Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Direct measurement of the contribution of street lighting to satellite observations of nighttime light emissions from urban areas

Nighttime light emissions are increasing in most countries worldwide, but which types of lighting are responsible for the increase remains unknown. Also unknown is what fraction of outdoor light emissions and associated energy use are due to public light sources (i.e. streetlights) or various types of private light sources (e.g. advertising). Here we show that it is possible to measure the contribution of street lighting to nighttime satellite imagery using ‘smart city’ lighting infrastructure. The city of Tucson, USA, intentionally altered its streetlight output over 10 days, and we examined the change in emissions observed by satellite. We find that streetlights operated by the city are responsible for only 13% of the total radiance (in the 500–900 nm band) observed from Tucson from space after midnight (95% confidence interval 10–16%). If Tucson did not dim their streetlights after midnight, the contribution would be 18% (95% confidence interval 15–23%). When streetlights operated by other actors are included, the best estimates rise to 16% and 21%, respectively. Existing energy and lighting policy related to the sustainability of outdoor light use has mainly focused on street lighting. These results suggest an urgent need for consideration of other types of light sources in outdoor lighting policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing perceptions of a dimmable LED lighting system between a real space and a virtual reality display

Over the last several decades, designers have used digital screens to view images of real and simulated spaces and make critical design decisions. Screen technology has improved during this time, as technologies like OLED have replaced legacy displays (CRT, plasma, and LCD). These new screens provide a higher pixel resolution, luminous output and contrast ratio. Immersive head-mounted displays now allow designers to view immersive images, and recent developments in real-time rendering have encouraged the uptake of virtual reality (VR) head-mounted displays in mainstream practice and design education. This paper presents an experiment on lighting perception using a series of LED lighting conditions in a real space and a virtual representation of those conditions captured using a 360° high-dynamic-range camera and presented on an HTC Vive Pro HMD. Fifty-three participants were asked to rate each lighting condition by viewing it in a real space (n = 30) or via immersive HDR photographs displayed in a VR HMD (n = 23). The results show that ratings of visual comfort, pleasantness, evenness, contrast and glare are similar between the HTC Vive Pro HMD and our real space when evaluating well-lit scenes, but significant differences emerge in dim and highly contrasted scenes for a number of rating scales.

Rockcastle, S.↗

Lighting Control in Patient Rooms: Understanding Nurses’ Perceptions of Hospital Lighting Using Qualitative Methods

Here, this study differs in its methodological approach from previously published research by interpreting qualitative results against existing literature to understand how nurses conceptualize medical–surgical patient rooms as productive settings in relation to lighting, as well as the ways in which nurses believe these spaces could be enhanced for patient satisfaction. Content analysis was used to interpret themes emerging from nurses’ subjective responses to open-ended items. Three of the facilities had older, traditional lighting systems; one had a contemporary framework. A theme of environmental control over both overhead and task lighting emerged from data from all items. Although controllability was among the “best” lighting attributes, more refinement is necessary for optimal staff productivity and patient satisfaction. Daylighting was also considered to be among the best attributes. Control over light level via additional dimming capability for patients, as well as additional light sources, was prominent across the four hospitals. Unique to the more modern facility, trespassing of light was problematic for nurses considering the experiences of patients—even where modern models exist, more attention can be paid to the ways in which window shades, and light sources outside of rooms, penetrate spaces and affect users. Finally, the finding that nurses and patients desire greater control over the lighting in patient rooms is consistent with Ulrich’s theory of supportive design for healthcare and coincides with advances in lighting technology. Despite differences in the level of sophistication in lighting among the four facilities, control continues to be a primary concern for nurses.

60 APPLIED LIFE SCIENCES↗

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bobfinchite, Na[(UO2)8O3(OH)11]·10H2O, a new Na-bearing member of the schoepite family

Abstract The new mineral bobfinchite (IMA2020-082), Na[(UO2)8O3(OH)11]·10H2O, was found in the Burro mine, Slick Rock district, San Miguel County, Colorado, U.S.A., where it occurs as an oxidation product of uraninite on asphaltite matrix in intimate association with gypsum, natrozippeite, metaschoepite, and uranopilite. Bobfinchite crystals are transparent to translucent, yellow, lozenge-shaped disks up to 0.3 mm wide. Crystals are flattened on [100] and exhibit the forms {100}, {011}, {021}, {021}, and {011}. Bobfinchite has a pale-yellow streak and emits very dim yellow fluorescence under 365 nm ultraviolet illumination. The crystals are brittle with very good {100} cleavage and irregular, stepped fracture. The Mohs hardness is ca. 2 based on scratch tests. The calculated density is 5.044 g/cm3 based on the empirical formula and 5.036 g/cm3 for the ideal formula. Bobfinchite is optically biaxial (–), with α = 1.690(5), β = 1.7205(5), and γ = 1.730(5) (white light). The measured 2V, estimated from the interference figure, is 55(5)° and the calculated value is 59.1°. Dispersion is moderate, r > v; orientation: X = a, Y = b, Z = c; pleochroism: X nearly colorless, Y yellow, Z yellow; X < Y ≈Z. Electron microprobe analysis provided the empirical formula (Na0.99Pb0.02)[(UO2)7.99O3(OH)11]·10H2O. The five strongest X-ray powder diffraction lines are [dobs in Å(I)(hkl)]: 7.34(100)(200), 3.59(50)(024), 3.23(60)(224), 3.18(36)(240), and 2.01(23)(624,551,208,640,346). Bobfinchite is orthorhombic, Pbcn, a = 14.6249(9), b = 14.0389(10), c = 16.6923(10) Å, V = 3427.2(4) Å3, and Z = 4. The structure of bobfinchite (R1 = 0.0330 for 3770 I > 4σI) is built from uranyl oxide-hydroxide sheets that adopt the fourmarierite topology, with interlayer Na+ and H2O groups. Both the sheet and interlayer topology mimic those observed in natural and synthetic Na-metaschoepites studied previously, and as seen in other uranyl oxide hydrate minerals, charge balance is achieved at specific sites in the sheet through the substitution O2– ↔ (OH)–.

Geochemistry & Geophysics↗

Reported light in the sleep environment: enhancement of the sleep diary

Light is the primary synchronizing cue for the circadian timing system, capable of exerting robust physiological effects, even with very dim and/or brief photic exposure. Mammals, including humans, are particularly susceptible to light at night. As such, measures of light in the sleeping environment are critical for evaluating sleep health. Sleep diaries provide inexpensive measures of sleep, but do not typically include light information. Four questions probing visual perception of light in the bedtime and waking environments were added to the Consensus Sleep Diary for Morning administration. As part of a lighting intervention study, 18 hospital Labor and Delivery Department personnel completed the sleep diary for 1 week in each of two experimental conditions while wearing Actiwatch devices equipped with photosensors. Diary responses were evaluated against photosensor values from the beginning and end of each rest interval (n=194 rest intervals), as well as against sleep measures, utilizing linear mixed models. Responses to light questions were related to actual light measures at bedtime, controlling for shift type and experimental condition. In addition, subjective light information at bedtime and waking was related to both objective and subjective sleep parameters, with data generally indicating poorer sleep with light in the sleeping environment. Questions addressing perception of light in the sleeping environment may provide a crude yet affordable metric of relative photic intensity. Further, as responses relate to sleep outcomes, subjective light information may yield valuable insights regarding mechanisms and outcomes of clinical significance in sleep and circadian research.

59 BASIC BIOLOGICAL SCIENCES↗

Stability Measurements for Alignment of the NIF Neutron Imaging System Pinhole Array

The alignment system for the National Ignition Facility's neutron imaging system has been commissioned and measurements of the relative stability of the 90-315 DIM, the front and the back of the neutron imaging pinhole array and an exploding pusher target have been made using the 90-135 and the 90-258 opposite port alignment systems. Additionally, a laser beam shot from the neutron-imaging Annex and reflected from a mirror at the back of the pinhole array was used to monitor the pointing of the pinhole. Over a twelve hour period, the relative stability of these parts was found to be within {approx} {+-}18 {micro}m rms even when using manual methods for tracking the position of the objects. For highly visible features, use of basic particle tracking techniques found that the front of the pinhole array was stable relative to the 90-135 opposite port alignment camera to within {+-}3.4 {micro}m rms. Reregistration, however, of the opposite port alignment systems themselves using the target alignment sensor was found to change the expected position of target chamber center by up to 194 {micro}m.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Resolution K Shell X-Ray Spectroscopy Experiments

The Subcontractor is to design a spectrometer that can be fielded in a NIF DIM that has three cylindrically-bent transmission crystals covering (1) 6-20 keV, (2) 10-150 keV, and (3) 50-511 keV. This work will build on the NRL Dual Crystal Spectrometer (DCS) having two crystals covering 10-50 keV and 20-120 keV and fielded at the LLNL/Titan and LLE/Omega laser facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Zone Level Occupant-Responsive Building Energy Systems at the GSA

The General Services Administration (GSA) partnered with the U.S. Department of Energy (DOE) to develop and implement building energy system retrofits, aiming to reduce energy consumption of at least two building systems by a total of 30 percent or more, as part of DOE’s Commercial Building Partnership (CBP) Program. Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program, working with the GSA and a team of consultants. This case study reports expected energy savings from appropriate energy efficient design and operations modifications to lighting and heating, ventilating and air conditioning (HVAC) systems at the selected study sites. These retrofits comprised installation of new lighting systems with dimming capability and occupancy-sensor control at the individual light fixture level, and utilized lighting system occupancy sensor signals to continually readjust zone-level ventilation airflow according to the number of people present, down to minimum rates when vacant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NIF S600D Snout Final Design Review (FDR) Report

The S600D is a one or two channel mirror spectrometer which will provide temporal and spatial soft x-ray data in a single NIF shot. It mounts to the existing DIM Imaging Streak Camera (DISC) using the standard NIF kinematic mount design. LLE and LLNL each have responsibilities for the snout. The Laboratory for Laser Energetics (LLE) is subcontracted to design, fabricate, and align the S600D Snout at the OMEGA Laser facility in Rochester, NY before delivery to LLNL. The Snout consists of the Mirror Mount, Kinematic interface to DISC, Slit mount, and filter pack mount. Lawrence Livermore National Laboratory (LLNL) is responsible to fabricate and deliver the Mirror substrates and coatings, Pinhole slits and collimators, Filter material, and Image plates. LLNL is also responsible for the Requirements Definition, Concept of Operations, Debris and Shrapnel analysis, Stakeholder reviews and Integration in the NIF Facility.

42 ENGINEERING↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Exploratory Study: Recessed Troffer Lighting

This CALiPER study examines the problems and benefits likely to be encountered with LED products intended to replace linear fluorescent lamps. LED dedicated troffers, replacement tubes, and non-tube retrofit kits were evaluated against fluorescent benchmark troffers in a simulated office space for photometric distribution, uniformity of light on the task surface, suitability of light output, flicker, dimming performance, color quality, power quality, safety and certification issues, ease of installation, energy efficiency, and life-cycle cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next Generation Luminaire (NGL) Downlight Demonstration Project, Hilton Columbus Downtown

At the Hilton Columbus Downtown hotel in Ohio, DOE's Better Buildings Alliance conducted a demonstration of Next Generation Luminaires-winning downlights installed in all guest rooms and suites prior to the hotel's 2012 opening. After a post-occupancy assessment, the LED downlights not only provided the aesthetic appearance and dimming functionality desired, but also provided 50% energy savings relative to a comparable CFL downlight and enabled the lighting power to be more than 20% below that allowed by code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential energy savings with exterior shades in large office buildings and the impact of discomfort glare

Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems. While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Luminaires for Advanced Lighting in Education

Evolving education methods and greater use of technology in the classroom are dictating the need to rethink facility designs, including classroom lighting. Advances in LED-based lighting technology have created the possibility of lighting systems that are not only cost effective and energy efficient, but also color-tunable and as durable as other facility infrastructures (a 20-30 year life expectancy). Thus, there is the opportunity that the modern lighting system can be used by educators as a tool in their teaching strategy. To meet this need, RTI International and Finelite, Inc. teamed to develop and test the Next Generation Integrated Classroom Lighting System (NICLS). The NICLS technology incorporates a high performance, color-tunable light engine into new luminaire designs (e.g., pendant, direct-indirect, downlight, troffers) that are acceptable for use in classrooms. During this project, we successfully demonstrated that the NICLS technology achieves exceptional performance and exceeds all DOE goals for the classroom of the future, including: Luminous efficacy value for NICLS luminaires in excess of 125 lpw at all CCT values; TWL range of 2,700 K to 6,500 K while maintaining a CRI of 82 or higher at all values; Capability for full-range dimming (100% to 1%) at all CCT values with flicker levels below industry guidelines; Performance of the lighting system in a classroom mock-up, incorporating daylight and occupancy sensing to provide automatic control of lighting zones to further reduce energy consumption; Rated lifetime on the system exceeding 50,000 hours with a lumen maintenance of at least 85% at 50,000 hours; and Teacher-focused UI located at the front of the classroom to operate the lighting system. A smartphone-based UI is also available to accommodate teacher movement in the classroom. A critical element of developing this technology is designing the user interface to be compatible with modern teaching methods, including increased use of icons and colors and intuitive appearance. The design of the NICLS technology and the user interface was modified with assistance from focus groups consisting of more than 80 teachers and educational professionals total. The focus groups were held in a full-sized classroom that served as a technology demonstration site for the NICLS. The NICLS technology is an advanced lighting system for educational settings that meets or exceeds all DOE photometric, electrical, and reliability goals for the COF. The NICLS technology has been demonstrated at the classroom level, and the feedback from the dozens of teachers and educational professionals who visited the demonstration site has been overwhelmingly positive. NICLS provides a state-of-the-art lighting environment that adjusts the lighting conditions—both color and illuminance levels—to the needs of students and teachers for the task at hand. Early research has suggested that such lighting conditions will improve not only teacher effectiveness but also a student’s ability to concentrate on learning activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Tuning Hospital Lighting: Evaluating Tunable LED Lighting at the Swedish Hospital Behavioral Health Unit in Seattle

The GATEWAY program evaluated a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit

Summary of a GATEWAY report evaluation of a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

59 BASIC BIOLOGICAL SCIENCES↗