Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Whole Neuraxis Irradiation to Address Central Nervous System Relapse in High-Risk Neuroblastoma

Background: As systemic control of high-risk neuroblastoma (NB) has improved, relapse in the central nervous system (CNS) is an increasingly recognized entity that carries a grim prognosis. This study describes the use of craniospinal irradiation (CSI) for CNS relapse and compares outcomes to patients who received focal radiotherapy (RT). Methods: A retrospective query identified 29 children with NB treated at Memorial Sloan-Kettering Cancer Center since 1987 who received RT for CNS relapse. At CNS relapse, 16 patients received CSI (median dose, 2160cGy), and 13 received focal RT. Of those who underwent CSI, 14 (88%) received intra-Ommaya (IO) radioimmunotherapy (RIT); one patient in the non-CSI cohort received IO-RIT. Results: Patient characteristics were similar between the groups. Time to CNS relapse was 20 and 17 months for the CSI and non-CSI cohorts, respectively. At a median follow-up of 28 months, 12 patients (75%) in the CSI group are alive without CNS disease, including two patients with isolated skeletal relapse. Another patient is alive without disease after a brain relapse was retreated with RT. Three patients died-one with no NB at autopsy, one of CNS disease, and one of systemic disease. The two patients who died of NB did not receive IO-RIT. All 13 patients in the non-CSI cohort died at a median of 8.8 months. Conclusions: Low-dose CSI together with IO-RIT provides durable CNS remissions and improved survival compared with focal RT and conventional therapies. Further evaluation of long-term NB survivors after CSI is warranted to determine the treatment consequences for this cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma Knife Radiosurgery for Treatment of Cerebral Metastases From Non-Small-Cell Lung Cancer

Purpose: To evaluate clinical and physico-dosimetric variables affecting clinical outcome of patients treated with Gamma Knife radiosurgery (GKRS) for brain metastases from non-small cell lung cancer (NSCLC). Methods and Materials: Between 2001 and 2006, 373 patients (298 men and 75 women, median age 65 years) with brain metastases from NSCLC underwent GKRS. All of them had KPS {>=} 60%, eight or fewer brain metastases, confirmed histopathological diagnosis and recent work-up (<3 months). Thirty-five patients belonged to recursive partitioning analysis (RPA) Class I, 307 patients were in RPA Class II, 7 patients were in RPA Class III. Median tumor volume was 3.6 cm{sup 3}. Median marginal dose was 22.5 Gy at 50% isodose.; median 10 Gy and 12 Gy isodose volumes were 30.8 cm{sup 3} and 15.8 cm{sup 3}, respectively. Follow-up with MRI was performed every 3 months. Overall survival data were collected from internal database, telephone interviews, and identifying registries. Results: Mean follow-up after GKRS was 51 months (range, 6 to 96 months); mean overall survival was 14.2 months. Of 373 patients, 29 were alive at time of writing, 104 had died of cerebral progression, and 176 had died of systemic progression. In 64 cases it was not possible to ascertain the cause. Univariate and multivariate analysis were adjusted for the following: RPA class, surgery, WBRT, age, gender, number of lesions, median tumor volume, median peripheral dose, and 10 Gy and 12 Gy volumes. Identified RPA class and overall tumor volume >5 cc were the only two covariates independently predictive of overall survival in patients who died of cerebral progression. Conclusions: Global volume of brain disease should be the main parameter to consider for performing GKRS, which is a first-line therapy for patient in good general condition and controlled systemic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Phase 2 Trial of Reirradiation With Stereotactic Body Radiation Therapy Plus Cetuximab in Patients With Previously Irradiated Recurrent Squamous Cell Carcinoma of the Head and Neck

Purpose: Salvage options for unresectable locally recurrent, previously irradiated squamous cell carcinoma of the head and neck (rSCCHN) are limited. Although the addition of reirradiation may improve outcomes compared to chemotherapy alone, significant toxicities limit salvage reirradiation strategies, leading to suboptimal outcomes. We therefore designed a phase 2 protocol to evaluate the efficacy of stereotactic body radiation therapy (SBRT) plus cetuximab for rSCCHN. Methods and Materials: From July 2007 to March 2013, 50 patients >18 years of age with inoperable locoregionally confined rSCCHN within a previously irradiated field receiving ≥60 Gy, with a Zubrod performance status of 0 to 2, and normal hepatic and renal function were enrolled. Patients received concurrent cetuximab (400 mg/m{sup 2} on day −7 and then 250 mg/m{sup 2} on days 0 and +8) plus SBRT (40-44 Gy in 5 fractions on alternating days over 1-2 weeks). Primary endpoints were 1-year locoregional progression-free survival and National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0 graded toxicity. Results: Median follow-up for surviving patients was 18 months (range: 10-70). The 1-year local PFS rate was 60% (95% confidence interval [CI]: 44%-75%), locoregional PFS was 37% (95% CI: 23%-53%), distant PFS was 71% (95% CI: 54%-85%), and PFS was 33% (95% CI: 20%-49%). The median overall survival was 10 months (95% CI: 7-16), with a 1-year overall survival of 40% (95% CI: 26%-54%). At last follow-up, 69% died of disease, 4% died with disease, 15% died without progression, 10% were alive without progression, and 2% were alive with progression. Acute and late grade 3 toxicity was observed in 6% of patients respectively. Conclusions: SBRT with concurrent cetuximab appears to be a safe salvage treatment for rSCCHN of short overall treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Gate Width Setting and Gate Utilization Factors on Plutonium Assay in Passive Correlated Neutron Counting

In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimum gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolution Versus Error for Computational Electron Microscopy

Images that are collected via scanning transmission electron microscopy (STEM) can be undersampled to avoid damage to the specimen while maintaining resolution [1, 2]. We have used BPFA to impute missing data and reduce noise [3]. The reconstruction is typically evaluated using the peak signal-to-noise ratio (PSNR). This measure is too conservative for STEM images and we propose that the Fourier ring correlation (FRC) is used instead to evaluate the reconstruction. We are not concerned with exact reconstruction of the truth image, and therefore PSNR is a conservative estimation of the quality of the reconstruction. Instead, we are concerned with the visual resolution of the image and whether atoms can be distinguished. We have evaluated the reconstruction of a simulated STEM image using the FRC and compared the results with the PSNR measurements. The FRC captures the resolution of the image and is not affected by a large MSE if the atom peaks are still distinguishable. The noisy and reconstructed images are shown in Figure 1. The simulated STEM image was sampled at 100%, 80%, 40%, and 20% of the original pixels to simulate an undersampled scan. The reconstruction was done using BPFA with a patch size of 10 x 10 and no overlapping patches. Not having overlapping patches produces inferior results but they are still acceptable. The dictionary size is 64 and 30 iterations were completed during each reconstruction. The 100% image was denoised instead of reconstructed. Poisson noise was applied to the simulated image with λ values of 500, 50, and 5 to simulate lower imaging dose. The original simulated STEM image was also included in our calculations and was generated using a dose of 1000. The simulated STEM image is 100 by 100 pixels and has essentially no high frequency components. The image reconstruction tends to smooth the data, also resulting in no high frequency components. This causes the FRC of the two images to be large at higher resolutions and may be misleading. For this reason, the BPFA has no overlap to avoid excessive smoothing. Moreover, the resolution of the simulated image is approximately 9.2 (1/nm), so we only look that far in the frequency domain when performing FRC. If the FRC curve does not crossover the threshold, a resolution value of 9.2 is used. We emphasize that our reported results are conservative. The FRC and PSNR values using the ground truth and the reconstructed images are shown in Tables 1 and 2. The left side show the metrics without using BPFA (missing pixels) and the right side show the metrics after using BPFA. When we did not use BPFA, the Fourier transform was estimated [4]. Some threshold curves have been studied [5], but they are derived for additive noise models. Since we have a Poisson noise model, we have used the more conservative threshold of 0.5 for our calculations. Ten images were used to construct each cell of tables in the form of the mean of the metric plus or minus its standard deviation. As expected, the PSNR dies off much quicker than the FRC values for the same image. For the 100% and 80% sampled versions of the truth image, the resolution only dies off when the dose is 5. However, the PSNR dies off rapidly as the dose is reduced. For the 1000, 500, and 50 dose images, the FRC is the maximum, or close, until we undersample at 20%. The PSNR for these values tapers down as we get into the bottom right hand corner of the table, even though the resolution remains high. Overall, we find that undersampled images can be reconstructed to acceptable resolution even when the dose per pixel is also reduced[6]. References: [1]A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2]A Stevens, L Kovarik, P Abellan et al. Advanced Structural and Chemical Imaging 1(1), (2015), pp. 1. [3]M Zhou, H Chen, J Paisley et al. Image Processing, IEEE Transactions on 21(1), (2012), pp. 130. [4]V. Y. Liepin’sh. Automatic control and computer sciences 30(3), (1996), pp. 20.

Luzi, Lorenzo↗

High Temperature Oxidation Behavior of HVOF-sprayed Coatings for Use in Thixoextrusion Processes

The dies used for the thixoextrusion of steels have to be capable of withstanding complex thermal and mechanical loads, while giving a sufficient wear resistance against abrasion and adhesion at very high temperatures. In order to improve the wear resistance and reduce the heating of the extrusion die it can be protected with a hard cermet coating. The purpose of this work is to study the high-temperature performance of CrC-CoNiCrAlY coating and explore the potential application of this coating to improve dies used in thixoextrusion processes. A two-layer 75CrC-25CoNiCrAlY coating with a CoNiCrAlY bond-coating was fabricated by the HVOF thermal spray process on a steel substrate. Coatings were heat-treated at a range of temperatures between 900 deg. C and 1100 deg. C. The microstructural characterization of the coatings before and after heat treatment was conducted by scanning electron microscopy (SEM) and an X-ray diffractometer (XRD). The mechanical properties of coatings were determined as a function of the temperature of heat treatment. The bond coat effect on the thermal shock resistance of CrC-CoNiCrAlY coating was analyzed.

36 MATERIALS SCIENCE↗

Joining of Aluminium Alloy Sheets by Rectangular Mechanical Clinching

A mechanical clinching has the advantage of low running costs. However, the joint strength is not high. To improve the maximum load of the joined sheets by a mechanical clinching, square and rectangular mechanical clinching were introduced. In the mechanical clinching, the two sheets are mechanically joined by forming an interlock between the lower and upper sheets by the punch and die. The joined length with the interlock was increased by the rectangular punch and die. The deforming behaviours of the sheets in the mechanical clinching were investigated, and then the interlock in the sheets had distribution in the circumference of the projection. Although the interlocks were formed in both projection side and diagonal, the interlock in the diagonal was smaller because of the long contact length between the lower sheet and the die cavity surface. The maximum load of the joined sheets by the rectangular mechanical clinching was two times larger than the load by the round mechanical clinching.

36 MATERIALS SCIENCE↗

Stress-induced Effects Caused by 3D IC TSV Packaging in Advanced Semiconductor Device Performance

Potential challenges with managing mechanical stress and the consequent effects on device performance for advanced 3D through-silicon-via (TSV) based technologies are outlined. The paper addresses the growing need in a simulation-based design verification flow capable to analyze a design of 3D IC stacks and to determine across-die out-of-spec variations in device electrical characteristics caused by the layout and through-silicon-via (TSV)/package-induced mechanical stress. The limited characterization/measurement capabilities for 3D IC stacks and a strict ''good die'' requirement make this type of analysis critical for the achievement of an acceptable level of functional and parametric yield and reliability. The paper focuses on the development of a design-for-manufacturability (DFM) type of methodology for managing mechanical stresses during a sequence of designs of 3D TSV-based dies, stacks and packages. A set of physics-based compact models for a multi-scale simulation to assess the mechanical stress across the device layers in silicon chips stacked and packaged with the 3D TSV technology is proposed. A calibration technique based on fitting to measured stress components and electrical characteristics of the test-chip devices is presented. A strategy for generation of a simulation feeding data and respective materials characterization approach are proposed, with the goal to generate a database for multi-scale material parameters of wafer-level and package-level structures. For model validation, high-resolution strain measurements in Si channels of the test-chip devices are needed. At the nanoscale, the transmission electron microscopy (TEM) is the only technique available for sub-10 nm strain measurements so far.

36 MATERIALS SCIENCE↗

Optimizing the equal channel angular pressing process (ECAP) operation parameters to produce bulk nanostructure materials

In this work we were interested in doing simulation using finite elements analysis (FEA) to study the equal channel angular pressing process (ECAP), which is currently one of the most popular methods of severe plastic deformation Processes (SPD). for fabricating Ultra-Fine Grained (UFG) materials, because it allows very high strains to be imposed leading to extreme work hardening and microstructural refinement. The main object of this study is to establish the influence of main parameters which effect ECAP process which are magnitude of the die angle and the friction coefficient. The angle studied between (90-135°) degree, and magnitude of the friction coefficient μ between (0.12-0.6), and number of pass. The samples were made from aluminum alloy at room temperature with (15X 15) mm cross section and 150 mm length. The simulation result shows that normal elastic strain, shears elastic strain, and max. shear elastic strain increased, when changing the angle from 90° to 100°. and decrease between the angle 110° to 135°. Also the total deformation increased when we change die angle from 90° to 135°. By studding the friction effect on the die and sample we noted that increasing the friction coefficient from 0.12 to 0.6, normal elastic strain, and shear elastic strain increased and increasing the friction coefficient from 0.1 to 0.6 decrease the normal and shear stress.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alternatives to Helium-3 for Neutron Multiplicity Counters

Multiplicity counters are an example of a neutron detection system affected by the shortage of 3He. Efforts are underway to identify potential 3He neutron detector replacements for use in multiplicity counters. Boron-10 and 6Li based systems are two of the options being explored as near-term 3He alternatives for neutron multiplicity counters. Simulations of BF3, 10B-lined proportional counters and 6Li/ZnS(Ag) sheets in various configurations have been performed with the Monte Carlo particle transport code MCNPX and compared to simulations of existing 3He counters. The system performances are being compared using figure of merits that are the square or cube of the total system efficiency divided by the die-away time. Design considerations include developing a system with enough neutron detection material to achieve the highest possible efficiency, while simultaneously minimizing system size. Adequate moderation is required to thermalize the incident neutrons for increased counting efficiency but as the system size increases so will the die-away time (average lifetime of neutrons in the counter). The optimal moderator configuration is one for which the increase in neutron detection efficiency is not defeated by an increase in die-away time. Thus, the entire system performance must be evaluated with every configuration change. The simulation results will be validated against a bench-top demonstrator unit design based on the system identified through simulations as having the highest performance potential. Presented here are the simulation results with various configurations of BF3 filled proportional counters, 10B lined proportional counters and 6Li/ZnS(Ag) sheets, and preliminary bench-top measurements.

Alternatives to Helium-3 for Neutron Multiplicity ↗

NANDFlashSim: High-Fidelity, Microarchitecture-Aware NAND Flash Memory Simulation [NANDFlashSim: Intrinsic Latency Variation Aware NAND Flash Memory System Modeling and Simulation at Microarchitecture Level]

As the popularity of NAND flash expands in arenas from embedded systems to high-performance computing, a high-fidelity understanding of its specific properties becomes increasingly important. Further, with the increasing trend toward multiple-die, multiple-plane architectures and high-speed interfaces, flash memory systems are expected to continue to scale and cheapen, resulting in their broader proliferation. However, when designing NAND-based devices, making decisions about the optimal system configuration is nontrivial, because flash is sensitive to a number of parameters and suffers from inherent latency variations, and no available tools suffice for studying these nuances. The parameters include the architectures, such as multidie and multiplane, diverse node technologies, bit densities, and cell reliabilities. Therefore, we introduce NANDFlashSim, a high-fidelity, latency-variation-aware, and highly configurable NAND-flash simulator, which implements a detailed timing model for 16 state-of-the-art NAND operations. Using NANDFlashSim, we notably discover the following. First, regardless of the operation, reads fail to leverage internal parallelism. Second, MLC provides lower I/O bus contention than SLC, but contention becomes a serious problem as the number of dies increases. Third, many-die architectures outperform many-plane architectures for disk-friendly workloads. Lastly, employing a high-performance I/O bus or an increased page size does not enhance energy savings.

97 MATHEMATICS AND COMPUTING↗

New Efficient Sparse Space Time Algorithms for Superparameterization on Mesoscales

Superparameterization (SP) is a large-scale modeling system with explicit representation of small-scale and mesoscale processes provided by a cloud-resolving model (CRM) embedded in each column of a large-scale model. New efficient sparse space-time algorithms based on the original idea of SP are presented. The large-scale dynamics are unchanged, but the small-scale model is solved in a reduced spatially periodic domain to save the computation cost following a similar idea applied by one of the authors for aquaplanet simulations. In addition, the time interval of integration of the small-scale model is reduced systematically for the same purpose, which results in a different coupling mechanism between the small- and large-scale models. The new algorithms have been applied to a stringent two-dimensional test suite involving moist convection interacting with shear with regimes ranging from strong free and forced squall lines to dying scattered convection as the shear strength varies. The numerical results are compared with the CRM and original SP. It is shown here that for all of the regimes of propagation and dying scattered convection, the large-scale variables such as horizontal velocity and specific humidity are captured in a statistically accurate way (pattern correlations above 0.75) based on space-time reduction of the small-scale models by a factor of 1/3; thus, the new efficient algorithms for SP result in a gain of roughly a factor of 10 in efficiency while retaining a statistical accuracy on the large-scale variables. Even the models with 1/6 reduction in space-time with a gain of 36 in efficiency are able to distinguish between propagating squall lines and dying scattered convection with a pattern correlation above 0.6 for horizontal velocity and specific humidity. These encouraging results suggest the possibility of using these efficient new algorithms for limited-area mesoscale ensemble forecasting.

99 GENERAL AND MISCELLANEOUS↗

Growth-Mortality Relationships in Piñon Pine ( Pinus edulis ) during Severe Droughts of the Past Century: Shifting Processes in Space and Time

The processes leading to drought-associated tree mortality are poorly understood, particularly long-term predisposing factors, memory effects, and variability in mortality processes and thresholds in space and time. We use tree rings from four sites to investigate Pinus edulis mortality during two drought periods in the southwestern USA. We draw on recent sampling and archived collections to (1) analyze P. edulis growth patterns and mortality during the 1950s and 2000s droughts; (2) determine the influence of climate and competition on growth in trees that died and survived; and (3) derive regression models of growth-mortality risk and evaluate their performance across space and time. Recent growth was 53% higher in surviving vs. dying trees, with some sites exhibiting decades-long growth divergences associated with previous drought. Differential growth response to climate partly explained growth differences between live and dead trees, with responses wet/cool conditions most influencing eventual tree status. Competition constrained tree growth, and reduced trees’ ability to respond to favorable climate. The best predictors in growth-mortality models included long-term (15–30 year) average growth rate combined with a metric of growth variability and the number of abrupt growth increases over 15 and 10 years, respectively. The most parsimonious models had high discriminatory power (ROC >0.84) and correctly classified ~70% of trees, suggesting that aspects of tree growth, especially over decades, can be powerful predictors of widespread drought-associated die-off. However, model discrimination varied across sites and drought events. Weaker growth-mortality relationships and higher growth at lower survival probabilities for some sites during the 2000s event suggest a shift in mortality processes from longer-term growth-related constraints to shorter-term processes, such as rapid metabolic decline even in vigorous trees due to acute drought stress, and/or increases in the attack rate of both chronically stressed and more vigorous trees by bark beetles.

54 ENVIRONMENTAL SCIENCES↗

100 LPW 800 Lm Warm White LED

An illumination grade warm white (WW) LED, having correlated color temperature (CCT) between 2800 K and 3500K and capable of producing 800 lm output at 100 lm/W, has been developed in this program. The high power WW LED is an ideal source for use as replacement for incandescent, and Halogen reflector and general purpose lamps of similar lumen value. Over the two year period, we have made following accomplishments: developed a high power warm white LED product and made over 50% improvements in light output and efficacy. The new high power WW LED product is a die on ceramic surface mountable LED package. It has four 1x1 mm{sup 2} InGaN pump dice flip chip attached to a ceramic submount in 2x2 array, covered by warm white phosphor ceramic platelets called Lumiramica and an overmolded silicone lens encapsulating the LED array. The performance goal was achieved through breakthroughs in following key areas: (1) High efficiency pump LED development through pump LED active region design and epi growth quality improvement (funded by internal programs). (2) Increase in injection efficiency (IE) represented by reduction in forward voltage (V{sub f}) through the improvement of the silver-based p-contact and a reduction in spreading resistance. The injection efficiency was increased from 80% at the start of the program to 96% at the end of the program at 700 mA/mm{sup 2}. (3) Improvement in thermal design as represented by reduction in thermal resistance from junction to case, through improvement of the die to submount connection in the thin film flip chip (TFFC) LED and choosing the submount material of high thermal conductivity. A thermal resistance of 1.72 K/W was demonstrated for the high power LED package. (4) Improvement in extraction efficiency from the LED package through improvement of InGaN die level and package level optical extraction efficiency improvement. (5) Improvement in phosphor system efficiency by improving the lumen equivalent (LE) and phosphor package efficiency (PPE) through improvement in phosphor-package interactions. Another achievement in the development of the phosphor integration technology is the demonstration of tight color control. The high power WW LED product developed has been proven to have good reliability. The manufacturing of the product will be done in Philips Lumileds LUXEON Rebel production line which has produced billions of high power LEDs. The first high power WW LED product will be released to the market in 2011.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interim Report on the Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

This report details the results of the work accomplished for the „Neutron Detection without Helium-3‟ project during the 2011 fiscal year. The primary focus of the project during this year was to develop models using alternatives to helium-3 to investigate the possibilities and optimizations for multiplicity counters in safeguards applications by computer simulations. The multiplicity counter with significant capability, the Epithermal Neutron Multiplicity Counter (ENMC), was used as the baseline requirement for alternative technologies, which, if a suitable alternative can be found, should also satisfy systems with less stringent requirements, including coincidence counters. The project is in collaboration with Los Alamos National Laboratory (LANL), and the baseline model of the ENMC that had been developed at LANL with helium-3 as the detector material was used as a starting point. The model was modified to support optimization investigations, and verified with the helium-3 base material. The model was then modified to incorporate boron-trifluoride (BF3) gas, which can be used as a proportional gas similar to helium-3. The BF3 gas however, cannot be operated at very high pressure, and therefore optimization were performed with lower pressures and involved changing the tube size and number. The simulation of this model is very similar in approach to the model with helium-3 where the simulation ends when the neutron is captured in the boron. The reaction products are easily detected in the proportional gas, and the simulation results of counting the number of reactions matches well with experimental data. Next, the tubes were replaced with boron-lined proportional tubes, where the neutron capture material is a thin boron lining inside the tube wall, and which use standard proportional counting gas. For this alternative, the simulation needs to extend beyond the neutron capture, and track the reaction products, which must exit the boron-lining into the counting gas. The reaction products do not always end up in the counting gas, depending on the boron-lining thickness and neutron capture depth. Methods to track the reaction products have been recently implemented into MCNPX and were verified by using several different approaches. The tube number and size were also varied for the boron-lined case. Finally, work has started on a model of an alternative using lithium-6, another material with a high cross-section for thermal neutron capture. The most promising approach is with lithium fluoride in a zinc sulfide (silver activated) scintillator medium. The neutron is captured in the lithium, and the reaction products trigger scintillation light in the zinc sulfide, which is subsequently detected by photo-multipliers by the use of light guides or fibers. The simulations were performed with the focus on determining the efficiency, which is critical when detecting 2 or 3 neutrons in coincidence, as well as the die-away time, which is a measure of the time required to capture neutrons in the system. The die away time is related to the coincident time gate needed for the system which drives the accidental coincident rate, the primary background or noise in this type of measurement. The usual figure of merit for coincidence type systems, the efficiency squared divided by the die-away time, was calculated for each variation simulated.

helium-3 alternatives↗

Electrohydraulic Forming of Near-Net Shape Automotive Panels

The objective of this project was to develop the electrohydraulic forming (EHF) process as a near-net shape automotive panel manufacturing technology that simultaneously reduces the energy embedded in vehicles and the energy consumed while producing automotive structures. Pulsed pressure is created via a shockwave generated by the discharge of high voltage capacitors through a pair of electrodes in a liquid-filled chamber. The shockwave in the liquid initiated by the expansion of the plasma channel formed between two electrodes propagates towards the blank and causes the blank to be deformed into a one-sided die cavity. The numerical model of the EHF process was validated experimentally and was successfully applied to the design of the electrode system and to a multi-electrode EHF chamber for full scale validation of the process. The numerical model was able to predict stresses in the dies during pulsed forming and was validated by the experimental study of the die insert failure mode for corner filling operations. The electrohydraulic forming process and its major subsystems, including durable electrodes, an EHF chamber, a water/air management system, a pulse generator and integrated process controls, were validated to be capable to operate in a fully automated, computer controlled mode for forming of a portion of a full-scale sheet metal component in laboratory conditions. Additionally, the novel processes of electrohydraulic trimming and electrohydraulic calibration were demonstrated at a reduced-scale component level. Furthermore, a hybrid process combining conventional stamping with EHF was demonstrated as a laboratory process for a full-scale automotive panel formed out of AHSS material. The economic feasibility of the developed EHF processes was defined by developing a cost model of the EHF process in comparison to the conventional stamping process.

36 MATERIALS SCIENCE↗

Solid State Lighting Program (Falcon)

Over the past two years, KLA-Tencor and partners successfully developed and deployed software and hardware tools that increase product yield for High Brightness LED (HBLED) manufacturing and reduce product development and factory ramp times. This report summarizes our development effort and details of how the results of the Solid State Light Program (Falcon) have started to help HBLED manufacturers optimize process control by enabling them to flag and correct identified killer defect conditions at any point of origin in the process manufacturing flow. This constitutes a quantum leap in yield management over current practice. Current practice consists of die dispositioning which is just rejection of bad die at end of process based upon probe tests, loosely assisted by optical in-line monitoring for gross process deficiencies. For the first time, and as a result of our Solid State Lighting Program, our LED manufacturing partners have obtained the software and hardware tools that optimize individual process steps to control killer defects at the point in the processes where they originate. Products developed during our two year program enable optimized inspection strategies for many product lines to minimize cost and maximize yield. The Solid State Lighting Program was structured in three phases: i) the development of advanced imaging modes that achieve clear separation between LED defect types, improves signal to noise and scan rates, and minimizes nuisance defects for both front end and back end inspection tools, ii) the creation of defect source analysis (DSA) software that connect the defect maps from back-end and front-end HBLED manufacturing tools to permit the automatic overlay and traceability of defects between tools and process steps, suppress nuisance defects, and identify the origin of killer defects with process step and conditions, and iii) working with partners (Philips Lumileds) on product wafers, obtain a detailed statistical correlation of automated defect and DSA map overlay to failed die identified using end product probe test results. Results from our two year effort have led to “automated end-to-end defect detection” with full defect traceability and the ability to unambiguously correlate device killer defects to optically detected features and their point of origin within the process. Success of the program can be measured by yield improvements at our partner’s facilities and new product orders.

Meeks, Steven↗

Confined Tube Crimp Using Portable Hand Tools

The Lawrence Radiation Laboratory developed handheld tools that crimp a 1/16 inch OD tube, forming a leak tight seal1 (see Figure 1). The leak tight seal forms by confining the 1/16 inch OD tubing inside a die while applying crimp pressure. Under confined pressure, the tube walls weld at the crimp. The purpose of this study was to determine conditions for fabricating a leak tight tube weld. The equipment was used on a trial-and-error basis, changing the conditions after each attempt until successful welds were fabricated. To better confine the tube, the die faces were polished. Polishing removed a few thousandths of an inch from the die face, resulting in a tighter grip on the tubing wall. Using detergent in an ultrasonic bath, the tubing was cleaned. Also, the time under crimp pressure was increased to 30 seconds. With these modifications, acceptable cold welds were fabricated. After setting the conditions for an acceptable cold weld, the tube was TIG welded across the crimped face.

42 ENGINEERING↗