Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

Uselton, Robert B.↗

Evaporator stacks and electronic assemblies

Provided is an evaporator stack. The evaporator stack may be used in power-dense electronic assemblies. The evaporator stack includes a lower floor including at least one mounded portion, and an enclosure surrounding the lower floor, wherein a height of the enclosure is greater than a height of the at least one mounded portion, the at least one mounded portion extending between two walls of the enclosure.

Roan, Thomas J.↗

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]↗

Integrated Evaporator for Efficient Solar-Driven Interfacial Steam Generation

Solar-driven interfacial steam generation is a promising technique for clean water production as it can minimize thermal loss by localizing solar-to-heat conversion at the air/liquid interface. Here we report an integrated solar-evaporator by partially growing two-dimensional polypyrrole microsheets within a melamine foam through chemical vapor polymerization. These microsheets can induce multiple light reflections within the foam, enable omnidirectional light absorption, provide abundant surfaces to promote heat transfer, and achieve spatially-defined hydrophobicity to facilitate vapor escape. Meanwhile, the inherent hydrophilicity of the bottom part of the foam promotes spontaneous upward water transport and suppresses heat loss. The composite foam exhibits an excellent apparent evaporation rate of ~2 kg/(m 2 ·h) and solar-to-vapor efficiency of ~91%. Here, the combined advantages of large surface area, high efficiency, low cost, all weather application, excellent durability, and scalable manufacturing make our integrated design promising for fabricating large-scale solar steam generation systems that are suitable for practical clean water production.

36 MATERIALS SCIENCE↗

Note: A microfluidic freezer based on evaporative cooling of atomized aqueous microdroplets

We report for the first time water-based evaporative cooling integrated into a microfluidic chip for temperature control and freezing of biological solution. We opt for water as a nontoxic, effective refrigerant. Aqueous solutions are atomized in our device and evaporation of microdroplets under vacuum removes heat effectively. We achieve rapid cooling (−5.1 °C/s) and a low freezing temperature (−14.1 °C). Using this approach, we demonstrate freezing of deionized water and protein solution. Our simple, yet effective cooling device may improve many microfluidic applications currently relying on external power-hungry instruments for cooling and freezing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Green Data Center Cooling: Achieving 90% Reduction: Airside Economization and Unique Indirect Evaporative Cooling

The Green Data Center Project was a successful effort to significantly reduce the energy use of the National Snow and Ice Data Center (NSIDC). Through a full retrofit of a traditional air conditioning system, the cooling energy required to meet the data center's constant load has been reduced by over 70% for summer months and over 90% for cooler winter months. This significant change is achievable through the use of airside economization and a new indirect evaporative cooling system. One of the goals of this project was to create awareness of simple and effective energy reduction strategies for data centers. This project's geographic location allowed maximizing the positive effects of airside economization and indirect evaporative cooling, but these strategies may also be relevant for many other sites and data centers in the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acid Evaporation of Ultima Gold™ AB Liquid Scintillation Cocktail Residue

Prior analyses of samples from the F/H Lab solutions showed the presence of diisopropylnapthalene (DIN), a major component of Ultima Gold™ AB liquid scintillation cocktail (LSC). These solutions are processed through H-Canyon Tank 10.5 and ultimately through the 17.8E evaporator. Similar solutions originated in SRNL streams sent to the same H Canyon tanks. This study examined whether the presence of these organics poses a process-significant hazard for the evaporator.

36 MATERIALS SCIENCE↗

Measure Guideline: Evaporative Condensers

The purpose of this measure guideline on evaporative condensers is to provide information on a cost-effective solution for energy and demand savings in homes with cooling loads. This is a prescriptive approach that outlines selection criteria, design and installation procedures, and operation and maintenance best practices. This document has been prepared to provide a process for properlydesigning, installing, and maintaining evaporative condenser systems as well as understanding the benefits, costs, and tradeoffs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Evaporative Condensers

This measure guideline on evaporative condensers provides information on properly designing, installing, and maintaining evaporative condenser systems as well as understanding the benefits, costs, and tradeoffs. This is a prescriptive approach that outlines selection criteria, design and installation procedures, and operation and maintenance best practices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Kolmogorov-Brutsaert structure function model for evaporation into a turbulent atmosphere

In 1965, Brutsaert proposed a model that predicted mean evaporation rate E¯ from rough surfaces to scale with the 3/4 power law of the friction velocity ( u* ) and the square–root of molecular diffusivity (D m ) for water vapor. Furthermore, in arriving at these results, a number of assumptions were made regarding the surface renewal rate describing the contact durations between eddies and the evaporating surface, the diffusional mass process from the surface into eddies, and the cascade of turbulent kinetic energy sustaining the eddy renewal process itself.

54 ENVIRONMENTAL SCIENCES↗

Evaporation-Induced Vertical Alignment Enabling Directional Ion Transport in a 2D-Nanosheet-Based Battery Electrode

2D nanosheets have been widely explored as electrode materials owing to their extraordinarily high electrochemical activity and fast solid-state diffusion. However, the scalable electrode fabrication based on this type of material usually suffers from severe performance losses due to restricted ion-transport kinetics in a large thickness. Here, a novel strategy based on evaporation-induced assembly to enable directional ion transport via forming vertically aligned nanosheets is reported. The orientational ordering is achieved by a rapid evaporation of mixed solvents during the electrode fabrication process. Compared with conventional drop-cast electrodes, which exhibit a random arrangement of the nanosheets and obvious decrease of rate performance with increasing thickness, the electrode based on the vertically aligned nanosheets is able to retain the original high rate capability even at high mass loadings and electrode thickness. Furthermore, combined electrochemical and structural characterization reveals the electrode composed of orientation-controlled nanosheets to possess lower charge-transfer resistances, leading to more complete phase transformation in the active material.

25 ENERGY STORAGE↗

A multiple ion counter total evaporation (MICTE) method for precise analysis of plutonium by thermal ionization mass spectrometry

This study presents a total evaporation method for the analysis of sub-picogram quantities of Pu, utilizing an array of multiple ion counters. Data from three standards are presented to assess the utility of the technique. An external precision of 1.5% RSD (2σ) was achieved on aliquots approaching 100 fg for the minor 240 Pu isotope. Accurate analysis of <1 femtogram of 240 Pu, is achievable, with an external reproducibility of better than 10% RSD (2σ). Finally, this new technique represents a significant advance in the total evaporation method and will allow routine measurement of femtogram sized Pu samples by thermal ionization mass spectrometry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Universal correlation for falling film evaporation heat transfer coefficients of water and seawater

Horizontal falling film evaporators are widely utilized in desalination industries to increase fresh water supply. However, universal correlations for seawater falling film evaporation under varied operational and geometrical conditions are simply unavailable in open literature. Thus, this study aims to develop such a universal correlation for both plain and enhanced tubes. The detailed heat transfer mechanisms are reviewed, and rational parameters are incorporated to develop the universal correlation. A dataset of 994 data points from 9 sources covering a wide range of conditions was compiled. These conditions include Reynolds numbers from 10 to 7235, heat fluxes from 7.7 to 208 kW/m -2 , saturation temperatures from 278 to 401 K, salinities from 0 to 60 gsalt kg -1 water, tube diameters from 15.8 to 50.8 mm, and liquid feeder height to diameter ratios from 1 to 2.25. Upon analysis, it was found that most of the recommended existing correlations exhibited poor predictive accuracy, as evidenced by larger MADs. The developed correlation in this study demonstrated the best predictive accuracy for the entire dataset, yielding a MAD of 16.8 % and an R 2 of 0.82. Furthermore, the performance of the new correlation was individually assessed across a broader spectrum of operational and design conditions, reflecting the individual conditions’ influences with an overall MAD of 20 %.

42 ENGINEERING↗

Effect of MHEC on evaporation and hydration characteristics of glue mortar

The influence of methylhydroxyethylcellulose (MHEC) on both moisture distribution and hydration characteristics of glue mortar using nuclear magnetic resonance imaging (NMR) is investigated. MHEC is added to glue mortar in order to control the drying rate by increasing the open time. Besides drying, MHEC might influence hydration characteristics of mortar. In this study, we therefore examined the effect of MHEC on the hydration characteristics of unsealed mortar. Without MHEC, the evaporation time is faster than hydration time and the water distribution is homogeneous in the mortar, resulting in poor hydration. Addition of MHEC > 1.3 wt.% exhibits an evaporation time comparable to the hydration time of mortar. However, in that case, inhomogeneous distribution of water causes differences in the degree of hydration throughout the mortar sample, i.e. the top surface shows poor hydration and the bottom surface shows good hydration, as confirmed by MIP and T{sub 2} relaxation analysis.

36 MATERIALS SCIENCE↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Triple oxygen isotope compositions of globally distributed soil carbonates record widespread evaporation of soil waters

The stable isotopic composition of pedogenic carbonates is central to many studies of past climate and topography, providing a basis for our understanding of Earth's terrestrial history. A core assumption of many applications of oxygen isotope values (δ 18 O) of pedogenic carbonate is that they reflect the δ 18 O value of precipitation (rain/snow). Here, this assumption is violated if soil carbonates form in evaporated soil waters. In this work, we develop a means to identify evaporation in ancient soils using the triple oxygen isotope composition ( 16 O- 17 O- 18 O) of pedogenic carbonates.

58 GEOSCIENCES↗

Experimental study of plate materials for evaporative air coolers

Following paper presents an experimental study on eight potential plate materials for evaporative air coolers. There are three groups of materials: currently used plate materials (kraft papers), new natural origin plate materials (cotton fibers), and new synthetic plate materials (synthetic fibers). Proposed materials were examined in terms of different properties such as upward and downward distribution height, water capacity, durability and diffusivity. The results were compared with data presented by other authors. It was established that, synthetic materials are characterized by superior water distribution qualities in comparison to the materials of natural origin. Basalt paper-like synthetic fiber allowed to rise water vertically to 40 cm during 120 min tests. The highest water rise obtained in other studies was 18 cm, hence basalt paper-like fiber is visibly superior in comparison with the currently known materials. In terms of downward water distribution, two new synthetic surfactant non-wovens show better performance than the existing materials by quickly and evenly distributing water over the entire length of the sample. The durability of synthetic fibers and non-wovens is higher comparing with the materials of natural origin. The results show that synthetic materials are better suited to the role of plate materials in evaporative air coolers.

Experiment↗

Numerical simulation of evaporating wavy falling liquid films in laminar gas streams

Numerical simulations are performed to investigate the interfacial heat and mass transfer from evaporating wavy falling liquid films in interaction with laminar gas streams. The OpenFOAM solver has been used to conduct the simulations where the liquid-gas interface is resolved using the Volume of Fluid method of solving for three phases, i.e., liquid, vapor, and air. The configuration considered is a falling liquid (water) film on a heated vertical plate with a confined laminar moist air (gas) flow that is either (a) co-current or (b) counter-current to the downward liquid flow. The evaporation at the liquid-gas interface is driven by the interfacial gradient of the vapor mass fraction. Interfacial waves are triggered using a monochromatic forcing disturbance that leads to sinusoidal or solitary waves forming at the liquid-gas interface under respective forcing frequencies. Further, the numerical model is validated with the available experimental data. The results show nearly a 15% enhancement in time-averaged Sherwood number (Sh) due to film waviness (sinusoidal or solitary) at the lower volumetric gas flow rate, Q g = +50 (co-current) and Q g = -50 (counter-current). This enhancement in the Sh for both the waves further increases by 11% with Q g = +800 and 196% with Q g = -800. A closer examination of the mass transfer process over a wave demonstrates that with Q g = +50, the concentration of the gas side streamlines at the trough locations of the wave leads to higher values of Sh at these locations. However, with Q g = +800, although the overall Sh increases, vortices appear at the wave trough locations, leading to a corresponding decrease in the local Sh values. Correlations are proposed for predicting Sh under co-current and counter-current gas flow effects.

36 MATERIALS SCIENCE↗