Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR DETECTING CODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SU-G-JeP1-08: Dual Modality Verification for Respiratory Gating Using New Real- Time Tumor Tracking Radiotherapy System

Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of the lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.

60 APPLIED LIFE SCIENCES↗

Starspot evolution, differential rotation, and magnetic cycles in the chromospherically active binaries lambda andromedae, sigma Geminorum, II Pegasi, and V711 Tauri

We have analyzed 15-19 yr of photoelectric photometry, obtained manually and with automated telescopes, of the chromospherically active binaries lambda And, sigma Gem, II Peg, and V711 Tau. These observations let us identify individual dark starspots on the stellar surfaces from periodic dimming of the starlight, follow the evolution of these spots, and search for long-term cyclic changes in the properties of these starspots that might reveal magnetic cycles analogous to the Sun's 11 yr sunspot cycle. We developed a computer code to fit a simple two-spot model to our observed light curves that allows us to extract the most easily determinable and most reliable spot parameters from the light curves, i.e., spot longitudes and radii. We then used these measured properties to identify individual spots and to chart their life histories by constructing migration and amplitude curves. We identified and followed 11 spots in lambda And, 16 in sigma Gem, 12 in II Peg, and 15 in V711 Tau. Lifetimes of individual spots ranged from a few months to longer than 6 yr. Differential rotation coefficients, estimated from the observed range of spot rotation periods for each star and defined by equation (2), were 0.04 for lambda And, 0.038 for sigma Gem, 0.005 for II Peg, and 0.006 for V711 Tau, versus 0.19 for the Sun. We searched for cyclic changes in mean brightness, B-V color index, and spot rotation period as evidence for long-term cycles. Of these, long-term variability in mean brightness appears to offer the best evidence for such cycles in these four stars. Cycles of 11.1 yr for lambda And, 8.5 yr for sigma Gem, 11 yr for II Peg, and 16 yr V711 Tau are implied by these mean brightness changes. Cyclic changes in spot rotation period were found in lambda And and possibly II Peg. Errors in B-V were too large for any long-term changes to be detectable.

Henry, Gregory W.↗

Measuring the properties of f - mode oscillations of a protoneutron star by third-generation gravitational-wave detectors

Core-collapse supernovae are among the astrophysical sources of gravitational waves that could be detected by third-generation gravitational-wave detectors. Here, we analyze the gravitational-wave strain signals from two- and three-dimensional simulations of core-collapse supernovae generated using the code FORNAX. A subset of the two-dimensional simulations has non-zero core rotation at the core bounce. A dominant source of time changing quadrupole moment is the l = 2 fundamental mode (f- mode) oscillation of the proto-neutron star. From the time-frequency spectrogram of the gravitational-wave strain we see that, starting ~ 400 ms after the core bounce, most of the power lies within a narrow track that represents the frequency evolution of the f-mode oscillations. The f-mode frequencies obtained from linear perturbation analysis of the angle averaged profile of the protoneutron star corroborate what we observe in the spectrograms of the gravitational wave signal. We explore the measurability of the f-mode frequency evolution of protoneutron star for a supernova signal observed in the third-generation gravitational-wave detectors. Measurement of the frequency evolution can reveal information about the masses, radii, and densities of the proto-neutron stars. We find that if the third generation detectors observe a supernova within 10 kpc, we can measure these frequencies to within ~90% accuracy. Here, we can also measure the energy emitted in the fundamental f-mode using the spectrogram data of the strain signal. We find that the energy in the f-mode can be measured to within 20% error for signals observed by Cosmic Explorer using simulations with successful explosion, assuming source distances within 10 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

A Preliminary ZEUS Lightning Location Error Analysis Using a Modified Retrieval Theory

The ZEUS long-range VLF arrival time difference lightning detection network now covers both Europe and Africa, and there are plans for further expansion into the western hemisphere. In order to fully optimize and assess ZEUS lightning location retrieval errors and to determine the best placement of future receivers expected to be added to the network, a software package is being developed jointly between the NASA Marshall Space Flight Center (MSFC) and the University of Nevada Las Vegas (UNLV). The software package, called the ZEUS Error Analysis for Lightning (ZEAL), will be used to obtain global scale lightning location retrieval error maps using both a Monte Carlo approach and chi-squared curvature matrix theory. At the core of ZEAL will be an implementation of an Iterative Oblate (IO) lightning location retrieval method recently developed at MSFC. The IO method will be appropriately modified to account for variable wave propagation speed, and the new retrieval results will be compared with the current ZEUS retrieval algorithm to assess potential improvements. In this preliminary ZEAL work effort, we defined 5000 source locations evenly distributed across the Earth. We then used the existing (as well as potential future ZEUS sites) to simulate arrival time data between source and ZEUS site. A total of 100 sources were considered at each of the 5000 locations, and timing errors were selected from a normal distribution having a mean of 0 seconds and a standard deviation of 20 microseconds. This simulated "noisy" dataset was analyzed using the IO algorithm to estimate source locations. The exact locations were compared with the retrieved locations, and the results are summarized via several color-coded "error maps."

Elander, Valjean↗

Progress in Understanding Error-field Physics in NSTX Spherical Torus Plasmas

The low aspect ratio, low magnetic field, and wide range of plasma beta of NSTX plasmas provide new insight into the origins and effects of magnetic field errors. An extensive array of magnetic sensors has been used to analyze error fields, to measure error field amplification, and to detect resistive wall modes in real time. The measured normalized error-field threshold for the onset of locked modes shows a linear scaling with plasma density, a weak to inverse dependence on toroidal field, and a positive scaling with magnetic shear. These results extrapolate to a favorable error field threshold for ITER. For these low-beta locked-mode plasmas, perturbed equilibrium calculations find that the plasma response must be included to explain the empirically determined optimal correction of NSTX error fields. In high-beta NSTX plasmas exceeding the n=1 no-wall stability limit where the RWM is stabilized by plasma rotation, active suppression of n=1 amplified error fields and the correction of recently discovered intrinsic n=3 error fields have led to sustained high rotation and record durations free of low-frequency core MHD activity. For sustained rotational stabilization of the n=1 RWM, both the rotation threshold and magnitude of the amplification are important. At fixed normalized dissipation, kinetic damping models predict rotation thresholds for RWM stabilization to scale nearly linearly with particle orbit frequency. Studies for NSTX find that orbit frequencies computed in general geometry can deviate significantly from those computed in the high aspect ratio and circular plasma cross-section limit, and these differences can strongly influence the predicted RWM stability. The measured and predicted RWM stability is found to be very sensitive to the E × B rotation profile near the plasma edge, and the measured critical rotation for the RWM is approximately a factor of two higher than predicted by the MARS-F code using the semi-kinetic damping model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced technology for a satellite multichannel demultiplexer/demodulator

Satellite on-board processing is needed to efficiently service multiple users while at the same time minimizing earth station complexity. The processing satellite receives a wideband uplink at 30 GHz and down-converts it to a suitable intermediate frequency. A multichannel demultiplexer then separates the composite signal into discrete channels. Each channel is then demodulated by bulk demodulators, with the baseband signals routed to the downlink processor for retransmission to the receiving earth stations. This type of processing circumvents many of the difficulties associated with traditional bent-pipe repeater satellites. Uplink signal distortion and interference are not retransmitted on the downlink. Downlink power can be allocated in accordance with user needs, independent of uplink transmissions. This allows the uplink users to employ different data rates as well as different modulation and coding schemes. In addition, all downlink users have a common frequency standard and symbol clock on the satellite, which is useful for network synchronization in time division multiple access schemes. The purpose of this program is to demonstrate the concept of an optically implemented multichannel demultiplexer (MCD). A proof-of-concept (POC) model has been developed which has the ability to receive a 40 MHz wide composite signal consisting of up to 1000 40 kHz QPSK modulated channels and perform the demultiplexing process. In addition a set of special test equipment (STE) has been configured to evaluate the performance of the POC model. The optical MCD is realized as an acousto-optic spectrum analyzer utilizing the capability of Bragg cells to perform the required channelization. These Bragg cells receive an optical input from a laser source and an RF input (the signal). The Bragg interaction causes optical output diffractions at angles proportional to the RF input frequency. These discrete diffractions are optically detected and output to individual demodulators for baseband conversion. Optimization of the MCD design was conducted in order to achieve a compromise between two opposing sources of signal degradation: adjacent channel interference and intersymbol interference. The system was also optimized to allow simple, inexpensive ground stations communications with the MCD. These design goals led to the realization of a POC MCD which demonstrates the demultiplexing function with minimal signal degradation. Performance evaluation results using the STE equipment indicate that the dynamic range of the demultiplexer in the presence of adjacent and multiple channel loading is 40 - 50 dB. Measured bit error rate (BER) probabilities varied from the predicted theoretical results by one dB or less. The performance of the proof-of-concept model indicate that the development of a space qualified optically implemented MCD are feasible. The advantages to such an implementation include reduced size, weight and power and increased reliability when compared with electronic approaches. All of these factors are critical to on-board satellite processors. Further optimization can be conducted which trade ground station complexity and MCD performance to achieve desired system results.

Abramovitz, Irwin J.↗

Quantitative Methods for Comparing Different Polyline Stream Network Models

Two techniques for exploring relative horizontal accuracy of complex linear spatial features are described and sample source code (pseudo code) is presented for this purpose. The first technique, relative sinuosity, is presented as a measure of the complexity or detail of a polyline network in comparison to a reference network. We term the second technique longitudinal root mean squared error (LRMSE) and present it as a means for quantitatively assessing the horizontal variance between two polyline data sets representing digitized (reference) and derived stream and river networks. Both relative sinuosity and LRMSE are shown to be suitable measures of horizontal stream network accuracy for assessing quality and variation in linear features. Both techniques have been used in two recent investigations involving extracting of hydrographic features from LiDAR elevation data. One confirmed that, with the greatly increased resolution of LiDAR data, smaller cell sizes yielded better stream network delineations, based on sinuosity and LRMSE, when using LiDAR-derived DEMs. The other demonstrated a new method of delineating stream channels directly from LiDAR point clouds, without the intermediate step of deriving a DEM, showing that the direct delineation from LiDAR point clouds yielded an excellent and much better match, as indicated by the LRMSE.

58 GEOSCIENCES↗

Progress in understanding error-field physics in NSTX spherical torus plasmas

The low-aspect ratio, low magnetic field and wide range of plasma beta of NSTX plasmas provide new insight into the origins and effects of magnetic field errors. An extensive array of magnetic sensors has been used to analyse error fields, to measure error-field amplification and to detect resistive wall modes (RWMs) in real time. The measured normalized error-field threshold for the onset of locked modes shows a linear scaling with plasma density, a weak to inverse dependence on toroidal field and a positive scaling with magnetic shear. These results extrapolate to a favourable error-field threshold for ITER. For these low-beta locked-mode plasmas, perturbed equilibrium calculations find that the plasma response must be included to explain the empirically determined optimal correction of NSTX error fields. In high-beta NSTX plasmas exceeding the n = 1 no-wall stability limit where the RWM is stabilized by plasma rotation, active suppression of n = 1 amplified error fields and the correction of recently discovered intrinsic n = 3 error fields have led to sustained high rotation and record durations free of low-frequency core MHD activity. For sustained rotational stabilization of the n = 1 RWM, both the rotation threshold and the magnitude of the amplification are important. At fixed normalized dissipation, kinetic damping models predict rotation thresholds for RWM stabilization to scale nearly linearly with particle orbit frequency. Studies for NSTX find that orbit frequencies computed in general geometry can deviate significantly from those computed in the high-aspect ratio and circular plasma cross-section limit, and these differences can strongly influence the predicted RWM stability. The measured and predicted RWM stability is found to be very sensitive to the E x B rotation profile near the plasma edge, and the measured critical rotation for the RWM is approximately a factor of two higher than predicted by the MARS-F code using the semi-kinetic damping model.

Menard, J↗

Planetary Aeronomy and Related Studies

Mercury atmosphere - Sprague and Hunten, in collaboration with Katharina Lodders of Washington University, proposed, mainly on cosmochemical grounds, that S atoms are an important constituent of the atmosphere (30 times more abundant than sodium). This paper has appeared in Icarus. We also suggest that condensed sulfur is an excellent candidate for the radar-bright polar caps, more plausible than water ice because the latter is only barely stable even in permanently-shadowed craters. The best prospect for detection of the vapor is through its resonance lines, a triplet near 1814 A. Mercury is too close to the Sun to be observed by any existing space telescope, but there is some prospect that the search could be made from a Shuttle-based spectrograph such as Lyle Broadfoot's USTAR. Sprague and Hunten have completed an elaborate data analysis of over 100 measurements of the Na D lines, obtained with the 61-inch telescope and our echelle spectrograph. Full account has been taken of the radiative-transfer problem that arises because the Na atmosphere is not optically thin. The output of this code is used in another program that makes an elaborate inverse interpolation in two angles and optical depth and computes the effect of the seeing (always bad for Mercury). The seeing is determined by fitting cuts across a computed image to part of the spectrum adjacent to the sodium lines, and typically ranges from slightly less than 4 arcsec to worse than 6 (diameter at l/e of a Gaussian). The final result is a list of Na abundances, with some information on spatial distribution. One particularly interesting result of further analysis is a strong abundance maximum in the morning relative to the afternoon, confirming an earlier result for potassium, based on much fewer measurements. The analysis are completed during the extension of the present grant. This work depends heavily on the Hapke parameters used to estimate the reflectance of Mercury's surface. The paper by Domingue et al. examines the credibility of the available parameters, which are derived from disk-unresolved photometry, and concludes that errors in the derived Na abundances could be as great as 30%.

Hunten, D. M.↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

Identifying Sociomarkers of Pediatric Asthma Patients at Risk of Hospital Revisiting

ObjectiveAsthma is one of the most common chronic childhood diseases in the United States [2, 3]. In addition to its pervasiveness, pediatric asthma shows high sensitivity to the environment. Combining medical-social dataset with machine learning methods we demonstrate how socio-markers play an important role in identifying patients at risk of hospital revisits due to pediatric asthma within a year.IntroductionA socio-marker is a measurable indicator of social conditions where a patient is embedded in and exposed to, being analogous with a biomarker indicating the severity or presence of some disease state. Social factors are one of the most clinical health determinants [1], which play a critical role in explaining health outcomes. Socio-markers can help medical practitioners and researchers to reliably identify high-risk individuals in a timely manner.MethodsWe collected data from three different sources: pediatric asthma encounter records from Jan 1st, 2016 to Dec 31st, 2016 at a children’s hospital, the 2010 U.S census data and neighborhood quality survey data by Memphis Property Hub. After merging these datasets we examine the effect of social features in identifying the patients who visited the hospital more than once during the observation period. We only use the first time visit (3,678 cases) to avoid over-counting of the same patients. In addition to demographic features (age, gender, insurance type, and race (African American and White)), we incorporate the social features such as the proportion of individuals living below the federal poverty level, blight prevalence, neighborhood quality, neighborhood quality inequality, trash dumping presence, the broken window pervasiveness within the zip code area of patients’ residence are included.We then implemented a Support Vector Machine (SVM) based classification model using abovementioned 11 social features. The classification outcome is either patient visits the hospital only one-time (class 0) or revisits the hospital within a year (class 1). Among 3,678 unique patients in the dataset, only 823 pediatric patients revisited hospital with asthma. So, to overcome the class imbalance issue, we have used 823 patients’ data (randomly selected in 1,000 iterations) from each class. Further, to avoid overfitting and ensure generalizability, we divided the dataset as training, test, and validation with a proportion of 60%, 20%, and 20%, respectively. The reported test (5-folds cross-validation using training and testing data) and validation accuracy of the SVM method are averaged over 1,000 iterations to avoid sampling error and bias.ResultsThe proposed socio-marker model resulted in an average classification accuracy of 63.70% for the test set and 63.67 % for the validation set. Further, the average specificity (the total true negative cases divided by the sum of true negative and false positive) and sensitivity (the total number of true positive cases divided by the sum of positive predicted cases) is found to be 62.79% and 64.77%, respectively for the test set and 62.79% and 64.83%, respectively for the validation set. Results of this study suggest that socio-marker features that are not directly related to a patient’s medical conditions can still predict whether the patient will come back to the hospital within a year or not with approximately 64% accuracy.ConclusionsBringing the socio-marker features in the surveillance system may ease the burden of detecting the patients at risk of revisiting the hospital. The results should be interpreted with caution because we only used 12-month period of observation and the visit beyond the observation window is not considered. Also the patients may have visited different hospitals which are not captured in the data.References1. Booske BC, Athens JK, Kindig DA, Park H, Remington PL: Different perspectives for assigning weights to determinants of health. University of Wisconsin: Population Health Institute 2010.2. Subbarao P, Mandhane PJ, Sears MR: Asthma: epidemiology, etiology and risk factors. Canadian Medical Association Journal 2009, 181(9):E181-E190.3. Gold DR, Wright R: Population disparities in asthma. Annu Rev Public Health 2005, 26:89-113.

Shin, Eun Kyong↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗

Phase-curve Pollution of Exoplanet Transmission Spectra

The occurrence of a planet transiting in front of its host star offers the opportunity to observe the planet’s atmosphere filtering starlight. The fraction of occulted stellar flux is roughly proportional to the optically thick area of the planet, the extent of which depends on the opacity of the planet’s gaseous envelope at the observed wavelengths. Chemical species, haze, and clouds are now routinely detected in exoplanet atmospheres through rather small features in transmission spectra, i.e., collections of planet-to-star area ratios across multiple spectral bins and/or photometric bands. Technological advances have led to a shrinking of the error bars down to a few tens of parts per million (ppm) per spectral point for the brightest targets. The upcoming James Webb Space Telescope (JWST) is anticipated to deliver transmission spectra with precision down to 10 ppm. The increasing precision of measurements requires a reassessment of the approximations hitherto adopted in astrophysical models, including transit light-curve models. Recently, it has been shown that neglecting the planet’s thermal emission can introduce significant biases in the transit depth measured with the JWST/Mid-InfraRed Instrument, integrated between 5 and 12 μm. In this paper, we take a step forward by analyzing the effects of the approximation on transmission spectra over the 0.6–12 μm wavelength range covered by various JWST instruments. We present open-source software to predict the spectral bias, showing that, if not corrected, it may affect the inferred molecular abundances and thermal structure of some exoplanet atmospheres.

47 OTHER INSTRUMENTATION↗

Toward Synthesis, Analysis, and Certification of Security Protocols

Implemented security protocols are basically pieces of software which are used to (a) authenticate the other communication partners, (b) establish a secure communication channel between them (using insecure communication media), and (c) transfer data between the communication partners in such a way that these data only available to the desired receiver, but not to anyone else. Such an implementation usually consists of the following components: the protocol-engine, which controls in which sequence the messages of the protocol are sent over the network, and which controls the assembly/disassembly and processing (e.g., decryption) of the data. the cryptographic routines to actually encrypt or decrypt the data (using given keys), and t,he interface to the operating system and to the application. For a correct working of such a security protocol, all of these components must work flawlessly. Many formal-methods based techniques for the analysis of a security protocols have been developed. They range from using specific logics (e.g.: BAN-logic [4], or higher order logics [12] to model checking [2] approaches. In each approach, the analysis tries to prove that no (or at least not a modeled intruder) can get access to secret data. Otherwise, a scenario illustrating the &tack may be produced. Despite the seeming simplicity of security protocols ("only" a few messages are sent between the protocol partners in order to ensure a secure communication), many flaws have been detected. Unfortunately, even a perfect protocol engine does not guarantee flawless working of a security protocol, as incidents show. Many break-ins and security vulnerabilities are caused by exploiting errors in the implementation of the protocol engine or the underlying operating system. Attacks using buffer-overflows are a very common class of such attacks. Errors in the implementation of exception or error handling can open up additional vulnerabilities. For example, on a website with a log-in screen: multiple tries with invalid passwords caused the expected error message (too many retries). but let the user nevertheless pass. Finally, security can be compromised by silly implementation bugs or design decisions. In a commercial VPN software, all calls to the encryption routines were incidentally replaced by stubs, probably during factory testing. The product worked nicely. and the error (an open VPN) would have gone undetected, if a team member had not inspected the low-level traffic out of curiosity. Also, the use secret proprietary encryption routines can backfire, because such algorithms often exhibit weaknesses which can be exploited easily (see e.g., DVD encoding). Summarizing, there is large number of possibilities to make errors which can compromise the security of a protocol. In today s world with short time-to-market and the use of security protocols in open and hostile networks for safety-critical applications (e.g., power or air-traffic control), such slips could lead to catastrophic situations. Thus, formal methods and automatic reasoning techniques should not be used just for the formal proof of absence of an attack, but they ought to be used to provide an end-to-end tool-supported framework for security software. With such an approach all required artifacts (code, documentation, test cases) , formal analyses, and reliable certification will be generated automatically, given a single, high level specification. By a combination of program synthesis, formal protocol analysis, certification; and proof-carrying code, this goal is within practical reach, since all the important technologies for such an approach actually exist and only need to be assembled in the right way.

Schumann, Johann↗

SU-G-TeP4-08: Automating the Verification of Patient Treatment Parameters

Purpose: To automate the daily verification of each patient’s treatment by utilizing the trajectory log files (TLs) written by the Varian TrueBeam linear accelerator while reducing the number of false positives including jaw and gantry positioning errors, that are displayed in the Treatment History tab of Varian’s Chart QA module. Methods: Small deviations in treatment parameters are difficult to detect in weekly chart checks, but may be significant in reducing delivery errors, and would be critical if detected daily. Software was developed in house to read TLs. Multiple functions were implemented within the software that allow it to operate via a GUI to analyze TLs, or as a script to run on a regular basis. In order to determine tolerance levels for the scripted analysis, 15,241 TLs from seven TrueBeams were analyzed. The maximum error of each axis for each TL was written to a CSV file and statistically analyzed to determine the tolerance for each axis accessible in the TLs to flag for manual review. The software/scripts developed were tested by varying the tolerance values to ensure veracity. After tolerances were determined, multiple weeks of manual chart checks were performed simultaneously with the automated analysis to ensure validity. Results: The tolerance values for the major axis were determined to be, 0.025 degrees for the collimator, 1.0 degree for the gantry, 0.002cm for the y-jaws, 0.01cm for the x-jaws, and 0.5MU for the MU. The automated verification of treatment parameters has been in clinical use for 4 months. During that time, no errors in machine delivery of the patient treatments were found. Conclusion: The process detailed here is a viable and effective alternative to manually checking treatment parameters during weekly chart checks.

60 APPLIED LIFE SCIENCES↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, June 2014

Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

Source record↗

TU-AB-202-06: Quantitative Evaluation of Deformable Image Registration in MRI-Guided Adaptive Radiation Therapy

Purpose: To assess the performance of the deformable image registration algorithm used for MRI-guided adaptive radiation therapy using image feature analysis. Methods: MR images were collected from five patients treated on the MRIdian (ViewRay, Inc., Oakwood Village, OH), a three head Cobalt-60 therapy machine with an 0.35 T MR system. The images were acquired immediately prior to treatment with a uniform 1.5 mm resolution. Treatment sites were as follows: head/neck, lung, breast, stomach, and bladder. Deformable image registration was performed using the ViewRay software between the first fraction MRI and the final fraction MRI, and the DICE similarity coefficient (DSC) for the skin contours was reported. The SIFT and Harris feature detection and matching algorithms identified point features in each image separately, then found matching features in the other image. The target registration error (TRE) was defined as the vector distance between matched features on the two image sets. Each deformation was evaluated based on comparison of average TRE and DSC. Results: Image feature analysis produced between 2000–9500 points for evaluation on the patient images. The average (± standard deviation) TRE for all patients was 3.3 mm (±3.1 mm), and the passing rate of TRE<3 mm was 60% on the images. The head/neck patient had the best average TRE (1.9 mm±2.3 mm) and the best passing rate (80%). The lung patient had the worst average TRE (4.8 mm±3.3 mm) and the worst passing rate (37.2%). DSC was not significantly correlated with either TRE (p=0.63) or passing rate (p=0.55). Conclusions: Feature matching provides a quantitative assessment of deformable image registration, with a large number of data points for analysis. The TRE of matched features can be used to evaluate the registration of many objects throughout the volume, whereas DSC mainly provides a measure of gross overlap. We have a research agreement with ViewRay Inc.

60 APPLIED LIFE SCIENCES↗