Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Giovanni”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Layered inorganic/organic mercaptopropyl pendant chain hybrid for chelating heavy cations

Graphical abstract: Crystalline lamellar silicate RUB-18 was immobilized with mercaptopropyl groups at the surface and then used as support for cadmium and lead removal from aqueous solutions. Highlights: Black-Right-Pointing-Pointer Synthetic methodology requires intercalation. Black-Right-Pointing-Pointer Organofunctionalized ilerite compound as sorbent. Black-Right-Pointing-Pointer Active mercaptopropyl groups remove cations. Black-Right-Pointing-Pointer High maximum sorption capacity for cadmium. -- Abstract: Heavy metal sorbents with uptake capacities for divalent cadmium and lead cation removal from aqueous solutions have been synthesized by grafting mercaptopropyltrimethoxysilane onto the surface of two different precursors obtained from lamellar ilerite, its acidic and the cetyltrimethylammonium exchanged forms. The organofunctionalization was carried out by two different procedures: reflux and solvent evaporation methodologies. Elemental analysis data based on carbon content gave 1.37 and 3.53 mmol of organic pendant groups per gram of hybrid by the reflux method, when starting from acidic ilerite and the surfactant form. X-ray diffraction corroborated the maintenance of the original crystallinity. Infrared spectroscopy and nuclear magnetic resonance for {sup 29}Si and {sup 13}C nuclei are in agreement with the success of the proposed method. The sulfur basic centers attached to the lamellar structure are used to coordinate both cations at the solid/liquid interface. The isotherms were obtained through the batchwise process and the experimental data were adjusted to the Freundlich model. The maximum sorption capacities of 5.55 and 5.12 mmol g{sup -1} for lead and 6.10 and 7.10 mmol g{sup -1} for cadmium were obtained for organofunctionalized ilerite and its surfactant form, synthesized by reflux methodology. This behavior suggested that these hybrids could be employed as promising sorbents with a polluted system.

36 MATERIALS SCIENCE↗

3D-Conformal Versus Intensity-Modulated Postoperative Radiotherapy of Vaginal Vault: A Dosimetric Comparison

We evaluated a step-and-shoot IMRT plan in the postoperative irradiation of the vaginal vault compared with equispaced beam arrangements (3-5) 3D-radiotherapy (RT) optimized plans. Twelve patients were included in this analysis. Four plans for each patient were compared in terms of dose-volume histograms, homogeneity index (HI), and conformity index (CI): (1) 3 equispaced beam arrangement 3D-RT; (2) 4 equispaced beam arrangement 3D-RT; (3) 5 equispaced beam arrangement 3D-RT; (4) step-and-shoot IMRT technique. CI showed a good discrimination between the four plans. The mean scores of CI were 0.58 (range: 0.38-0.67) for the 3F-CRT plan, 0.58 (range: 0.41-0.66) for 4F-CRT, 0.62 (range: 0.43-0.68) for 5F-CRT and 0.69 (range: 0.58-0.78) for the IMRT plan. A significant improvement of the conformity was reached by the IMRT plan (p < 0.001 for all comparisons). As expected, the increment of 3D-CRT fields was associated with an improvement of target dose conformity and homogeneity; on the contrary, in the IMRT plans, a better conformity was associated to a worse target dose homogeneity. A significant reduction in terms of D{sub mean}, V90%, V95%, V100% was recorded for rectal and bladder irradiation with the IMRT plan. Surprisingly, IMRT supplied a significant dose reduction also for rectum and bladder V30% and V50%. A significant dosimetric advantage of IMRT over 3D-RT in the adjuvant treatment of vaginal vault alone in terms of treatment conformity and rectum and bladder sparing is shown.

61 RADIATION PROTECTION AND DOSIMETRY↗

SORS: A New Software for the Simulation of Radiotherapy Schedule

We present a software for choosing the best radiotherapy treatment schedule for head and neck cancers as a beginning radiotherapy plan or a temporarily interrupted plan. Its application occurs according to two modalities: the first adopts the best estimates for model parameters; the second takes into account the parameters' uncertainty too. In both cases, the choice becomes the schedule with the highest uncomplicated tumor control probability (UTCP). In the UTCP valuation, the normal tissue complication probability (NTCP) of each organ is related to the gravity of its possible late injury. For NTCP calculation, it has been adopted the empirical LKB (Lyman-Kutcher-Burman) model corrected for dose/fraction via linear-quadratic model and the incomplete repair effect. The tumor control probability (TCP) model is Poisson based and contains corrections for dose/fraction and regrowth effect; optionally, it can be accounted for the incomplete repair effect as well. At the end of processing, a detailed file with all informations about UTCP, TCP and single organ NTCP is furnished for every examined schedule. Moreover, a useful 3-D graphic representation of the schedule's UTCP is available, allowing the physician to easily understand the schedules with the highest radiotherapeutic efficacy. The open source characteristic allows the program to adapt to the individual clinical case as well as to be a valid support in radiobiological research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative dosimetric and radiobiological assessment among a nonstandard RapidArc, standard RapidArc, classical intensity-modulated radiotherapy, and 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecologic cancer

To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose on PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d{sub 2cc}, d{sub 1cc}, and d{sub max} (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Manipulating the 3D organization of the largest synthetic yeast chromosome

Whether synthetic genomes can power life has attracted broad interest in the synthetic biology field. Here, we report de novo synthesis of the largest eukaryotic chromosome thus far, synIV, a 1,454,621-bp yeast chromosome resulting from extensive genome streamlining and modification. We developed megachunk assembly combined with a hierarchical integration strategy, which significantly increased the accuracy and flexibility of synthetic chromosome construction. Besides the drastic sequence changes, we further manipulated the 3D structure of synIV to explore spatial gene regulation. Surprisingly, we found few gene expression changes, suggesting that positioning inside the yeast nucleoplasm plays a minor role in gene regulation. Lastly, we tethered synIV to the inner nuclear membrane via its hundreds of loxPsym sites and observed transcriptional repression of the entire chromosome, demonstrating chromosome-wide transcription manipulation without changing the DNA sequences. Our manipulation of the spatial structure of synIV sheds light on higher-order architectural design of the synthetic genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of spatial confinement on magnetic hyperthermia via dipolar interactions in Fe3O4 nanoparticles for biomedical applications

In this work, the effect of nanoparticle confinement on the magnetic relaxation of iron oxide (Fe3O4) nanoparticles (NP) was investigated by measuring the hyperthermia heating behavior in high frequency alternating magnetic field. Three different Fe3O4 nanoparticle systems having distinct nanoparticle configurations were studied in terms of magnetic hyperthermia heating rate and DC magnetization. All magnetic nanoparticle (MNP) systems were constructed using equivalent ~10nm diameter NP that were structured differently in terms of configuration, physical confinement, and interparticle spacing. The spatial confinement was achieved by embedding the Fe3O4 nanoparticles in the matrices of the polystyrene spheres of 100 nm, while the unconfined was the free Fe3O4 nanoparticles well-dispersed in the liquid via PAA surface coating. Assuming the identical core MNPs in each system, the heating behavior was analyzed in terms of particle freedom (or confinement), interparticle spacing, and magnetic coupling (or dipole-dipole interaction). DC magnetization data were correlated to the heating behavior with different material properties. Analysis of DC magnetization measurements showed deviation from classical Langevin behavior near saturation due to dipole interaction modification of the MNPs resulting in a high magnetic anisotropy. It was found that the Specific Absorption Rate (SAR) of the unconfined nanoparticle systems were significantly higher than those of confined (the MNPs embedded in the polystyrene matrix). This increase of SAR was found to be attributable to high Néel relaxation rate and hysteresis loss of the unconfined MNPs. It was also found that the dipole-dipole interactions can significantly reduce the global magnetic response of the MNPs and thereby decrease the SAR of the nanoparticle systems.

36 MATERIALS SCIENCE↗

Understanding how single-atom site density drives the performance and durability of PGM-free Fe–N–C cathodes in anion exchange membrane fuel cells

One of the most important needs for the future of low-cost fuel cells is the development of highly active platinum group metal (PGM)-free catalysts. For the oxygen reduction reaction, Fe–N–C materials have been widely studied in both acid and alkaline media. However, reported catalysts in the literature show quite different intrinsic activity and in-cell performance, despite similar synthesis routes and precursors. Here, two types of Fe–N–C are prepared from the same precursor and procedure – the main difference is how the precursor was handled prior to use. It is shown that in one case Fe overwhelmingly existed as highly active single-metal atoms in FeN4 coordination (preferred), while in the other case large Fe particles coexisting with few single metal atoms were obtained. As a result, there were drastic differences in the catalyst structure, activity, and especially in their performance in an operating anion exchange membrane fuel cell (AEMFC). Additionally, it is shown that catalyst layers created from single-atom-dominated Fe–N–C can have excellent performance and durability in an AEMFC using H 2 /O 2 reacting gases, achieving a peak power density of 1.8 W cm -2 – comparable to similar AEMFCs with a Pt/C cathode – and being able to operate stably for more than 100 h. Finally, the Fe–N–C cathode was paired with a low-loading PtRu/C anode electrode to create AEMFCs (on H 2 /O 2 ) with a total PGM loading of only 0.135 mg cm -2 (0.090 mg Pt cm -2 ) that was able to achieve a very high specific power of 8.4 W mg PGM -1 (12.6 W mg Pt< sup>-1 ).

36 MATERIALS SCIENCE↗

A Statistical Prescription to Estimate Properly Normalized Distributions of Different Particle Species

We describe a statistical method to avoid biased estimation of the content of different particle species. We consider the case when the particle identification information strongly depends on some kinematical variables, whose distributions are unknown and different for each particles species. We show that the proposed procedure provides properly normalized and completely data-driven estimation of the unknown distributions without any a priori assumption on their functional form. Moreover, we demonstrate that the method can be generalized to any kinematical distribution of the particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production

3D silicon sensors, where plasma micromachining is used to etch deep narrow apertures in the silicon substrate to form electrodes of PIN junctions, were successfully manufactured in facilities in Europe and USA. In 2011 the technology underwent a qualification process to establish its maturity for a medium scale production for the construction of a pixel layer for vertex detection, the Insertable B-Layer (IBL) at the CERN-LHC ATLAS experiment. The IBL collaboration, following that recommendation from the review panel, decided to complete the production of planar and 3D sensors and endorsed the proposal to build enough modules for a mixed IBL sensor scenario where 25% of 3D modules populate the forward and backward part of each stave. The production of planar sensors will also allow coverage of 100% of the IBL, in case that option was required. This paper will describe the processing strategy which allowed successful 3D sensor production, some of the Quality Assurance (QA) tests performed during the pre-production phase and the production yield to date.

47 OTHER INSTRUMENTATION↗

A large angle beamstrahlung monitor for EIC

This work presents a feasibility study for a Large Angle Beamstrahlung Monitor (LABM) at EIC. We show the results of a simulation used to calculate the beamstrahlung rates and how these rates are related to mismatches of the beams. Finally, we present the design of the LABM, discuss the results, and how to successfully employ the LABM at EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The MATHUSLA test stand

The rate of muons from LHC pp collisions reaching the surface above the ATLAS interaction point is measured as a function of the ATLAS luminosity and compared with expected rates from decays of W and Z bosons and b- and c- quark jets. In addition, data collected during periods without beams circulating in the LHC provide a measurement of the background from cosmic ray inelastic backscattering that is compared to simulation predictions. Data were recorded during 2018 in a 2.5 × 2.5 × 6.5 m 3 active volume MATHUSLA test stand detector unit consisting of two scintillator planes, one at the top and one at the bottom, which defined the trigger, and six layers of RPCs between them, grouped into three ( x, y )-measuring layers separated by 1.74 m from each other. Triggers selecting both upward-going tracks and downward-going tracks were used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗