Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas Receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Artificial Intelligence for Natural Gas Utilities: A Primer

Modern natural gas utilities face numerous challenges and competing priorities from various stakeholders. Policymakers, customers, and advocacy groups want to see gas utilities improve performance on safety, reliability, resilience, affordability, and environmental stewardship. State utility regulators — public utility commissions — are responsible for overseeing utility performance, ensuring that ratepayer funds are being spent in the public interest, and aligning utility goals with public goals. The use of new technologies is critical to enabling cost-effective performance on these attributes. Artificial intelligence (AI) is a widely used term among utilities and regulators, but the term means different things to different stakeholders, and it is often used to describe data analytics approaches that fall short of the formal definition of AI, which is: “…the ability of a machine to receive inputs and produce a behavior or reaction similar to that of an intelligent human being.” AI (and related tools, techniques, and technologies) can help utilities solve current and emerging challenges. By combining customer and system data with analytical tools and technologies, AI can augment human decision-makers by assisting in identifying problems and events before they occur, enabling resources to be more efficiently directed across utility infrastructure. The intended primary audience for this primer is state regulators, although utilities and other stakeholders might also find it useful and relevant to improve their awareness of AI. The objectives of this primer are to: (a) offer a set of broadly applicable definitions for AI and related terms, allowing regulators, utilities, and other stakeholders to speak the same language; (b) discuss how AI is currently being implemented in the gas utility sector; and (c) understand the challenges affecting AI solutions and how tools might be implemented in the future. This primer fits within NARUC’s goals of providing impartial information to improve the ability of public utility commissions to regulate in the public interest. As such, this primer does not seek to recommend AI over any other investment, nor does it endorse any particular vendor, product, or approach. It does seek to prepare state regulators to oversee AI investments by sharing information about the current landscape of commercially available tools. To these ends, the primer is organized as follows: Section I discusses the current environment in which natural gas utilities operate and how AI, when thoughtfully designed and implemented, can enable utilities to achieve performance goals; Section II offers definitions of AI and related terms within the data analytics discipline; Section III provides three current opportunities for which AI can offer solutions: replacing aging gas distribution infrastructure, preventing excavator damage to gas distribution infrastructure, and improving energy efficiency programs. This section discusses each problem statement in detail. Second, Section III includes a discussion of how costs and benefits of investments to solve each problem are measured. And third, this section offers real-world examples of utility implementation of AI solutions; Section IV discusses challenges with implementing AI, both from the perspective of utilities and regulators; Section V suggests areas in which AI could feasibly be implemented in the near future; Finally, Section VI offers concluding thoughts and areas for further research.

03 NATURAL GAS↗

Cell and method for electrolysis of water and anode

An electrolytic cell for converting water vapor to oxygen and hydrogen include an anode comprising a foraminous conductive metal substrate with a 65-85 weight percent iridium oxide coating and 15-35 weight percent of a high temperature resin binder. A matrix member contains an electrolyte to which a cathode substantially inert. The foraminous metal member is most desirably expanded tantalum mesh, and the cell desirably includes reservoir elements of porous sintered metal in contact with the anode to receive and discharge electrolyte to the matrix member as required. Upon entry of a water vapor containing airstream into contact with the outer surface of the anode and thence into contact with iridium oxide coating, the water vapor is electrolytically converted to hydrogen ions and oxygen with the hydrogen ions migrating through the matrix to the cathode and the oxygen gas produced at the anode to enrich the air stream passing by the anode.

Aylward, J. R.↗

Detection of Organic Constituents Including Chloromethylpropene in the Analyses of the ROCKNEST Drift by Sample Analysis at Mars (SAM)

key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.

Eigenbrode, J. L.↗

Fuel cell technology for lunar surface operations

Hydrogen-oxygen fuel cells have been shown, in several NASA and contractor studies, to be an enabling technology for providing electrical power for lunar bases, outposts, and vehicles. The fuel cell, in conjunction with similar electrolysis cells, comprises a closed regenerative energy storage system, commonly referred to as a regenerative fuel cell (RFC). For stationary applications, energy densities of 1,000 watt-hours per kilograms an order of magnitude over the best rechargeable batteries, have been projected. In this RFC, the coupled fuel cell and electrolyzer act as an ultra-light battery. Electrical energy from solar arrays 'charges' the system by electrolyzing water into hydrogen and oxygen. When an electrical load is applied, the fuel cell reacts the hydrogen and oxygen to 'discharge' usable power. Several concepts for utilizing RFC's, with varying degrees of integration, have been proposed, including both primary and backup roles. For mobile power needs, such as rovers, an effective configuration may be to have only the fuel cell located on the vehicle, and to use a central electrolysis 'gas station'. Two fuel cell technologies are prime candidates for lunar power system concepts: alkaline electrolyte and proton exchange membrane. Alkaline fuel cells have been developed to a mature production power unit in NASA's Space Shuttle Orbiter. Recent advances in materials offer to significantly improve durability to the level needed for extended lunar operations. Proton exchange membrane fuel cells are receiving considerable support for hydrospace and terrestrial transportation applications. This technology promises durability, simplicity, and flexibility.

Deronck, Henry J.↗

Reducing Seal Adhesion in Low Impact Docking Systems

Silicone elastomers, used in seals for airlocks or other sealing surfaces in space, are sticky in their as-received condition. Because of the sticking, a greater force may be needed to separate the mating surfaces. If the adhesion is sufficiently high, a sudden unpredicted movement of the spacecraft during undocking, vibration, or uneven release could pull off the seal, resulting in a damage that would have to be repaired before another docking. The damaged seal can result in significant gas leakage and possibly in a catastrophic mishap impacting the safety of the crew. It is also possible that a compromised seal could result in a delayed but sudden gas leak that could put the crew at unexpected risk. This is especially of concern for androgynous seals, which have identical mating surfaces on both sides for interchangeability and redundancy. Such seals typically have elastomer-on-elastomer sealing surfaces. To reduce sticking, one could use release agents such as powders and lubricants, but these can be easily removed and transferred to other surfaces, causing uneven sealing and contamination. Modification of the elastomer surface to make a more slippery and less sticky surface that is integral with the bulk elastomer would be more desirable.

Banks, Bruce A.↗

Carbon Monoxide in the Cold Debris of Supernova 1987A

We report spectroscopic and imaging observations of rotational transitions of cold CO and SiO in the ejecta of SN1987A, the first such emission detected in a supernova remnant. In addition to line luminosities for the CO J = 1-0, 2-1, 6-5, and 7-6 transitions, we present upper limits for all other transitions up to J = 13-12, collectively measured from the Atacama Large Millimeter Array, the Atacama Pathfinder EXperiment, and the Herschel Spectral and Photometric Imaging REceiver. Simple models show the lines are emitted from at least 0.01 M ☉ of CO at a temperature >14 K, confined within at most 35% of a spherical volume expanding at ~2000 km s-1. Moreover, we locate the emission within 1'' of the central debris. These observations, along with a partial observation of SiO, confirm the presence of cold molecular gas within supernova remnants and provide insight into the physical conditions and chemical processes in the ejecta. Furthermore, we demonstrate the powerful new window into supernova ejecta offered by submillimeter observations.

Cold↗

MSR Science Planning Group 2 (MSPG2): Science & Curation Considerations for Time Sensitive Measurements That Should be Performed in Containment

The Perseverance rover is currently collecting samples on the martian surface for potential return to Earth and planning is underway to develop facilities to study these samples. Perseverance will collect up to 38 samples that will be sealed in TiN tubes. As long as the tubes remain sealed the samples will be metastable. However, as soon as a tube is opened, or headspace gas is extracted these samples will begin to re-equilibrate with their new surroundings. The MSPG2 time-sensitive science sub-group attempted to quantify the rates at which alteration is likely to occur assuming the samples are opened and stored in a nitrogen atmosphere at room temperature. The group also recommended ~20 instruments for inclusion in a sample receiving facility to allow the time sensitive properties of these samples to be measured before they are irreversibly altered.

Aaron B Regberg↗

High angular resolution mm- and submm-observations of dense molecular gas in M82

Researchers observed CO(7-6), CO(3-2), HCN(3-2) and HCO+(3-2) line emission toward the starburst nucleus of M82 and have obtained an upper limit to H13CN(3-2). These are the first observations of the CO(7-6), HCN(3-2) and HCO+(3-2) lines in any extragalactic source. Researchers took the CO(7-6) spectrum in January 1988 at the Infrared Telescope Facility (IRTF) with the Max Planck Institute for Extraterrestrial Physics/Univ. of California, Berkeley 800 GHz Heterodyne Receiver. In March 1989 researchers used the Institute for Radio Astronomy in the Millimeter range (IRAM) 30 m telescope to observe the CO(3-2) line with the new MPE 350 GHz Superconductor Insulator Superconductor (SIS) receiver and the HCN(3-2) and HCO+(3-2) lines with the (IRAM) 230 GHz SIS receiver (beam 12" FWHM, Blundell et al. 1988). The observational parameters are summarized.

Wild, W.↗

Simple Approximation for the Ideal Reference State of Gases Adsorbed on Solid-State Surfaces

Reference states are useful as models for facilitating calculations of equilibrium constants, and they may also serve as standard states that are convenient for organizing and tabulating thermodynamic data; however, standard state conventions and appropriate reference states for adsorbed species have received less attention than those for pure substances and solutes. Here, we compare seven choices of reference states for calculations of equilibrium constants and transition state theory rate constants for flat surfaces, in particular (1) an ideal 2D harmonic oscillator, (2) an ideal rigid-molecule harmonic oscillator, (3) an ideal 2D harmonic oscillator with separable surface modes, (4) a 2D ideal gas, (5) an ideal 2D hindered translator, (6) an ideal 2D hindered translator with lowest-order barriers, and (7) a simple ideal 2D hindered translator proposed in this work. The advantage of models 5–7 is that they can treat both mobile and localized adsorbates in a consistent way, whereas models 1–3 are only appropriate for localized adsorbates, and model 4 is only appropriate for a freely translating adsorbate. Furthermore, models 6 and 7 reduce the computational cost without the user having to calculate barrier heights for diffusion. An advantage of the simple ideal 2D hindered translator is that it has a physical high-temperature limit. We also propose a reference state for nonflat surfaces. Here, the user is encouraged to choose a reference state based on the appropriateness of the model and the practicality of the calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards a Benchmark Experiment with the Compact Nuclear Power Source

The Compact Nuclear Power Source (CNPS) was a high-assay low enriched uranium (HALEU) tristructural isotropic (TRISO)-fueled, graphite-moderated microreactor constructed in 1987 at Los Alamos National Laboratory. The reactor, conceived as a power source for short-range radar stations, was designed to be "walk-away safe," and was cooled by heat pipes and ambient air. Though the project was formally cancelled after the fuel and moderator material had been received, its potential to meaningfully advance the body of critical and integral data was evident, and critical experiments with a mock-up of the reactor proceeded at TA-18 until its disassembly in 1991. The reflector and some components of the core would later go on to see service as part of the New Production Reactor Modular High-Temperature Gas-Cooled Reactor (NP-MHTGR) critical experiments. In light of the progress made by groups like Westinghouse and X-Energy towards contemporary graphite-moderated microreactors, the system remains an attractive candidate for the basis of a benchmark experiment even today. Uncertainties remain, however, in some features of the system–inconsistencies in the dimensions and composition of the reactor’s components as described in literature and implemented in current computational models. The identification, quantification, and to the extent possible, the minimization of these uncertainties is a crucial task on the path towards creating a benchmark based on the CNPS system. The present work seeks to initiate this process with a survey of available documentation and improvements to the accuracy of CNPS neutronics models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ detection of microbial respiration in soils and salt flats

Increase in CO2 partial pressures over a desert soil treated with casamino-acids glucose solution correlated with bacterial growth. Few or no increases in numbers of bacteria or CO2 concentrations were noted in similar plots treated with water only or receiving no treatment. Growth in the soil appeared to be severely nutrient limited during the 10 day experiment. Especially rapid growth took place between the third and fifth day, when temperatures ranged from 0 deg. (night) to a maximum of 17.4 deg. (day). Under the conditions of the experiment, intermittent CO2 assay was an insensitive indicator of growth, possibly because of restiction of gas escape by the desert pavement or solution, exchange, or precipitation of carbonate, but more likely because of inefficient sealing of hoods to and below the soil surface. CO2 assay was unable to detect microbial successions. The unpredictable course of these successions, plus unpredictable relative retentions mitigates against assay of organic gases as reliable in situ detection of microbial activity, except perhaps in very alkaline environments such as Owens Lake salts.

Tew, R. W.↗

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Comparison of advanced engines for parabolic dish solar thermal power plants

A paraboloidal dish solar thermal power plant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on small power modules which employ 11- to 12-meter diameter dishes to generate nominal power levels of approximately 20 kWe. A comparison of advanced heat engines for the dish power module is presented in terms of the performance potential of each engine with its requirements for advanced technology development. Three advanced engine possibilities are the Brayton (gas turbine), Brayton/Rankine combined cycle, and Stirling engines.

Fujita, T.↗

Contractors Road Heavy Equipment Area (SWMU 055) 2022 Annual Groundwater Monitoring Report

This document presents a summary of activities completed at the Contractors Road Heavy Equipment (CRHE) Area, located at Kennedy Space Center (KSC), Florida, from June through December 2022. The activities conducted at the CRHE Area include: - Annual groundwater sampling activities associated with sitewide plume monitoring and Underground Injection Control (UIC) monitoring in the former bioremediation Interim Measures (IM) Hot Spot 1 (HS1) area; - Direct push technology (DPT) groundwater investigation; - Semiannual vapor intrusion (VI) evaluation activities. This facility is designated Solid Waste Management Unit (SWMU) Number 055 (SWMU 055) under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action program. HydroGeoLogic, Inc. (HGL) prepared this report for the National Aeronautics and Space NASA) under contract number 80KSC019F0096/80KSC019D0012, Technical Directive-03. An Advance Data Package (ADP) presentation of the elements of this report received Team (KSCRT) agreement at the April 5, 2023, KSCRT meeting. The chlorinated volatile organic compound plume appears to be stable vertically and horizontally. Additional DPT groundwater sampling will be completed to support a remedial alternatives evaluation for potential means to expedite groundwater cleanup. There are per- and polyfluorinated alkyl substances in site groundwater, and assessment is planned in the future. Sub-slab soil gas monitoring results do not indicate any concerns with indoor vapor intrusion. Based on the 2022 annual groundwater sampling results, it is recommended that annual sampling continue to alternate with the wet and dry season, with the next sampling event planned for December 2023.

groundwater↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal study of the impact of stimulation pH on shale pore structure, with an emphasis on organics behavior in alkaline environments

The tight nature of shale formations calls for hydraulic fracturing techniques able of altering the pore architecture to facilitate the production of hydrocarbon resources. The composition, pH, salinity, density and chemistry of Hydraulic Fracturing Fluids (HFF) vary substantially depending on reservoir characteristics. pH is among the most important stimulation fluid properties, ranging from very acidic, for carbonate reservoirs, to basic, in the case of clay-rich formations. pH regulates what geochemical reactions take place between the stimulation fluid and shale, as well as pore architecture alteration. The dissolution of carbonates and pyrite, and the precipitation of common minerals such as barite, gypsum and iron oxides in acidic environments have been extensively documented. In contrast, alkali stimulation environments and the role of organic components have received less attention. This research provides insight into the role of both minerals and organic components during alkaline stimulation, and the resulting pore architecture alterations. Here, a set of reactive experiments are performed using three different shales, with varying organic matter (OM) content, at different pH (3, 6, 8, 10, 12). The analysis of pore architecture alteration induced by the reaction was performed via nitrogen (N2) gas adsorption and Time-Domain Nuclear Magnetic Resonance (TD-NMR). Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) was used to measure the composition of the stimulation fluid post-reaction. The system with a larger impact on the pore architecture (pH 12) underwent a more extensive analysis through the application of Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) and x-ray Diffraction (XRD). Results show that mineral dissolution contributed to the creation of secondary porosity, mainly through dissolution of clays and silicates. We show that the abundance and distribution of organic matter both play a significant role in changes in pore architecture. Most samples showed an increase in inter-organic porosity, likely due to the organic acids within kerogen reacting with the stimulation fluid. Samples with a larger amount and more widespread distribution of organic matter show the most significant alterations. Finally, we also highlight the dissolution process of iron-rich minerals, including framboidal pyrite, as another important source of secondary porosity.

04 OIL SHALES AND TAR SANDS↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗