Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hybrid systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Magnon-magnon coupling in an all-oxide insulator garnet Y 3 ⁢Fe 5 ⁢O 12 /Tm 3 ⁢Fe 5⁢ O 12 heterostructure

Hybrid magnonic systems have recently attracted significant attention due to their intriguing physics and potential applications in coherent information processing. In this regard, we have investigated magnon-magnon coupling in the all-oxide insulator garnet Y 3⁢ Fe 5⁢ O 12 (YIG)/Tm 3 ⁢Fe 5 ⁢O 12 (TmIG) heterostructure. The presence of an avoided mode crossing region between the ferromagnetic resonance modes of YIG and TmIG indicates interfacial exchange coupling. This all-insulator system enables interfacial coupling via magnon-magnon interactions. The mode crossing occurs at 𝑓 𝑐 = 6.88 GHz, corresponding to the minimal resonance separation between the two hybrid modes. The coupling strength is determined to be 78 MHz (or 2.8 mT), providing clear evidence of magnon-magnon coupling between the two Kittel modes in the YIG/TmIG insulator system at 200 K. As a result, these findings pave the way for engineering magnonic band structures, tunable coherent magnonic interactions, and nonreciprocal spin transport, which are crucial for advancing ultralow-power magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis and Overview of Hybrid Wired and Wireless Bi-Directional EV Charger Systems

Here, this paper analyzes and overviews hybrid wired and wireless bi-directional Electric Vehicle (EV) charging systems with a primary focus on resonant compensation methods that enable a unified power conversion architecture. Four compensation configurations based on series–series and LCC–LCC resonant networks are systematically evaluated for both wired transformer-based and wireless coupler-based operation. The analysis examines how coupling conditions, resonant component selection, and auxiliary compensation tuning influence voltage gain characteristics, resonant tank current magnitude and phase, and operating frequency requirements. Normalized frequency-domain results are presented to directly compare reactive current behavior and voltage regulation capability under wired and wireless operating conditions. A 60 kW bi-directional charger case study is used to demonstrate the feasibility of retaining a common hardware platform while accommodating distinct coupling scenarios through compensation tuning rather than structural modification. The presented results provide design-oriented insights into resonant network selection and compensation strategies for scalable and flexible hybrid EV charging systems.

Hybrid↗

Systems and methods for online power management for hybrid powertrains

At least some embodiments of the present disclosure are directed to systems and methods of online power management for hybrid powertrains. In some embodiments, the hybrid powertrain control system is configured to conduct a brake-thermal-efficiency (BTE) estimation procedure when the powertrain is in operation by operating the hybrid powertrain at a plurality of speeds for a plurality of designated power levels and select certain BTE operating conditions to update the power management.

Gosala, Dheeraj B.↗

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

A Hybrid Reinforcement Learning-MPC Approach for Distribution System Critical Load Restoration

This paper proposes a hybrid control approach for distribution system critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while MPC models grid operations incorporating RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. We formulate the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The RL algorithm is trained offline using a historical forecast of renewable generation and load demand. The method is tested using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery. Case studies demonstrated that the proposed method outperforms other policies with static operating reserves.

distribution system↗

Hybrid Power Plant Bidding in Models of Future Electricity Systems

This paper proposes a stochastic model for hybrid power plants participation in day-ahead electricity markets, considering uncertainty in market prices and renewable generation. Additionally, it presents a methodology to incorporate this hybrid participation into existing production cost models (PCM), allowing the analysis and market design of future systems with high penetration of hybrids. These developments are illustrated using a wind-battery hybrid located in New York Independent System Operator (NYISO) footprint.

Kemp, Julie Mulvaney↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Nanoscale Confinement of Photo-Injected Electrons at Hybrid Interfaces

A prerequisite for advancing hybrid solar light harvesting systems is a comprehensive understanding of the spatiotemporal dynamics of photoinduced interfacial charge separation. Here, we demonstrate access to this transient charge redistribution for a model hybrid system of nanoporous zinc oxide (ZnO) and ruthenium bipyridyl chromophores. The site-selective probing of the molecular electron donor and semiconductor acceptor by time-resolved X-ray photoemission provides direct insight into the depth distribution of the photoinjected electrons and their interaction with the local band structure on a nanometer length scale. Our results show that these electrons remain localized within less than 6 nm from the interface, due to enhanced downward band bending by the photoinjected charge carriers. This spatial confinement suggests that light-induced charge generation and transport in nanoscale ZnO photocatalytic devices proceeds predominantly within the defect-rich surface region, which may lead to enhanced surface recombination and explain their lower performance compared to titanium dioxide (TiO 2 )-based systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Manufacturing Demonstration Facility: Development and Evaluation of Hybrid Manufacturing Toolpaths

The integration of additive manufacturing (AM) capabilities on Computer Numerical Control (CNC) systems allows for the expansion of additive manufacturing to a wide range of part and tool repair operations. This multi-tasking integration, termed hybrid manufacturing, has been researched by others in the past, and Autodesk has been critical in developing process planning and toolpath algorithms for hybrid systems. Objectives and Tasks: Hybrid manufacturing systems enable both additive and subtractive capabilities in a single manufacturing workcell. These systems have the potential to impact a variety of industries, including the tool and die industry due to their repair, refurbishment, and complex geometry manufacturing capabilities. While there has been significant development of toolpath planning for both subtractive and additive processes independently, there has been little, if any, development of hybrid toolpath planning to integrate both processes during the manufacturing design and toolpath generation stage of a product’s lifecycle. Furthermore, additive toolpath planning has been limited to planar manufacturing, but this limitation could be overcome as hybrid CNC machines have multi-axis control. The objectives of this research include: - Development and demonstration of independent three-, four-, and five-axis toolpath generation algorithms for both additive and subtractive processes, and - Development, demonstration, and integration of three-, four-, and five-axis hybrid process planning and toolpath generation algorithms for hybrid additive and subtractive processes. The team will leverage the widely used Autodesk Fusion 360 product design and manufacturing (CAD/CAM) platform to achieve these objectives. Autodesk will provide the expertise in CAD tools, as well as access to their new CAD/CAM manufacturing tools (3-, 4-, and 5-axis milling, additive toolpath generation). ORNL will provide expertise in additive manufacturing toolpath generation, process planning, and manufacturing validation. By the end of the program, the team will have developed and validated multi-axis milling, additive manufacturing, and hybrid manufacturing on an industrial hybrid CNC system (Mazak 500-VC).

42 ENGINEERING↗

Dual role of Fam208a during zygotic cleavage and early embryonic development

Maintenance of genome stability is essential for every living cell as genetic information is repeatedly challenged during DNA replication in each cell division event. Errors, defects, delays, and mistakes that arise during mitosis or meiosis lead to an activation of DNA repair processes and in case of their failure, programmed cell death, i.e. apoptosis, could be initiated. Fam208a is a protein whose importance in heterochromatin maintenance has been described recently. In this work, we describe the crucial role of Fam208a in sustaining genome stability during cellular division. }The targeted depletion of Fam208a in mice using CRISPR/Cas9 led to embryonic lethality before E12.5. We also used the siRNA approach to downregulate Fam208a in zygotes to avoid the influence of maternal RNA in the early stages of development. This early downregulation increased arresting of the embryonal development at the two-cell stage and the occurrence of multipolar spindles formation. To investigate this further, we used the yeast two-hybrid (Y2H) system and identified new putative interaction partners Gpsm2, Svil, and Itgb3bp. Their co-expression with Fam208a was assessed by RT-qPCR profiling and in situ hybridization [1] in multiple murine tissues. Based on these results we proposed that Fam208a functions within the HUSH complex by interaction with Mphosph8 as these proteins are not only able to physically interact but also co-localise. We are bringing new evidence that Fam208a is a multi-interacting protein affecting genome stability on the cell division level at the earliest stages of development and by interaction with methylation complex in adult tissues. }In addition to its epigenetic functions, Fam208a appears to have an important role in the zygotic division, possibly via interaction with newly identified putative partners Gpsm2, Svil, and Itgb3bp.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗

White Box Access to Quantum Testbeds for Co-Design

At Lawrence Livermore National Laboratory (LLNL), we operate and maintain the Quantum Device and Integration Testbed (QuDIT) facility, a small quantum testbed that supports about 10 active research teams (including our own) and over 50 internal and external collaborators. This testbed is designed to give remote white box access to users for research, training, and outreach. A guiding principle behind the development of our testbed infrastructure, software and user interfaces is to empower users to perform experiments at the cutting edge of quantum information science at any level of abstraction, from materials studies, device physics and control and characterization techniques to algorithm development and quantum operating system design. Our testbed targets a multilevel quantum system (qudit) to expand the accessible Hilbert space of a simple-to-manufacture quantum device and focuses on quantum simulation, typically implemented through custom gates designed with quantum optimal control methods, rather than on a universal computing framework with a fixed gate set. We leverage the Lab’s high-performance computing (HPC) program and related expertise to simulate quantum systems, develop hybrid algorithms, and generate gates optimized for given simulations. Additionally, we have adopted a co-design philosophy from the HPC community in designing new hardware, so that the systems we develop are optimized for the specific physics simulations we plan to use them for.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planning for the storm: Considering renewable energy for critical infrastructure resilience

This study uses the renewable energy optimization model to assess three critical facilities in North Carolina. Techno-economic results were then compared to analyses completed for critical facilities in California and New York to assess energy system cost effectiveness. Though solar photovoltaic (PV) arrays are cost-effective across each of the three North Carolina facilities, adopting battery storage to enable PV to operate with existing diesel generators in a hybrid energy system reduces the economic value of the system. This is in contrast to more economically viable systems in California and New York. All of these systems also offer unquantified resilience benefits by extending operation from hours to weeks across the facilities. If decision makers were able to value the resilience benefits offered by each system or utility rate structures were changed to incentivize battery storage during normal operations, it would impact these assessments. Even so, this analysis provides decision makers a key set of cost benchmarks when considering how they might improve resilience at their critical operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

Recent advances in hybrid metal oxide–zeolite catalysts for low-temperature selective catalytic reduction of NOx by ammonia

A hybrid catalytic system comprised of metal oxide and Cu or Fe exchanged zeolite components represents a potential advancement of state-of-the-art for selective catalytic reduction (SCR) of NOx by ammonia, including an elegant solution to the current challenge of improving the low-temperature efficiency of SCR catalysts. The idea is to enable in-situ NO oxidation over metal oxide component and concomitant fast SCR over zeolite component in the so-called “bifunctional mechanism”. This review is presented in the wake of growing interest in this innovative catalytic system. We begin this review by presenting key parameters that contribute to the synergy between metal oxide and zeolite components. Then, we discuss the materials selection for both components and their possible interactions in the system, followed by a summary of recent NH3-SCR investigations over multiple metal oxide–zeolite pairs and additional discussion on pairing techniques potentially explorable in upcoming studies. Finally, we end the review by providing the perspectives on future challenges in the development of this catalytic system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of QD photosensitizers in the photocatalytic production of hydrogen with biomimetic [FeFe]-hydrogenase. Comparative performance of CdSe and CdTe

Photocatalytic systems comprising a hydrogenase-type catalyst and CdX (X = S, Se, Te) chalcogenide quantum dot (QD) photosensitizers show extraordinary hydrogen production rates under visible light excitation. What remains unknown is the mechanism of energy conversion in these systems. In this work, we have explored this question by comparing the performance of two QD sensitizers, CdSe and CdTe, in photocatalytic systems featuring aqueous suspensions of a [Fe 2 (μ-1,2-benzenedithiolate) CO 6 ] catalyst and an ascorbic acid sacrificial agent. Overall, the hydrogen production yield for CdSe-sensitized reactions QDs was found to be 13 times greater than that of CdTe counterparts. According to emission quenching experiments, an enhanced performance of CdSe sensitizers reflected a greater rate of electron transfer from the ascorbic acid (k Asc ). The observed difference in the QD-ascorbic acid charge transfer rates between the two QD materials was consistent with respective driving forces for these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗