Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Common Definition for Zero Energy Buildings

Thousands of project teams throughout the country seek to push the envelope and develop zero energy buildings. Generally speaking, a zero energy building produces enough renewable energy to meet its own annual energy consumption requirements, thereby reducing the use of nonrenewable energy in the building sector. This definition also applies to campuses, portfolios, and communities. In addition to providing clarity across the industry, this publication provides guidelines for measurement and implementation, specifically explaining how to utilize this definition for building projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of Numerical Model of Metal Foam with PCM for the Estimation of Effective Thermal Conductivity

Global warming due to climate change is a threat to humankind. Nuclear energy is one of the promising solutions to reduce fossil fuel usage. Nuclear energy can handle the base load, compensating for the volatility of renewable energy. If nuclear energy could achieve load following capability, the combination with renewable energy would be more suitable. Thermal energy storage (TES) is one of the options for enabling load following of nuclear reactors. The TES makes it possible to store surplus nuclear thermal energy and release it later as needed. In Idaho National Laboratory (INL), a new concept of latent heat TES integrated with high-temperature heat pipe has been proposed and is under development, which is called Heat pipe-Integrated Thermal Battery (HITB). HITB exchanges thermal energy between the reactor system and TES via heat pipe. The heat transferred to TES medium, made of phase change material (PCM), stores energy as sensible heat and/or latent heat. As PCM typically has poor thermal conductivity, however, various heat transfer enhancement techniques are required to achieve a rapid charging cycle. There are many techniques to enhance the heat transfer ability of TES medium such as disk, fin, and metal foam. Among them, metal foam is an appropriate option to enhance the heat transfer because it maximizes the heat transfer area through metal wicks. Metal foam is a lightweight metal structure that has a high porosity of over 0.9. The typical materials for metal foam are Aluminum, Copper, Nickel, and Silicon Carbide (SiC). Metal foam not only enhances heat transfer via conduction but also increases contact surface area. In the HITB design , the metal foam is being considered as one of the options to enhance the heat transfer of TES medium (PCM) [1]. To predict the enhanced thermal performance of TES, one should properly estimate the effective thermal conductivity of metal foam combined with PCM material or calculate heat transfer in distributed model. There are many experimental works that provides effective thermal conductivity of metal foam with various PCM [2,3]. Also, many theoretical models were developed based on the unit cell model of metal foam [4,5]. With a distributed model, on the other hand, detail heat transfer characteristics between metal foam and PCM material can be analyzed considering the geometry or buoyancy effect. However, due to the complex geometry of metal foam pores, the computational cost for three-dimensional modeling highly increases. Therefore, if metal foam structure can be modeled in simple and repetitive design, the computational cost would decrease Among the various metal foam models [2], lattice model is one of the simple and extendable design. The porosity and pores per inch (PPI) can be characterized by the size and spatial distance of lattice structure. If the three-dimensional metal foam model consists of lattice structure could properly estimate the heat transfer, which is characterized by effective thermal conductivity, it would be a good option to assess the thermal performance of metal foam with PCM. In this study, a three-dimensional numerical model was developed to simulate conductive heat transfer between metal foam and PCM. The three-dimensional lattice structure of square pillars was selected as a basic structure of the metal foam. The calculation result was characterized by the effective thermal conductivity of the whole domain. A sensitivity study was conducted for mesh size, domain size, and PPI to check whether the calculation result gives a converged result or not. Lastly, the effective thermal conductivity from the lattice model was compared with existing experimental data to validate the model result

25 ENERGY STORAGE↗

Audit Report "Department of Energy Efforts to Manage Information Technology Resources in an Energy-Efficient and Environmentally Responsible Manner"

The American Recovery and Reinvestment Act of 2009 emphasizes energy efficiency and conservation as critical to the Nation's economic vitality; its goal of reducing dependence on foreign energy sources; and, related efforts to improve the environment. The Act highlights the significant use of various forms of energy in the Federal sector and promotes efforts to improve the energy efficiency of Federal operations. One specific area of interest is the increasing demand for Federal sector computing resources and the corresponding increase in energy use, with both cost and environmental implications. The U.S. Environmental Protection Agency reported that, without aggressive conservation measures, data center energy consumption alone is expected to double over the next five years. In our report on Management of the Department's Data Centers at Contractor Sites (DOE/IG-0803, October 2008) we concluded that the Department of Energy had not always improved the efficiency of its contractor data centers even when such modifications were possible and practical. Despite its recognized energy conservation leadership role, the Department had not always taken advantage of opportunities to reduce energy consumption associated with its information technology resources. Nor, had it ensured that resources were managed in a way that minimized impact on the environment. In particular: (1) The seven Federal and contractor sites included in our review had not fully reduced energy consumption through implementation of power management settings on their desktop and laptop computers; and, as a consequence, spent $1.6 million more on energy costs than necessary in Fiscal Year 2008; (2) None of the sites reviewed had taken advantage of opportunities to reduce energy consumption, enhance cyber security, and reduce costs available through the use of techniques, such as 'thin-client computing' in their unclassified environments; and, (3) Sites had not always taken the necessary steps to reduce energy consumption and resource usage of their data centers, such as identifying and monitoring the amount of energy used at their facilities. We concluded that Headquarters programs offices (which are part of the Department of Energy's Common Operating Environment) as well as field sites had not developed and/or implemented policies and procedures necessary to ensure that information technology equipment and supporting infrastructure was operated in an energy-efficient manner and in a way that minimized impact on the environment. For example, although required by the Department, sites had not enabled computer equipment power management features designed to reduce energy consumption. In addition, officials within Headquarters programs and at the sites reviewed had not effectively monitored performance or taken steps to fully evaluate available reductions in energy usage at their facilities. Without improvements, the Department will not be able to take advantage of opportunities to reduce energy consumption and realize cost savings of nearly $23 million over the next five years at just the seven sites reviewed. We noted that the potential for reduced energy consumption at these sites alone was equivalent to the annual power requirements of over 2,400 homes or, alternatively, removing about 3,000 cars from the road each year. Many of the available energy reduction strategies, such as fully utilizing energy-efficient settings on the many computers used by the Department and its contractors, are 'low hanging fruit' in that they will provide immediate tangible energy savings at little or no cost. Others, such as a shift to thin-client computing, an environment that transfers the processing capabilities from an individual's desk to a shared server environment, will require some level of investment which can, based on available literature, be successfully recovered through reduced acquisition and support costs. In our judgment, given its highly visible leadership in energy issues, aggressive action should be taken to make the Department's information technology operations as energy efficient as possible so that it can serve as a role model for both the Federal and private sector. To its credit, the Department had increased the number of energy-efficient computers purchased in recent years. In addition, the Office of the Chief Information Officer implemented an automated computer shutdown program at Headquarters that was estimated to save up to nearly $400,000 per year. Furthermore, we found that certain sites had initiated actions to review a potential transition to unclassified thin-client computing; however, implementation had not yet been completed. These are positive steps, but additional action is required, and our report contains several recommendations to this end.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and evaluation of a prototype concentrating solar collector with thermocline based thermal energy storage for residential thermal usage

A prototype of a concentrating solar collector (CSC) receiver was designed, built, and evaluated on-sun at the University of Texas at El Paso in El Paso, TX. This prototype receiver consists of two parabolic trough-reflectors but, in principle, the design can be efficiently extended to multiple units for achieving a higher temperature throughput. Each reflector has a vacuum tube collector at the focal point of the trough. The solar collector system was combined with a single-tank thermocline thermal energy storage (TES) for off-solar thermal usage. The main goal of this study is to develop an advanced solar hot water system for most residential applications. The focus of this study is to investigate the feasibility and performance of the solar thermal system by employing the recent advancement in the TES—a thermocline based TES—system for the concentrating solar power technologies developed by the Sandia National Laboratories and National Renewable Energy Laboratories for electricity production. A CSC when combined with TES has potential to provide uninterrupted thermal energy for most residential usages. This paper presents a detailed description of prototype design and materials required. The thermal energy storage tank utilizes an insulated 170 l (45 gal) galvanized steel tank. In order to maintain thermocline in the TES tank, with hot water on top and cold water at the bottom, two plate distributors are installed in the tank. The data showed a significant enhancement in thermal energy generation. This thermocline based single tank presented a thermal energy storage potential for at least three days (with diminishing storage capacity) that test were performed. The whole prototype was made for approximately USD 355 (excludes any labor costs) and hence also has strong potential for supplying clean thermal energy in most developing countries. As a result, tests of the prototype were conducted in November 2011.

14 SOLAR ENERGY↗

The Energy and Environmental Performance of Ground-Mounted Photovoltaic Systems—A Timely Update

Given photovoltaics’ (PVs) constant improvements in terms of material usage and energy efficiency, this work provides a timely update on their life-cycle energy and environmental performance. Single-crystalline Si (sc-Si), multi-crystalline Si (mc-Si), cadmium telluride (CdTe) and copper indium gallium diselenide (CIGS) systems are analysed, considering the actual country of production and adapting the input electricity mix accordingly. Energy pay-back time (EPBT) results for fixed-tilt ground mounted installations range from 0.5 years for CdTe PV at high-irradiation (2300 kWh/(m 2 ·yr)) to 2.8 years for sc-Si PV at low-irradiation (1000 kWh/(m 2 ·yr)), with corresponding quality-adjusted energy return on investment (EROI PE-eq ) values ranging from over 60 to ~10. Global warming potential (GWP) per kWh el averages out at ~30 g(CO 2 -eq), with lower values (down to ~10 g) for CdTe PV at high irradiation, and up to ~80 g for Chinese sc-Si PV at low irradiation. In general, results point to CdTe PV as the best performing technology from an environmental life-cycle perspective, also showing a remarkable improvement for current production modules in comparison with previous generations. Finally, we determined that one-axis tracking installations can improve the environmental profile of PV systems by approximately 10% for most impact metrics.

14 SOLAR ENERGY↗

Melting/freezing points of high concentrations of AlCl 3 in a saturated chloroaluminate ionic liquid

Melting/freezing points of AlCl 3 in saturated chloroaluminate ionic liquids [molar ratio 2:1 AlCl 3 :1-ethyl-3-methyl imidazolium chloride (EMIC)] are measured by differential scanning calorimetry (DSC). A critical range of temperature data (50-130 °C) for AlCl 3 dissolution and precipitation from saturated chloroaluminate ionic liquids is obtained. This range of temperature data is of significance to control phase transition of AlCl 3 in saturated chloroaluminate ionic liquids. By applying the chloroaluminate ionic liquids to electrolytes for energy storage usage, solid AlCl 3 can be partially dissolved and precipitated out during the charging/discharging cycle of energy storage equipment. Furthermore, the energy density of the electrolytes is expected to be greatly improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intelligent Control of Thermal Energy Storage in the Manufacturing Sector for Plant-Level Grid Response

Industrial facilities are seeking new strategies that help in providing savings mechanisms for demand charges. Demand charges are the charges incurred by industrial facilities as a result of power usage. Thermal energy storage has advanced significantly with lots of new applications, garnering the interest of many industrial facilities. These applications could be used to shave the industrial facilities’ peak electric demand and reduce their demand charges. This paper aims to demonstrate the efficacy of thermal energy storage in reducing demand charges and highlight new developments in the integration of smart control systems with thermal energy storage. The study compares energy consumption and peak demand for a facility equipped with and without thermal energy storage tanks using a fixed schedule for charging and discharging. Additionally, the paper examines the impact of incorporating a smart controller to determine when to charge and discharge the tank based on the facility’s real-time power usage and a given setpoint. The results indicate cost savings from the use of thermal energy storage tanks under two proposed scenarios, reflected in the reduced cost of power consumption for the studied facility. The incorporation of a smart controller with the thermal energy storage tank in the facility studied could provide estimated savings of 3.3% per year of power consumption charges, without considering the contribution of any incentives. The estimated savings provided by the fixed schedule scenario are 2.7% per year.

25 ENERGY STORAGE↗

Nuclear-Integrated Energy Units: Advancing Cybersecurity for Resilient Energy Systems

Rapidly increasing usage of nuclear-integrated energy units has created new challenges in terms of cybersecurity. This paper discusses the potential cyberthreat challenges and cyber risks associated with the widespread adoption of these units, and the role of artificial intelligence (AI) and machine learning (ML) techniques in enhancing the security and resilience of these systems.

20 FOSSIL-FUELED POWER PLANTS↗

Study of Codes & Standards for Energy Storage Systems: A Report to Congress

The Infrastructure Investment and Jobs Act (H.R. 3684, 2021) directed the Secretary of Energy to prepare a report identifying the existing codes and standards for energy storage technologies. The stated goals for the report are to enhance the safe development of energy storage systems by identifying codes that require updating and facilitation of greater conformity in codes across different types and usages of energy storage technologies. This paper will focus on the specific codes and standards for stationary energy storage systems (ESS).

25 ENERGY STORAGE↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

Industrial Locomotive Inventory Analysis

Due to their captive and local operations, industrial locomotives present a unique potential to reduce energy consumption and associated costs through application of advanced locomotive technologies. However, until now, there has been no data source for the number, size (hp), usage, and energy consumption of these locomotives, which limits the ability to design and implement a research, development, and deployment strategy. This research addresses this gap by developing the first national inventory of locomotives in industrial use and provides a tool to explore the energy and emissions associated with this transportation segment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying the chemical and structural irreversibility in LiNi 0.8 Co 0.15 Al 0.05 O 2 – a model compound for classical layered intercalation

In this work, we extracted 95% of the electrochemically available Li from LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA) by galvanostatically charging the NCA/MCMB full cell to 4.7 V. Joint powder X-ray and neutron diffraction (XRD & ND) studies were undertaken for NCA at highly charged states at the first cycle, and discharged states at different cycles. The results indicate that the bulk structure of NCA maintains the O3 structure up to the extraction of 0.90 Li per formula unit. In addition, we found that the transition metal layer becomes more disordered along the c-axis than along the a- and b-axes upon charging. This anisotropic disorder starts to develop no later than 4.3 V on charge and continues to grow until the end of charge. As Li is re-inserted during discharge, the structure that resembles the pristine NCA is recovered. The irreversible loss of Li and the migration of Ni to the Li layer have been quantified by the joint XRD and ND refinement and the results were further verified by solid state 7 Li NMR and magnetic measurements. Thus, our work clearly demonstrates that the NCA bulk retains a robust, single phase O3 structure throughout the wide delithiation range (up to 0.9 Li per formula unit of NCA) and is suitable for higher energy density usage with proper modifications.

25 ENERGY STORAGE↗

Quantitative assessment of sustainable remediation options for the M-1 air stripper system at SRS - 15702

The US Department of Energy (DOE) Savannah River Site (SRS) covers 310 sq. miles and is located south of Aiken, SC. The site produced materials used in the production of nuclear weapons from the 1950's to the 1980's. Trichloroethylene (TCE) and tetrachloroethylene (PCE) were the main solvents used in degreasing and other industrial operations. These solvents are categorized as dense non-aqueous phase liquids (DNAPLs), semi-volatile, and hazardous chemical compounds. In the 1980's, operations were initiated to remediate the contaminated soil and groundwater which continues today. The M-1 air stripper and well network has operated continuously since 1985 at an average electrical load of 150 kW and flow rate of 420 gpm. The influent TCE concentration to the air stripper has decreased exponentially from 25,200 ug/L in 1986 to 2,230 ug/L by the end of 2012, with the same energy consumption and water pumping rate. To analyze the operation of the SRS A/M Area groundwater remediation system using state-of-the-art modeling tools to provide suggested engineering and operational improvements to expend less resources while still containing the contaminant plume. Implementation of improvements will help DOE-EM apply sustainable remediation at its sites and help DOE achieve DOE-wide sustainability performance metrics. Located in the northern part of SRS within the lower reaches of the Tims Branch watershed (topographic elevation from ∼420 X to ∼ 118 X). Consists of facilities that fabricated reactor fuel and target assemblies (M-Area), and administrative and support facilities (A-Area). M-1 Air Stripper and Recovery Well Network Installed in 1985 to treat groundwater in order to reduce chlorinated solvent concentrations. 17 recovery wells have been installed over the years. Currently recovery wells 1-12 feed the M1 air stripper. The treated groundwater is discharged to a stream in Tims Branch. The monthly removal rate and the cumulative mass removed for TCE and PCE in the 12 recovery wells was analyzed for 1985-2012. 7 of 12 recovery wells have transitioned to more PCE than TCE removed. This is an expected result since TCE was initially used and then replaced by PCE. The rate of recovery in some wells was affected by the Dynamic Underground Stripping process. 7 wells exhibit exponential decay in contaminant removal while 5 exhibit steady concentrations, and 2 exhibit linear decreases. Future Work: Identify opportunities to improve efficiencies related to electrical energy, water usage, and the use of other resources, beginning with mechanical design modifications. Investigate operational strategies to increase system performance by optimizing the hydraulic loads, pumping rates, contaminant mass flow rates and well drawdown levels. Determine a set of metrics which will correlate the pumping rates, the cone of depression, and the interaction between the wells with the contaminant mass flow rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D printing of packaging inserts from biomass-fungi composites: Environmental sustainability analysis

In this study, a comprehensive Life cycle assessment (LCA) is conducted on molded packaging inserts from expanded polystyrene (EPS) foam, molded packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the low mix / high volume (LMHV) scenario and molded and machined packaging inserts from EPS foam, molded and machined packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the high mix / low volume (HMLV) scenario. Six environmental impact categories—climate change, acidification, eutrophication, fossil resource scarcity, land use, and water consumption—are analyzed to evaluate the environmental trade-offs associated with each type of packaging inserts. Under the LMHV scenario, molded packaging inserts from biomass-fungi composite emerge as the best option due to their lower impact on climate change, acidification and water consumption compared to other types of packaging inserts. Conversely, molded packaging inserts from biomass-fungi composite face challenges in land use and eutrophication, primarily due to raw material production. LCA also reveals that 3D-printed packaging inserts from biomass-fungi composite are the most environmentally favorable option under the HMLV scenario, due to significantly lower contributions to climate change, eutrophication, and water consumption compared to other types of packaging inserts. Conversely, 3D-printed packaging inserts from biomass-fungi composite face challenges in acidification and land use, primarily due to raw material production. As part of the LCA, sensitivity analyses show that sourcing energy from 100% renewable sources substantially lowers climate change impacts across all packaging types, while varying transportation distances results in only minor changes, indicating the dominant role of upstream material and manufacturing processes. Additional sensitivity analysis is conducted under the HMLV scenario to assess the impact of material removal during machining on the environment. The amount of material removal is varied from 10 to 70% for the sensitivity analysis and it highlights that the amount of material removed during machining has no significant impact on climate change for packaging inserts from EPS foam. However, molded and machined packaging inserts from biomass-fungi composite show an increasing trend in climate change with higher amount of material removal, while 3D-printed packaging inserts from biomass-fungi composite exhibit a decreasing trend, driven by reduced raw material usage and energy consumption.

09 BIOMASS FUELS↗

Residential electricity conservation in response to auto-generated, multi-featured, personalized eco-feedback designed for large scale applications with utilities

While past research has shown that providing residents with feedback about their electricity usage can reduce demand and its associated environmental burdens, some questions remain regarding what makes such feedback most effective. We followed the electricity usage of 36 residents who each received 14 feedback messages over 2 months. Using approaches borrowed from Natural-Language-Processing, feedbacks were generated automatically, using 10 features in random combinations. Unlike in previous studies, each resident received varying types of messages over time. In 504 observations, the average prompted reduction in electricity usage was 11 ± 3%, compared to a control group of 89 residents who received no messages. Feedback types prompting the largest reductions were self-comparisons with one’s own earlier usage (average reduction 14%) and messages of high variety from one feedback-cycle to the next (average reduction 16%). Comparisons with neighbors did not prompt higher reductions on average. Instead, they prompted reductions only when a resident’s recent usage happened to be higher than the average usage of neighbors, and increases when the reverse was true. Finally, this behavior was exhibited by all residents and is likely explained by a norm-conforming mean reversion of residents to their neighbors’ average usage, rather than an anti-conform “boomerang” behavior previously suggested in similar contexts.

42 ENGINEERING↗