of stripped-envelope core-collapse SNe and find that all Type I core-collapse events occurring in dwarf galaxies are either SNe Ib or broad-lined SNe Ic (SNe Ic-BL), while 'normal' SNe Ic dominate in giant galaxies. We also see a significant excess of SNe IIb in dwarf hosts. We hypothesize that in lower metallicity hosts, metallicity-driven mass loss is reduced, allowing massive stars that would have appeared as 'normal' SNe Ic in metal-rich galaxies to retain some He and H, exploding as Ib/IIb events. At the same time, another mechanism allows some stars to undergo extensive stripping and explode as SNe Ic-BL (and presumably also as long-duration gamma-ray bursts). Our results are still limited by small-number statistics, and our measurements of the observed N(Ib/c)/N(II) number ratio in dwarf and giant hosts (0.25{sup +0.3}{sub -0.15} and 0.23{sup +0.11}{sub -0.08}, respectively; 1{sigma} uncertainties) are consistent with previous studies and theoretical predictions. As additional PTF data accumulate, more robust statistical analyses will be possible, allowing the evolution of massive stars to be probed via the dwarf-galaxy SN population.

79 ASTRONOMY AND ASTROPHYSICS↗

Effectiveness of supervised exercise, home-based exercise, or walk advice strategies on walking performance and muscle endurance in patients with intermittent claudication (SUNFIT trial): a randomized clinical trial

Abstract Aims Supervised exercise is a guideline-recommended treatment in intermittent claudication (IC). Hospital-based supervised exercise programmes (SEPs) are underutilized, while home-based structured exercise programmes (HSEPs) have attracted interest. The results from HSEP in IC are inconsistent and may confer no benefit over walk advice (WA) and be less effective than SEP. The aim of the study was to compare the effectiveness of best medical treatment, including Nordic pole WA alone, or WA + SEP or WA + HSEP for patients with IC. Methods and results This three-armed, multicentre randomized clinical trial enrolled patients with IC; all patients received best medical treatment including walking poles and the advice of regular Nordic pole walking (WA). For HSEP and SEP, additional exercise programmes were provided. The primarily investigated hypothesis was a non-inferiority analysis of SEP vs. HSEP regarding the 6-min walk test (6MWT) maximum distance, with a pre-defined non-inferiority margin of 50 m. Supporting outcomes included muscle endurance tests and the walking impairment questionnaire. Outcomes were assessed at baseline, 3, 6, and 12 months by a blinded evaluator. Altogether 166 patients (mean age 72 years; 59% males) were randomized. In HSEP and SEP, 24 and 26% patients, respectively, were fully exercise adherent. All three groups improved pain-free walking distance over time, but there were no significant intergroup differences. The intergroup 6MWT difference between SEP and HSEP from 0 to 12 months was –11.6 m, 95% confidence interval: –36.4 to 13.0 m (i.e. within the pre-specified non-inferiority margin). Conclusion The HSEP was non-inferior to SEP in patients with IC. There were no significant differences observed between the three groups at 1 year. Registration ClinicialTrials.gov: NCT02341716.

Sandberg, Anna (ORCID:0000000258432784)↗

Synchrotron self-Compton radiation from magnetically dominated turbulent plasmas in relativistic jets

ABSTRACT Relativistic jets launched by rotating black holes are powerful emitters of non-thermal radiation. Extraction of the rotational energy via electromagnetic stresses produces magnetically dominated jets, which may become turbulent. Studies of magnetically dominated plasma turbulence from first principles show that most of the accelerated particles have small pitch angles, i.e. the particle velocity is nearly aligned with the local magnetic field. We examine synchrotron self-Compton radiation from anisotropic particles in the fast cooling regime. The small pitch angles reduce the synchrotron cooling rate and promote the role of inverse Compton (IC) cooling, which can occur in two different regimes. In the Thomson regime, both synchrotron and IC components have soft spectra, νFν ∝ ν1/2. In the Klein–Nishina regime, synchrotron radiation has a hard spectrum, typically νFν ∝ ν, over a broad range of frequencies. Our results have implications for the modelling of BL Lacertae objects (BL Lacs) and gamma-ray bursts (GRBs). BL Lacs produce soft synchrotron and IC spectra, as expected when Klein–Nishina effects are minor. The observed synchrotron and IC luminosities are typically comparable, which indicates a moderate anisotropy with pitch angles θ ≳ 0.1. Rare orphan gamma-ray flares may be produced when θ ≪ 0.1. The hard spectra of GRBs may be consistent with synchrotron radiation when the emitting particles are IC cooling in the Klein–Nishina regime, as expected for pitch angles θ ∼ 0.1. Blazar and GRB spectra can be explained by turbulent jets with a similar electron plasma magnetization parameter, σe ∼ 104, which for electron–proton plasmas corresponds to an overall magnetization σ = (me/mp)σe ∼ 10.

79 ASTRONOMY AND ASTROPHYSICS↗

Primordial non-Gaussianity with angular correlation function: integral constraint and validation for DES

ABSTRACT Local primordial non-Gaussianity (PNG) is a promising observable of the underlying physics of inflation, characterized by $f_{\rm NL}^{\rm loc}$. We present the methodology to measure $f_{\rm NL}^{\rm loc}$ from the Dark Energy Survey (DES) data using the two-point angular correlation function (ACF) with scale-dependent bias. One of the focuses of the work is the integral constraint (IC). This condition appears when estimating the mean number density of galaxies from the data and is key in obtaining unbiased $f_{\rm NL}^{\rm loc}$ constraints. The methods are analysed for two types of simulations: ∼246 goliat-png N-body small area simulations with fNL equal to −100 and 100, and 1952 Gaussian ice-cola mocks with fNL = 0 that follow the DES angular and redshift distribution. We use the ensemble of goliat-png mocks to show the importance of the IC when measuring PNG, where we recover the fiducial values of fNL within the 1σ when including the IC. In contrast, we found a bias of ΔfNL ∼ 100 when not including it. For a DES-like scenario, we forecast a bias of ΔfNL ∼ 23, equivalent to 1.8σ, when not using the IC for a fiducial value of fNL = 100. We use the ice-cola mocks to validate our analysis in a realistic DES-like set-up finding it robust to different analysis choices: best-fitting estimator, the effect of IC, BAO damping, covariance, and scale choices. We forecast a measurement of fNL within σ(fNL) = 31 when using the DES-Y3 BAO sample, with the ACF in the 1 deg < θ < 20 deg range.

79 ASTRONOMY AND ASTROPHYSICS↗

Internal-conversion process in superintense ultrashort x-ray pulses

The electron-nucleus interaction in a super-intense few-cycle x-ray pulse is investigated. The super-intense few-cycle x-ray pulse-induced internal conversion (IC) process is discussed in detail. The x-ray laser-pulse induced IC coefficient is calculated, and in particular, it is derived in the case of a pulse of Gaussian shape and for a bound-free electron transition. The IC coefficient of the IC process induced by a super-intense few-cycle soft-x-ray laser pulse in the case of the {sup 99m}Tc isomer is determined numerically. The results obtained for the IC coefficient show significant carrier angular frequency, carrier-envelope phase, and pulse-length dependencies. The infinite pulse-length limit and experimental aspects are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New limits on intrinsic charm in the nucleon from global analysis of parton distributions

We present a new global QCD analysis of parton distribution functions, allowing for possible intrinsic charm (IC) contributions in the nucleon inspired by light-front models. The analysis makes use of the full range of available high-energy scattering data for Q 2 ≥ 1 GeV 2 and W 2 ≥ 3.5 GeV 2 , including fixed-target proton and deuteron deep cross sections at lower energies that were excluded in previously global analyses. The expanded data set places more stringent constraints on the momentum carried by IC, with (x) IC at most 0.5% (corresponding to an IC normalization of ~1%) at the 4σ level for Δ X 2 = 1. We also assess the impact of older EMC measurements of F c 2 c at large x, which favor a nonzero IC, but with very large X 2 values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Implementation of Full-Scale Industrial Control System Test Bed for Assessing Cyber-Security Defenses

In response to the increasing awareness of the Ethernet-based threat surface of industrial control systems (ICS), both the research and commercial communities are responding with ICS-specific security solutions. Unfortunately, many of the properties of ICS environments that contribute to the extent of this threat surface (e.g. age of devices, inability or unwillingness to patch, criticality of the system) similarly prevent the proper testing and evaluation of these security solutions. Production environments are often too fragile to introduce unvetted technology and most organizations lack test environments that are sufficiently consistent with production to yield actionable results. Cost and space requirements prevent the creation of mirrored physical environments leading many to look towards simulation or virtualization. Examples in literature provide various approaches to building ICS test beds, though most of these suffer from a lack of realism due to contrived scenarios, synthetic data and other compromises. In this paper, we provide a design methodology for building highly realistic ICS test beds for validating cybersecurity defenses. We then apply that methodology to the design and building of a specific test bed and describe the results and experimental use cases.

Gillen, Rob↗

Apparent fracture toughness estimation of additively manufactured alumina from as-printed chevron-notched test specimens

Ceramic vat photopolymerization (VPP) is a digital light processing method used to make additively manufactured green ceramic components that are then sintered. Despite the ever-advancing maturation of this method's green-state process, some of the material properties of sintered VPP-processed ceramics are still not well defined or understood. One example is Mode I fracture toughness, K Ic . In this study, attention was devoted to K Ic measurement using net-shape chevron-notched bend bars that were VPP-processed and the examination of whether valid K Ic measurement could occur by testing them. Further, stable crack propagation was observed in >60% of tested samples, indicated by a smooth nonlinear transition through the measured maximum force prior to final fracture. However, their results cannot yet be responsibly referred to as K Ic because of continuing violations of other prerequisites needed for valid K Ic testing.

36 MATERIALS SCIENCE↗

Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore, volume averaging of the IC can be observed for the 5 mm aperture where it differs by as much as 9.1% compared to the PSD measurement. The angular dependency of the UD is also observed, unveiled by an under-response around 2.5% of both 5 and 35 mm apertures. Conclusions: Output Factors and dose profiles measurements performed, respectively, with the PSD and the PSDCA were in agreement with those obtained with the UD and EBT2 films. For stereotactic radiosurgery treatment verification, the PSD gives accurate results compared to the planning system and the IC once the latter is corrected to compensate for the averaging effect of the IC. The PSD provides precise results when used as a single detector or in a dense array, resulting in a great potential for stereotactic radiosurgery QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-J-01: Effect of Iodine Contrast Agent Concentration On Cerebrovascular Dose for Synchrotron Radiation Microangiography Based On a Simple Mouse Head Model and a Voxel Mouse Head Phantom

Purpose: To find effective setting methods to mitigate the irradiation injure in synchrotron radiation microangiography(SRA) by Monte Carlo simulation. Methods: A mouse 1-D head model and a segmented voxel mouse head phantom were simulated by EGSnrc/Dosxyznrc code to investigate the dose enhancement effect of the iodine contrast agent irradiated by a monochromatic synchrotron radiation(SR) source. The influence of, like iodine concentration (IC), vessel width and depth, with and without skull layer protection and the various incident X ray energies, were simulated. The dose enhancement effect and the absolute dose based on the segmented voxel mouse head phantom were evaluated. Results: The dose enhancement ratio depends little on the irradiation depth, but strongly on the IC, which is linearly increases with IC. The skull layer protection cannot be ignored in SRA, the 700µm thick skull could decrease 10% of the dose. The incident X-ray energy can significantly affact the dose. E.g. compared to the dose of 33.2keV for 50mgI/ml, the 32.7keV dose decreases 38%, whereas the dose of 33.7 keV increases 69.2%, and the variation will strengthen more with enhanced IC. The segmented voxel mouse head phantom also showed that the average dose enhancement effect and the maximal voxel dose per photon depends little on the iodine voxel volume ratio, but strongly on IC. Conclusion: To decrease dose damage in SRA, the high-Z contrast agent should be used as little as possible, and try to avoid radiating locally the injected position immediately after the contrast agent injection. The fragile vessel containing iodine should avoid closely irradiating. Avoiding irradiating through the no or thin skull region, or appending thin equivalent material from outside to protect is also a better method. As long as SRA image quality is ensured, using incident X-ray energy as low as possible.

60 APPLIED LIFE SCIENCES↗

SU-F-T-71: A Practical Method for Evaluation of Electron Virtual Source Position

Purpose: Since electrons are easily scattered, the virtual source position for electrons is expected to locate below the x-ray target of Medical Linacs. However, the effective SSD method yields the electron virtual position above the x-ray target for some applicators for some energy in Siemens Linacs. In this study, we propose to use IC Profiler (Sun Nuclear) for evaluating the electron virtual source position for the standard electron applicators for various electron energies. Methods: The profile measurements for various nominal source-to-detector distances (SDDs) of 100–115 cm were carried out for electron beam energies of 6–18 MeV. Two methods were used: one was to use a 0.125 cc ion chamber (PTW, Type 31010) with buildup mounted in a PTW water tank without water filled; and the other was to use IC Profiler with a buildup to achieve charge particle equilibrium. The full width at half-maximum (FWHM) method was used to determine the field sizes for the measured profiles. Backprojecting (by a straight line) the distance between the 50% points on the beam profiles for the various SDDs, yielded the virtual source position for each applicator. Results: The profiles were obtained and the field sizes were determined by FWHM. The virtual source positions were determined through backprojection of profiles for applicators (5, 10, 15, 20, 25). For instance, they were 96.415 cm (IC Profiler) vs 95.844 cm (scanning ion chamber) for 9 MeV electrons with 10×10 cm applicator and 97.160 cm vs 97.161 cm for 12 MeV electrons with 10×10 cm applicator. The differences in the virtual source positions between IC profiler and scanning ion chamber were within 1.5%. Conclusion: IC Profiler provides a practical method for determining the electron virtual source position and its results are consistent with those obtained by profiles of scanning ion chamber with buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Density Gradient Evolution Effect on Ion Cyclotron Waves Excitation in TUMAN-3M Tokamak Ohmic Discharges

In TUMAN-3M tokamak ohmic hydrogen and deuterium discharges oscillations with ion cyclotron (IC) frequency were detected. Fast magnetic probes poloidal array in TUMAN-3M is capable of detecting several harmonics of IC frequency of main plasma isotope. Fuel pellet injection significantly reduces IC oscillations intensity, though after complete pellet evaporation returns to initial level. IC oscillations localization and excitation conditions are of certain interest. Based on drift-cyclotron instability excitation theory and numerical modeling of scenarios with ohmic LH-transition and pellet-injection plasma parameters (density gradient primarily) effect on IC oscillations excitation was studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Electrochemical Charging on Elastoplastic Properties and Fracture Toughness of Li X CoO 2

Mechanical degradation of lithium-ion battery (LIB) electrodes has been correlated with capacity fade and impedance growth over repeated charging and discharging. Knowledge of how the mechanical properties of materials used in LIBs are affected by electrochemical lithiation and delithiation could provide insight into design choices that mitigate mechanical damage and extend device lifetime. Here, we measured Young's modulus E, hardness H, and fracture toughness K Ic via instrumented nanoindentation of the prototypical intercalation cathode, Li X CoO 2 , after varying durations of electrochemical charging. After a single charge cycle, E and H decreased by up to 60%, while K Ic decreased by up to 70%. Microstructural characterization using optical microscopy, Raman spectroscopy, X-ray diffraction, and further nanoindentation showed that this degradation in K Ic was attributable to Li depletion at the material surface and was also correlated with extensive microfracture at grain boundaries. These results indicate that K Ic reduction and irreversible microstructural damage occur during the first cycle of lithium deintercalation from polycrystalline aggregates of Li X CoO 2 , potentially facilitating further crack growth over repeated cycling. Such marked reduction in K Ic over a single charge cycle also yields important implications for the design of electrochemical shock-resistant cathode materials.

36 MATERIALS SCIENCE↗