Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Neutron Dosimetry for the Boise State University JW 15-8242 Irradiation in ATR (Rev.1)

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the Boise State University (BSU) JW 15-8242 irradiations which were conducted in positions A6, A7 and A8 of the ATR. We previously reported data for this experiment after about 1 dpa in a report issued in January 2021 (1). This report is for longer irradiations to about 3 dpa. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the BSU assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 173-C

Results of neutron dosimetry measurements in ATR for cycle 173-C are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advancements in PTFE/EPR Reactor Dosimetry

Discussion of current efforts by Radiation Metrology Laboratory at Sandia to continue development and deployment of an EPR/PTFE dosimetry system.

Vehar, David W. [Sandia National Laboratories (SNL↗

Advanced Test Reactor Neutron Dosimetry Report – 174 A & B

Results of neutron dosimetry measurements in ATR for cycle 174 A B are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of physics, instrumentation and dosimetry of radioactive isotopes

General radioactive isotope information, stressing radioactivity, methods of measurement, and dosimetry of radioactive nuclides have been reviewed to serve as a reference for the medical profession. Instability of radionuclides, principal types of emission, and measurement of ionizing radiation are among the topics discussed.

Sinclair, W. K.↗

Heavy ion passive dosimetry with silver halide single crystals

A method of detecting radiation damage tracks due to heavy particles in large single crystals of the silver halides is described. The tracks, when made visible with a simple electrical apparatus, appear similar to tracks in emulsions. The properties of the crystals, the technique of printing out the tracks, and evidence concerning the threshold energy for registering particles indicates that this method may find application in heavy ion dosimetry. The method has been found to be sensitive to stopping He nuclei and relativistic M group cosmic rays. Some impurities strongly influence the printout of the tracks, and the effects of these impurities are discussed.

Childs, C. B.↗

High Z particle Apollo astronaut dosimetry with plastics

On Apollo missions, the individual astronauts' high Z particle exposure is measured by means of Lexan polycarbonate plastic. These layers form one component of the passive dosimetry packets worn in the constant wear garment. They serve as threshold type, high Z, charged particle track detectors, recording only the very highly ionizing particles. The detectors yield information on the particles' charge, energy, and direction of travel. This data, in turn, is used to obtain the track fluence, the stopping particle density as an integral Z distribution, and the particles' integral LET spectrum. Some of the data gathered on Apollo missions 8-13 is presented.

Benton, E. V.↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Distribution effectiveness for space radiation dosimetry

A simplified risk basis and a theory of hematological response are presented and applied to the problem of dosimetry in the manned space program. Unlike previous studies, the current work incorporates radiation exposure distribution effects into its definition of dose equivalent. The fractional cell lethality model for prediction of hematological response is integral in the analysis.

Wilson, J. W.↗

Dosimetry of low energy proton beams for use in spacecraft parts testing

Thermoluminescent Dosimeters tes (TLD) were used to measure proton fluences consisting of 5MeV or lower energies. The results were at variance with the corresponding gamma measurements. The results of experiments on low energy proton dosimetry using LiF-in-teflon microrods (TLD-700 or LiF-7), are presented.

Miller, C. G.↗

Dosimetry during space missions

Comparative radiation hazards due to various sources of radiation in several prominent manned space missions are surveyed, along with techniques for coping with the hazards. Cosmic radiation of solar and galactic origin, and Van Allen belt radiation, are the major hazards outside the earth's geomagnetic shield, and were a major problem in the Apollo missions. The Skylab missions, while within the geomagnetic field, were subject to extensive exposure to the trapped radiation belts (Van Allen belts), while the Soyuz-Apollo test project involved orbiting at a lower altitude, with lower exposure. No solar particle bursts affected Apollo missions, and the Solar Particle Alert Network devised to help cope with the problem is described. Dosimetry practices and devices are described. Radiation experience and dose readings logged with the various missions are reported.

Bailey, J. V.↗

Radiological protection and medical dosimetry for the Skylab crewmen

Dosimetry results for Skylab crewmembers show that the Skylab 4 crewmen received the highest dose equivalents but remained well within the established limits for Skylab missions below the threshold of significant clinical effects. These dose equivalents apply specificially to long term effects such as general life shortening, increased neoplasm incidence, and cataract production. A Skylab crewman could fly a mission comparable to one 84-day Skylab 4 mission per year for 50 years before exceeding these career limits.

Bailey, J. V.↗

Radiation effects on MOS devices - dosimetry, annealing, irradiation sequence, and sources

This paper reports on some investigations of dosimetry, annealing, irradiation sequences, and radioactive sources, involved in the determination of radiation effects on MOS devices. Results show that agreement in the experimental and theoretical surface to average doses support the use of thermo-luminescent dosimeters (manganese activated calcium fluoride) in specifying the surface dose delivered to thin gate insulators of MOS devices. Annealing measurements indicate the existence of at least two energy levels,,s or a activation energies, for recovery of soft oxide MOS devices after irradiation by electrons, protons, and gammas. Damage sensitivities of MOS devices were found to be independent of combinations and sequences of radiation type or energies. Comparison of various gamma sources indicated a small dependence of damage sensitivity on the Cobalt facility, but a more significant dependence in the case of the Cesium source. These results were attributed to differences in the spectral content of the several sources.

Stassinopoulos, E. G.↗

Summary of current radiation dosimetry results on manned spacecraft

It is pointed out that the experimental data existing on radiation levels inside orbiting spacecraft are currently limited. However, it is recognized that perhaps the single most important constraint to long-term manned space activity may be related to the complex space radiation environment. For this reason, it is important to know the radiological parameters which determine the biological effects of space radiation on humans. Attention is given to radiation dose measurements, LET (linear energy transfer) spectra for HZE particles, and dosimetry data from U.S. manned spaceflights. In particular, data are now available on dose rates in spacecraft at low altitudes (less than 300 km), while insufficient measurements exist for high altitude and high inclination orbits, geostationary orbits, and many orbits in between. Very little data exist on neutron dose and spectra.

Benton, E. V.↗

Space radiation shielding analysis and dosimetry for the Space Shuttle program

Active and passive radiation dosimeters have been flown on every Space Shuttle mission to measure the naturally-occurring, background Van Allen and galactic cosmic radiation doses that astronauts and radiation-sensitive experiments and payloads receive. A review of the various models utilized at the NASA/Johnson Space Center, Radiation Analysis and Dosimetry is presented. An analytical shielding model of the Shuttle was developed as an engineering tool to aid in making premission radiation dose calculations and is discussed in detail. The anatomical man models are also discussed. A comparison between the onboard dosimeter measurements for the 24 Shuttle missions to date and the dose calculations using the radiation environment and shielding models is presented.

Atwell, William↗