Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Faulting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Temporal Convolutional Network Using Empirical Mode Decomposition to Detect Faults in Grid Connected Systems

Grid-connected power electronic systems require timely and reliable fault detection to prevent equipment damage and reduce downtime. This paper presents a forecasting-based anomaly detection pipeline that decomposes voltage and current measurements into intrinsic mode functions (IMFs) using empirical mode decomposition (EMD), then trains a causal temporal convolutional network (TCN) on normal-operation IMF data to predict short-horizon future dynamics. Deviations between forecasts and observations are summarized as reliability-weighted residual scores and thresholded per sensor using robust statistics with temporal persistence constraints to suppress false positives. To reduce runtime, EMD is performed on downsampled signals for detection, while raw-rate EMD is applied only within a short region of interest for high-frequency interpretability near detected events. Results on a simulated grid-connected converter system demonstrate that IMF-domain forecasting improves anomaly separability relative to raw-signal forecasting and provides interpretable evidence of faults across decomposition channels.

Sutton, Elizabeth [ORNL] (ORCID:0009000078885935)↗

Inverter Design with High Short-Circuit Fault Current Contribution to Enable Legacy Overcurrent Protection for Islanded Microgrids

The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.

Ferrari Maglia, Max↗

Phasor-Domain Modeling of Inverter Based Resources Considering Unbalanced Grid Faults

A significant increase in inverter-based distributed energy resources (DERs) is expected in distribution systems of the near future. The latest phasor modeling approach of DERs with emerging control technologies can capture relevant dynamics in large-scale three-phase distribution systems with unbalanced construction. However, there is a lack of appropriate phasor models to deal with unbalanced fault scenarios. As such, this paper describes per-phase phasor modeling approach appropriate for unbalanced grid disturbance studies in distribution systems with high penetration of DERs. The overall modeling performance of representative DERs is simulated in phasor domain GridLAB-D environment and validated against controller hardware-in-the loop (CHIL) testing or electromagnetic transient (EMT) based switching model simulation in PSCAD with test cases including different unbalanced grid faults. The high accuracy retained from the simulation verifies the effectiveness of the proposed phasor modeling approach considering interactions between positive and negative sequence signals.

Chen, Zhe↗

Exploring Capability of Multimodal Foundation Model for Image-based Fault Detection of Photovoltaic Modules

Multimodal Foundation Model (MFM), like ChatGPT and Gemini, have emerged as powerful tools for their exceptional natural language processing capabilities and their emerging potential in image analysis. This paper investigates the application of MFMs for photovoltaic (PV) fault detection through image analysis, focusing on ChatGPT 4.0 and Gemini 1.5 Pro. Three types of PV images and the corresponding common PV faults are detected: bird droppings using visible images, cell cracks via electroluminescence (EL) images, and hotspots using infrared (IR) images. Among the two models, Gemini 1.5 Pro demonstrated superior performance, achieving near-perfect results with an average F1 score of 0.97, consistently outperforming ChatGPT 4.0 in accuracy and reliability. Unlike traditional machine learning (ML) models, MFMs can operate in a zero shot manner that does not require additional training by the user, and the input images are not limited by size, angle, scope, or PV technology. The strong adaptability and user-friendliness make MFM a promising tool for analyzing PV images and advancing health monitoring for PV modules.

Li, Baojie↗

Fault-Tolerant Deep Learning Cache with Hash Ring for Load Balancing in HPC Systems

Large-scale DL on HPC systems like Frontier and Summit uses distributed node-local caching to address scalability and performance challenges. However, as these systems grow more complex, the risk of node failures increases, and current caching approaches lack fault tolerance, jeopardizing large-scale training jobs. We analyzed six months of SLURM job logs from Frontier and found that over 30% of jobs failed after an average of 75 minutes. To address this, we propose fault-tolerance strategies that recache data lost from failed nodes using a hash ring technique for balanced data recaching in the distributed node-local caching, reducing reliance on the PFS. Our extensive evaluations on Frontier showed that the hash ring-based recaching approach reduced training time by approximately 25% compared to the approach that redirects I/O to the PFS after node failures and demonstrated effective load balancing of training data across nodes.

Lee, Seoyeong↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Protection Software to classify fault locations by protective zone in distribution systems with high PV penetration

The software contains (a) the source codes to generate Point-on-Wave (PoW) transient data for any feeder model in Alternative Transient Program (ATP) format. Codes provide options to change different steady state settings, including the loading condition and PV capacity and transient state setting like faults type, location and initiation time (b) data post-processing source code to converted data from native format to COMTRADE, csv, HDF5 (c) Docker container to train CNN to classify fault locations by protective zone. The container takes dataset and other training parameters (sampling rate, training epochs, batch size etc) as input to train CNN. The container writes back the trained CNN model, training and testing metrics and plots to the local workstation

Ramesh, Meghana↗

Blockchain-based fault tolerant grid operations system

To maintain/improve the distribution system fault-tolerance for a grid with high penetration of distributed energy resources requires improvement, Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain's core features of distributed consensus-based decision-making process and immutability.

Bereta dos Reis, Fernando↗

Incorporating Full Elastodynamic Effects and Dipping Fault Geometries in Community Code Verification Exercises for Simulations of Earthquake Sequences and Aseismic Slip (SEAS)

ABSTRACT Numerical modeling of earthquake dynamics and derived insight for seismic hazard relies on credible, reproducible model results. The sequences of earthquakes and aseismic slip (SEAS) initiative has set out to facilitate community code comparisons, and verify and advance the next generation of physics-based earthquake models that reproduce all phases of the seismic cycle. With the goal of advancing SEAS models to robustly incorporate physical and geometrical complexities, here we present code comparison results from two new benchmark problems: BP1-FD considers full elastodynamic effects, and BP3-QD considers dipping fault geometries. Seven and eight modeling groups participated in BP1-FD and BP3-QD, respectively, allowing us to explore these physical ingredients across multiple codes and better understand associated numerical considerations. With new comparison metrics, we find that numerical resolution and computational domain size are critical parameters to obtain matching results. Codes for BP1-FD implement different criteria for switching between quasi-static and dynamic solvers, which require tuning to obtain matching results. In BP3-QD, proper remote boundary conditions consistent with specified rigid body translation are required to obtain matching surface displacements. With these numerical and mathematical issues resolved, we obtain excellent quantitative agreements among codes in earthquake interevent times, event moments, and coseismic slip, with reasonable agreements made in peak slip rates and rupture arrival time. We find that including full inertial effects generates events with larger slip rates and rupture speeds compared to the quasi-dynamic counterpart. For BP3-QD, both dip angle and sense of motion (thrust versus normal faulting) alter ground motion on the hanging and foot walls, and influence event patterns, with some sequences exhibiting similar-size characteristic earthquakes, and others exhibiting different-size events. These findings underscore the importance of considering full elastodynamics and nonvertical dip angles in SEAS models, as both influence short- and long-term earthquake behavior and are relevant to seismic hazard.

Geochemistry & Geophysics↗

Basement Fault Activation before Larger Earthquakes in Oklahoma and Kansas

Oklahoma and Kansas experienced unprecedented seismic activity over the past decade due to earthquakes associated with unconventional hydrocarbon development. The modest natural seismicity and incomplete knowledge of the fault network in the region made it difficult to anticipate the locations of earthquakes with larger magnitudes (M w ≥ 4). Here, we show that monitoring of microearthquakes at regional scale using a pretrained neural phase picker and an earthquake relocation algorithm can illuminate unknown fault structures, and deliver information that can be synthesized for earthquake forecasting. We found that 80% of the larger earthquakes that occurred in the past decade could have been anticipated based on the spatial extent of the seismicity clusters that were formed before these earthquakes occurred. We also found that once a seismicity cluster with a length scale enough to host a larger earthquake was formed, there was a ~5% chance that it would host one or more larger earthquakes within a year. This probability is nearly an order of magnitude higher than one based on Gutenberg–Richter statistics and preceding seismicity. Applying our approach in practice can provide critical information on seismic hazards for risk management and regulatory decision making.

58 GEOSCIENCES↗

Curation of Ground-Truth Validated Benchmarking Datasets for Fault Detection & Diagnostics Tools

Fault detection and diagnostics (FDD) analytical tools for heating, ventilation and air conditioning (HVAC) systems represent one of the most active areas of smart building technology development. A diversity of techniques is used for FDD analytics, spanning physical models, black box, and rule-based approaches, and researchers continuously strive to develop improved algorithms. With FDD algorithm numbers now in the hundreds, there is a need for performance evaluation of these algorithms in order to assess improvements, improve costeffectiveness, and to prioritize investment in the further development of these technologies. A persistent challenge of FDD advance has been the lack of common datasets to benchmark the performance accuracy of FDD algorithms. This paper summarizes the successful curation of HVAC operational data, paired with validated ground-truth information regarding the presence and absence of faults. The current dataset, consisting of both simulation and experimental data, will evolve to include a larger set of HVAC systems with the objective of creating the largest publicly available dataset to be used by FDD developers, users, and researchers to compare and contrast performance accuracy across FDD algorithms, helping to drive improvements that will spur greater market adoption of FDD tools. Furthermore, in order to avoid previously observed issues with contributed datasets and ensure high quality and consistency of future submissions, the development of data validation and ground-truth assessment protocol is detailed in this study.

Casillas, Armando↗

Literature Review for Sensor Impact Evaluation and Verification Use Cases - Building Controls and Fault Detection and Diagnosis (FDD)

This report summarizes a comprehensive literature review for the selected sensor suites used in building controls and fault detection and diagnostics (FDD), which is a Q2 deliverable of the Sensor Impact Evaluation and Verification project. The project’s overarching goal is to develop a framework for investigating the impact of sensor deployment and configuration for building energy optimization, fault detection and diagnosis (FDD), occupants’ thermal comfort, and potential grid efficiency. While the first phase of the literature review performed in Q1 reviewed the current methods of various sensor selection and placements and their impact, this report focuses on high impactful potential use cases for the selected sensor suites in building control and FDD. The use cases identified in this literature review will be further investigated and be included in the final sensor impact evaluation framework. For the review, the multi-laboratory team reviewed 241 research papers, technical reports, and books to identify existing technologies, the potential impact on energy savings and thermal comfort, and future research opportunities for the selected use cases in building controls and FDD. Along with the literature review, the team conducted a series of interviews with experts in sensors and controls area to identify the state-of-art sensor technologies, and the most impactful use cases in controls and FDD areas. The interview results will also be incorporated with the findings from the literature review in the next quarter, and the final use cases to be evaluated will be selected.

47 OTHER INSTRUMENTATION↗

Compressor is A Sensor: A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The primary goal of this report is to develop a universal charge fault detection method that requires only a few experimental data with high prediction accuracy. Currently, pump-down operations is typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repair. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The new charge fault detection and diagnostics method innovatively utilizes the typical pump down operation, the compressor’s low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.

42 ENGINEERING↗

Blockchain for Fault-Tolerant Grid Operations

Radial topology and vast geographic coverage make distribution systems prone to widespread power outages upon the failure of a single (or multiple) upstream component. Fault-handling algorithms depend heavily on correct estimations of the system’s state to effectively isolate the affected area and reduce the number of affected customers while maintaining operational safety. The work described here leverages the core features of distributed, consensus-based decision-making processes and the immutability of blockchain, and demonstrates their value in improving fault-tolerant grid operations. In this work, blockchain was used to create a trusted data-sharing platform that enables independent actors to reconstruct the system state; this enables distributed resources to make intelligent decisions with limited knowledge. Although the process requires data sharing, its algorithms have been designed to limit the amount of private information that is exchanged, which helps preserve business-sensitive data and maintain customer privacy. In addition, by reducing the information that must be shared, the communication requirements are also reduced; (however, an in-depth analysis of the communication requirements is beyond the scope of this project). The proposed use cases are intended to represent a foundational basis for third parties to develop functional solutions that can eventually be deployed in the field. To further provide guidance, the envisioned use cases have incorporated design requirements that consider the blockchain characteristics and a need to limit information from surrounding resources, which preserve the assumption and the possibility that such resources could belong to different entities. This report presents a detailed design of the three use cases with the tools needed to enable the analysis being tested. The implemented gross error detection method can detect mismatches when the error exceeds 3.8 times the sensor’s rated accuracy. Detection of the circuit breaker state successfully identified the correct states across all simulation tests. A distribution-system power-flow solution in the simulator OpenDSS generally possesses a convergency tolerance of 0.01% on the voltage magnitude. The evaluation of possible reconnection using voltage magnitude—preserving the data ownership—has a voltage magnitude difference smaller than 0.001% from the OpenDSS result. The results preserving data ownership have a difference within the expected power flow tolerance with full knowledge of the system, which surpasses expectations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Triaxial Shear Tests on Simulated Sierra White Fault Gouge & Borehole Simulation in Sierra White Gouge

Laboratory shear tests were conducted on pulverized Sierra White granite (SWG) to investigate slip mechanisms in naturally occurring faults. Synthetic fault geometries were constructed by sandwiching fine grained SWG powder in between steel forcing blocks. For dry experiments, ~3.5 g of SWG powder was poured onto the face of the lower steel forcing block and leveled. For saturated experiments, enough fluid was added to the ~3.5 g of Sierra White granite powder to form a slurry. This slurry was applied to the lower forcing block and leveled. Inclined forcing blocks with 25.4 mm diameter and 35° faces, which were machined from ground steel rods with fine teeth on the faces, help to hold the gouge in place and prevent delamination at the interface. The top forcing block had a 2.03 mm centered hole to allow pore fluid access to the gouge. A fine steel mesh prevented back flow of the gouge into pore fluid lines. Samples were isolated from the confining medium using three layers of heat shrink polyolefin, as shown in Figure 1. The outer layer was shrunk over the o-rings on the end caps to form an impermeable seal, which was reinforced with steel tie wires on both sides of the o-rings. Hardened steel spacers and copper shim stock was placed between the steel forcing blocks and the end caps to preserve the parallelism of the Hastelloy wetted parts. For dry samples, the end caps were plugged, while the end caps for the saturated samples were connected to pore lines.

58 GEOSCIENCES↗

3D Geologic Framework Modelling of the Los Alamos National Laboratory Site and Pajarito Plateau: Integrating a realistic 3D fault network and modelling subsurface relationships in a sparsely sampled and complex geologic region

The subsurface geology beneath the Pajarito Plateau is critical to understanding the seismic hazard of the Pajarito Fault System, yet our understanding of this geology is relatively poor. While previous 3D geologic framework models of the area have been created for the purposes of understanding hydrogeologic flow, they are inadequate for the purposes of understanding the Pajarito Fault System. The specific challenges of using oil and gas software for this purpose include: (1) the geologic complexities resulting from volcanism and tectonism; (2) a need for a high level of stratigraphic detail over a large area; (3) a near complete lack of seismic data; and (4) sparse wellbore data. Presented here is a workflow that handles these challenges of adapting commercially available software used by the oil and gas industries to this seismic hazard problem.

58 GEOSCIENCES↗

Spread Spectrum Time Domain Reflectometry (SSTDR) Digital Twin Simulation of Photovoltaic Systems for Fault Detection and Location

Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.

14 SOLAR ENERGY↗