Lunar Orbiter photographic data analysis for Apollo landing hazard appraisal
Lunar orbiter photographic data analysis for Apollo landing hazard appraisal
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lunar orbiter photographic data analysis for Apollo landing hazard appraisal
Since hydrogen vehicles can be implemented in heavy-duty transportation applications such as buses, it is important to understand safety hazards and risks of hydrogen fuel cell electric bus (FCEB) and refueling technology. We conducted a hazard and operability analysis for FCEB operation/driving, refueling, and maintenance/inspection. We identified failure modes and consequences and defined a qualitative risk metric as the product of the likelihood of a failure and the severity of the worst-ca
Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.
The potential effects of carbon fibers on consumer products such as dishwashers, microwave ovens, and smoke detectors were investigated. The investigation was divided into two categories to determine the potential faults and hazards that could occur if fibers should enter the electrical circuits of the selected appliances. The categories were a fault analysis and a hazard analysis. Hazards considered were fire, flood, physical harm, explosion, and electrical shock. Electrical shock was found to be a possible occurrence related to carbon fibers. Faults were considered to be any effect on the performance of an appliance which would result in complaint or require service action.
LLNL experienced 26 occurrences related to the control of hazardous energy from January 1, 2008 through August 2010. These occurrences were 17% of the total number of reported occurrences during this 32-month period. The Performance Analysis and Reporting Section of the Contractor Assurance Office (CAO) routinely analyzes reported occurrences and issues looking for patterns that may indicate changes in LLNL’s performance and early indications of performance trends. It became apparent through these analyses that LLNL might have experienced a change in the control of hazardous energy and that these occurrences should be analyzed in more detail to determine if the perceived change in performance was real, whether that change is significant and if the causes of the occurrences are similar. This report documents the results of this more detailed analysis.
This report documents the methodology and results for calculating the effective dose equivalent (EDE) to the maximally exposed individual (MEI) from atmospheric radionuclide emissions from Idaho National Laboratory (INL) sources in Calendar Year (CY) 2024. The calculations were performed in accordance with requirements in Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). UDFs were calculated using the computer model CAP88-PC for unit (1 Ci/yr) emission rates at INL Site facilities and INL in-town (Idaho Falls) facilities and stored in Microsoft Access databases. The UDFs—in this case, mrem/Ci—were then combined with radionuclide-specific release (emission) rates for each facility-specific source to compute doses at predetermined public receptor locations, including the MEI locations. This report contains the dose results and a description of the methodology and tools used to compute the doses.
Aerial wildfire operations are high risk and account for a large number of firefighter deaths. Increasing intensity of wildfires is driving a surge in aerial operations, while simultaneously there is growing interest in improving system safety and performance. In this work, wildfire aviation mishaps documented using the SAFECOM system are analyzed using a previously developed framework for hazard extraction and analysis of trends (HEAT). Hazards and specific failure modes are extracted from the narrative data in SAFECOM forms using natural language processing techniques. Metrics for each hazard are calculated, including frequency, rate, and severity. We examine whether these metrics change over time, and whether they are related to metadata, such as region and aircraft type. The results of the hazard analysis are presented in a risk matrix, identifying the highest and lowest risk hazards based on rate of occurrence and average severity. Results identify jumper operations hazards as high-risk, in addition to bucket drop failures, cargo let down failures, and severe weather as medium risk.
Aerial wildfire operations are high risk and account for a large number of firefighter deaths. Increasing intensity of wildfires is driving a surge in aerial operations, while simultaneously there is growing interest in improving system safety and performance. In this work, wildfire aviation mishaps documented using the SAFECOM system are analyzed using a previously developed framework for hazard extraction and analysis of trends (HEAT). Hazards and specific failure modes are extracted from the narrative data in SAFECOM forms using natural language processing techniques. Metrics for each hazard are calculated, including frequency, rate, and severity. We examine whether these metrics change over time, and whether they are related to metadata, such as region and aircraft type. The results of the hazard analysis are presented in a risk matrix, identifying the highest and lowest risk hazards based on rate of occurrence and average severity. Results identify jumper operations hazards as high-risk, in addition to bucket drop failures, cargo let down failures, and severe weather as medium risk.
This report details calculations of potential dose at public receptor locations surrounding the Idaho National Laboratory (INL) Site boundary, and INL in-town facilities, from radionuclides reported to be in use and potentially emitted from INL facilities during calendar year (CY) 2021. All calculations were performed in accordance with the requirements in Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). Modeling methodology, model input parameters, and contribution to dose by facility, source, and radionuclide at the maximally exposed individual (MEI) location are also discussed. The information in this report supports the “National Emission Standards for Hazardous Air Pollutants - Calendar Year 2021 INL Report for Radionuclides” (INL 2022). In CY 2021, the estimated annual potential dose at the INL Site MEI location was 6.67E-02 mrem/yr, up slightly from the previous year, but far less than the regulatory standard of 10 mrem/yr (CFR 40 Part 61, Subpart H). Approximately 97% of the total dose to the INL Site MEI originated from MFC sources. Emissions from INL in-town facilities resulted in an estimated annual potential dose of 6.21E-03 mrem/yr to the MEI, down 40% from the CY 2020 estimated dose. Year-to-year variations in estimated annual dose can be attributed to adjustments in laboratory operations, changes to facility infrastructure, and variation in meteorological conditions.
This report details calculations of potential dose at public receptor locations surrounding the Idaho National Laboratory (INL) Site boundary, and INL in-town facilities, from radionuclides reported to be in use and potentially emitted from INL facilities during calendar year (CY) 2022. All calculations were performed in accordance with the requirements in Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). Modeling methodology, model input parameters, and contribution to dose by facility, source, and radionuclide at the maximally exposed individual (MEI) location are also discussed. The information in this report supports the “National Emission Standards for Hazardous Air Pollutants – Calendar Year 2022 INL Report for Radionuclides” (DOE-ID 2023). In CY 2022, the estimated annual potential dose at the INL Site MEI location was 1.78E-02 mrem/yr, down from the previous year, and far less than the regulatory standard of 10 mrem/yr (CFR 40 Part 61, Subpart H). Approximately 87% of the total dose to the INL Site MEI originated from Materials and Fuels Complex sources. Emissions from INL in-town facilities resulted in an estimated annual potential dose of 4.03E-03 mrem/yr to the MEI, down 35% from the CY 2021 estimated dose. Year-to-year variations in estimated annual dose can be attributed to adjustments in laboratory operations, changes to facility infrastructure, and variation in meteorological conditions.
This report details calculations of potential dose—at public receptor locations surrounding the Idaho National Laboratory (INL) Site boundary and INL in-town facilities—from radionuclides reported to be in use and potentially emitted from INL facilities during calendar year (CY) 2025. All calculations were performed in accordance with the requirements of Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). Modeling methodology, model-input parameters, and contribution to dose by facility, source, and radionuclide at the maximally exposed individual (MEI) location are also discussed. The information in this report supports the “National Emission Standards for Hazardous Air Pollutants—Calendar Year 2025 INL Report for Radionuclides” (DOE-ID 2026). During CY 2025, the estimated annual potential dose at the INL Site MEI location was 2.45E-02 mrem/yr, up from the previous year, but remaining far less than the regulatory standard of 10 mrem/yr (CFR 40 Part 61, Subpart H). Approximately 92% of the total dose to the INL Site MEI originated from Materials and Fuels Complex sources. Emissions from INL in-town facilities resulted in an estimated annual potential dose of 4.50E-03 mrem/yr to the MEI, down slightly from the CY 2024 estimated dose. Year-to-year variations in estimated annual dose can be attributed to adjustments in laboratory operations, changes to facility infrastructure, and variation in meteorological conditions.
Digital computer technique for analysis of radiological hazards of nuclear rocket flight operations
No abstract available
Purpose: The purpose of this article is to report the results of a prospective single-center study analyzing the long-term clinical and angiographic outcomes of subintimal angioplasty (SIA) for the treatment of chronic total occlusions (CTOs) of the femoropopliteal artery. Materials and Methods: Patients with severe intermittent claudication or critical limb ischemia (CLI) were enrolled in the study. All lesions were treated with SIA and provisional stenting. Primary end points were technical success, patient survival, limb salvage, lesion primary patency, angiographic binary restenosis (>50%), and target lesion revascularization (TLR). Regular clinical and angiographic follow-up was set at 6 and 12 months and yearly thereafter. Study end points were calculated with life-table survival analysis. Proportional-hazards regression analysis with a Cox-model was applied to adjust for confounding factors of heterogeneity. Results: Between May 2004 and July 2009, 98 patients (105 limbs, patient age 69.3 {+-} 9.9 years) were included in the study. Technical success rate was 91.4% with a lesion length of 121 {+-} 77 mm. Limb-salvage and survival rates were 88.7% and 84.1% at 3 years, respectively. After 12, 24, and 36 months, primary patency was 80.1%, 42.3%, and 29.0%, angiographic binary restenosis was 37.2%, 68.6%, and 80.0%, and TLR was 84.8%, 73.0%, and 64.5%, respectively. CLI was the only adverse predictor for decreased primary patency (hazard ratio [HR] 0.36; 95% confidence interval [CI] 0.16-0.80, p = 0.012), whereas significantly less restenosis was detected after spot stenting of the entry and/or re-entry site (HR 0.31; 95% CI 0.10-0.89, p = 0.01 and HR 0.20; 95% CI 0.07-0.56, p = 0.002, respectively). Conclusions: Subintimal angioplasty is a safe and effective revascularization technique for the treatment of CTOs of the femoropopliteal artery. Provisional stenting may have a role at the subintimal entry or true lumen re-entry site.
Not Available
LANL has been contacted to provide possible assistance in safe disposition of a number of 241 Am-bearing materials associated with local industrial operations. Among the materials are ion exchange resins which have been in contact with 241 Am and nitric acid, and which might have potential for exothermic reaction. The purpose of this paper is to analyze and define the resin forms and quantities to the extent possible from available data to allow better bounding of the potential reactivity hazard of the resin materials. An additional purpose is to recommend handling procedures to minimize the probability of an uncontrolled exothermic reaction.
Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a high temperature steam electrolysis hydrogen production facility (HTEF) in close proximity to an NPP. This analysis evaluates a postulated HTEF located 1 km from an NPP, including the likelihood of an accident and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure at a distance of 1 km. Furthermore, the minimum separation distance of the HTEF is calculated based on the target fragility criteria of 1 psi defined in Regulatory Guide 1.91.
Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a high temperature steam electrolysis hydrogen production facility (HTEF) in close proximity to an NPP. This analysis evaluates a postulated HTEF located 1 km from an NPP, including the likelihood of an accident and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure at a distance of 1 km. Furthermore, the minimum separation distance of the HTEF is calculated based on the target fragility criteria of 1 psi defined in Regulatory Guide 1.91.