Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Demand response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Paying for demand-side response at the wholesale level

The recent FERC Notice of Public Rulemaking regarding the payment to demand-side resources in wholesale markets has engendered a great deal of comments including FERC's obligation to ensure just and reasonable rates in the wholesale market and criteria for what FERC should do (on grounds of economic efficiency) without any real focus on what that commitment would really mean if FERC actually pursued it. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilization of Heat Pump Water Heaters for Load Management

The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

Boudreaux, Philip R↗

Statistical Analysis of Baseline Load Models for Non-Residential Buildings

Policymakers are encouraging the development of standardized and consistent methods to quantify the electric load impacts of demand response programs. For load impacts, an essential part of the analysis is the estimation of the baseline load profile. In this paper, we present a statistical evaluation of the performance of several different models used to calculate baselines for commercial buildings participating in a demand response program in California. In our approach, we use the model to estimate baseline loads for a large set of proxy event days for which the actual load data are also available. Measures of the accuracy and bias of different models, the importance of weather effects, and the effect of applying morning adjustment factors (which use data from the day of the event to adjust the estimated baseline) are presented. Our results suggest that (1) the accuracy of baseline load models can be improved substantially by applying a morning adjustment, (2) the characterization of building loads by variability and weather sensitivity is a useful indicator of which types of baseline models will perform well, and (3) models that incorporate temperature either improve the accuracy of the model fit or do not change it.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven key performance indicators and datasets for building energy flexibility: A review and perspectives

Energy flexibility, through short-term demand-side management (DSM) and energy storage technologies, is now seen as a major key to balancing the fluctuating supply in different energy grids with the energy demand of buildings. This is especially important when considering the intermittent nature of ever-growing renewable energy production, as well as the increasing dynamics of electricity demand in buildings. This paper provides a holistic review of (1) data-driven energy flexibility key performance indicators (KPIs) for buildings in the operational phase and (2) open datasets that can be used for testing energy flexibility KPIs. The review identifies a total of 48 data-driven energy flexibility KPIs from 87 recent and relevant publications. These KPIs were categorized and analyzed according to their type, complexity, scope, key stakeholders, data requirement, baseline requirement, resolution, and popularity. Moreover, 330 building datasets were collected and evaluated. Of those, 16 were deemed adequate to feature building performing demand response or building-to-grid (B2G) services. The DSM strategy, building scope, grid type, control strategy, needed data features, and usability of these selected 16 datasets were analyzed. This review reveals future opportunities to address limitations in the existing literature: (1) developing new data-driven methodologies to specifically evaluate different energy flexibility strategies and B2G services of existing buildings; (2) developing baseline-free KPIs that could be calculated from easily accessible building sensors and meter data; (3) devoting non-engineering efforts to promote building energy flexibility, standardizing data-driven energy flexibility quantification and verification processes; and (4) curating and analyzing datasets with proper description for energy flexibility assessm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Load Modeling and Simulation

Electricity consumer demand response and load control are playing an increasingly important role in the development of a smart grid. Smart grid load management technologies such as Grid FriendlyTM controls and real-time pricing are making their way into the conventional model of grid planning and operations. However, the behavior of load both affects, and is affected by load control strategies that are designed to support electric grid planning and operations. This chapter discussed the natural behavior of electric loads, how it interacts with various load control and demand response strategies, what the consequences are for new grid operation concepts and the computing issues these new technologies raise.

Demand Response↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Hydrogen Energy Storage and Power-to-Gas: Establishing Criteria for Successful Business Cases

As the electric sector evolves and increasing amounts of variable generation are installed on the system, there are greater needs for system flexibility, sufficient capacity and greater concern for overgeneration. As a result there is growing interest in exploring the role of energy storage and demand response technologies to support grid needs. Hydrogen is a versatile feedstock that can be used in a variety of applications including chemical and industrial processes, as well as a transportation fuel and heating fuel. Traditionally, hydrogen technologies focus on providing services to a single sector; however, participating in multiple sectors has the potential to provide benefits to each sector and increase the revenue for hydrogen technologies. The goal of this work is to explore promising system configurations for hydrogen systems and the conditions that will make for successful business cases in a renewable, low-carbon future. Current electricity market data, electric and gas infrastructure data and credit and incentive information are used to perform a techno-economic analysis to identify promising criteria and locations for successful hydrogen energy storage and power-to-gas projects. Infrastructure data will be assessed using geographic information system applications. An operation optimization model is used to co-optimizes participation in energy and ancillary service markets as well as the sale of hydrogen. From previous work we recognize the great opportunity that energy storage and power-to-gas but there is a lack of information about the economic favorability of such systems. This work explores criteria for selecting locations and compares the system cost and potential revenue to establish competitiveness for a variety of equipment configurations. Hydrogen technologies offer unique system flexibility that can enable interactions between multiple energy sectors including electric, transport, heating fuel and industrial. Previous research established that hydrogen technologies, and in particular electrolyzers, can respond fast enough and for sufficient duration to participate in electricity markets. This work recognizes that participation in electricity markets and integration with the gas system can enhance the revenue streams available for hydrogen storage systems and quantifies the economic competitiveness and of these systems. A few of the key results include 1) the most valuable revenue stream for hydrogen systems is to sell the produced hydrogen, 2) participation in both energy and ancillary service markets yields the greatest revenue and 3) electrolyzers acting as demand response devices are particularly favorable.

30 DIRECT ENERGY CONVERSION↗

Alternative Approaches for Incentivizing the Frequency Responsive Reserve Ancillary Service

Frequency responsive reserve is the autonomous response of generators and demand response to deviations of system frequency, usually as a result of the instantaneous outage of a large supplier. Frequency responsive reserve arrests the frequency decline resulting in the stabilization of system frequency, and avoids the triggering of under-frequency load-shedding or the reaching of unstablefrequencies that could ultimately lead to system blackouts. It is a crucial service required to maintain a reliable and secure power system. Regions with restructured electricity markets have historically had a lack of incentives for frequency responsive reserve because generators inherently provided the response and on large interconnected systems, more than sufficient response has beenavailable. This may not be the case in future systems due to new technologies and declining response. This paper discusses the issues that can occur without proper incentives and even disincentives, and proposes alternatives to introduce incentives for resources to provide frequency responsive reserve to ensure an efficient and reliable power system.

17 WIND ENERGY↗

Market Evolution: Wholesale Electricity Market Design for 21st Century Power Systems

Demand for affordable, reliable, domestically sourced, and low-carbon electricity is on the rise. This growing demand is driven in part by evolving public policy priorities, especially reducing the health and environmental impacts of electricity service and expanding energy access to under-served customers. Consequently, variable renewable energy resources comprise an increasing share ofelectricity generation globally. At the same time, new opportunities for addressing the variability of renewables are being strengthened through advances in smart grids, communications, and technologies that enable dispatchable demand response and distributed generation to extend to the mass market. A key challenge of merging these opportunities is market design -- determining how to createincentives and compensate providers justly for attributes and performance that ensure a reliable and secure grid -- in a context that fully realizes the potential of a broad array of sources of flexibility in both the wholesale power and retail markets. This report reviews the suite of wholesale power market designs in use and under consideration to ensure adequacy, security, and flexibilityin a landscape of significant variable renewable energy. It also examines considerations needed to ensure that wholesale market designs are inclusive of emerging technologies, such as demand response, distributed generation, and storage.

21st Century Power Partnership↗

Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services

Demand response and energy storage play a profound role in the smart grid. The focus of this paper is to evaluate benefits of coordination of flexible loads and energy storage for power grid and end user services. We present a Generalized Battery Model (GBM) to describe the flexibility of building loads and energy storage. A Model Predictive Control (MPC) approach is proposed to characterize the GBM parameters (power and energy limits) for flexible building loads. Moreover, we develop optimal coordination algorithms for them to provide ancillary and end user services such as energy arbitrage, frequency regulation, spinning reserve, as well as energy and demand charge reduction. Several case studies have been performed to demonstrate the efficacy of the GBM and coordination algorithms, and evaluate the benefits of using their flexibility to provide grid and end user services. We show that optimal coordination yields significant cost saving and revenue. Moreover, the best option for grid services is to provide energy arbitrage and frequency regulation, because spinning reserve cannot compete with regulation service. Furthermore, when coordinating flexible loads with energy storage to provide end user services, it is recommended to consider both the time-of-use (TOU) price and demand charge rather than the TOU price only in order to flat the aggregate power profile.

Hao, He↗

Integrating solar into Florida's power system: Potential roles for flexibility

Although Florida has very little photovoltaic (PV) generation to date, it is reasonable to expect significant deployment in the 2020s under a variety of future policy and cost scenarios. To understand these potential futures, we model Florida Reliability Coordinating Council operations in 2026 over a wide range of PV penetrations with various combinations of battery storage capacity, demand response, and increased operational flexibility. By calculating the value of PV under a wide range of conditions, we find that at least 5%, and more likely 10-24%, PV penetration is cost competitive in Florida within the next decade with baseline flexibility and all but the most pessimistic of assumptions. For high PV penetrations, we demonstrate Florida's electrical net-load variability (duck curve) challenges, the associated reduction of PV's value to the system, and the ability of flexibility options-in particular energy-shifting resources-to preserve value and increase the economic carrying capacity of PV. A high level of demand response boosts the economic carrying capacity of PV by up to 0.5-2 percentage points, which is comparable to the impact of deploying 1 GW of battery storage. Adding 4 GW of battery storage expands the economic carrying capacity of PV by up to 6 percentage points.

14 SOLAR ENERGY↗

Impact of Control on Availability and Cycling of Residential HVAC in a Real-World Experiment

Demand response is an important emerging part of smart grids and there is a large stream of research from theoretical and modeling perspectives. However, there is relatively little experimental evidence that could help researchers and building operators make informed decisions on best practices for modeling, developing, and deployment of control mechanisms. We contribute to the body of experimental research by providing numerical insights into the role and availability of residential HVAC systems for control. We share the findings on the duration of the cooling cycle, off cycle, and temperature settling time of HVAC systems from data collected from a smart neighborhood located in Atlanta, GA.

cycling↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement-Learning-Based Smart Water Heater Control: An Actual Deployment

Utilizing smart control algorithms for electric water heaters (EWHs) is essential for fully harnessing the demand response (DR) potential of EWHs. For this reason, the use of reinforcement learning (RL) algorithms for EWHs has received increasing attention in recent years. However, existing RL approaches are either simulation-based or use pretrained RL agents. To this end, this paper presents the real-world deployment of a set of model-free RL approaches that aim to minimize the electricity cost of a EWH under a time-of-use electricity pricing policy using standard DR commands (e.g., shed, load up). The experiment results showed that the RL agents can help save electricity cost in the range of 11% to 14% compared to the baseline operation. This study demonstrated that RL-based EWH controllers can be deployed in real world without any prior training and can still save electricity cost.

deep learning↗

slacgismo/pge-baseline-study

Examining existing PG&E baseline methodologies. Load modeling is a complex task, with factors such as weather, time of year, location, purpose of building, and more. This study’s purpose is to use non-Demand-Response data from customers in order to find the most accurate method of predicting load behavior for Demand-Response days.

Serbetcioglu, Berk↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ensemble of Thermostatically Controlled Loads: Statistical Physics Approach

Thermostatically Controlled Loads (TCL), e.g. air-conditioners and heaters, are by far the most wide-spread consumers of electricity. Normally the devices are calibrated to provide the so-called bang-bang control of temperature - changing from on to off , and vice versa, depending on temperature. Aggregation of a large group of similar devices into a statistical ensemble is considered, where the devices operate following the same dynamics subject to stochastic perturbations and randomized, Poisson on/off switching policy. We analyze, using theoretical and computational tools of statistical physics, how the ensemble relaxes to a stationary distribution and establish relation between the re- laxation and statistics of the probability flux, associated with devices' cycling in the mixed (discrete, switch on/off , and continuous, temperature) phase space. This allowed us to derive and analyze spec- trum of the non-equilibrium (detailed balance broken) statistical system. and uncover how switching policy affects oscillatory trend and speed of the relaxation. Relaxation of the ensemble is of a practical interest because it describes how the ensemble recovers from significant perturbations, e.g. forceful temporary switching o aimed at utilizing flexibility of the ensemble in providing "demand response" services relieving consumption temporarily to balance larger power grid. We discuss how the statistical analysis can guide further development of the emerging demand response technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗