Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

On Hydrodynamics Generated from Electrostatic Discharges: A Heat Source Perspective

A parameter space map of a heat source depositing energy into a cylindrical spark channel modeling the hydrodynamic effects of an electrostatic discharge event is explored. The four parameters of spatial weight, λ R , rise time, τ r , fall time, τ f , and energy per unit length deposited in to the system, E 0 /h, were varied to observe resulting hydrodynamic phenomena. The energy budget con-sequences of the associated hydrodynamic flow are discussed in terms of the remaining electrical energy available for the joule heating of sensitive energetic materials (or “victims”) are discussed,where hydrodynamic simulations are validated by experimental data. Future results and conclusions will be added to this report as they are produced.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Azimuthal and axial structures in 3D particle-in-cell simulation of Penning discharge

We report the results of a 3D particle-in-cell simulation of cylindrical Penning discharge with the axial magnetic field in the so-called reflex configuration, where the cathode and anti-cathode are biased to the same negative potential. The discharge is supported by thermal electron emission from the cathode. Electron and ion collisions, including ionization, are fully accounted for. The emphasis is on a specific regime in which the plasma potential at the center of the discharge is positive with respect to the chamber walls, serving as an anode. Spatial and temporal scales of the observed azimuthal and axial fluctuations and structures are characterized. It is suggested that azimuthal structures are caused by the dissipative gradient-drift instability. We find that the axial fluctuations related to the plasma-beam instabilities are weakly correlated with the azimuthal perturbations of the density, so that the azimuthal modes rotate as a whole and do not show any axial shear. The behavior of the electric potential is more involved, demonstrating intermittent standing wave and propagating structures in the axial direction that modulate the electron transport, producing the standing wave pattern (along the z-direction) in the radial electron flux.

3D PIC simulation of discharge↗

Non‐Linear Kinetics of The Lithium Metal Anode on Li 6 PS 5 Cl at High Current Density: Dendrite Growth and the Role of Lithium Microstructure on Creep

Abstract Interfacial instability, viz., pore formation in the lithium metal anode (LMA) during discharge leading to high impedance, current focusing induced solid–electrolyte (SE) fracture during charging, and formation/behaviour of the solid–electrolyte interphase (SEI), at the anode, is one of the major hurdles in the development of solid‐state batteries (SSBs). Also, understanding cell polarization behaviour at high current density is critical to achieving the goal of fast‐charging battery and electric vehicle. Herein, via in situ electrochemical scanning electron microscopy (SEM) measurements, performed with freshly deposited lithium microelectrodes on transgranularly fractured fresh Li6PS5Cl (LPSCl), the LiǀLPSCl interface kinetics are investigated beyond the linear regime. Even at relatively small overvoltages of a few mV, the LiǀLPSCl interface shows non‐linear kinetics. The interface kinetics possibly involve multiple rate‐limiting processes, i.e., ion transport across the SEI and SE|SEI interfaces, as well as charge transfer across the LiǀSEI interface. The total polarization resistance R P of the microelectrode interface is determined to be ≈ 0.8 Ω cm 2 . It is further shown that the nanocrystalline lithium microstructure can lead to a stable LiǀSE interface via Coble creep along with uniform stripping. Also, spatially resolved lithium deposition, i.e., at grain surface flaws, grain boundaries, and flaw‐free surfaces, indicates exceptionally high mechanical endurance of flaw‐free surfaces toward cathodic load (>150 mA cm −2 ). This highlights the prominent role of surface defects in dendrite growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton deflectometry of a capacitor coil target along two axes

A developing application of laser-driven currents is the generation of magnetic fields of picosecond–nanosecond duration with magnitudes exceeding $B=10~\text{T}$. Single-loop and helical coil targets can direct laser-driven discharge currents along wires to generate spatially uniform, quasi-static magnetic fields on the millimetre scale. Here, we present proton deflectometry across two axes of a single-loop coil ranging from 1 to 2 mm in diameter. Comparison with proton tracking simulations shows that measured magnetic fields are the result of kiloampere currents in the coil and electric charges distributed around the coil target. Using this dual-axis platform for proton deflectometry, robust measurements can be made of the evolution of magnetic fields in a capacitor coil target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Electrostatic charge buildup and electrostatic discharge monitoring system and method

A system for monitoring electrostatic charge buildup and electrostatic discharge (ESD) remotely comprises a plurality of electrostatic charge measurement units and a data acquisition device. Each electrostatic charge measurement unit includes a primary charge plate, a static sensor device, a secondary charge plate, and a shielded cable. The primary charge plate is positioned proximal to an object. The static sensor device includes an input sensor at which an electric voltage is measured and outputs an electronic signal whose level varies according to the measured electric voltage. The secondary charge plate is positioned in proximity to the input sensor of the static sensor device. The shielded cable includes an inner conductor electrically connected to the primary charge plate and the secondary charge plate and an outer conductor electrically connected to electrical ground. The data acquisition device receives the electronic signal from the static sensor device of each electrostatic charge measurement unit.

Schantz, Eric T.↗

Financial Analysis of Experimental Releases Conducted at Glen Canyon Dam during Water Year 2021

This report was prepared by Argonne National Laboratory (Argonne) in support of a financial analysis of two Glen Canyon Dam (GCD) flow experiments that were conducted in Water Year 2021. The first experiment, called “spring disturbance flow”, was conducted from March 15 to 26, 2021. This disturbance flow experiment is designed to simulate a spring-timed runoff event so scientists can study its effects on the Colorado River ecosystem. The second experiment was a reduced and steady discharge from May 29 to June 4, 2021. This reduced steady flow experiment was conducted for the United States Geological Survey (USGS) to collect high-resolution aerial imagery over Grand Canyon National Park. This analysis was funded by the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy’s Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems Division prepared this technical memorandum with assistance from WAPA’s CRSP and Energy Marketing and Management Offices (EMMO).

58 GEOSCIENCES↗

Real-Time Acoustic Analysis of Batteries

The project explored development and commercialization of an acoustical approach to battery diagnostics. The technology has significant potential impacts for battery manufacturing and quality assurance, battery management during operation, and could be an enabler for the second-life battery market. Research was focused on inspecting and analyzing the physical condition of batteries using ultrasound. This consisted of designing and building hardware for gathering high-quality acoustic data, as well as using battery charge-discharge cyclers and temperature chambers to operate and age the batteries. Over the course of the 2-year program, we were able to build our first prototypes that are robust enough to be used by industry partners to evaluate our technology. Using the same prototypes, we also showed preliminary evidence that our acoustic inspection method may have distinct advantages over standard electrical methods in terms of detecting differences in the physical quality of battery cells. The project also expanded the participant’s core capabilities beyond time-of-flight acoustic measurements.

25 ENERGY STORAGE↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

A Comprehensive Experimental Study on Microstructure‐Graded Graphite Anodes for Enhancing Fast‐Charging Capability of Lithium‐Ion Batteries

Lithium‐ion batteries with high gravimetric capacity density and improved cycle life performance under fast‐charging conditions are crucial for widespread electric vehicle (EV) adoption. This study investigates how designing graphite anode microstructure, specifically porosity, and particle‐size gradients, improves lithium‐ion (Li + ) transport during fast‐charging conditions. Three‐layered graphite anodes with varying porosity (24%, 36%, 46%) and particle size gradients (3, 5, 10 μm) were compared to a conventional single‐layered electrode in half‐cell configurations. At room temperature and high discharge rate (2C), both gradient structures showed significantly enhanced capacity retention (80% and 67% vs. 50%) compared to the conventional electrode, highlighting the effectiveness of microstructure engineering for fast charging. The study also investigated the temperature's impact on cycle life. After 200 cycles at 2°C and 45°C, all gradient structures demonstrated superior capacity retention (≈80%) compared to the conventional electrode (35%), suggesting the gradients mitigate degradation rate at high temperatures. Electrochemical impedance spectroscopy confirmed superior Li+ diffusion and lower resistivity in gradient electrodes. Simulations explored the influence of gradient profiles on reaction kinetics across the electrode thickness. Overall, this research demonstrates that the fast‐charging capability of graphite electrodes can be greatly enhanced by engineering the electrode microstructure, thereby making EV technology more accessible and appealing.

Ahmadi, Soma↗

Semiconducting Zn x Mo 3 S 13 -GO Chalcocarbogel: A High-Capacity and Stable Sulfur-Equivalent Conversion-Based Electrode for Lithium-Ion Batteries

Lithium–sulfur batteries with a sulfur electrode offer a theoretical capacity of ∼1672 mAh g –1 , but rapid capacity loss mainly constrains their practical application. This work introduces a semiconducting and amorphous Zn x Mo 3 S 13 -GO (x = 0.5) chalcocarbogel sulfur-equivalent electrode with superior capacity and stability for lithium-ion batteries (LIBs). The Zn x Mo 3 S 13 -GO is synthesized in solution under ambient conditions, and its local structure contains S–S, M-Q (M = Mo, Zn; Q = S, O), C–S, and Mo–Mo bonding motifs with Mo coordination environment closely related to Mo 3 S 13 anions, as determined by X-ray photoelectron spectroscopy, synchrotron X-ray scattering, X-ray absorption spectroscopy, and ab initio molecular dynamics simulations. The Li/Zn x Mo 3 S 13 -GO cell offers an initial discharge capacity of 1019 mAh g –1 at a rate of C/3. After the activation cycles, the Li/Zn x Mo 3 S 13 -GO cell demonstrates good cycling stability, retaining a discharge capacity of 519.4 mAh g –1 after 250 cycles with ∼99.98% Coulombic efficiency and excellent rate capabilities. Moreover, it provides an initial discharge capacity of ∼574 mAh g –1 and maintains a retention capacity of 279 mAh g –1 at 1C after 625 cycles. The Lewis acidic Zn 2+ ion enhances the Lewis basic polysulfide anchoring ability and reduces the dissolution of polysulfides produced during the redox process through Zn–S covalent interaction, while the semiconducting and amorphous structure of the chalcocarbogel increases the electrical and ionic conductivity. Furthermore, this work highlights chalcocarbogels’ potential for developing high-capacity and stable electrodes for LIBs.

25 ENERGY STORAGE↗

Characterizing Physical Properties of Streambed Interface Sediments Using In Situ Complex Electrical Conductivity Measurements

Streambed sediment physical properties such as surface area, are difficult to quantify in situ but exert a high-level control on a wide range of biogeochemical processes and sorption of contaminants. We introduce the use of complex electrical conductivity (CC) methods (also known as spectral-induced polarization (SIP)) that measure both real and imaginary conductivity to noninvasively and efficiently characterize shallow streambed sediments. We explore the method through synthetic modeling, laboratory, and field measurements to demonstrate the sensitivity of imaginary conductivity to sediment surface area, controlled in part by fine-grained iron oxides produced by anoxic groundwater discharge. Laboratory measurements verify expected relationships between CC parameters and sediment properties. Synthetic modeling using a 1D analytical model illustrates the influence of water layer depth and conductivity on the field CC measurements made at the streambed-stream water interface. Specifically, the inverted sediment imaginary conductivity is less impacted by uncertainty in the water layer depth and conductivity relative to the real conductivity and phase shift. Field CC measurements along a landfill-impacted river reveal discrete streambed zones with enhanced bulk surface area generally corresponding to anoxic groundwater discharge zones with high concentrations of fine-grained iron oxide precipitates.

54 ENVIRONMENTAL SCIENCES↗

Advanced Water-Related Technology Performance Development

This U.S. Department of Energy/National Energy Technology Laboratory techno-economic analysis evaluates those parameters having the greatest performance and cost impact on wet flue gas desulfurization (FGD) effluent wastewater treatment systems, and air cooled condensers for dry cooling systems. Two supercritical pulverized coal power plants are considered: 1) an existing plant (modified for surface water discharge and air emissions consistent with limits for existing plants) retrofitted with wet FGD effluent wastewater treatment and 2) a greenfield plant constructed with an air-cooled condenser (ACC). Sensitivity analyses are completed on various process parameters associated with the wet FGD effluent wastewater treatment system and ACC to determine the impact on the net plant efficiency and levelized cost of electricity (LCOE). Research and development targets are recommended for the parameters shown to have the greatest potential impact on cost or performance.

20 FOSSIL-FUELED POWER PLANTS↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Distinct Dynamics of Lithium Intercalation and Plating on Graphite Anode for Li‐Ion Batteries in eVTOL Applications

In the absence of viable high-energy-density battery alternatives, lithium-ion (Li-ion) batteries remain essential for enabling electric vertical take-off and landing (eVTOL) platforms in advanced air mobility. Unlike Li-ion batteries used in electric vehicles and portable electronics, eVTOL battery systems operate under distinct high-power demands, which necessitate an independent assessment of material degradation mechanisms. This study presents a case analysis of graphite anode evolution under high-power cycling conditions. The findings reveal lithium entrapment within graphite particles, potentially resulting from incomplete Li-ion de-intercalation during a high-rate discharge event that is characteristic of eVTOL take-off and landing. This phenomenon leads to a progressive reduction in graphite-specific capacity and, over time, promotes lithium metal plating on the anode. Notably, the Li-metal plating observed in this study differs from that associated with fast-charging conditions, as it is primarily governed by concentration polarization-induced overpotential in the latter case. In conclusion, these findings highlight the inherent challenges of utilizing graphite in high-power Li-ion battery applications and elucidate the unique degradation mechanisms that arise due to the sluggish reaction kinetics of Li-ion intercalation and de-intercalation within graphite.

Li plating↗

Treatment of brackish water for fossil power plant cooling

In this study, we evaluated the technical, economic and environmental impacts of retrofitting brackish groundwater treatment systems at existing coal- and gas-fired electric generating units (EGUs) to reduce freshwater consumption in wet cooling towers. Based on fleet averages, retrofitting brackish water treatment systems decreases unit freshwater consumption by 94–100%, while increasing the cost of electricity generation by 8–10%. The unit capacity shortfalls are less than 1.1%. The resulting cost of freshwater consumption savings by brackish water treatment is US$1.7 m -3 and US$2.9 m -3 on average for coal- and gas-fired EGUs, respectively. However, these trade-offs are highly affected by the brine disposal method. The use of thermal zero liquid discharge for brine disposal can roughly double the average cost of freshwater consumption savings. The cost-effectiveness of brackish water treatment compared with dry cooling deployment depends on how concentrated brines are managed. In conclusion, the identified trade-offs and their dependence fill knowledge gaps to better inform water management.

20 FOSSIL-FUELED POWER PLANTS↗

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗