Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic

Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron acceleration during the decay of nonlinear Whistler waves in low-beta electron-ion plasma

Relativistic electron acceleration through dissipation of a nonlinear, short-wavelength, and monochromatic electromagnetic whistler wave in low-beta plasma is investigated by utilizing a one-dimensional fully relativistic electromagnetic particle-in-cell code. The nonlinear (large-amplitude) parent whistler wave decays through the parametric instability which enhances electrostatic ion acoustic waves and electromagnetic whistler waves. These waves satisfy the condition of three-wave coupling. Through the decay instability, the energy of electron bulk velocity supporting the parent wave is converted to the thermal energy perpendicular to the background magnetic field. Increase of the perpendicular temperature triggers the electron temperature anisotropy instability which generates broadband whistler waves and heats electrons in the parallel direction. The broadband whistler waves are inverse-cascaded during the relaxation of the electron temperature anisotropy. In lower-beta conditions, electrons with a pitch angle of about 90° are successively accelerated by inverse-cascaded whistler waves, and selected electrons are accelerated to over a Lorentz factor of 10. The result implies that the nonlinear dissipation of a finite-amplitude and short-wavelength whistler wave plays an important role in producing relativistic nonthermal electrons over a few MeV especially at lower beta plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron energy partition in the ‘above-the-looptop’ solar hard X-ray sources

The presentation begins by considering the non-thermal fraction of electron energies (R ε ) in 'above-the-looptop' (ALT). Several spectral models area considered: isothermal model, power-law, and the newly derived kappa distribution. Technically, all 3 non-thermal models can fit the data. In the discussion of flare scenario, energy partition, energization mechanism, and collisionality are considered. It is concluded that the kappa distribution works (R ε ≲ 50%), magnetic reconnection scenario works, and Coulomb collisions may reduce the non-thermal fraction of electron energies.

79 ASTRONOMY AND ASTROPHYSICS↗

Anticathode effect on electron kinetics in electron beam generated E × B plasma

Electron beam (e-beam) generated plasmas with applied crossed electric and magnetic (E x B) fields are promising for low damage processing of materials with applications to microelectronics and quantum information systems. In cylindrical e-beam E x B plasmas, radial confinement of electrons and ions is achieved by an axial magnetic field and radial electric field, respectively. To control the axial confinement of electrons, such e-beam generated plasma sources may incorporate a conducting boundary known as an anticathode, which is placed on the axially opposite side of the plasma from the cathode. In this work, it is shown that varying the anticathode voltage bias can control the degree to which the anticathode collects or repels incident electrons, allowing control of warm electron (electron energies in 10–30 eV range) and beam electron population confinement. It is suggested that the effect of the anticathode bias on the formation of these distinct electron populations is also associated with the transition between weak turbulence and strong Langmuir turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-differential and integral cross sections for electron-impact ionization for the damage of carbon clusters irradiated with x-ray free-electron lasers

Single-differential and integral cross sections for electron-impact ionization of the C atom and its ions were calculated with the binary-encounter-dipole model [Y.-K. Kim and M. E. Rudd, Phys. Rev. A 50, 3954 (1994)] to study the distribution of free-electron energies in carbon clusters after being irradiated with an x-ray free-electron laser (XFEL). The averaged energies of the secondary electrons for the C atom, and C{sup 1+}, C{sup 2+}, and C{sup 3+} ions were about 20, 70, 160, and 200 eV, respectively, when incident electron energy was about 20 keV, while those energies were in the order of tens of electronvolts when the incident electron energy was about 250 eV. The damage to carbon clusters irradiated with the XFEL was also investigated with time-dependent rate equations, considering photoionization, Compton scattering, Auger decay, and electron-impact ionization of the C atom and its ions. The results show that the electron-impact ionization becomes a more important process as the x-ray flux decreases, while the effect of Auger decay gradually appears as the x-ray flux increases. The energy dependence of the incident x ray was also investigated to evaluate the resolution of the diffraction pattern. These results indicate that we should make the XFEL pulse a few fs and about 16 keV to suppress damage and obtain desired resolution of the diffraction pattern.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rapid chain tracing of polypeptide backbones in electron-density maps

A method for rapid chain tracing of polypeptide backbones at moderate resolution is presented. A method for the rapid tracing of polypeptide backbones has been developed. The method creates an approximate chain tracing that is useful for visual evaluation of whether a structure has been solved and for use in scoring the quality of electron-density maps. The essence of the method is to (i) sample candidate C{sup α} positions at spacings of approximately 0.6 Å along ridgelines of high electron density, (ii) list all possible nonapeptides that satisfy simple geometric and density criteria using these candidate C{sup α} positions, (iii) score the nonapeptides and choose the highest scoring ones, and (iv) find the longest chains that can be made by connecting nonamers. An indexing and storage scheme that allows a single calculation of most distances and density values is used to speed up the process. The method was applied to 42 density-modified electron-density maps at resolutions from 1.5 to 3.8 Å. A total of 21 428 residues in these maps were traced in 24 CPU min with an overall r.m.s.d. of 1.61 Å for C{sup α} atoms compared with the known refined structures. The method appears to be suitable for rapid evaluation of electron-density map quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Spin-Light Polarimeter for Multi-GeV Longitudinally Polarized Electron Beams

The physics program at the upgraded Jefferson Lab (JLab) and the physics program envisioned for the proposed electron-ion collider (EIC) include large efforts to search for interactions beyond the Standard Model (SM) using parity violation in electroweak interactions. These experiments need precision electron polarimetry with an uncertainty of <; 0.5 %. The spin dependent Synchrotron radiation, called "spin-light," can be used to monitor the electron beam polarization. Here, we develop a conceptual design for a "spin-light" polarimeter that can be used at a high intensity, multi-GeV electron accelerator. We have also built a Geant4 based simulation for a prototype device and report some of the results from these simulations

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods for measurement of electron emission yield under low energy electron-irradiation by collector method and Kelvin probe method

Secondary electron emission yield of gold under electron impact at normal incidence below 50 eV was investigated by the classical collector method and by the Kelvin probe method. The authors show that biasing a collector to ensure secondary electron collection while keeping the target grounded can lead to primary electron beam perturbations. Thus reliable secondary electron emission yield at low primary electron energy cannot be obtained with a biased collector. The authors present two collector-free methods based on current measurement and on electron pulse surface potential buildup (Kelvin probe method). These methods are consistent, but at very low energy, measurements become sensitive to the earth magnetic field (below 10 eV). For gold, the authors can extrapolate total emission yield at 0 eV to 0.5, while a total electron emission yield of 1 is obtained at 40{+-}1 eV.

36 MATERIALS SCIENCE↗

Electron Transitions during the Capture of an Electron by a He{sup 2+} Ion at the Argon Atom

We have measured the absolute values of the total cross section of the one-electron capture by He{sup 2+} ions in the kinetic energy range 2–30 keV at the Ar atoms. The absolute values of the differential scattering cross sections of He{sup +} ions formed during the one-electron capture and the electron capture with ionization at energies of 2.2, 5.4, and 30 keV have been determined. The electronic states of the formed ions have been determined using collision spectroscopy based on analysis of the change in the kinetic energy of He{sup +} after the interaction. We have measured doubly differential (with respect to the kinetic energy and the scattering angle) cross sections of the formation of free electrons. The free electron formation channels (direct ionization and electron capture with ionization) have been analyzed by calculating the electron terms of the (HeAr){sup 2+} system. The calculated cross section of capture with ionization is in conformity with the cross section measured using collision spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

MIXING THE SOLAR WIND PROTON AND ELECTRON SCALES: EFFECTS OF ELECTRON TEMPERATURE ANISOTROPY ON THE OBLIQUE PROTON FIREHOSE INSTABILITY

The double adiabatic expansion of the nearly collisionless solar wind plasma creates conditions for the firehose instability to develop and efficiently prevent the further increase of the plasma temperature in the direction parallel to the interplanetary magnetic field. The conditions imposed by the firehose instability have been extensively studied using idealized approaches that ignore the mutual effects of electrons and protons. Recently, more realistic approaches have been proposed that take into account the interplay between electrons and protons, unveiling new regimes of the parallel oscillatory modes. However, for oblique wave propagation the instability develops distinct branches that grow much faster and may therefore be more efficient than the parallel firehose instability in constraining the temperature anisotropy of the plasma particles. This paper reports for the first time on the effects of electron plasma properties on the oblique proton firehose (PFH) instability and provides a comprehensive vision of the entire unstable wave-vector spectrum, unifying the proton and the smaller electron scales. The plasma β and temperature anisotropy regimes considered here are specific for the solar wind and magnetospheric conditions, and enable the electrons and protons to interact via the excited electromagnetic fluctuations. For the selected parameters, simultaneous electron and PFH instabilities can be observed with a dispersion spectrum of the electron firehose (EFH) extending toward the proton scales. Growth rates of the PFH instability are markedly boosted by the anisotropic electrons, especially in the oblique direction where the EFH growth rates are orders of magnitude higher.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasi-two-dimensional electron gas at the epitaxial alumina/SrTiO{sub 3} interface: Control of oxygen vacancies

In this paper, we report on the highly conductive layer formed at the crystalline γ-alumina/SrTiO{sub 3} interface, which is attributed to oxygen vacancies. We describe the structure of thin γ-alumina layers deposited by molecular beam epitaxy on SrTiO{sub 3} (001) at growth temperatures in the range of 400–800 °C, as determined by reflection-high-energy electron diffraction, x-ray diffraction, and high-resolution electron microscopy. In situ x-ray photoelectron spectroscopy was used to confirm the presence of the oxygen-deficient layer. Electrical characterization indicates sheet carrier densities of ∼10{sup 13 }cm{sup −2} at room temperature for the sample deposited at 700 °C, with a maximum electron Hall mobility of 3100 cm{sup 2}V{sup −1}s{sup −1} at 3.2 K and room temperature mobility of 22 cm{sup 2}V{sup −1}s{sup −1}. Annealing in oxygen is found to reduce the carrier density and turn a conductive sample into an insulator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A split-step method to include electron–electron collisions via Monte Carlo in multiple rate equation simulations

A split-step numerical method for calculating ultrafast free-electron dynamics in dielectrics is introduced. The two split steps, independently programmed in C++11 and FORTRAN 2003, are interfaced via the presented open source wrapper. The first step solves a deterministic extended multi-rate equation for the ionization, electron–phonon collisions, and single photon absorption by free-carriers. The second step is stochastic and models electron–electron collisions using Monte-Carlo techniques. This combination of deterministic and stochastic approaches is a unique and efficient method of calculating the nonlinear dynamics of 3D materials exposed to high intensity ultrashort pulses. Results from simulations solving the proposed model demonstrate how electron–electron scattering relaxes the non-equilibrium electron distribution on the femtosecond time scale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous Wave Resonant Photon Stimulated Electron Energy-Gain and Electron Energy-Loss Spectroscopy of Individual Plasmonic Nanoparticles

The unique optical properties of surface plasmon resonances in nanostructured materials have attracted considerable attention, broadly impacting both fundamental research and applied technologies ranging from sensing and optoelectronics to quantum computing. Electron energy-loss spectroscopy (EELS) in the transmission electron microscope has revealed valuable information about the full plasmonic spectrum of these materials with nanoscale spatial resolution. Here, in this study, we report a novel approach for experimentally accessing the photon-stimulated electron energy-gain and stimulated electron energy-loss responses of individual plasmonic nanoparticles via the simultaneous irradiation of a continuous wave laser and continuous current, monochromated electron probe. Stimulated gain and loss probabilities are equivalent and increase linearly in the low-irradiance range of 0.5 × 10 8 to 4 × 10 8 W/m 2 , above which excessive heating reduces the observed probabilities; importantly in our low-irradiance regime, the photon energy must be tuned in resonance with the plasmon energy for the stimulated gain and loss peaks to emerge. Theoretical modeling based on Fermi’s golden rule elucidates how the plasmon resonantly and coherently shuttles energy quanta between the electron probe and the radiation field and vice versa in stimulated electron energy-loss and -gain events. This study opens a fundamentally new approach to explore the quantum physics of excited-state plasmon resonances that does not rely on high-intensity laser pulses or any modification to the EELS detector.

(scanning) transmission electron microscope ((S)TE↗

Collision Processes of Highly Charged Ions with Electrons Studied with an Electron Beam Ion Trap

The electron beam ion trap in Tokyo (Tokyo-EBIT)is suitable for studying relativistic effects in the collisions of highly charged heavy ions with electrons because it can produce and trap very highly charged heavy ions which interact with a mono-energetic and unidirectional relativistic electron beam with an energy of up to 200 keV. Recently, we have been studying resonant processes in ionization and recombination by measuring the charge abundance inside the EBIT at the equilibrium. The abundance ratio between adjacent charge states varies slowly with the electron energy when there is no resonant process. However, when the electron energy coincides with the resonant energy at which ionization or recombination is enhanced, the abundance ratio can drastically change. Thus, the resonant processes can be studied by measuring the abundance ratio between adjacent ions as a function of electron beam energy. In this talk, recent progress for heavy ions with very high charge states up to He-like Bi{sup 81+}, is presented. For such ions, relativistic effects significantly affect the resonant processes. For example, the generalized Breit interaction (GBI) effect, which treats the retardation in the exchange of single virtual photon between the free and orbital electrons, has been clearly observed in the DR resonant strength in Li-like Bi{sup 80+}. Recently we have also found that the GBI effect plays an important role in the interference between non-resonant and resonant recombinations. Experimental results are presented in comparison with theoretical calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 Division-Sign 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 Division-Sign 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic-Resolution Imaging with a Sub-50-pm Electron Probe

Using a highly coherent focused electron probe in a fifth-order aberration-corrected transmission electron microscope, we report on resolving a crystal spacing less than 50 pm. Based on the geometrical source size and residual coherent and incoherent axial lens aberrations, an electron probe is calculated, which is theoretically capable of resolving an ideal 47 pm spacing with 29% contrast. Our experimental data show the 47 pm spacing of a Ge <114> crystal imaged with 11%-18% contrast at a 60%-95% confidence level, providing the first direct evidence for sub-50-pm resolution in annular dark-field scanning transmission electron microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Gaussian electron guns for RHIC electron lens

Simulations of two versions of the electron gun for RHIC electron lens are presented. The electron guns have to generate an electron beam with Gaussian radial profile of the electron beam density. To achieve the Gaussian electron emission profile on the cathode we used a combination of the gun electrodes and shaping of the cathode surface. Dependence of electron gun performance parameters on the geometry of electrodes and the margins for electrodes positioning are presented.

43 PARTICLE ACCELERATORS↗