Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Magnetic braking saturates: evidence from the orbital period distribution of low-mass detached eclipsing binaries from ZTF

ABSTRACT We constrain the orbital period (Porb) distribution of low-mass detached main-sequence eclipsing binaries (EBs) with light-curves from the Zwicky Transient Facility (ZTF), which provides a well-understood selection function and sensitivity to faint stars. At short periods (Porb ≲ 2 d), binaries are predicted to evolve significantly due to magnetic braking (MB), which shrinks orbits and ultimately brings detached binaries into contact. The period distribution is thus a sensitive probe of MB. We find that the intrinsic period distribution of low-mass (0.1 ≲ M1/M⊙ < 0.9) binaries is basically flat (${\rm d}N/{\rm d}P_{\rm orb} \propto P_{\rm orb}^0$) from Porb = 10 d down to the contact limit. This is strongly inconsistent with predictions of classical MB models based on the Skumanich relation, which are widely used in binary evolution calculations and predict ${\rm d}N/{\rm d}P_{\rm orb} \propto P_{\rm orb}^{7/3}$ at short periods. The observed distributions are best reproduced by models in which the magnetic field saturates at short periods with a MB torque that scales roughly as $\dot{J}\propto P_{\rm orb}^{-1}$, as opposed to $\dot{J} \propto P_{\rm orb}^{-3}$ in the standard Skumanich law. We also find no significant difference between the period distributions of binaries containing fully and partially convective stars. Our results confirm that a saturated MB law, which was previously found to describe the spin-down of rapidly rotating isolated M dwarfs, also operates in tidally locked binaries. We advocate using saturated MB models in binary evolution calculations. Our work supports previous suggestions that MB in cataclysmic variables (CVs) is much weaker than assumed in the standard evolutionary model, unless mass transfer leads to significant additional angular momentum loss in CVs.

El-Badry, Kareem (ORCID:0000000268711752)↗

Benchmark of the Fe xvv 𝓡 ratio in photoionized plasma during eclipse of Centaurus X-3 with XRISM/Resolve

The $\mathcal {R}$ ratio is a useful diagnostic of the X-ray emitting astrophysical plasmas and is defined as the intensity ratio of the forbidden over the inter-combination lines in the K$\alpha$ line complex of He-like ions. The value is altered by excitation processes (electron impact or UV photoexcitation) from the metastable upper level of the forbidden line, thereby constraining the electron density or UV field intensity. The diagnostic has been applied mostly in electron density constraints in collisionally ionized plasmas using low-Z elements, as was originally proposed for the Sun (Gabriel & Jordan, 1969a, MNRAS, 145, 241), but it can also be used in photoionized plasmas. To make use of this diagnostic, we need to know its value in the limit of no excitation of metastables ($\mathcal {R}_{0}$), which depends on the element, how the plasmas are formed, how the lines are propagated, and the spectral resolution affecting line blending principally with satellite lines from Li-like ions. We benchmark $\mathcal {R}_0$ for photoionized plasmas by comparing calculations using radiative transfer codes and observation data taken with the Resolve X-ray microcalorimeter onboard XRISM. We use the Fe xxv He$\alpha$ line complex of the photo-ionized plasma in Centaurus X-3 observed during eclipse, in which the plasma is expected to be in the limit of no metastable excitation. The measured $\mathcal {R} = 0.65 \pm 0.08$ is consistent with the value calculated using xstar for the plasma parameters derived from other line ratios of the spectrum. We conclude that the $\mathcal {R}$ ratio diagnostic can be used for high-Z elements such as Fe in photoionized plasmas, which has wide applications in plasmas around compact objects at various scales.

X-rays: binaries↗

SU-E-T-641: Development and Verification of Automatic Reading Dose of Interest From Eclipse's DVH

Purpose: According to clinical and research requirement, we develop a function of automatic reading dose of interest from dose volume histogram(DVH), to replace the traditional method with a mouse one by one point, and it's also verified. Methods: The DVH automatic reading function will be developed in an in-house developed radiotherapy information management system(RTIMS), which is based on Apache+PHP+MySQL. A DVH ASCII file is exported from Varian Eclipse V8.6, which includes the following contents: 1. basic information of patient; 2. dose information of plan; 3. dose information of structures, including basic information and dose volume data of target volume and organ at risk. And the default exported dose volume data also includes relative doses by 1% step and corresponding absolute doses and cumulative relative volumes, and the volumes are 4 decimal fraction. Clinically, we often need read the doses of some integer percent volumes, such as D50 and D30. So it couldn't be directly obtained from the above data, but we can use linear interpolation bye the near volumes and doses: Dx=D2−(V2−Vx)*(D2−D1)/(V2−V1), and program a function to search, read and calculate the corresponding data. And the doses of all preseted volume of interest of all structures can be automatically read one by one patient, and saved as a CSV file. To verify it, we select 24 IMRT plans for prostate cancer, and doses of interest are PTV D98/D95/D5/D2, bladder D30/D50, and rectum D25/D50. Two groups of data, using the automatic reading method(ARM) and pointed dose method(PDM), are analyzed with SPSS 16. The absolute difference=D-ARM-D-PDM, relative difference=absolute difference*100%/prescription dose(7600cGy). Results: The differences are as following: PTV D98/D95/D5/D2: −0.04%/− 0.04%/0.13%/0.19%, bladder D30/D50: −0.02%/0.01%, and rectum D25/D50: 0.03%/0.01%. Conclusion: Using this function, the error is very small, and can be neglected. It could greatly improve the efficiency of clinical work. Project supported by the National Natural Science Foundation of China (Grant No.81101694)

60 APPLIED LIFE SCIENCES↗

SU-F-T-138: Commissioning and Evaluating Dose Computation Models for a Dedicated Proton Line Scanning Beam Nozzle in Eclipse Treatment Planning System

Purpose: In this study, we present an effective method to derive low dose envelope of the proton in-air spot fluence at beam positions other than the isocenter to reduce amount of measurements required for planning commission. Also, we demonstrate commissioning and validation results of this method to the Eclipse treatment planning system (version 13.0.29) for a Sumitomo dedicated proton line scanning beam nozzle. Methods: The in-air spot profiles at five beam-axis positions (±200, ±100 and 0 mm) were obtained in trigger mode using a MP3 Water tank (PTW-Freiburg) and a pinpoint ionization chamber (model 31014, PTW-Freiburg). Low dose envelope (below 1% of the center dose) of the spot profile at isocenter was obtained by repeated point measurements to minimize dosimetry uncertainty. The double Gaussian (DG) model was used to fit and obtain optimal σ1, σ2 and their corresponding weightings through our in-house MATLAB (Mathworks) program. σ1, σ2 were assumed to expand linearly along the beam axis from a virtual source position calculated by back projecting fitted sigmas from the single Gaussian (SG) model. Absolute doses in water were validated using an Advanced Markus chamber at the depth of 2cm with Pristine Peak (BP) R90d ranging from 5–32 cm for 10×10 cm2 scanned fields. The field size factors were verified with square fields from 2 to 20 cm at 2cm and before BP depth. Results: The absolute dose outputs were found to be within ±3%. For field size factor, the agreement between calculated and measurement were within ±2% at 2cm and ±3% before BP, except for the field size below 2×2 cm2. Conclusion: The double Gaussian model was found to be sufficient for characterizing the Sumitomo dedicated proton line scanning nozzle. With our effective double Gaussian fitting method, we are able to save significant proton beam time with acceptable output accuracy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-628: An Evaluation of Grid Size in Eclipse AcurosXB Dose Calculation Algorithm for SBRT Lung

Purpose: purpose of this study is to evaluate the effect of grid size in Eclipse AcurosXB dose calculation algorithm for SBRT lung. Methods: Five cases of SBRT lung previously treated have been chosen for present study. Four of the plans were 5 fields conventional IMRT and one was Rapid Arc plan. All five cases have been calculated with five grid sizes (1, 1.5, 2, 2.5 and 3mm) available for AXB algorithm with same plan normalization. Dosimetric indices relevant to SBRT along with MUs and time have been recorded for different grid sizes. The maximum difference was calculated as a percentage of mean of all five values. All the plans were IMRT QAed with portal dosimetry. Results: The maximum difference of MUs was within 2%. The time increased was as high as 7 times from highest 3mm to lowest 1mm grid size. The largest difference of PTV minimum, maximum and mean dose were 7.7%, 1.5% and 1.6% respectively. The highest D2-Max difference was 6.1%. The highest difference in ipsilateral lung mean, V5Gy, V10Gy and V20Gy were 2.6%, 2.4%, 1.9% and 3.8% respectively. The maximum difference of heart, cord and esophagus dose were 6.5%, 7.8% and 4.02% respectively. The IMRT Gamma passing rate at 2%/2mm remains within 1.5% with at least 98% points passing with all grid sizes. Conclusion: This work indicates the lowest grid size of 1mm available in AXB is not necessarily required for accurate dose calculation. The IMRT passing rate was insignificant or not observed with the reduction of grid size less than 2mm. Although the maximum percentage difference of some of the dosimetric indices appear large, most of them are clinically insignificant in absolute dose values. So we conclude that 2mm grid size calculation is best compromise in light of dose calculation accuracy and time it takes to calculate dose.

60 APPLIED LIFE SCIENCES↗

Variability in the Massive Open Cluster NGC 1817 from K2: A Rich Population of Asteroseismic Red Clump, Eclipsing Binary, and Main-sequence Pulsating Stars

We present a survey of variable stars detected in K2 Campaign 13 within the massive intermediate-age (∼1 Gyr) open cluster NGC 1817. We identify a complete sample of 44 red clump stars in the cluster, and have measured asteroseismic quantities (ν {sub max} and/or Δν) for 29 of them. Five stars showed suppressed dipole modes, and the occurrence rates indicate that mode suppression is unaffected by evolution through core helium burning. A subset of the giants in NGC 1817 (and in the similarly aged cluster NGC 6811) have ν {sub max} and Δν values at or near the maximum observed for core helium–burning stars, indicating they have core masses near the minimum for fully nondegenerate helium ignition. Further asteroseismic study of these stars can constrain the minimum helium core mass in red clump stars and the physics that determines this limit. Two giant stars show photometric variations on timescales similar to previously measured spectroscopic orbits. Thirteen systems in the field show eclipses, but only five are probable cluster members. We identify 32 δ Sct pulsators, 27 γ Dor candidates, and 7 hybrids that are probable cluster members, with most being new detections. We used the ensemble properties of the δ Sct stars to identify stars with possible radial pulsation modes. Among the oddities we have uncovered are: an eccentric orbit for a short-period binary containing a δ Sct pulsating star; a rare subgiant within the Hertzsprung gap showing δ Sct pulsations; and two hot γ Dor pulsating star candidates.

79 ASTRONOMY AND ASTROPHYSICS↗