Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric Generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

W.A. Parish Post-Combustion CO 2 Capture and Sequestration Demonstration Project (Final Technical Report)

The Petra Nova Project (Project) is a commercial scale post-combustion carbon capture project developed by a joint venture between NRG Energy, Inc. (NRG) and JX Nippon Oil Exploration (EOR) Limited (JX). The Project is designed to separate and capture carbon dioxide (CO2) from an existing coal-fired unit’s flue gas slipstream at NRG’s W.A. Parish Electric Generating Station (WAP) located southwest of Houston, Texas. The captured CO2 is dried, compressed, and transported via an 81-mile pipeline to the West Ranch oilfield (West Ranch) in Jackson County, Texas, where it is injected to boost oil production. The Project, which is partially funded by a grant (Grant) from the United States (U.S.) Department of Energy (DOE) under the Clean Coal Power Initiative (CCPI) Round 3, uses the Kansai Mitsubishi Carbon Dioxide Recovery advanced amine-based CO 2 absorption technology (KM-CDR Process®), which was jointly developed by Mitsubishi Heavy Industries, Ltd. (MHI) and the Kansai Electric Power Co. Inc., to treat and capture at least ninety percent (90%) of the CO 2 from a 240-megawatt equivalent (MWe) flue gas slipstream off of Unit 8 at WAP. When operating at full capacity, the Project captures approximately 5,200 short tons of CO 2 per day, which would otherwise be emitted into the atmosphere, representing the largest commercial scale deployment of post-combustion CO2 capture technology at a coal power plant to date. Under the Grant, the Project was managed in 3 phases: (1) Phase 1: Project Definition / Front End Engineering Design (FEED) (2) Phase 2: Detailed Engineering, Procurement & Construction (3) Phase 3: Demonstration and Monitoring. On December 29, 2016, commercial operation of the Project was achieved, ending Phase 2 and starting Phase 3, a 3-year demonstration period running from January 1, 2017 through December 31, 2019. The key objectives of Phase 3 were to (a) demonstrate the specific advanced technologies constructed during Phase 2 and (b) monitor the injected CO 2 at West Ranch to demonstrate technologies and protocols for monitoring, verification, and accounting (MVA). As of the end of Phase 3, Petra Nova captured 3,904,978 short tons of CO 2 (3,542,537 metric tons) that was transported to West Ranch. To support the DOE obligation to monitor, verify, and account for the sequestered CO 2 at West Ranch, Petra Nova contracted with the Bureau of Economic Geology (in the Jackson School of Geosciences at The University of Texas at Austin) to (a) design a monitoring program, (b) draft an MVA Plan for DOE review and approval, and (c) working with Petra Nova and the operator of West Ranch to manage and report on the MVA activity. This report discussed the technical aspects of the project during each of the 3 phases of the project as identified above.

01 COAL, LIGNITE, AND PEAT↗

Grand Challenges Revisited: Wind Energy Research Needs for a Global Energy Transition

Wind will be a foundational energy source in the electricity grid at the heart of a future integrated energy system, replacing traditional electricity generators powered by fossil fuels and providing grid reliability services in addition to energy. Future capabilities and functions of the wind energy sector will evolve apace with the future expansion and needs of global energy infrastructure; however, wind turbines designed today will not be able to provide the services needed to form and stabilize the grid as a majority supplier. In 2017, organizers for the IEA Wind Technical Experts Meeting (TEM) #89 Grand Vision for Wind Energy workshop assembled a group of experts to consider the question of how to enable a future in which wind energy supplies more than 50% of global electricity consumption. More than 70 experts representing 15 countries attended the workshop and provided diverse perspectives for the Grand Vision for Wind Energy. The IEA Wind TEM #109 was a subsequent gathering that was convened Feb. 28-March 1, 2023, in Boulder, Colorado, USA. The IEA Wind TEM #109 meeting aimed to bring together the leaders of all working groups and the IEA Wind Technology Collaboration Programme (TCP) to identify gaps in scientific knowledge, design, and deployment practice as well as identify recommendations for collaborative pathways, initiatives, and prioritized long-term research needs that can be addressed by IEA Wind. This report captures the outcomes of this meeting of international experts: five Grand Challenge areas (The Atmosphere, The Turbine, The Plant and Grid, Environmental Co-Design, and Social Science). In addition, meeting participants identified eight crosscutting topic areas that are discusses within this report (Environment-Turbine, Turbine-Atmosphere, Atmosphere-Grid/Plant, Grid/Plant-Turbine, Grid/Plant-Environment, Atmosphere-Environment, Turbine-Social, and Social-Grid/Plant).

17 WIND ENERGY↗

Water-Fed, Photovoltaic-Driven Anion-Exchange Membrane Water Electrolysis for Solar Hydrogen Production

Direct coupled photovoltaic (PV)-electrolysis is a promising approach for low-cost hydrogen production, avoiding the need for separate electricity generation. Without solar concentration, the operating current densities of a PV-electrolyzer are small, and low capital costs are needed to reach hydrogen production cost targets (<$2/kg). Anion-exchange membrane (AEM) electrolyzers could be well-suited for this application due to their ability to use platinum group metal (PGM)-free catalysts and operate without supporting electrolytes, but a water-fed PV-AEM system has not yet been demonstrated. In this work, the performance of two AEM electrolyzer designs under pure-water, low-temperature, and diurnal-cycling conditions was evaluated. A simple PV-electrolyzer system design with direct electric coupling to a commercial 84 cm2 Si mini module and passive heating and water flow to the electrolyzer was used for on-sun testing in October 2025. The best-performing PV-AEM system achieved an average solar-to-hydrogen (STH) efficiency of 6.6% and a production rate of 15 mg/kWh/m2 of solar irradiance over 11 days. Minimal electrolyzer corrosion was observed, with no loss in efficiency over the diurnal cycles. While highlighting areas for improved electrolyzer and system design, this work is a proof of concept for distributed hydrogen production using inexpensive and abundant materials.

08 HYDROGEN↗

Comprehensive process and environmental impact analysis of integrated DBD plasma steam methane reforming

Utilization of electricity generated from renewable sources to obtain hydrogen, H 2 , is of critical importance to decrease the overall carbon footprint. Here in this work, integration of a dielectric discharge barrier (DBD) plasma reactor to convert low calorific value gas, such as landfill gas or coal mine gas into hydrogen, into the existing steam methane reforming (SMR) technology was evaluated using process design considerations. In particular, a DBD-enhanced catalytic SMR reactor was modeled to operate at near atmospheric pressure and 500 °C sequentially with the conventional reformer to obtain ~ 65 kmol/hr H2 for distributed production. This allowed decreasing the size of the conventional reformer albeit at the increased overall electricity consumption. Calculated process economics showed that only at an electricity cost of less than $0.004/kWh does the hybrid DBD plasma process derived H 2 price become competitive with that of the conventional SMR. A Life Cycle Assessment framework was used to compare environmental impacts from the conventional SMR, hybrid DBD SMR and hybrid DBD SMR utilizing only onshore wind-derived electricity. Larger environmental impacts in the plasma reformer were obtained due to the use of electricity for the plasma reforming operation, which was modeled as coming from the typical U.S. grid mix. Utilizing only 100% wind-derived electricity provided certain environmental benefits, except for the ecotoxicity impact where the wind power scenario modeled here only reduced ecotoxicity impacts associated with electricity by 30%.

08 HYDROGEN↗

Assessing the Impact of the Inflation Reduction Act on Nuclear Plant Power Uprate and Hydrogen Cogeneration

On August 16, 2022, Congress passed the Inflation Reduction Act (IRA) to promote investment in new, carbon-free power generation and sustainable operation of existing carbon-free assets. Specifically, the IRA includes both a production tax credit (PTC – Section 45Y of the IRA) and an investment tax credit (ITC – Section 48E) which utilities may leverage to offset the costs of power uprate. Further, the IRA includes a provision (Section 45V) for a PTC associated with carbon-free hydrogen cogeneration. These tax credits, along with recent legislation efforts to decarbonize the country, have re-emphasized the importance of maintaining and optimizing the existing nuclear plant operating fleet. As a result, utilities are reexamining the possibility of uprating their existing nuclear assets to further maximize carbon-free electricity generation.

08 HYDROGEN↗

Analyzing School Bus Electrification in Richmond, Virginia

School buses are an essential component of the transportation infrastructure, serving as a lifeline for students across the globe. However, the widespread use of diesel school buses has raised concerns about the health impact on millions of students exposed to harmful emissions daily. Recognizing this issue, school districts worldwide are urgently seeking cleaner energy alternatives. Electric school buses emerge as an environmentally friendly and sustainable option, fostering a healthier environment for both students and communities. However, school bus electrification faces the challenges of high upfront cost, cumbersome charging management, and constraints from power grids. To help school bus operators address those challenges, this study presents a data-driven analysis for school bus electrification. This study considered a real-world school bus system in Richmond, VA, and developed a mathematical programming model to analyze the system design, charging strategies, and charging load profiles for the electrification scenario. The study evaluated different charging strategies based on model outcomes, aiming to optimize efficiency and effectiveness. Ultimately, this research generated electric school bus charging demand profiles under various scenarios, shedding light on the feasibility and implications of transitioning to electric-powered school buses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electricity Baseline 2022

The Electricity Baseline (2022) is a regionalized life cycle inventory model of U.S. electricity generation, consumption, and distribution using standardized facility and generation data and was created using the ElectricityLCI v2 Python package (https://github.com/USEPA/ElectricityLCI/tree/v2.0). The Python package used the "ELCI_2022" model configuration to set the facility and generation data sources and years that were used to create this life cycle inventory, which were taken from publicly accessible datasets and automatically curated into a local data store. An archive of the data stores used in this model is available online: https://doi.org/10.18141/2569193. This model is presented in GreenDelta's openLCA schema v2 JSON-LD format (https://greendelta.github.io/olca-schema/).

Electricity; LCA; data inventory↗

Electricity Baseline 2021

The Electricity Baseline (2021) is a regionalized life cycle inventory model of U.S. electricity generation, consumption, and distribution using standardized facility and generation data and was created using the ElectricityLCI v2 Python package (https://github.com/USEPA/ElectricityLCI/tree/v2.0). The Python package used the "ELCI_2021" model configuration to set the facility and generation data sources and years that were used to create this life cycle inventory, which were taken from publicly accessible datasets and automatically curated into a local data store. An archive of the data stores used in this model is available online: https://doi.org/10.18141/2569576. This model is presented in GreenDelta's openLCA schema v2 JSON-LD format (https://greendelta.github.io/olca-schema/).

Electricity; LCA; LCI; Life Cycle↗

Electricity Baseline 2020

The Electricity Baseline (2020) is a regionalized life cycle inventory model of U.S. electricity generation, consumption, and distribution using standardized facility and generation data and was created using the ElectricityLCI v2 Python package (https://github.com/USEPA/ElectricityLCI/tree/v2.0). The Python package used the "ELCI_2020" model configuration to set the facility and generation data sources and years that were used to create this life cycle inventory, which were taken from publicly accessible datasets and automatically curated into a local data store. An archive of the data stores used in this model is available online: https://doi.org/10.18141/2569605. This model is presented in GreenDelta's openLCA schema v2 JSON-LD format (https://greendelta.github.io/olca-schema/).

Electricity; LCA; LCI; data inventory↗

ElectricityLCI

The ElectricityLCI is a Python package for creating regionalized life cycle inventory models of U.S. electricity generation, consumption, and distribution using standardized facility and generation data for use with open-source LCA software.

Electricity; LCA; LCI; Python; life cycle analysis↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

Advanced nuclear reactor integration opportunities for the pulp and paper industry in the U.S. context: Technical perspectives, gap analysis, and preliminary technoeconomic assessment

Pulp and paper (P&P) manufacturing requires a large amount of low-pressure (LP) steam to digest, wash wood fibers and dry pulp into paper. Most of the LP steam is extracted from backpressure turbines that produce power from high-pressure (HP) steam. This HP steam is generated from burning wood waste material; bark is burned in hog boilers, and lignin is boiled in a black liquor recovery boiler. In a typical integrated P&P mill, 50–100% of the steam is produced from these sources, while additional steam is produced in natural gas (NG), fuel oil, or coal boilers. The other energy-intensive process in the plant is the chemical-recovery section (e.g., lime kiln), which requires high-temperature processing from NG combustion to retrieve and recirculate spent chemicals. This paper assesses the energy and heat demand and material balances of a typical generic kraft pulp mill, along with the nuclear heat, steam, and power integration opportunities to replace conventional combustion systems. The paper also addresses steam and electricity generation through a comprehensive technical and engineering gap analysis of five different nuclear-integration opportunities and their process economics, thus enabling the lignin and bark to be further processed into biobased chemicals or fuels, as well as the potential to reduce overall emissions from kraft pulping. Preliminary findings have shown that the P&P industry could achieve technological benefits by integrating their current manufacturing process with small modular nuclear reactors (SMNRs) on a national level. This research aims to set the path forward for a cleaner and more resilient P&P industry.

Advanced nuclear reactor↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Small Nuclear Reactors for Maritime Ports

Maritime ports are entering a period of sharply rising electricity demand as operations are electrified, shore power adoption grows, and energy-intensive industries expand near ports. This report evaluates the feasibility of small nuclear reactors at U.S. ports, which could offer stable baseload power and reduced dependence on regional grids. The report describes the current state of advanced reactor technologies and other factors important for future deployment such as safety and operations, siting requirements, regulatory environments and policy, and other co-benefit considerations. A structured evaluation across a diverse group of U.S. ports highlights the wide variation in feasibility. Fifteen ports were analyzed through port interviews and data collection to assess the port-specific conditions that most impact advanced reactor deployment. The analysis found that the most feasible ports for deployment have favorable geotechnical stability, supportive regulatory environments, and substantial energy loads in a grid-constrained environment. Additionally, an initial reactor size matching was done for the ports based on their reported energy consumption across different modes of operation. However, further analysis and detailed data will be required in the future to determine the optimal reactor-port matching. The economic viability to adopt this technology will be dictated by competitive cost of nuclear-generated electricity compared to other alternatives. Overall, small nuclear reactors present a promising but highly site-dependent pathway for ports seeking resilient, high-capacity energy solutions that support future energy demands. This report identifies key areas for future research and highlights ports that warrant further evaluation to assess the viability of small nuclear reactor implementation. By establishing these priorities, the analysis provides support for the development of informed strategies for potential advanced nuclear technology deployment. The inclusion of ports in this report does not imply their endorsement of nuclear energy generation, and the authors are grateful for the information, expertise, and perspectives they contributed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wind power costs driven by innovation and experience with further reductions on the horizon

The costs of wind power have declined to levels on par with or below those of conventional sources in many parts of the world. Wind power has become one of the fastest-growing sources of new electricity generation. We take stock of wind power cost evolution over the past 20 years, review methodologies commonly used for cost assessment, discuss the potential for continued cost reduction, and identify anticipated cost and value drivers. Our scope includes both onshore and offshore wind technologies. We draw from a vast body of literature on these topics to highlight key trends, approaches, and limitations. Furthermore, we discuss strategies for wind power assets to enhance their marginal economic value to the broader power system and consumers. We identify a myriad of factors that are expected to influence the future cost and value of wind power, including siting, project scale, turbine size, operational synergies, commodity prices, advancements in turbine technologies, enhanced management of the wind resource, and novel control technologies that provide value for the electricity grid. Because the common methods for forecasting future costs each have their own strengths and weaknesses, we find the best insights are elicited from a combination of methods. Overall, researchers and analysts anticipate further sizable cost reductions for onshore and offshore wind. Midrange forecasts for levelized cost of energy in 2050 are generally between $20 and $30/MWh for onshore wind and $40 and $60/MWh for offshore wind, a reduction to approximately half of today's levels. Optimistic forecasts anticipate these levels as early as 2030.

17 WIND ENERGY↗

Opportunities for installed combined heat and power (CHP) to increase grid flexibility in the U.S.

Increasing use of renewable energy requires sufficient grid flexibility to address uncertainty and variability in electricity generation. Previous studies suggest that combined heat and power (CHP) systems may support grid flexibility but they do not consider operating hours. In this paper, we used CHP operating data and determined annual and monthly availability of the installed CHP capacity from various sectors (e.g., utility, independent power producer, commercial, and industrial) in all seven U.S. independent system operators (ISOs) and regional transmission organizations (RTOs). Also, we estimated hourly CHP availability installed in five facility types (i.e., hospitals, universities, hotels, offices, and manufacturing) in the state of New York. The results show that regardless of ISO/RTO, sector, or season, more than 40% of the installed CHP capacity (0.7–8.7 GW) was not fully utilized in 2019; the results are similar for 2018. This available CHP capacity accounted for up to 9% of the ISO/RTO's peak electric demand, which may yield cost savings up to $16 billion by avoiding installation costs of new natural gas combustion or combined-cycle turbines. To exploit the available CHP capacity to enhance grid flexibility, we recommend different policy implications including flexible contract lengths between CHP owners and grid operators, improved market designs, and simplified interconnection standards.

24 POWER TRANSMISSION AND DISTRIBUTION↗