Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRAPHITIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Preliminary analysis of graphite dust releasing behavior in accident for HTR

The behavior of the graphite dust is important to the safety of High Temperature Gas-cooled Reactors. This study investigated the flow of graphite dust in helium mainstream. The analysis of the stresses acting on the graphite dust indicated that gas drag played the absolute leading role. Based on the understanding of the importance of gas drag, an experimental system is set up for the research of dust releasing behavior in accident. Air driven by centrifugal fan is used as the working fluid instead of helium because helium is expensive, easy to leak which make it difficult to seal. The graphite particles, with the size distribution same as in HTR, are added to the experiment loop. The graphite dust releasing behavior at the loss-of-coolant accident will be investigated by a sonic nozzle. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lessons Learned from the Application of Bulk Characterization to Individual Containers on the Brookhaven Graphite Research Reactor Decommissioning Project at Brookhaven National Laboratory - 12056

When conducting environmental cleanup or decommissioning projects, characterization of the material to be removed is often performed when the material is in-situ. The actual demolition or excavation and removal of the material can result in individual containers that vary significantly from the original bulk characterization profile. This variance, if not detected, can result in individual containers exceeding Department of Transportation regulations or waste disposal site acceptance criteria. Bulk waste characterization processes were performed to initially characterize the Brookhaven Graphite Research Reactor (BGRR) graphite pile and this information was utilized to characterize all of the containers of graphite. When the last waste container was generated containing graphite dust from the bottom of the pile, but no solid graphite blocks, the material contents were significantly different in composition from the bulk waste characterization. This error resulted in exceedance of the disposal site waste acceptance criteria. Brookhaven Science Associates initiated an in-depth investigation to identify the root causes of this failure and to develop appropriate corrective actions. The lessons learned at BNL have applicability to other cleanup and demolition projects which characterize their wastes in bulk or in-situ and then extend that characterization to individual containers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long history of Cl-36 Assessment of Graphite Waste by EDF Engineering and the Latest Suggested Developments - 17043

Prior to 2005, the EDF initial version for the radiological inventory of graphite was based on the maximum values of the measures, namely a very pessimistic way. In 2008, a scientific method was developed by EDF to evaluate the inventory by reverse activation calculation, in order to limit the overestimation. The radiological inventory computation principles can be compared to those of all engineering studies. First, the calculation is simplified by taking margins, and if the results are not satisfactory enough, some simplifications are suppressed to reduce these margins even if computation becomes more complicated. On EDF piles, the gain obtained in 2008 represented a factor 50 relative to the initial version of Cl-36, even with a very penalizing multiplicative factor for uncertainty. Today, the accurate calculation of the uncertainty no longer justifies such a factor. A gain of about 150 now occurs compared to the initial version of Cl-36. It is more than 2 orders of magnitude, which is already enough to assess again the necessary type of disposal because Cl-36 is one of the key radionuclides. After global presentation of graphite waste management in France, the paper focuses on the inventory scientific process of EDF nuclear graphite, the purity of graphite and its consequences, its particular sampling, the lessons learned, the initial method description, the link with the demonstration of the completely random point process of chlorine in nuclear graphite and the last suggested precise uncertainty computation of inventory of Cl-36. The method confirmation for concentration assessment, the history of the EDF method development and its benefits are also emphasized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Graphite Dust Deposition on HTGR Steam Generator: Effect of Particle-wall Impact - 18520

Generated by abrasion of fuel spheres, graphite dust is an important issue for the operation and maintenance of high-temperature gas-cooled reactor (HTGR), since the transport of fission product is closely coupled with graphite dusts. AVR experiments on dust specific radioactivity indicate that graphite dust deposition on steam generator (SG) should be of special interest. Most previous simulations on graphite dust deposition assume a hit-and-stick nature for particles, which may overestimate the deposition rate. In this work we uses a critical velocity model to account for particle-wall interaction. Combined with computational fluid dynamics simulation and discrete phase method, the deposition of graphite dust in the upper 22 layers of SG tubes was studied with particle-wall interaction considered. The result shows that the deposition rate is highly overestimated if hit-and-stick is assumed. For particles larger than 5 {mu}m, the difference can be as large as 3 times. Particle deposition rate reaches maximum at about 3 {mu}m. As for the spatial distribution, few particles deposit on the first layer of tubes due to relative low Stokes number while more depositions occur after entering bundle zone, which indicates that the unsteady wake among tubes could be a major mechanism for the deposition. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Irradiation test about oxidation-resistant graphite in WWR-K research reactor - 18533

Graphite materials are used for the in-core components of High Temperature Gas-cooled Reactor (HTGR). It is desirable to enhance oxidation resistance of graphite to keep much safety margin. SiC coating is the candidate method for this purpose. JAEA and four Japanese graphite companies, Toyo Tanso, Ibiden, Tokai Carbon and Nippon Techno-Carbon are studying to develop oxidation-resistant graphite for the in-core components. Neutron irradiation test with two capsules was carried out by WWR-K research reactor of Institute of Nuclear Physics of the Republic of Kazakhstan (INP) through the International Science and Technology Center (ISTC) partner project. The total irradiation cycles of WWR-K operation was 10 cycles and the total duration was 200 days. Irradiation temperature about 1473 K would be attained. The maximum fast neutron fluence (E>0.18 MeV) for the gas-swept capsule irradiated at a central irradiation hole was preliminary calculated as 1.2x10{sup 25} m{sup -2}, and for the sealed capsule at a peripheral irradiation hole as 4.2x10{sup 24} m{sup -2}. Dimension and weight of the irradiated specimens were measured, and outer surface of the specimens were observed by optical microscope. For the irradiated oxidation resistant graphite, out-of-pile oxidation test will be carried out at an experimental laboratory. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-supervised learning approach for crack detection and identification in advanced gas-cooled reactor graphite bricks - 111

One of the life-limiting components of an Advanced Gas cooled Reactor (AGR) is its graphite core. The bricks present in the core undergo radiolytic oxidation throughout their lifetime which causes graphite weight loss and irradiation which can result in some of the bricks developing cracks. Understanding the nature and extent of brick cracking within the core is key to ensuring continued and extended operation of the AGR fleet. A semi-supervised machine learning classification algorithm is proposed as a method for improving the detection of cracked graphite bricks, by combining the labels derived from infrequent, detailed inspections of the core, with unlabeled, more frequent monitoring measurements taken during refueling operations. Semi-supervised machine learning, which is an emerging field in nuclear power condition monitoring, is the combination of ideas from both supervised and unsupervised machine learning whereby the data that is used to train the algorithm is a combination of labeled and unlabeled data. This paper introduces the initial research that has been undertaken in creating a semi-supervised self-training algorithm to detect the presence of graphite brick cracks and then proceeds to show that there is an improvement in the classification of graphite bricks using a semi-supervised machine learning classifier compared to supervised machine learning classifiers. This improved classification performance is encouraging as it does not require time consuming and costly human analysis to obtain extra learning information from available data. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mixed effects associated with air ingress in graphite channels

The next generation of nuclear power plants, such as Modular High Temperature Gas-Cooled Reactors (MHTGR), have passive safety design features to overcome transients during off-normal operation but it is unproven whether their safety systems will perform as per design requirements. The design and construction of a facility, to investigate the passive safety response of the complete reactor system will require significant resources. Therefore, a practical approach is to improve the understanding of this multi-physics or mixed effect problem in laboratory scale set-ups and computational models. The HTGR related separate effects experiments at academic institutions and other laboratories have been developed to provide validation data and complement computational efforts to identify critical issues related to passive safety design. There are several separate effect experimental studies currently under investigation or recently conducted by several academic institutions in U.S and throughout the world. The High Temperature Test Facility (HTTF) has been constructed at Oregon State University to conduct integral thermal-hydraulics experiments for the development of HTGRs. For Depressurized Conduction Cooling (DCC) experiments in HTTF, a mixture of nitrogen and helium gas is used to study internal natural convection up to 650?C. Similarly many other experimental studies have emphasized on HTGR core and plenum-to-plenum thermal-hydraulic behavior but with inert gases such as nitrogen or non-oxidizing solid substitutes for graphite. There is limited experimental data of mixed oxidation effects upon air ingress in nuclear grade graphite leading changes to thermal properties, heat generation due to chemical reactions and natural convection of air-helium mixture inside core at high temperatures (above 900?C). This work describes a unique experimental set-up developed by authors to conduct these mixed effect experiments. The current work is equally relevant to the designs well known by other names or geometries such as Very High Temperature Reactors (VHTRs) and Pebble Bed Modular Reactors (PBMRs). A common feature of HTGRs with passive safety design is that under certain accident conditions the decay heat is dissipated passively from the core by radiation/conduction/convection heat transport to the surrounding environment. Passive decay heat removal is one of the prime passive safety features of HTGRs and the heat conduction through the internal core region, graphite matrix, to the periphery is one of the major mechanisms of passive safety in HTGRs. The conduction and radiation heat transfer provide long-term heat removal but, during a Depressurized Loss of Forced Coolant (DLOFC) accident, the anticipated break in the coolant system will allow air ingress into the hot core region and can lead to graphite oxidation, which will negatively impact the core thermal behavior. In addition, air will also impact natural circulation of Helium and thus diminish the heat removal rate, which can further increase the graphite temperature. Therefore, both air ingress can eventually give rise to thermal instabilities and then to possible situations for breaching the safety envelope of TRISO fuel. This research summary is organized to present the background on oxidation studies, description of experimental setup and discussion of results in the following sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Structure and Phase Transitions of Monolayers of Intermediate-length n-alkanes on Graphite Studied by Neutron Diffraction and Molecular Dynamics Simulation

We present evidence from neutron diffraction measurements and molecular dynamics (MD) simulations of three different monolayer phases of the intermediate-length alkanes tetracosane (n-C(24)H(50) denoted as C24) and dotriacontane (n-C(32)H(66) denoted as C32) adsorbed on a graphite basal-plane surface. Our measurements indicate that the two monolayer films differ principally in the transition temperatures between phases. At the lowest temperatures, both C24 and C32 form a crystalline monolayer phase with a rectangular-centered (RC) structure. The two sublattices of the RC structure each consists of parallel rows of molecules in their all-trans conformation aligned with their long axis parallel to the surface and forming so-called lamellas of width approximately equal to the all-trans length of the molecule. The RC structure is uniaxially commensurate with the graphite surface in its [110] direction such that the distance between molecular rows in a lamella is 4.26 A=sqrt[3a(g)], where a(g)=2.46 A is the lattice constant of the graphite basal plane. Molecules in adjacent rows of a lamella alternate in orientation between the carbon skeletal plane being parallel and perpendicular to the graphite surface. Upon heating, the crystalline monolayers transform to a 'smectic' phase in which the inter-row spacing within a lamella expands by approximately 10% and the molecules are predominantly oriented with the carbon skeletal plane parallel to the graphite surface. In the smectic phase, the MD simulations show evidence of broadening of the lamella boundaries as a result of molecules diffusing parallel to their long axis. At still higher temperatures, they indicate that the introduction of gauche defects into the alkane chains drives a melting transition to a monolayer fluid phase as reported previously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating design safety margins in the American Society of Mechanical Engineers graphite core components design-by-analysis assessments

Graphite is an important material being used for core components in next-generation high-temperature gas-cooled nuclear reactors. The selection of graphite grade for a specific Designer is a complex task, dependent on reactor conditions, component functionality, and required reliability. The American Society of Mechanical Engineers (ASME) provides two semi-probabilistic design-by-analysis assessments to evaluate graphite core components against design reliability targets. The simplified assessment uses a 2-parameter Weibull distribution to describe the graphite grade’s tensile-strength distribution to establish component stress limits. The full assessment uses the 3-parameter Weibull distribution and a modified Weakest-Link Theory approach to calculate a component design probability of failure. The paper defines recommended assessment rules, which are the as-written simplified assessment and the full assessment with parameter lower bounds, the modulus update with threshold reduction, and the 2027 grouping rules. Code rules are applied to three grades: 2114, IG-110, and NBG-18. The baseline margin calculation is developed using the experimental tensile dogbone specimen. Percent margin is defined as the percent reduction in the median experimental load to obtain the allowable load per ASME assessments. Under the recommended rules, the SRC–1 margin in the simplified assessment ranged from 40.2 % to 52.7 % among the grades in this study and from 36.1 % to 49.8 % in the full assessment. The full assessment only decreases the margins by 2.5–4.5 % for the SRC-1 components and 0–1.5 % for the SRC-2 components for this baseline case. Margin is inversely related to material median strength (i.e., the strongest grade, 2114, has the lowest margin).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Binder-Free Graphite Anodes for Next-Generation High-Performance Lithium-Ion Batteries

High-energy density anodes are crucial for next-generation lithium-ion batteries (LIBs) particularly for electric vehicle (EV) applications. Sluggish lithium-diffusion kinetics coupled with conventional anode fabrication processes containing polymeric binders hinder fast-charging capabilities and high-energy density of graphite. Herein, we introduce a binder-free graphite anode fabrication strategy using the electrospinning technique that contains ~2.41% carbon nanotubes (CNTs). Our strategy relies on the formation of an interconnecting conductive CNT network coupled with an ultrathin N-doped carbon coating on graphite particles from sacrificial binders. This combination enhances both structural integrity and electrical conductivity and, in turn, improves fast-charging capabilities and high energy density of LIBs. The binder-free graphite anode achieves ~335.0 mAh g–1 capacity at C/3 rate over 400 cycles with capacity retention of >95% and average Coulombic efficiencies >99.95%. These promising results suggest that the binder-free anode fabrication with a multifunctional design approach could elevate the energy-density limits of the graphite anodes, solving high-energy density requirements of EVs, and potentially provides a path forward for the development of economically feasible energy storage systems for various applications.

Ozcan, Muca [ORNL] (ORCID:0000000320020474)↗

A new perspective on density and strength loss profiles at the surface of thermally oxidized nuclear graphite

Oxidation of graphite components could influence their designed life in a high-temperature nuclear reactor. The oxidized regions could potentially lower the allowed stress capacity. The American Society of Mechanical Engineers rules for the design and construction of graphite-moderated reactors recommend that subsurface regions that might become excessively damaged by oxidation during reactor operation be identified and excluded from geometry and stress calculations. Identification of oxidation-affected regions is possible, in principle, through complex modeling exercises of reactor behavior during hypothetical accident scenarios coupled with graphite oxidation models, but this procedure may not have the precision needed for informed decisions. Here, this paper proposes an alternate method, based on interpretation of a series of well-designed oxidation experiments, which could augment the designer's tools. The procedure is illustrated by data on oxidation by air of several graphite grades (NBG-18, PCEA, IG-110, R4-650) that are corroborated with independent literature information, when available. The Wichner model for graphite oxidation used for this analysis provides conservative results that could be quickly implemented in the design process.

36 MATERIALS SCIENCE↗

Electrochemical and impedance investigation of the effect of lithium malonate on the performance of natural graphite electrodes in lithium-ion batteries

Lithium malonate (LM) was coated on the surface of a natural graphite (NG) electrode, which was then tested as the negative electrode in the electrolytes of 0.9 M LiPF6/EC-PC-DMC (1/1/3, by weight) and 1.0 M LiBF4/EC-PC-DMC (1/1/3, by weight) under a current density of 0.075 mA cm-2. LM was also used as an additive to the electrolyte of 1.0 M LiPF6/EC-DMC-DEC (1/1/1, by volume) and tested on a bare graphite electrode. It was found that both the surface coating and the additive approach were effective in improving first charge discharge capacity and coulomb efficiency. Electrochemical impedance spectra showed that the decreased interfacial impedance was coupled with improved coulomb efficiency of the cells using coated graphite electrodes. Cyclic voltammograms (CVs) on fresh bare and coated natural graphite electrodes confirmed that all the improvement in the half-cell performance was due to the suppression of the solvent decomposition through the surface modification with LM. The CV data also showed that the carbonate electrolyte with LM as the additive was not stable against oxidation, which resulted in lower capacity of the full cell with commercial graphite and LiCoO2 electrodes.

additive↗

Extreme fast charge aging: Effect of electrode loading and NMC composition on inhomogeneous degradation in graphite bulk and electrode/electrolyte interface

Empowering extreme fast charging (XFC) requires a comprehensive understanding of its application with advanced anode and cathode materials in lithium-ion batteries. No report exists for the full extent of limitations for the anode with crosstalk effect from paired cathode as well as Li plating due to electrode loading under XFC. In this study, a combination of cell testing and multiple length characterization is used to investigate XFC aging mechanism in cells with a low loading of 1.5 mAh cm -2 and high loading of 2.5 mAh cm -2 for graphite (Gr)/Ni-rich LiNi x Mn y Co 1-x-y O 2 (NMCs). Operando XRD mappings show 1.5 mAh cm -2 loadings result in higher strain in graphite for all three cathode types. Among the three NMC cathodes, the graphite from NMC532 and NMC811 cells show comparable strain. Scanning electron microscopy (SEM) images show distinct differences between 6-C-charged anodes in two loadings. Significantly increased electrode thickness can be seen due to more damage in the graphite bulk and accumulation of the electrolyte decomposition products in electrode pores. X-ray photoelectron spectroscopy (XPS) reveals both cathode chemistry and Li plating influence the non-uniform SEI composition on graphite surface. We report higher Ni content in NMC811 promotes the higher levels of salt decomposition on the SEI and formation of higher mass of electrolyte aging products.

25 ENERGY STORAGE↗

Anisotropic Tuning of Graphite Thermal Conductivity by Lithium Intercalation

Understanding thermal transport in lithium intercalated layered materials is not only important for managing heat generation and dissipation in lithium ion batteries but also the understanding potentially provides a novel way to design materials with reversibly tunable thermal conductivity. In this work, the thermal conductivity of lithium–graphite intercalation compounds (Li x C 6 ) is calculated using molecular dynamics simulations as a function of the amount of lithium intercalated. We found that intercalation of lithium has an anisotropic effect on tuning the thermal conductivity: the thermal conductivity in the basal plane decreases monotonically from 1232 W/m·K of pristine graphite to 444 W/m·K of the fully lithiated LiC 6 , while the thermal conductivity along the c-axis decreases first from 6.5 W/m·K for graphite to 1.3 W/m·K for LiC 18 and then increases to 5.0 W/m·K for LiC 6 as the lithium composition increases. More importantly, we provide the very first atomic-scale insight into the effect of lithium intercalation on the spectral phonon properties of graphite. The intercalated lithium ions are found to suppress the phonon lifetime and to reduce the group velocity of phonons parallel to the basal plane but significantly to increase the phonon group velocity along the c-axis, which anisotropically tunes the thermal conductivity of lithiated graphite compounds. This work could shed some light on the search for tunable thermal conductivity materials and might have strong impacts on the thermal management of lithium ion batteries.

25 ENERGY STORAGE↗

Nanosecond formation of diamond and lonsdaleite by shock compression of graphite

Here, the shock-induced transition from graphite to diamond has been of great scientific and technological interest since the discovery of microscopic diamonds in remnants of explosively driven graphite. Furthermore, shock synthesis of diamond and lonsdaleite, a speculative hexagonal carbon polymorph with unique hardness, is expected to happen during violent meteor impacts. Here, we show unprecedented in situ X-ray diffraction measurements of diamond formation on nanosecond timescales by shock compression of pyrolytic as well as polycrystalline graphite to pressures from 19 GPa up to 228 GPa. While we observe the transition to diamond starting at 50 GPa for both pyrolytic and polycrystalline graphite, we also record the direct formation of lonsdaleite above 170 GPa for pyrolytic samples only. Our experiment provides new insights into the processes of the shock-induced transition from graphite to diamond and uniquely resolves the dynamics that explain the main natural occurrence of the lonsdaleite crystal structure being close to meteor impact sites.

36 MATERIALS SCIENCE↗

Advanced rechargeable aluminium ion battery with a high-quality natural graphite cathode

There has been some interest in aluminium ion batteries with aluminium anodes, graphite cathodes and ionic liquid electrolytes has increased; however, much remains to be done to increase the cathode capacity and to understand details of the anion–graphite intercalation mechanism. An aluminium ion battery cell made using pristine natural graphite flakes achieves a specific capacity of B110 mAhg -1 with Coulombic efficiency B98%, at a current density of 99mAg -1 (0.9 C) with clear discharge voltage plateaus (2.25–2.0 V and 1.9–1.5 V). The cell has a capacity of 60mAhg -1 at 6 C, over 6,000 cycles with Coulombic efficiency B 99%. Raman spectroscopy shows two different intercalation processes involving chloroaluminate anions at the two discharging plateaus, while C–Cl bonding on the surface, or edges of natural graphite, is found using X-ray absorption spectroscopy. Lastly, theoretical calculations are employed to investigate the intercalation behaviour of choloraluminate anions in the graphite electrode.

25 ENERGY STORAGE↗

Structures and localized vibrational states of defects in graphite by tight-binding calculations

The structural and vibrational properties of pristine graphite and point defects in graphite are studied by tight-binding (TB) calculations using a three-center TB potential model. We showed that the three-center TB potential without ‘‘ad hoc’’ van der Waals interaction corrections can accurately describe the inter-layer distance of graphite and the lowest-energy structures and stabilities of typical point defects in graphite. The results from our TB calculations are in good agreement with those from density-functional theory calculations with van der Waals interaction corrections. We also investigated the vibrational properties to gain better understanding on the localization of vibrational states induced by the point defects. Our calculation results show that although localized or quasi-localized vibrational modes can be found in all defected graphite, the localization induced by Frenkel pair, dual-vacancy, and dual-interstitial defects is much stronger. Atomic displacements associated with the localized vibrational modes induced by these three point defects are also analyzed

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Co-intercalation-free ether electrolytes for graphitic anodes in lithium-ion batteries

Carbonate-based electrolytes are widely used in Li-ion batteries but are limited by a small operating temperature window and poor cycling with silicon-containing graphitic anodes. The lack of non-carbonate electrolyte alternatives such as ether-based electrolytes is due to undesired solvent co-intercalation that occurs with graphitic anodes. Here, we show that fluoroethers are the first class of ether solvents to intrinsically support reversible lithium-ion intercalation into graphite without solvent co-intercalation at conventional salt concentrations. In full cells using a graphite anode, they enable 10-fold higher energy densities compared to conventional ethers, and better thermal stability over carbonate electrolytes (operation up to 60 °C) by producing a robust solvent-derived solid electrolyte interphase (SEI). As single-solvent–single-salt electrolytes, they remarkably outperform carbonate electrolytes with fluoroethylene carbonate (FEC) and vinylene carbonate (VC) additives when cycled with graphite–silicon composite anodes. In conclusion, our molecular design strategy opens a new class of electrolytes that can enable next generation Li-ion batteries with higher energy density and a wider working temperature window.

25 ENERGY STORAGE↗