Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Powder Metallurgy – Hot Isostatic Pressing of 316H Stainless Steel for Nuclear Components

Overview of the PM-HIP work performed on stainless steel 316H as part of the microreactor program. High temperature mechanical testing was performed, with concerns identified with the creep-fatigue performance. Variations in feedstock and processing parameters did not conclusively identify the primary factor in the reduced creep-fatigue performance.

36 - MATERIALS SCIENCE↗

Acetabular Cup with a Trabecular Coating: A Novel Approach to a Monolithic Cup Made of One High-Strength Ceramic Material

An advanced monolithic cup comprising a thin liner and a trabecular coating is a promising alternative to the current modular ceramic cups for hip replacements because it can be anchored directly to the human bone and features larger femoral heads allowing a greater range of motion. In this study, the authors propose a fabrication route for an advanced monolithic cup of only one high-strength ceramic material by joining a partially sintered liner and a coating with a ceramic paste as an intermediate layer and subsequent sintering. Therefore, the challenge here is to avoid the formation of defects at the coating/intermediate layer interfaces during classical sintering which is due to compressive tension constrained coating sintering in the initial sintering stages. In this study, the defect formation is minimized by sintering at constant low shrinkage rates, as this results in favorable compressive stresses in the coating in the initial sintering stages and a decrease in the differences in the densification rates. For the first time, by using the proposed route, the authors prepare an advanced monolithic cup of only alumina-toughened zirconia (ATZ) that contains a coating with a porosity of 50 vol% and interconnected pores between 150 and 450 μm, as required for bone-ingrowth.

36 MATERIALS SCIENCE↗

Early experiences evaluating the HPE/Cray ecosystem for AMD GPUs

Summary The Oak Ridge Leadership Computing Facility (OLCF) has a long history of supporting and promoting GPU‐accelerated computing starting with the deployment of the Titan supercomputer in 2021 and continuing with the Summit supercomputer which has a theoretical peak performance of approximately 200 petaflops. Because the majority of Summit's computational power comes from its 27,972 GPUs, users must port their applications to one of the supported programming models in order to make efficient use of the system. To prepare the transition to Frontier, the OLCF's exascale supercomputer, users will need to adapt to an entirely new ecosystem which will include new hardware and software technologies. First, users will need to familiarize themselves with the AMD Radeon GPU architecture. Furthermore, users who have been previously relying on CUDA will need to transition to the Heterogeneous‐Computing Interface for Portability (HIP) or one of the other supported programming models (e.g., OpenMP, OpenACC). In this work, we describe our initial experiences and lessons learned in porting three applications or proxy apps currently running on Summit to the HPE/Cray ecosystem to leverage the compute power from AMD GPUs: minisweep, GenASiS, and Sparkler. Each one is representative of current production workloads utilized at the OLCF, different programming languages, and different programming models.

Melesse Vergara, Verónica G.↗

Development and cross‐validation of a circumference‐based predictive equation to estimate body fat in an active population

Abstract Objective The U.S. Army uses sex‐specific circumference‐based prediction equations to estimate percent body fat (%BF) to evaluate adherence to body composition standards. The equations are periodically evaluated to ensure that they continue to accurately assess %BF in a diverse population. The objective of this study was to develop and validate alternative field expedient equations that may improve upon the current Army Regulation (AR) body fat (%BF) equations. Methods Body size and composition were evaluated in a representatively sampled cohort of 1904 active‐duty Soldiers (1261 Males, 643 Females), using dual‐energy X‐ray absorptiometry (%BF DXA ), and circumferences obtained with 3D imaging and manual measurements. Sex stratified linear prediction equations for %BF were constructed using internal cross validation with %BF DXA as the criterion measure. Prediction equations were evaluated for accuracy and precision using root mean squared error, bias, and intraclass correlations. Equations were externally validated in a convenient sample of 1073 Soldiers. Results Three new equations were developed using one to three circumference sites. The predictive values of waist, abdomen, hip circumference, weight and height were evaluated. Changing from a 3‐site model to a 1‐site model had minimal impact on measurements of model accuracy and performance. Male‐specific equations demonstrated larger gains in accuracy, whereas female‐specific equations resulted in minor improvements in accuracy compared to existing AR equations. Equations performed similarly in the second external validation cohort. Conclusions The equations developed improved upon the current AR equation while demonstrating robust and consistent results within an external population. The 1‐site waist circumference‐based equation utilized the abdominal measurement, which aligns with associated obesity related health outcomes. This could be used to identify individuals at risk for negative health outcomes for earlier intervention.

Taylor, Kathryn M.↗

Taxogenomic Analysis of a Novel Yeast Species, Lachancea rosae Sp. Nov. F.A., Isolated From the Wild Rose Rosa californica

A novel Saccharomycotina yeast strain, yHQL494, was isolated from the rose hip of the wild rose Rosa californica from Castle Crags State Park, California, USA. Phylogenetic analyses of both whole genome data and the sequences from the D1/D2 region of the large ribosomal subunit (LSU) rRNA gene placed strain yHQL494 within the genus Lachancea and grouped it into a clade with Lachancea lanzarotensis and Lachancea meyersii. Taxogenomic analyses were conducted on publicly available genome sequences to gain a deeper insight into the carbon and nitrogen gene-trait associations across the Lachancea clade. The results of these analyses were found to be consistent across Lachancea species. Growth assays and microscopic analyses were conducted to determine the physiological characteristics of strain yHQL494, including the presence of hyphae or pseudohyphae, ascospore formation, fermentation abilities, and assimilation of carbon and nitrogen compounds. Based on the phenotypic and genomic characteristics of the strain yHQL494 T (=NRRL Y-64858 T , =CBS 18,574 T ), we propose a new species, Lachancea rosae sp. nov. f.a.

Bajgain, Yakendra [Villanova Univ., PA (United Sta↗

The Kokkos OpenMPTarget Backend: Implementation and Lessons Learned

As the supercomputing landscape diversifies, solutions such as Kokkos to write vendor agnostic applications and libraries have risen in popularity. Kokkos provides a programming model designed for performance portability, which allows developers to write a single source implementation that can run efficiently on various architectures. At its heart, Kokkos maps parallel algorithms to architecture and vendor specific backends written in lower level programming models such as CUDA and HIP. Another approach to writing vendor agnostic parallel code is using OpenMP’s directives based approach, which lets developers annotate code to express parallelism. It is implemented at the compiler level and is supported by all major high performance computing vendors, as well as the primary Open Source toolchains GNU and LLVM. Since its inception, Kokkos has used OpenMP to parallelize on CPU architectures. In this paper, we explore leveraging OpenMP for a GPU backend and discuss the challenges we encountered when mapping the Kokkos APIs and semantics to OpenMP target constructs. As an exemplar workload we chose a simple conjugate gradient solver for sparse matrices. We find that performance on NVIDIA and AMD GPUs varies widely based on details of the implementation strategy and the chosen compiler. Furthermore, the performance of the OpenMP implementations decreases with increasing complexity of the investigated algorithms.

Gayatri, Rahulkumar↗

Making Uintah Performance Portable for Department of Energy Exascale Testbeds

To help ease ports to forthcoming Department of Energy (DOE) exascale systems, testbeds have been made available to select users. These testbeds are helpful for preparing codes to run on the same hardware and similar software as in their respective exascale systems. This paper describes how the Uintah Computational Framework, an open-source asynchronous many-task (AMT) runtime system, has been modified to be performance portable across the DOE Crusher, DOE Polaris, and DOE Sunspot testbeds in preparation for portable simulations across the exascale DOE Frontier and DOE Aurora systems. The Crusher, Polaris, and Sunspot testbeds feature the AMD MI250X, NVIDIA A100, and Intel PVC GPUs, respectively. This performance portability has been made possible by extending Uintah’s intermediate portability layer [18] to additionally support the Kokkos::HIP, Kokkos::OpenMPTarget, and Kokkos::SYCL back-ends. This paper also describes notable updates to Uintah’s support for Kokkos, which were required to make this extension possible. Results are shown for a challenging radiative heat transfer calculation, central to the University of Utah’s predictive boiler simulations. These results demonstrate single-source portability across AMD-, NVIDIA-, and Intel-based GPUs using various Kokkos back-ends.

Holmen, John↗

IRIS Reimagined: Advancements in Intelligent Runtime System for Task-Based Programming

Task-based programming models are gaining traction in scientific computing. IRIS is a portable runtime system that exploits multiple heterogeneous programming systems and can discover available resources and manage multiple diverse programming systems (e.g., CUDA, Hexagon, HIP, Level Zero, OpenCL, and OpenMP) simultaneously. It accounts for the constraints of task dependencies and provides customizable scheduling policies to map those tasks to heterogeneous devices. In this paper, we present new capabilities added to IRIS to improve its portability for heterogeneous programming, build-friendliness, and performance efficiency. The new additions include vendor-specific kernel support, a runtime system with a foreign function interface to eliminate writing wrapper or boilerplate code for heterogeneous kernels, an easy-to-use and configurable CMake-based build environment, automatic and efficient data transfers and orchestration, and the Hunter and DAGGER toolchains to evaluate IRIS’s task scheduling algorithms.

Miniskar, Narasinga Rao↗

Orthopedic metallic hardware in routine abdomino-pelvic CT scans: occurrence and clinical significance

Purpose: To study the occurrence of orthopedic metallic hardware in routine abdomen/pelvic computed tomography (CT) scans and their impact on image quality (IQ) and diagnostic evaluation. Material and methods: In this retrospective single institution study, we analyzed 3500 consecutive abdomen/pelvis CT scans for occurrence of orthopedic metallic hardware. In the cohort of patients with metallic hardware detected on CT scans, subjective and objective IQ analysis was performed to estimate diagnostic acceptability (DA, 4-point scale), subjective noise (SN, 3-point scale), presence of artifacts (PA, 4-point scale) and objective noise. The clinical significance of metallic hardware was determined by evaluating the impact of artifacts on radiological diagnosis according to the clinical indication and disease type. Results: Orthopedic metallic hardware was encountered in 4.97% of abdomino-pelvic CT scans (n = 174/3500), and artifacts related to the hardware in the region of clinical interest were identified in 82% (n = 144/174) of scans. The overall mean DA was 2.66 (n = 174), and it was severely limited (score < 2) in 32% of cases particularly affecting patients with bilateral hip implants (92.6%, n = 25/27). The artifacts due to hardware significantly limited diagnostic evaluation in 58.6% of cases (PA score ≥ 3), and the image noise was unacceptable in 71% of cases (SN score > 2) in the region of clinical interest. Conclusion: Orthopedic metallic hardware is encountered in nearly 5% of abdomino-pelvic CT scans and causes significant image degradation limiting diagnostic evaluation in the region of clinical interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Piriformis Syndrome: Long-Term Follow-up in Patients Treated with Percutaneous Injection of Anesthetic and Corticosteroid Under CT Guidance

Purpose: This study was designed to evaluate the efficacy of CT-guided injection of anesthetic and corticosteroid for the treatment of pain in patients with piriformis syndrome unresponsive to conservative treatment. Methods: We enrolled 23 patients with piriformis syndrome, proposing a percutaneous intramuscular injection of methylprednisone-lidocaine. Among them, 13 patients accepted and 10 refused to undergo the procedure; the second group was used as a control group. Clinical evaluation was performed with four maneuvers (Lasegue sign, FAIR test, Beatty and Freiberg maneuver) and a VAS questionnaire before the injection, after 5-7 days, and after 2 months. A telephonic follow-up was conducted to 3, 6, and 12 months. Results: Procedural success was achieved in all patients who were treated without any complications. After 2 months, among 13 treated subjects, 2 of 13 patients showed positivity to FAIR test (hip flexion, adduction, and internal rotation), 2 of 13 were positive to Lasegue sign, and the Beatty maneuver was positive in 1 patient. Patients who underwent conservative treatment were positive respectively in 7 of 10 (p = 0.01), 6 of 10 (p = 0.03), and 6 of 10 (p = 0.01). The VAS score showed a difference between patients treated with percutaneous approach and those managed with conservative therapy at the baseline evaluation (p = 0.04), after 2 months (p = 0.02), and 12 months (p = 0.002). We observed a significant reduction in pain for patients treated percutaneously, who were evaluated with the VAS scale at 5-7 days, 2 months, 3, 6, and 12 months (p < 0.001). Conclusions: Our findings suggested potential benefit from the percutaneous injection of anesthetics and corticosteroids under CT guidance for the treatment of piriformis syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blood Pressure Changes After Exposures Increasing Angiotensin-Converting Enzyme Activity and After Its Normalization with Dihydroquercetin in Male Wistar Rats

Changes in BP and HR were assessed after exposures increasing activity of angiotensin-converting enzyme: ionizing radiation, NO synthase inhibitor (L-NAME), and dexamethasone. Effects of dihydroquercetin and angiotensin-converting enzyme inhibitor enalapril on activity of this enzyme, BP, and HR were also evaluated under these exposures. Wistar male rats were subjected to X-ray irradiation in a dose of 2.5 Gy. Angiotensin-converting enzyme activity in the aorta sections was determined by Hip-His-Leu hydrolysis. BP and HR were recorded using a non-invasive tail-cuff method and PowerLab 8/35 software. BP and HR were not altered with the increase in activity of angiotensin-converting enzyme after irradiation. In case of prolonged (7 days) treatment with NO synthase inhibitor and dexamethasone, the increase in enzyme activity was accompanied by elevation of BP and, in the case of NO synthase inhibitor, HR reduction. Dihydroquercetin normalized the enzyme activity and lowered BP, but not to the normal level. Enalapril normalized BP, increased by NO synthase inhibitor solution intake; at the same time, the angiotensinconverting enzyme activity decreased more than 2-fold in comparison with the normal.

60 APPLIED LIFE SCIENCES↗

Residual Stress Measurements in Extreme Environments for Hazardous, Layered Specimens

In nuclear fuel plates of low-enriched U-10Mo (LEU) clad with aluminum by hot isostatic pressing (HIP), post-irradiation stresses arising during reactor shutdown are a major concern for safe reactor operations. Measurement of those residual stresses has not previously been possible because the high radioactivity of the plates requires handling only by remote manipulation in a hot cell. The incremental slitting method for measuring through-thickness stress profiles was modified, and a system for automated, remote operation was built and tested. Experimental modifications consisted of replacing electric-discharge machining (EDM) with a small end mill and strain-gauge measurements with cantilever displacement measurements. The inverse method used to calculate stresses was the pulse-regularization method modified to allow discontinuities across material interfaces. The new system was validated by comparing with conventional slitting on a depleted U-10Mo (DU) fuel plate. The new system was applied to two measurements each on six as-fabricated (pre-irradiation) LEU miniature fuel plates. Variations between the measurements at two locations in the same plate were strongly correlated with measured geometrical heterogeneity in the plate—a tilt in the fuel foil. Compressive stresses in the U-10Mo were shown to increase from 20 to 250 MPa as the ratio of aluminum thickness to U-10Mo thickness increased causing increased constraint during cooling. Faster cooling rates during processing also increased stress magnitudes. The measurements trends agreed with data in the literature from similar plates made with DU, which further validates the method. Because other methods are impractical in a hot cell, the modified slitting method is now poised for the first measurements of post-irradiation stresses.

36 MATERIALS SCIENCE↗

Microstructure and Strengthening Mechanisms in an Ultrafine Grained Al-Mg-Sc Alloy Produced by Powder Metallurgy

Additions of Sc to an Al-Mg matrix were investigated, paying particular attention to the influence of Al3Sc precipitates and other dispersoids, as well as grain size, on mechanical behavior. Prior studies have shown that Sc significantly increases the strength of coarse-grained Al-Mg alloys. Prompted by these findings, we hypothesized that it would be of fundamental and technological interest to study the behavior of Sc additions to an ultrafine-grained (UFG) microstructure (e.g., 100’s nm). Accordingly, we investigated the microstructural evolution and mechanical behavior of a cryomilled ultrafine grained Al-5Mg-0.4Sc (wt pct) and compared the results to those of an equivalent fine-grained material (FG) produced by powder metallurgy. Experimental materials were consolidated by hot isostatic pressing (HIP’ing) followed by extrusion or dual mode dynamic forging. Under identical processing conditions, UFG materials generate large Al3Sc precipitates with an average diameter of 154 nm and spaced approximately 1 to 3 µm apart, while precipitates in the FG materials have a diameter of 24 nm and are spaced 50 to 200 nm apart. The strengthening mechanisms are calculated for all materials and it is determined that the greatest strengthening contributions for the UFG and FG materials are Mg-O/N dispersion strengthening and precipitate strengthening, respectively.

36 MATERIALS SCIENCE↗

Correlation of Microstructure to Creep Response of Hot Isostatically Pressed and Aged Electron Beam Melted Inconel 718

In this paper, creep rupture samples were fabricated by additive manufacturing (AM) via electron beam melting (EBM) to study the effects of grain morphology (equiaxed/columnar grains) and loading direction (longitudinal/transverse) with respect to build direction on creep deformation at 923 K (650 °C) with applied stresses of 580 and 600 MPa. The observed minimum creep rates and creep rupture lives of EBM Inconel 718 after post-processing by hot isostatic pressing (HIP) were found to be comparable to wrought material. The material with equiaxed grains exhibited low creep strain (2 pct) and short creep lifetimes (800 hours), whereas longer times (approximately 4500 hours) and high creep strain (up to 23 pct) were observed for material with columnar grains. The high stress exponent (n > 14) reflected the resistance to dislocation motion by γ” particles during creep. A precipitate-free zone (PFZ) was observed around the grain boundary δ phase. Creep damage occurred as voids and cracks in the PFZ. Finally, optimal post-processing of EBM Inconel 718 material should be explored to prevent δ phase embrittlement.

36 MATERIALS SCIENCE↗

Electrochemical Behavior of Biomedical Titanium Alloys Coated with Diamond Carbon in Hanks’ Solution

Biomedical implants in the knee and hip are frequent failures because of corrosion and stress on the joints. To solve this important problem, metal implants can be coated with diamond carbon, and this coating plays a critical role in providing an increased resistance to implants toward corrosion. In this study, we have employed diamond carbon coating over Ti-6Al-4V and Ti-13Nb-13Zr alloys using hot filament chemical vapor deposition method which is well-established coating process that significantly improves the resistance toward corrosion, wears and hardness. The diamond carbon-coated Ti-13Nb-13Zr alloy showed an increased microhardness in the range of 850 HV. Electrochemical impedance spectroscopy and polarization studies in SBF solution (simulated body fluid solution) were carried out to understand the in vitro behavior of uncoated as well as coated titanium alloys. The experimental results showed that the corrosion resistance of Ti-13Nb-13Zr alloy is relatively higher when compared with diamond carbon-coated Ti-6Al-4V alloys due to the presence of β phase in the Ti-13Nb-13Zr alloy. Electrochemical impedance results showed that the diamond carbon-coated alloys behave as an ideal capacitor in the body fluid solution. Moreover, the stability in mechanical properties during the corrosion process was maintained for diamond carbon-coated titanium alloys.

36 MATERIALS SCIENCE↗

Mechanical Alloying and Powder Forging of 18%Cr Oxide Dispersion-Strengthened Steel Produced Using Elemental Powders

Oxide dispersion-strengthened (ODS) ferritic steels are potential materials for cladding tubes in fast breeder fission reactors. These are mostly prepared by mechanical alloying of yttria powder with pre-alloyed powders. Using elemental powders offers flexibility in the choice of alloy compositions. Here we report mechanical alloying of Fe-18Cr-2W-0.2Ti-0.35Y{sub 2}O{sub 3} (compositions in wt.%) ODS steel using elemental powders of Fe, Cr, W and Ti with yttria powder. After 5 h of milling, no significant changes in particle size and crystallite size were observed. Powders milled for 5 and 7 h were consolidated through powder forging route. The optimum milling time for mechanical alloying could be determined only after evaluating the forgings. It is difficult to achieve recrystallization in ODS alloys. The forging process parameters were optimized to achieve a dense alloy with a fine recrystallized microstructure. Factors leading to recrystallization are discussed. It is shown that recrystallization in ODS steels is more likely to occur during forging as compared to extrusion/rolling. The powder forging route offers several advantages over the conventional extrusion or HIP routes.

36 MATERIALS SCIENCE↗

Build Orientation Effects on Texture and Mechanical Properties of Selective Laser Melting Inconel 718

The production of components via selective laser melting (SLM) metal additive manufacturing results in microstructures unique to the process that are highly dependent on laser processing parameters and orientation of part geometry relative to the build direction. This study investigates the variation in tensile properties of SLM Inconel 718 at varying angles with respect to build direction. ASTM E8 tensile specimens were built in XY, Z, and B+45 from Z orientations to near-net shape, HIP and heat treated, and tensile tested at room temperature. Orientation dependence of mechanical properties was observed; Z samples had the lowest strength and highest elongation, while XY samples had the highest strength and lowest elongation. Optical, SEM, and EBSD analysis were conducted to probe for microstructure variation that could be the cause of the difference in mechanical properties. Analysis of pole figures and grain maps suggests a preferred grain texture and twinning orientation that aligns with the build direction, which may contribute to the anisotropic enhancement in ductility.

36 MATERIALS SCIENCE↗